Search NASA⌕ Search

DOE OSTI · 1995227

Thermal Cross Section Measurements At The RPI LINAC

Abstract

Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fritz, Dominik, Danon, Yaron, Rapp, Michael, Trumbull, Timothy, Zerkle, Michael, Holmes, Jesse, Chapman, Chris, Arbanas, Goran, Brown, Jesse, Ramic, Kemal, Hu, Xunxiang, Ney, Adam, Brain, Peter, Singh, Sukhjinder, Cook, Katelyn, Wang, Benjamin. 2023-05-26. Thermal Cross Section Measurements At The RPI LINAC. https://doi.org/10.1051/epjconf%2F202328401020

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗