Search NASA⌕ Search

SEARCH · Search NASA

Results for “Molecular contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Instrumentation concepts and requirements for a space vacuum research facility

An earth-orbiting molecular shield that offers a unique opportunity for conducting physics, chemistry, and material processing experiments under a combination of environmental conditions that are not available in terrestrial laboratories is equipped with apparatus for forming a molecular beam from the freestream. Experiments are carried out using a moderate energy, high flux density, high purity atomic oxygen beam in the very low density environment within the molecular shield. As a minimum, the following instruments are required for the molecular shield: (1) a mass spectrometer; (2) a multifunction material analysis instrumentation system; and (3) optical spectrometry equipment. The design is given of a furlable molecular shield that allows deployment and retrieval of the system (including instrumentation and experiments) to be performed without contamination. Interfaces between the molecular shield system and the associated spacecraft are given. An in-flight deployment sequence is discussed that minimizes the spacecraft-induced contamination in the vicinity of the shield. Design approaches toward a precursor molecular shield system are shown.

Norton, H. N.↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Analysis of scintillation light dependence on liquid Argon purity

Previous studies have investigated the correlation between impurity concentrations in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield. These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N_2),can influence LAr scintillation properties without necessarily affecting electron lifetime. Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetimes in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS experiment consists of two cryostats that have shown some discrepancies in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats.

Saia, Clara [Catania Astrophys. Observ.]↗

Chemisorption kinetics of hydrogen on evaporated iron films

An investigation is conducted of the kinetics of isothermal adsorption-desorption processes involving molecular hydrogen which is chemisorbed onto thin (20 to 50 A) polycrystalline Fe films at temperatures near 300 K. The results of the investigation indicate that chemisorption in the H2-Fe system occurs via a precursor state of molecularly adsorbed hydrogen. Contamination of the surface from unknown impurities in the gas phase is found to affect the number of available adsorption sites and to modify the prefactor for the absolute desorption rate constant for the precursor state.

Shanabarger, M. R.↗

Application of biocatalysts to Space Station ECLSS and PMMS water reclamation

Immobilized enzyme reactors have been developed and tested for potential water reclamation applications in the Space Station Freedom Environmental Control and Life Support System (ECLSS) and Process Materials Management System (PMMS). The reactors convert low molecular weight organic contaminants found in ECLSS and PMMS wastewaters to compounds that are more efficiently removed by existing technologies. Demonstration of the technology was successfully achieved with two model reactors. A packed bed reactor containing immobilized urease was found to catalyze the complete decomposition of urea to by-products that were subsequently removed using conventional ion exchange results. A second reactor containing immobilized alcohol oxidase showed promising results relative to its ability to convert methanol and ethanol to the corresponding aldehydes for subsequent removal. Preliminary assessments of the application of biocatalysts to ECLSS and PMMS water reclamation sytems are presented.

Jolly, Clifford D.↗

Environmental monitors in the Midcourse Space Experiments (MSX)

The Midcourse Space Experiment (MSX) is an SDIO sponsored space based sensor experiment with a full complement of optical sensors. Because of the possible deleterious effect of both molecular and particulate contamination on these sensors, a suite of environmental monitoring instruments are also being flown with the spacecraft. These instruments are the Total Pressure Sensor based on the cold-cathode gauge, a quadrupole mass spectrometer, a Bennett-type ion mass spectrometer, a cryogenic quartz crystal microbalance (QCM), four temperature-controlled QCM's, and a Xenon and Krypton Flash Lamp Experiment. These instruments have been fully space-qualified, are compact and low cost, and are possible candidate sensors for near-term planetary and atmospheric monitoring. The philosophy adopted during design and fabrication, calibration and ground testing, and modeling will be discussed .

Uy, O. M.↗

Effects of low earth orbit

The effects of low earth orbit on the Long-Duration Exposure Facility (LDEF) spacecraft are reported. The LDEF spacecraft was deployed in low earth orbit in 1984 and was retrieved in 1990. The structure and design of LDEF is described. The dose of ionizing radiation received, data obtained, and its effects on the satellite are discussed. Atomic oxygen surface effects, oxygen induced damage, and damage from meteoroids and man-made debris are examined and an analysis of meteoroid impacts is presented. The effects of molecular and particulate contamination of the spacecraft's surface and instrument damage were analyzed. Post-flight analysis of LDEF's framework and experiments provided much information about the space environment and its effects on spacecraft materials and will be useful in the design of long-lived large space structures.

Murr, Lawrence E.↗

Application of Direct Simulation Monte Carlo to Satellite Contamination Studies

A novel method is presented to estimate contaminant levels around spacecraft and satellites of arbitrarily complex geometry. The method uses a three-dimensional direct simulation Monte Carlo algorithm to characterize the contaminant cloud surrounding the space platform, and a computer-assisted design preprocessor to define the space-platform geometry. The method is applied to the Upper Atmosphere Research Satellite to estimate the contaminant flux incident on the optics of the halogen occultation experiment (HALOE) telescope. Results are presented in terms of contaminant cloud structure, molecular velocity distribution at HALOE aperture, and code performance.

Rault, Didier F. G.↗

Demonstration of Imaging Flow Diagnostics Using Rayleigh Scattering in Langley 0.3-Meter Transonic Cryogenic Tunnel

The feasibility of using the Rayleigh scattering technique for molecular density imaging of the free-stream flow field in the Langley 0.3-Meter Transonic Cryogenic Tunnel has been experimentally demonstrated. The Rayleigh scattering was viewed with a near-backward geometry with a frequency-doubled output from a diode-pumped CW Nd:YAG laser and an intensified charge-coupled device camera. Measurements performed in the range of free-stream densities from 3 x 10(exp 25) to 24 x 10(exp 25) molecules/cu m indicate that the observed relative Rayleigh signal levels are approximately linear with flow field density. The absolute signal levels agree (within approx. 30 percent) with the expected signal levels computed based on the well-known quantities of flow field density, Rayleigh scattering cross section for N2, solid angle of collection, transmission of the optics, and the independently calibrated camera sensitivity. These results show that the flow field in this facility is primarily molecular (i.e., not contaminated by clusters) and that Rayleigh scattering is a viable technique for quantitative nonintrusive diagnostics in this facility.

Shirinzadeh, B.↗

An Evaluation of the Vapor Phase Catalytic Ammonia Removal Process for Use in a Mars Transit Vehicle

An experimental program has been developed to evaluate the potential of the Vapor Phase Catalytic Ammonia Reduction (VPCAR) technology for use as a Mars Transit Vehicle water purification system. Design modifications which will be required to ensure proper operation of the VPCAR system in reduced gravity are also evaluated. The VPCAR system is an integrated wastewater treatment technology that combines a distillation process with high temperature catalytic oxidation. The distillation portion of the system utilizes a vapor compression distillation process to provide an energy efficient phase change separation. This portion of the system removes any inorganic salts and large molecular weight, organic contaminates, i.e., non-volatile, from the product water stream and concentrates these contaminates into a byproduct stream. To oxidize the volatile organic compounds and ammonia, a vapor phase, high temperature catalytic oxidizer is used. This catalytic system converts these compounds along with the aqueous product into CO2, H2O, and N2O. A secondary catalytic bed can then be used to reduce the N2O to nitrogen and oxygen (although not evaluated in this study). This paper describes the design specification of the VPCAR process, the relative benefits of its utilization in a Mars Transit Vehicle, and the design modification which will be required to ensure its proper operation in reduced gravity. In addition, the results of an experimental evaluation of the processors is presented. This evaluation presents the processors performance based upon product water purity, water recovery rates, and power.

Flynn, Michael↗

X-ray Spectral Variation of (eta) Car through the 2003 X-ray Minimum

The Lunar Orbiting Laser Altimeter (LOLA) will fly on the Lunar Reconnaissance Orbiter (LRO). The laser is based upon the one in the Mercury Laser Altimeter (MLA) . LOLA will fly two lasers instead one in laser cavity. The MLA laser has a six year flight to station. Lasers can fire in air with O2 present. During testing and on orbit, LOLA will fire in vacuum. The laser cavity must be sealed against molecular and particulate contaminants. Mission to Moon wi start with 60 days of launch.

Hamaguchi, Kenji↗

Payload/orbiter contamination control requirement study, volume 1, exhibit A

This study is to identify and quantify the expected molecular and particulate on orbit contaminant environment for selected shuttle payloads as a result of major spacelab and shuttle orbiter contaminant sources. This investigation reviews individual payload susceptibilities to contamination, identifies the combined induced environment, identifies the risk of spacelab/payload critical surface(s) degradation, and provides preliminary contamination recommendations. It also establishes limiting factors which may depend upon operational activities associated with the payloads, spacelab, and the shuttle orbiter interface or upon independent payload functional activities.

Bareiss, L. E.↗

Evaluating size exclusion chromatography for nucleic acid removal in Klebsiella pneumoniae cell surface polysaccharide purification

Cell surface-associated polysaccharides in Klebsiella are major virulence determinants and crucial targets for developing vaccines. Traditionally, the purification of these cell surface polysaccharides from Klebsiella pneumoniae involves a multi-step process comprising phenol extraction, nuclease digestion, ultracentrifugation, and repeated ethanol extractions. In this study, we evaluated size exclusion chromatography for effectively eliminating nucleic acid contamination while purifying high molecular weight cell surface-associated polysaccharides. Post-initial extraction, the nucleic acid content remains significantly elevated, and kinetic analysis reveals that DNase I and RNase A digestion is neither economically viable nor effective for removing these contaminants. Employing an appropriate size exclusion resin removes over 99 % of nucleic acid contamination, as confirmed by nucleic acid content analysis and agarose gel electrophoresis. Purity and structural analysis using 1H 1D-NMR and 2D-NMR demonstrate that the cell surface-associated polysaccharide purified with this study is highly homogeneous and identified as antigenic O-polysaccharide. This approach streamlines the purification process by removing the need for nuclease digestion and additional ethanol precipitation steps.

60 APPLIED LIFE SCIENCES↗

Specific molecular design of polycarboxylate polymers exhibiting optimal compatibility with clay contaminants in concrete

Highlights: • Allyl ether-based PCEs with short side chain length and low side chain density presented superior clay resistance. • PCEs with medium side chain density exhibited best clay robustness when compared at the absolute dosed quantities. • The proportion of PCE being intercalated into the layered structure of clay was quantified. It is widely recognized that the dispersing ability of polycarboxylate superplasticizers (PCEs) could be hindered due to the presence of clay contaminants in concrete. In this study, a series of allyl ether-based polycarboxylate superplasticizers possessing short polyethylene glycol side chains was successfully synthesized and probed for their clay tolerance. The resulting PCE polymers were characterized via Size Exclusion Chromatography (SEC) to obtain their molecular properties. Thereafter, their dispersing ability was probed in the absence and presence of sodium bentonite. Allyl ether-based polycarboxylate (APEG) polymers possessing short side chains were found to exhibit enhanced clay resistance as compared to that of conventional MPEG PCEs holding long pendant chains. The mode of interaction between APEG PCEs and bentonite was investigated via sorption and XRD measurements. The data revealed that APEG PCEs possessing a lower side chain density intercalate less into the interlayer space of bentonite than those exhibiting higher side chain density.

36 MATERIALS SCIENCE↗

Bakeout Workshop

Spacecraft hardware thermal vacuum exposures and bakeouts have been used for years to reduce molecular outgassing to limit contamination to critical optics and sensors on-ground and in orbit. This presentation will discuss lessons learned and vacuum procedural techniques to make the most of your vacuum time. Quartz Crystal Microbalances (QCMs) and Residue Gas Analyzers (RGA) are 2 devices that help track molecular outgassing and examples will be shown on how to use them for your analytical benefit.

Outgassing thermal vacuum QCM RGA↗

Silicon Holder For Molecular-Beam Epitaxy

Simple assembly of silicon wafers holds silicon-based charge-coupled device (CCD) during postprocessing in which silicon deposited by molecular-beam epitaxy. Attains temperatures similar to CCD, so hotspots suppressed. Coefficients of thermal expansion of holder and CCD equal, so thermal stresses caused by differential thermal expansion and contraction do not develop. Holder readily fabricated, by standard silicon processing techniques, to accommodate various CCD geometries. Silicon does not contaminate CCD or molecular-beam-epitaxy vacuum chamber.

Hoenk, Michael E.↗

Preliminary Shuttle payload contamination assessment

The paper discusses the molecular induced atmosphere of the Shuttle Orbiter and a payload carrier (Spacelab) configuration - long module and a 3-m pallet) in the Shuttle Orbiter payload bay and compares it to the ambient atmosphere at various orbital altitudes. The density and flux of the contaminants are expressed as a function of distance out of the payload bay for a line-of-sight perpendicular to the payload bay and payload carrier. Isodensity plots about the Shuttle Orbiter for a side and end view for each major source are presented. The major sources considered are the external surface materials mass loss, pressurized habitation area leakage, attitude control engines, and supplemental flash evaporator venting. The resulting plots provide an insight into the extent and spatial variation of the on-orbit contaminant-induced environment.

Ress, E. B.↗

Impact of organic solutes on capillary phenomena in water-CO2-quartz systems

Hypothesis: The migration of supercritical CO2 (scCO2) injected into underground reservoirs as part of carbon capture and storage is influenced by organic contamination affecting mineral wettability. Molecular dynamics (MD) simulations of relevant systems that incorporate representative organic solutes allow detailed investigation of changes in fundamental interfacial and capillary properties. Experiments: We use MD simulations to explore the effects of four organic solutes (quinoline, decanoic acid, coronene, sorgoleone) on the wettability of quartz by water in the presence of scCO2. We examine the impacts of polar, alkyl, and aromatic moieties as well as fluid flow velocity at elevated temperatures and pressures. Findings: Organic molecules accumulate at the water-CO2 interface, where they distribute according to their size and functional groups. Certain organics penetrate the adsorbed water film at the quartz-CO2 interface, revealing two modes of hydrogen bonding between polar organic functional group, water, and quartz surface –OH groups. Interfacial energies and contact angles are minimally impacted by organic adsorption at the water-CO2 interface, possibly due to simultaneous CO2 desorption. Non- equilibrium MD simulations reveal that flow-induced redistribution of organic compounds modulates the radii of curvature of the advancing and receding water-CO2 interfaces. Our results indicate that organic adsorption on water surfaces is likely ubiquitous during multi-phase flow in soils and sedimen- tary rocks, with implications for the mobilization and transport of organic compounds.

36 MATERIALS SCIENCE↗