Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLISHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

Build Optimization Software Tools (BOOST) v2.0.0

Build Optimization Software Tools (BOOST) accelerate the design of DNA, RNA and protein sequences for their synthesis and assembly in an automated and scalable fashion. The BOOST Juggler automates the following two design tasks: - Reverse-Translation of protein sequences into DNA sequences - Codon Juggling of DNA sequences The BOOST Polisher provides the following design tasks: - The Verification of DNA sequences against DNA synthesis constraints - The Modification of DNA sequences in case they violate any DNA synthesis constraint In addition, the BOOST Polisher can be instructed to verify and modify DNA sequences against sequence patterns, such as restriction sites. The BOOST Partitioner supports both Gibson/chewback and Yeast assembly (also known as Transformation-Associated Recombination, or TAR) methods when performing the decomposition of large sequences that exceed the maximum length of DNA synthesis into synthesizable building blocks. The Partitioner can be instructed to find building blocks with appropriate overlap sequences, making their assembly into the complete construct more efficient. BOOST Workflows enable, in a customized fashion, the execution of the Juggler, Polisher, and Partitioner tools on a batch of sequences.

Sharkey, Michael↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

Recipe for coating ceramic blades for ion trapping

The first batches of ion traps patterned and coated were processed per the standard 3-step clean, air fire, and metallization processes. The third or fourth lot using this process resulted in poorly adhering metallization. Up until this point, the standard process was used to metallize and pattern ceramic ion traps without fail. At about the 4th batch of parts something changed. After the 5th batch, the ceramic ion traps received generally came with some unknown contamination that does not come off in a standard 3-step clean (Lenium Vapor Degreaser, Acetone, IPA) and air fire (860C for 1 hour) for which this process removes the vast majority of all contamination for most ceramic metallization. This is highly unusual. Using HF + Boiling H 2 O 2 is extreme for cleaning the ceramic ion traps. The contamination was never identified and is stubborn to effectively clean. Standard as-fired ceramic should be very easy to clean as if s fired at temperatures greater than 1400°C and not much in terms of contamination should exist at these temperatures, so there must be an intermediate step/process which is imparting this contamination. It is likely a polishing compound or previous polishing contaminant, but also not easily visually distinguishable until after metallization. The halo marks observed on parts might be fingerprints (less likely) or potential polishing marks (more likely) as metallization typically doesn't cover/hide any damage or contamination, but rather quite clearly the opposite, it accentuates it. Blotchy appearances in the metallization usually indicated an adhesion issue. As a result of the fragility of the parts (yield loss due to handling) and difficulty in identifying the contamination during cleaning, we have taken a conservative approach of HF + H 2 O 2 cleaning for all batches after the contamination and adhesion issues were identified.

36 MATERIALS SCIENCE↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

Experimental and Computational Studies of Stress Corrosion Cracking of Alloys 308/309 and 82/182 Weldments in Corrosive and Radiation Environment

The goal of the project was to determine factors that influence SCC and IASCC in weldments found in LWR nuclear power plants. We focused on a SA508-304L SS weldment fabricated by EPRI using gas tungsten arc welding and used an aggressive BWR normal water chemistry (NWC) immersion environment. This weldment used 309L butter and 308L groove filler material. The microstructure of the 309L butter was non-uniform, exhibiting a 20–30μm thick martensitic layer closest to the SA508 interface, a 1–4 mm thick single γ austenite phase dilution zone, and a γ–δ duplex region extending to the 308L groove filler. The 308L groove filler had an entirely γ–δ duplex microstructure. Two approximately 1-inch thick 304L and SA508 plates approximately 12 by 6 square inches were joined using standard nuclear grade welding techniques. This included a post weld heat treatment of the 309L butter after application, a 0.32 cm fit-up root opening, and 57 bead lines of 308L groove filler applied in 18 layers. A 60 degree weld bevel angle was used and the 309L butter was 1.5 cm thick. Displacement cascade damage was induced using proton irradiation at the Michigan Ion Beam Laboratory. The incident proton energy was 2 MeV, the sample temperature was 360 ºC, and the calculated dpa value at 10 μm (60% of the Bragg peak depth of ~18 μm) was 5 dpa using the quick Kinchin-Pease model. Proton irradiation to this damage level required approximately 125 hours of beam time. Two types of samples were irradiated, tensile specimens and TEM bars. Samples were selected from all regions of the weldment, including the SA508-309L butter interface, the 309L-308L interface, and 308L-304L interface. The stainless steel alloys (304L, 308L, and 309L) within the heat affected zone are characterized by a duplex skeletal morphology of δ-ferrite and γ-austenite resulting from the recrystallization associated with weld fabrication. Approximately 7 to 8 mm of length along the specimen was irradiated. The gauge volume surfaces were mechanically polished and then electro-polished to remove mechanical damage from the mechanical polishing step prior to irradiation. Immersion tests were performed in a recirculating autoclave under BWR NWC conditions (2000 ppb wt. dissolved oxygen, neutral pH, 288 ºC, 10 MPa, and inlet water conductivity <100 nS/cm) to accelerate corrosion. Constant strain rate tests were performed either to failure or to approximately 5% strain. Strain rates of 10 -7 to 10 -6 mm/mm/s were used and typical immersion testing required four to six weeks to achieve failure or strains near 5%. Analysis primarily used advanced electron microscopy techniques of FIB lift out specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fatigue Testing and Characterization of Pre-hydrided Zircaloy-4 Cladding Tubes

The solubility of hydrogen in Zircaloy-4 (Zry-4) at the cladding operating temperature is near 100 wt. ppm. Above this solubility limit, excess hydrogen precipitates as δ-hydride platelets in the cladding material. Because of the effect of the thermal gradient across the cladding thickness on the migration and precipitation of hydrogen, hydride rims are often observed at the cladding outer surface; under excessive corrosion conditions hydride blisters are possible. It is well known that the fatigue of metal alloys, especially high cycle fatigue, is sensitive to the status of surface including the microstructure, roughness, and residual stress. Thus, the question considered herein, is whether excessive hydrogen pickup modifies the microstructure such that it has a degradation effect on the fatigue performance of cladding during operation. This report describes the evaluation of fatigue performance of a pre-hydrided Zry-4 cladding. A commercial Zry-4 was polished and pre-hydrided to 800 ppm and 1300 ppm H contents. The fatigue testing was conducted under strain control at 5 Hz with fully-reversed bending by using a cyclic integrated reversible bending fatigue tester (CIRFT). Six specimens with 1300 ppm and one specimen with 800 ppm were tested. Significant variation in test results were observed. While two of the 1300 ppm specimens failed with less than 1 ×10 5 cycles (at 0.32% and 0.41%), the four other samples did not fail over the strain amplitude range of 0.25% to 0.38%. Interestingly, the fracture initiation site of the failed samples was on the outside diameter (OD) surface rather than on the inside diameter (ID) surface as is typical for the as-polished cladding. This suggested a degrading effect of the hydriding process. Subsequently, three of the unfailed specimens were then further tested at ~0.43% to observe where failure initiation occurred. Significant variation was also observed in these three specimens. One specimen failed at ~9000 cycles while the two others failed at 43000 and 1.06 ×10 5 cycles. The performance here correlated to the location of failure initiation; failure initiated on the OD in the sample that failed after 9000 cycles while it initiated on the ID in the sample that failed after 43000 and 1.06 ×10 5 cycles. Flat features at the OD initiation sites suggest a brittle hydride feature on the surface of those samples was the cause of the degradation in fatigue performance, though the overall hydrogen levels in all samples was similar. A summary of all the observations is provided below: • The un-failed specimens with 1300 ppm H were cycled to failure with a higher amplitude near 0.43%. In addition, the fatigue-treated specimen tended to have a longer fatigue at the same induced amplitude. • Fractography revealed a mixed failure mode for the pre-hydrided specimen. Particularly, the specimen with fracture initiation site (FIS) located on the outer diameter surface of tube tended to have a shorter fatigue life than that of FIS on the inner diameter surface. • Etched cross section was shown to have hydride platelets aligned with tube longitudinal axis as expected, and the density of hydrides is at the similar level as in literature data. Meanwhile, a LECO procedure was applied for hydrogen concentration measurement, which showed the measured hydrogen contents are close to the nominal value. • With the polished cladding tube as baseline, O’Donnell-Lager (O-L) analysis showed that a decrease of about 50% in reduction-of-area (RA) would be needed for the O-L fitting to the fatigue data of 1300 ppm cladding. The suggestion for the next steps is provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of Mechanical Grinding Effects on Niobium Surface

Mechanical grinding is commonly employed to eliminate surface defects such as scratches and pits from niobium cavity surfaces or sheets before cavity fabrication. Subsequently, chemically buffered polishing or electropolishing is often utilized to completely remove residues of the polishing media and any defects induced by mechanical grinding, ensuring a pristine surface. In this study, we conducted a systematic investigation to assess the influence of mechanical grinding using silicon carbide (SiC) and aluminium oxide (Al2O3) polishing media on niobium surfaces. Additionally, the study examines the effects of post-mechanical grinding chemical treatments on surface quality.

Chouhan, V.↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen transport in alpha titanium

Permeation experiments after nitriding the inlet surface of a hollow cylindrical membrane were conducted. Permeation data on two additional specimens given pre-oxidation or pre-nitriding treatments at both inlet and outlet surfaces are presented in terms of Arrhenius plots. Additionally, an analysis of geometry dependence on permeation rate was made for several specimens including the ones mentioned above. For simplicity in this report, the term as-polished is used to refer to a specimen which is either as-polished or is as-polished, pre-oxidized and annealed.

Johnson, D. L.↗

Preparation of ultra small samples for optical and microprobe analysis

This paper describes a simple but satisfactory new method for the preparation of tiny, varied and specialized specimens for electron or ion-microprobe analysis developed over the past five years. Microtektites, individual chondrules, single grains, blebs from lunar samples and meteoritic minerals have been prepared by this technique. A description of the preparation of these usually difficult samples from the initial mounting through the various polishing steps to their final polish is presented in detail. The procedures used to prevent any contamination of these specimens by the polishing agents and to prevent cross contamination to the other samples used for geochronology studies are presented.

Inman, C. S.↗

Ion beam texturing of heat transfer surfaces

Nucleate boiling heat transfer is examined as a means of energy conservation. Nucleate boiling curves were obtained for ion beam textured copper surfaces, untreated cooper surfaces, copper surfaces which had been polished and surfaces which had been coated with a plasma deposited polymer. Results show that texturing aids heat transfer while polishing has the opposite effect. The polymer coatings did not change nucleate boiling behavior. Aging effects were observed for untreated and for polished surfaces, while no such effects were noticed for textured surfaces. These data suggest that aging may be dependent on surface microgeometry, which is important in nucleate boiling heat transfer.

Agarwal, P. K.↗

Fabrication of X-ray telescopes for sounding rocket flights

Two X-ray telescopes and two detector systems were fabricated, and one of the telescopes (15 in. diameter, Wolter type I telescope) was flown on two sounding rocket flights. The telescopes were fabricated using the diamond point technique which provided the accurate figure of the mirrors to about a focal plane blur of 0.5 arc minutes. The 15 in. telescope mirrors were polished using standard polishing techniques to remove tooling marks from the diamond turning, then chemically polished to bring the X-ray reflectivity up to nearly the theoretical values. The optical image formed by the 15 in. telescope was found to produce a blur of about 40 arc seconds for a parallel beam of incoming laser light. The first flight of the telescope produced an X-ray image of Capella which indicated that the X-ray image was blurred to the extent of about 2 arc minutes. This additional image degradation was due to a slight error in focusing the X-ray image onto the detector.

Source record↗

The AXAF technology program: The optical flats tests

The results of a technology program aimed at determining the limits of surface polishing for reflecting X-ray telescopes is presented. This program is part of the major task of developing the Advanced X-ray Astrophysical Facility (AXAF). By studying the optical properties of state-of-the-art polished flat surfaces, conclusions were drawn as to the potential capability of AXAF. Surface microtopography of the flats as well as their figure are studied by X-ray, visual, and mechanical techniques. These techniques and their results are described. The employed polishing techniques are more than adequate for the specifications of the AXAF mirrors.

Williams, A. C.↗

Formation of planar n(+) pockets in GaAs for mixer diode fabrication

A novel technique has been developed to produce n(+) 'pockets' in semiinsulating GaAs bulk material. This technique has produced thick pockets of highly conducting epitaxial material on the substrate surface. The pockets were formed by the growth of a liquid-phase epitaxial (LPE) layer into holes which had been etched into the substrate. Surface uniformity was obtained by chemo-mechanically polishing the substrate surface under tightly controlled conditions. Polishing rates as low as 0.2 micron/min have been obtained. Photographs taken of the pocket cross-sectional area have revealed that growth occurred throughout the entire pocket region. Growth was even found to have occurred along the irregularly shape walls of the packets. The continuous growth throughout the pockets coupled with the subsequent polishing of the substrate have produced exceptionally smooth and planar surfaces. Thicknesses as great as 10 microns have been obtained for the n(+) pockets using this technique. Mixer diodes have been fabricated onto these layers and tested. Preliminary dc measurements taken on these devices have yielded a zero-biased cutoff frequency (Fco) of 800 GHz with a series resistance (Rs) of 6 omega and a zero-biased capacitance (Co) of 30 fF.

Griffin, J. A.↗

Analysis of particulates of comet nucleus samples: Possible use of olivine as indicator phase

The electron microprobe is a proven instrument for particulate analysis and modifications are possible for in situ analysis of particulates in ice at temperatures near that of liquid nitrogen. Present sample requirements allow for polished samples with 0.25 x 0.25 dimensions to be maintained in the sample chamber of a modern electron probe (CAMECA SX-50) at a temperature of -150 C; larger samples are possible but at higher temperatures as determined by thermal conductivity. The major problem is transport and insertion of samples into the instrument through vacuum interlocks. The manufacturer of the above microprobe has designed an exchange mechanism to allow storage and transport of samples previously prepared for their sample holder which attaches to their instrument allowing extraction and insertion of samples while maintaining -150 C temperature. An important test will be the capability of preparing polished surfaces of an ice-particulate sample without loss of particles and at low temperatures. While thin sections of water ice are routine, these are not examined for particulate material and are prepared at temperatures easily obtained in room-size volumes. Anticipated problems include rounding of small grains in the relatively soft ice matrix and the technical problem of dry polishing.

Steele, I. M.↗