Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTON ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy particle production from proton synchrotron radiation in strong magnetic fields in relativistic quantum field theory

We investigate photon, pion, and 𝜌-meson production from proton synchrotron radiation in the presence of strong magnetic fields. The proton decay widths and the luminosities of the emitted particles are calculated within a relativistic quantum framework that incorporates Landau quantization. A scaling rule is derived for the transition probability between different Landau levels. This allows an evaluation of transitions for extremely high Landau numbers exceeding 10 15 . Furthermore, we calculate the momentum distribution of the emitted particles by properly including the proton recoil effect associated with particle emission. The results differ significantly from conventional semiclassical approaches.

Cosmic ray sources↗

Developing the S 32 ( p , d ) S * 31 ( p ) ( γ ) reaction to probe the P 30 ( p , γ ) S 31 reaction rate in classical novae

Background: The 30 P(p,γ) 31 S reaction rate is one of the largest remaining sources of uncertainty in the final abundances of nuclei created in a classical nova involving a ONe white dwarf. The reaction rate directly influences silicon isotopic ratios, which are used as identifiers of presolar grains with nova origins. Additionally, the uncertainty in the 30 P(p,γ) 31 S reaction rate has been found to limit the use of nova nuclear thermometers based on observations of elemental ratios in nova ejecta. Purpose: Reduce uncertainties in the nuclear data for proton-unbound states in 31 S, which act as resonances for the 30 P(p,γ) 31 S reaction at classical nova temperatures, and develop a technique for high efficiency, high-resolution reaction-decay coincidence measurements. Methods: Here, the 32 S(p,d) 31 S reaction was used to populate the states of interest in 31 S. The experiment was performed at the Texas A&M Cyclotron Institute using the LLNL Hyperion array for the detection of charged particles and γ rays. A downstream silicon telescope was used to select reaction deuterons, and a single upstream silicon detector was used to measure protons emitted in the decay of unbound 31 S levels. Results: Several states in 31 S above the proton separation energy were observed to have been populated. Decay protons from the resonant states in 31 S were identified as events in the upstream silicon detectors that came in coincidence with deuterons in the downstream telescope. Protons emitted from these states were measured and branching ratios extracted. Conclusions: While no new reaction rate is derived, spin-parity assignments for several higher-lying proton unbound states have been confirmed. Measured p 0 branching ratios for these levels have been compared to previous measurements with good agreement, and in some cases provided a reduction in uncertainty. The previously identified T = 3/2 state may have been incorrectly assigned a large p 0 branching ratio in a previous measurement. The technique of measuring reaction-decay coincidences with a particle-gamma setup appears promising.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Form Factors and Two-Photon Exchange in High-Energy Elastic Electron-Proton Scattering

We report new precision measurements of the elastic electron-proton scattering cross section for momentum transfer squared (Q$^2$) up to 15.75 (GeV/c)$^2$. These data allow for improved extraction of the proton magnetic form factor at high Q$^2$ and nearly double the Q$^2$ range of direct longitudinal/transverse separated cross sections. A comparison of our results to polarization measurements establishes the presence of hard two-photon exchange in the $e$-$p$ elastic scattering cross section at > 95 % confidence level for Q$^2$ up to 8 (GeV/c)$^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond the proton drip line: Bayesian analysis of proton-emitting nuclei

The limits of the nuclear landscape are determined by nuclear binding energies. Beyond the proton drip lines, where the separation energy becomes negative, there is not enough binding energy to prevent protons from escaping the nucleus. Predicting properties of unstable nuclear states in the vast territory of proton emitters poses an appreciable challenge for nuclear theory as it often involves far extrapolations. In addition, significant discrepancies between nuclear models in the proton-rich territory call for quantified predictions. With the help of Bayesian methodology, we mix a family of nuclear mass models corrected with statistical emulators trained on the experimental mass measurements, in the proton-rich region of the nuclear chart. Separation energies were computed within nuclear density functional theory using several Skyrme and Gogny energy density functionals. We also considered mass predictions based on two models used in astrophysical studies. Quantified predictions were obtained for each model using Bayesian Gaussian processes trained on separation-energy residuals and combined via Bayesian model averaging. Here, we obtained a good agreement between averaged predictions of statistically corrected models and experiment. In particular, we quantified model results for one- and two-proton separation energies and derived probabilities of proton emission. This information enabled us to produce a quantified landscape of proton-rich nuclei. The most promising candidates for two-proton decay studies have been identified. Finally, the methodology used in this work has broad applications to model-based extrapolations of various nuclear observables. It also provides a reliable uncertainty quantification of theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Synchronization effects on rest frame energy and momentum densities in the proton

We obtain two-dimensional relativistic densities and currents of energy and momentum in a proton at rest. These densities are obtained at surfaces of fixed light front time, which physically corresponds to using an alternative synchronization convention. Mathematically, this is done using tilted light front coordinates, which consist of light front time and ordinary spatial coordinates. In this coordinate system, all 16 components of the energy-momentum tensor (EMT) obtain clear physical interpretations, and the nine Galilean components reproduce results from standard light front coordinates. We find angular modulations in several densities that are absent in the corresponding instant form results, which are explained as optical effects arising from using fixed light front time when motion is present within the target. Additionally, transversely polarized spin-half targets exhibit an energy dipole moment—which evaluates to −1/4 for all targets if the Belinfante EMT is used, but which is target dependent and vanishes for pointlike fermions if the asymmetric EMT is instead used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and design of compact, permanent-magnet transport systems for highly divergent, broad energy spread laser-driven proton beams

Laser-driven (LD) ion acceleration has been explored in a newly constructed short focal length laser beamline at the BELLA petawatt facility (interaction point 2, iP2). For applications utilizing such LD ion beams, a beam transport system is required, which for reasons of compactness be ideally contained within 3 m. While they are generated from a micron-scale source, large divergence and energy spread of LD ion beams present a unique challenge to transporting them compared to beams from conventional accelerators. This study gives an overview of proposed compact transport designs using permanent magnets satisfying different requirements depending on the application for the iP2 laser beamline such as radiation biology, material science, and high-energy density science. These designs are optimized for different parameters such as energy spread and peak proton density according to the application’s need. The various designs consist solely of permanent magnet elements, which can provide high magnetic field gradients on a small footprint. While the field strengths are fixed, we have shown that the beam size is able to be tuned effectively by varying the placement of the magnets. The performance of each design was evaluated based on high-order particle tracking simulations of typical LD proton beams. We also examine the ability of certain configurations to tune and select beam energies, critical for specific applications. A more detailed investigation was carried out for a design to deliver 10 MeV LD accelerated ions for radiation biology applications. With these transport system designs, the iP2 laser beamline is ready to house various application experiments.

43 PARTICLE ACCELERATORS↗

Database of Nonaqueous Proton-Conducting Materials

This work presents the assembly of 48 papers, representing 74 different compounds and blends, into a machine-readable database of nonaqueous proton-conducting materials. SMILES was used to encode the chemical structures of the molecules, and we tabulated the reported proton conductivity, proton diffusion coefficient, and material composition for a total of 3152 data points. The data spans a broad range of temperatures ranging from -70 to 260 °C. To explore this landscape of nonaqueous proton conductors, DFT was used to calculate the proton affinity of 18 unique proton carriers. The results were then compared to the activation energy derived from fitting experimental data to the Arrhenius equation. It was found that while the widely recognized positive correlation between the activation energy and proton affinity may hold among closely related molecules, this correlation does not necessarily apply across a broader range of molecules. This work serves as an example of the potential analyses that can be conducted using literature data combined with emerging research tools in computation and data science to address specific materials design problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton-Coupled Defects Impact O–H Bond Dissociation Free Energies on Metal Oxide Surfaces

Proton-coupled electron transfer (PCET) reactions on metal oxides require coupling between proton transfer at the solid-liquid interface and electron transfer involving defects at or near the band edge. Herein, hybrid functional periodic density functional theory is used to elucidate the impact of proton-coupled defects on the bond dissociation free energies (BDFEs) of O-H bonds on anatase TiO 2 surfaces. These O-H BDFEs are directly related to interfacial PCET thermochemistry. Comparison between geometrically similar O-H bonds associated with different defect types, namely conduction d-band electrons or valence p-band holes, reveals that the BDFEs differ by ~81 kcal/mol (3.50 eV), comparable to the wide TiO 2 band gap. These differences are shown to be determined primarily by differences in electron transfer driving forces, which are analyzed by using band energies and inner-sphere reorganization energies within a Marcus theory framework. Furthermore, these fundamental insights about the impact of proton-coupled defects on PCET thermochemistry at semiconductor surfaces have broad implications for electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shielding Analyses for SNS Accelerator Power Upgrade

The Proton Power Upgrade (PPU) project [1] at Spallation Neutron Source (SNS) is aiming at increasing the neutron beam intensities at the First Target Station (FTS) and advancing accelerator capability to additionally power a future Second Target Station (STS) [2]. PPU will involve upgrading the SNS accelerator complex to double the currently available proton beam power from 1.4 to 2.8 MW, by increasing the proton beam energy from 1 GeV to 1.3 GeV and by increasing the proton beam current.PPU will enable new science capabilities enhancing the experiment throughput of the 19 existing FTS instruments, which are heavily oversubscribed. STS will include 22 additional neutron scattering instruments. Numerous neutronics analyses are performed to support PPU evaluating the FTS systems for higher beam power and for system upgrades. Part of the PPU scope is an extension of the Ring to Target Beam Transport (RTBT) line, a stub out of the accelerator tunnel for the future Ring to STS Transport (RTST) line[3]. As the RTST tunnel will not be built within the PPU project, the stub will be shielded by a plug, which is planned to be made from regular concrete.In order to provide radiation protection safety, analyses are required to design adequate plug thickness for the stub. The thickness of the stub is driven by the criterion that the area downstream of the plug is “unrestricted access area”, demanding the dose rate downstream the stub be below 0.25 mrem/h at 30 cm from the surface at normal operation and below 20 Rem/hr for accident cases. Additionally, analyses verifying the amount of soil for shielding the accelerator tunnel to the above stated requirements are performed.

Popova, Irina I.↗

Jet energy scale and resolution measured in proton–proton collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

Jet energy scale and resolution measurements with their associated uncertainties are reported for jets using 36–81 fb -1 of proton–proton collision data with a centre-of-mass energy of √s=13 TeV collected by the ATLAS detector at the LHC. Jets are reconstructed using two different input types: topo-clusters formed from energy deposits in calorimeter cells, as well as an algorithmic combination of charged-particle tracks with those topo-clusters, referred to as the ATLAS particle-flow reconstruction method. The anti-k t jet algorithm with radius parameter R=0.4 is the primary jet definition used for both jet types. This result presents new jet energy scale and resolution measurements in the high pile-up conditions of late LHC Run 2 as well as a full calibration of particle-flow jets in ATLAS. Jets are initially calibrated using a sequence of simulation-based corrections. Next, several in situ techniques are employed to correct for differences between data and simulation and to measure the resolution of jets. The systematic uncertainties in the jet energy scale for central jets (|η|<1.2) vary from 1% for a wide range of high-p T jets (250 T <2000 GeV), to 5% at very low p T (20 GeV) and 3.5% at very high p T (>2.5 TeV). The relative jet energy resolution is measured and ranges from (24±1.5)% at 20 GeV to (6±0.5)% at 300 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗