Effects of a Straightening Operation on Performance of Inconel 550 Buckets
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Crew Exploration Vehicle, named Orion, is a critical element in the Constellation Program to develop the transportation system needed to send humans back to the moon and then beyond. Lockheed Martin is the prime contractor for the Orion spacecraft, which is managed by the Johnson Space Center. The Orion GN&C sub-system is being jointly developed by NASA and Lockheed Martin through a mode team approach. The GN&C is a critical element of the Orion mission to carry astronauts to low earth orbit to service the International Space Station and then on later flights to transfer and return a crew of four to the moon. The Orion GN&C system must perform monitoring and abort functions during ascent, rendezvous and docking in both low earth and lunar orbits, perform uncrewed lunar loiter operations, perform trans earth injection and atmospheric entry and landing. The Orion also must be integrated with the Ares I Crew Launch Vehicle, the Earth Departure Stage of the Ares V and the Lunar Surface Access Module. This paper provides an overview of the Orion GN&C system. The functional capabilities of the Orion GN&C will be provided in the context of Constellation architecture, the key GN&C requirements will be summarized, the GN&C architecture will be presented, the development schedule and plans will summarized and finally conclusions will be presented.
This slide presentation details the Mars Exploration Rover (MER) imaging system. Over 144,000 images have been gathered from all Mars Missions, with 83.5% of them being gathered by MER. Each Rover has 9 cameras (Navcam, front and rear Hazcam, Pancam, Microscopic Image, Descent Camera, Engineering Camera, Science Camera) and produces 1024 x 1024 (1 Megapixel) images in the same format. All onboard image processing code is implemented in flight software and includes extensive processing capabilities such as autoexposure, flat field correction, image orientation, thumbnail generation, subframing, and image compression. Ground image processing is done at the Jet Propulsion Laboratory's Multimission Image Processing Laboratory using Video Image Communication and Retrieval (VICAR) while stereo processing (left/right pairs) is provided for raw image, radiometric correction; solar energy maps,triangulation (Cartesian 3-spaces) and slope maps.
SIM Lite Astrometric Observatory, a space borne mission to be located in a solar Earth-trailing orbit, will conduct high precision differential astrometry. During the 5-year mission, SIM Lite will search about 60 nearby Sun-like stars for exoplanets of mass down to one Earth mass, in the Habitable Zone of those stars. In addition, SIM Lite will survey the architecture of planetary systems of about 1000 stars of all ages and types. SIM Lite will also build a 4 micro-arc-second astrometric grid and perform global astrometry on a variety of astrophysics objects. The instrument consists of two Michelson stellar interferometers and a precision telescope. The Science interferometer is composed of two 50 cm collectors separated by a 6 meter baseline. The technology development was completed in 2005. The mission is now ready for full flight implementation.
This presentation examines the UTMs second mantra, a risk-based approach where geographical needs and use cases determine the airspace performance requirements and draws lessons from geofence buffer sizing research and trajectory conformance requirement research.
Explore the source record for details and available documents.
An overview presentation of the H-3PO laboratory for a Virginia Tech: Wearable Bioinstrumentation guest lecture.
The carbon vapor deposition (CVD) reactor is a technology developed by Honeywell Aerospace to convert methane, at high temperatures, into hydrogen and solid carbon. This element is coupled with a Sabatier reactor to support a closed-loop environmental control and life support system with the aim of achieving nearly complete oxygen recovery (> 95%). Initial open-loop, brassboard CVD reactor tests and simulations have shown the CVD’s ability to achieve moderately high methane conversion and high hydrogen selectivity. However, in an integrated system, additional deficiencies are expected due to recycling of unreacted or extraneous species from the Sabatier reactor (e.g., carbon dioxide, hydrogen, water) and CVD reactor (e.g., hydrocarbons, methane, etc.). Sabatier and CVD reactor models were integrated and simulated to predict potential impacts to individual reactors’ and the overall system’s performance. The simulations showed that increasing the recycle of the CVD effluent hydrogen combined with decreasing the system inlet hydrogen flow rate (i.e., drawing a stoichiometric flow rate from an electrolyzer) can lead to an oxygen recovery of > 95%. However, system integration comes at a detriment to the individual reactors. The simulations show the initial conversion from the integrated system (Sabatier = 87% and CVD = 59%) to be lower than the standalone systems (Sabatier = 91% and CVD = 69%). Furthermore, transient simulations show substrate densification, leading to worsening methane conversion coupled with increasing acetylene production, which is commensurate with soot formation. Simulations predict a shortening of the maintenance interval (i.e., time until CVD methane conversion drops below 50%) in the integrated system, which would increase the consumable substrate mass. These analyses highlight the importance of long-duration, integrated tests to corroborate these findings as well as suggest potential modifications (e.g., intermediate gas separations) to improve performance.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Long-pulse, high-performance operation with tungsten plasma-facing components is a crucial challenge for achieving steady-state (SS) goals in ITER and future fusion devices. This paper presents a joint international effort between the DIII-D and KSTAR tokamaks aimed at demonstrating the compatibility of the high q 95 ~ 6 hybrid scenario with a tungsten divertor and superconducting coils. A DIII-D hybrid scenario recipe is successfully tailored to KSTAR’s operational constraints, which facilitates cross-device studies. The results show successful 30 s long-pulse operation in KSTAR at a normalized beta (β N = 2.4) with a benign m/n = 4/3 mode and effective mitigation of tungsten accumulation. Despite this success, the KSTAR scenario exhibits a greater than 25% reduction in thermal confinement compared to the DIII-D reference. To investigate this discrepancy, we performed a predictive TGYRO validation study, which suggests that the difference is likely caused by a weaker temperature pedestal in the KSTAR discharge due to a higher and narrower density pedestal. In addition, such lower thermal confinement leads to higher impurity accumulation, possibly due to a change in neoclassical transport with increased inward pinch, which further degrades global confinement. We also report that stationary, long-pulse operation with sustained thermal confinement requires consistent fueling and wall conditioning. These findings highlight the importance of optimized fueling and real-time wall conditioning in achieving a high temperature pedestal and strong global confinement during stable long-pulse operation. We propose potential approaches toward fully SS, long-pulse operation, including real-time wall conditioning using an impurity dropper in KSTAR and future tokamaks.
Design, mission, flight operations, experiment data, and subsystem performances for Lunar Orbiter 4 extended mission
Surrogate measures are proposed as an alternative to direct assessment of operational performance for purposes of screening agents who may have to work under unusual stresses or in exotic environments. Such measures are particularly proposed when the surrogate can be empirically validated against the operational criterion. The focus is on cognitive (or throughput) performances in humans as opposed to sensory (input) or motor (output) measures, but the methods should be applicable for development of batteries which will tap input/output functions. A menu of performance tasks is under development for implementation on a battery-operated portable microcomputer, with 21 tests currently available. The tasks are reliable and become stable in minimum amounts of time; appear sensitive to some agents; comprise constructs related to actual job tasks; and are easily administered in most environments. Implications for human factors engineering studies in environmental stress are discussed.
The performance capability was assessed of operators performing simulated space tasks using manipulator systems which had compliance and force feedback varied. Two manipulators were used, the E-2 electromechanical man-equivalent (force, reach, etc.) master-slave system and a modified CAM 1400 hydraulic master-slave with 100 lbs force capability at reaches of 24 ft. The CAM 1400 was further modified to operate without its normal force feedback. Several experiments and simulations were performed. The first two involved the E-2 absorbing the energy of a moving mass and secondly, guiding a mass thru a maze. Thus, both work and self paced tasks were studied as servo compliance was varied. Three simulations were run with the E-2 mounted on the CAM 1400 to evaluate the concept of a dexterous manipulator as an end effector of a boom-manipulator. Finally, the CAM 1400 performed a maze test and also simulated the capture of a large mass as the servo compliance was varied and with force feedback included and removed.
The worldwide demand for Small Modular Reactors (SMRs) has surged in recent years due to their enhanced safety and versatility in supporting diverse industrial sectors. A unique feature of SMR operation is that a single human operator is responsible for managing multiple modules. Therefore, securing a sufficient amount of human performance data pertaining to this new environment is essential for the safe operation of SMRs. In this explanatory study, a series of experiments were conducted using the NuScale simulator, a representative SMR design, with student operators. A total of 12 student operators were assigned two types of off-normal events and asked to cope with them using paper-based procedures. Subsequently, their task performance times were compared with those of student operators responsible for a single unit based on the Task Complexity (TACOM) measure. Results indicate that the performance of student operators under the experimental conditions of this study degraded by a factor of 2 to 3, depending on the characteristics of the off-normal events.
Simulated altitude testing of a two-dimensional, convergent-divergent, thrust vectoring and reversing exhaust nozzle was accomplished. An important objective of this test was to develop test hardware and techniques to properly operate a vectoring and reversing nozzle within the confines of an altitude test facility. This report presents detailed information on the major test support systems utilized, the operational performance of the systems and the problems encountered, and test equipment improvements recommended for future tests. The most challenging support systems included the multi-axis thrust measurement system, vectored and reverse exhaust gas collection systems, and infrared temperature measurement systems used to evaluate and monitor the nozzle. The feasibility of testing a vectoring and reversing nozzle of this type in an altitude chamber was successfully demonstrated. Supporting systems performed as required. During reverser operation, engine exhaust gases were successfully captured and turned downstream. However, a small amount of exhaust gas spilled out the collector ducts' inlet openings when the reverser was opened more than 60 percent. The spillage did not affect engine or nozzle performance. The three infrared systems which viewed the nozzle through the exhaust collection system worked remarkably well considering the harsh environment.