Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINEAR ACCELERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CeBrA demonstrator for particle-γ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

We report on a highly selective experimental setup for particle-γ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr scintillators for γ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr 3 scintillation detectors of the CeBr 3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γ-decay branching ratios and particle-γ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γ-ray detection with the fast CeBrA detectors. As a result, selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental design of a W-band corrugated waveguide for wakefield acceleration studies

Radiofrequency (RF) structures in the sub-terahertz (sub-THz) regime are of interest for applications in structure wakefield acceleration due to their compact size and potential for high gradients. Here, we present the design, fabrication, and experimental setup of a metallic corrugated waveguide at 110 GHz, optimized for the 42 MeV electron beam parameters at the Argonne Wakefield Accelerator (AWA). The emittance exchange (EEX) beamline at AWA was used to perform longitudinal bunch shaping for two cases: (1) a high decelerating gradient experienced by a single drive electron bunch about 250 μm long; (2) a high transformer ratio using a two-bunch train consisting of a triangularly shaped drive bunch followed by a long witness bunch to probe the wakefield. Preliminary experimental results are presented, and data analysis is ongoing.

43 PARTICLE ACCELERATORS↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗

Attosecond-Angstrom free-electron-laser towards the cold beam limit

Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.

43 PARTICLE ACCELERATORS↗

Accurate and confident prediction of electron beam longitudinal properties using spectral virtual diagnostics

Abstract Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool’s accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE’s user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Cross Section Measurements At The RPI LINAC

Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron generator based on intense lithium beam driver

We are proposing a compact neutron generator based on a Li beam driver. The proposed neutron generator comprises a laser ion source, a radio-frequency quadrupole linear accelerator (RFQ linac), a drift tube linac, and a target containing protons. In the generator, the lithium ion is used as a projectile instead of protons to utilize the kinematic focusing technique. The technique enables us to enhance the neutron flux without increasing the beam energy, which is important to develop a clean compact neutron generator. Moreover, the combination of a laser ion source and a RFQ linac with the direct plasma injection scheme will provide several tens of mA of a fully ionized lithium beam, which is much higher than that of conventional heavy ion sources comparable with proton drivers. Neutrons are generated by the nuclear reaction of the lithium ions and protons in the beam target. In this paper, we reported the current status of the development. For RFQ, we designed the RFQ rods to accelerate 40 mA of 7Li3+. We fabricated and installed the rods into a cavity, and, as a first test, accelerated 10 mA of C6+ successfully.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Selecting XFEL single-particle snapshots by geometric machine learning

A promising new route for structural biology is single-particle imaging with an X-ray Free-Electron Laser (XFEL). This method has the advantage that the samples do not require crystallization and can be examined at room temperature. However, high-resolution structures can only be obtained from a sufficiently large number of diffraction patterns of individual molecules, so-called single particles. Here, we present a method that allows for efficient identification of single particles in very large XFEL datasets, operates at low signal levels, and is tolerant to background. This method uses supervised Geometric Machine Learning (GML) to extract low-dimensional feature vectors from a training dataset, fuse test datasets into the feature space of training datasets, and separate the data into binary distributions of “single particles” and “non-single particles.” As a proof of principle, we tested simulated and experimental datasets of the Coliphage PR772 virus. We created a training dataset and classified three types of test datasets: First, a noise-free simulated test dataset, which gave near perfect separation. Second, simulated test datasets that were modified to reflect different levels of photon counts and background noise. These modified datasets were used to quantify the predictive limits of our approach. Third, an experimental dataset collected at the Stanford Linear Accelerator Center. The single-particle identification for this experimental dataset was compared with previously published results and it was found that GML covers a wide photon-count range, outperforming other single-particle identification methods. Moreover, a major advantage of GML is its ability to retrieve single particles in the presence of structural variability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prediction challenge: First principles simulation of the ultrafast electron diffraction spectrum of cyclobutanone

Computer simulation has long been an essential partner of ultrafast experiments, allowing the assignment of microscopic mechanistic detail to low-dimensional spectroscopic data. However, the ability of theory to make a priori predictions of ultrafast experimental results is relatively untested. Herein, as a part of a community challenge, we attempt to predict the signal of an upcoming ultrafast photochemical experiment using state-of-the-art theory in the context of preexisting experimental data. Specifically, we employ ab initio Ehrenfest with collapse to a block mixed quantum–classical simulations to describe the real-time evolution of the electrons and nuclei of cyclobutanone following excitation to the 3s Rydberg state. The gas-phase ultrafast electron diffraction (GUED) signal is simulated for direct comparison to an upcoming experiment at the Stanford Linear Accelerator Laboratory. Following initial ring-opening, dissociation via two distinct channels is observed: the C3 dissociation channel, producing cyclopropane and CO, and the C2 channel, producing CH2CO and C2H4. Direct calculations of the GUED signal indicate how the ring-opened intermediate, the C2 products, and the C3 products can be discriminated in the GUED signal. We also report an a priori analysis of anticipated errors in our predictions: without knowledge of the experimental result, which features of the spectrum do we feel confident we have predicted correctly, and which might we have wrong?

Chemistry↗

Study of ablation and shock generation across three orders of magnitude of laser intensity with 100 ps laser pulses

The laser ablation and subsequent shock generation in solid targets plays an important role in a variety of research topics from equation of state models for materials to inertial confinement fusion. One of the long-standing issues is the knowledge of ablation depth in the picosecond time regime. Here, we report on a direct technique for determining the ablation depth in aluminum using x-ray diffraction data from Linac Coherent Light Source at the Stanford Linear Accelerator Center. This technique gives a direct measurement of the shock wave propagation in the bulk target, enabling an ability to discern early timescale physics from late timescale effects not available in postmortem analysis. We find that the ablation depths only vary by 0.2 μm across three orders of magnitude of laser intensity, while the pressure increased by a factor of 10 following a square root dependence on laser pulse energy. We further observe that the ablation depth in this intensity range (10 11 –10 13 W/cm 2 in intensity, corresponding to 0.8–80 J/cm 2 in fluence) cannot be modeled by a universal scaling law, given the complexity of the mechanisms governing laser ablation in this intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗