Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

Mass spectrometry (MS) enables detection of different chemical species with a very high specificity; however, it can be limited by its throughput. Integrating MS with microfluidics has a tremendous potential to improve throughput and accelerate biochemical research. In this work, we introduce Drop-NIMS, a combination of a passive droplet loading microfluidic device and a matrix-free MS laser desorption ionization technique called nanostructure-initiator mass spectrometry (NIMS). This platform combines different droplets at random to generate a combinatorial library of enzymatic reactions that are deposited directly on the NIMS surface without requiring additional sample handling. The enzyme reaction products are then detected with MS. Drop-NIMS was used to rapidly screen enzymatic reactions containing low (on the order of nL) volumes of glycoside reactants and glycoside hydrolase enzymes per reaction. MS “barcodes” (small compounds with unique masses) were added to the droplets to identify different combinations of substrates and enzymes created by the device. We assigned xylanase activities to several putative glycoside hydrolases, making them relevant to food and biofuel industrial applications. Overall, Drop-NIMS is simple to fabricate, assemble, and operate and it has potential to be used with many other small molecule metabolites.

47 OTHER INSTRUMENTATION↗

Characterization of 4H-SiC Low Gain Avalanche Detectors (LGADs)

4H-SiC Low Gain Avalanche Detectors (LGADs) have been fabricated and characterized. The devices employ a circular mesa design with low-resistivity contacts and an SiO 2 passivation layer. The I–V and C–V characteristics of the 4H-SiC LGADs are compared with complementary 4H-SiC PiN diodes to confirm a high breakdown voltage and low leakage current. Both LGADs and PiN diodes were irradiated with alpha particles from a $^{210}_{84}$Po source. The charge collected by each device was compared, and it was observed that low-gain charge carrier multiplication is achieved in the 4H-SiC LGAD.

43 PARTICLE ACCELERATORS↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neuromorphic Information Processing by Optical Media

Classification of features in a scene typically requires conversion of the incoming photonic field int the electronic domain. Recently, an alternative approach has emerged whereby passive structured materials can perform classification tasks by directly using free-space propagation and diffraction of light. In this manuscript, we present a theoretical and computational study of such systems and establish the basic features that govern their performance. We show that system architecture, material structure, and input light field are intertwined and need to be co-designed to maximize classification accuracy. Our simulations show that a single layer metasurface can achieve classification accuracy better than conventional linear classifiers, with an order of magnitude fewer diffractive features than previously reported. For a wavelength λ, single layer metasurfaces of size 100λ x 100λ with aperture density λ -2 achieve ~96% testing accuracy on the MNIST dataset, for an optimized distance ~100λ to the output plane. This is enabled by an intrinsic nonlinearity in photodetection, despite the use of linear optical metamaterials. Furthermore, we find that once the system is optimized, the number of diffractive features is the main determinant of classification performance. The slow asymptotic scaling with the number of apertures suggests a reason why such systems may benefit from multiple layer designs. Finally, we show a trade-off between the number of apertures and fabrication noise.

47 OTHER INSTRUMENTATION↗

MiniCarb: a passive, occultation-viewing, 6U CubeSat for observations of CO 2 , CH 4 , and H 2 O

In this report we present the final design, environmental testing, and launch history of MiniCarb, a 6U CubeSat developed through a partnership between NASA Goddard Space Flight Center and Lawrence Livermore National Laboratory. MiniCarb’s science payload, developed at Goddard, was an occultation-viewing, passive laser heterodyne radiometer for observing methane, carbon dioxide, and water vapor in Earth’s atmosphere at ~1.6 µm s -1 . MiniCarb’s satellite, developed at Livermore, implemented their CubeSat Next Generation Bus plug-and-play architecture to produce a modular platform that could be tailored to a range of science payloads. Following the launch on 5 December 2019, MiniCarb traveled to the International Space Station and was set into orbit on 1 February 2020 via Northrop Grumman’s Cygnus capsule which deployed MiniCarb with tipoff rotation of about 20° s (significantly higher than the typical rate of 3° s -1 from prior CubeSats), from which the attitude control system was unable to recover resulting in a loss of power. In spite of this early failure, MiniCarb had many successes including rigorous environmental testing, successful deployment of its solar panels, and a successful test of the radio and communication through the Iridium network. This prior work and enticing cost (approximately $\$2$ M for the satellite and $\$$250 K for the payload) makes MiniCarb an ideal candidate for a low-cost and rapid rebuild as a single orbiter or constellation to globally observe key greenhouse gases.

47 OTHER INSTRUMENTATION↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the VUV-reflective coating for next-generation liquid xenon detectors

Abstract Coating detector materials with films highly reflective in the vacuum ultraviolet region improves sensitivity of the next-generation rare-event detectors that use liquid xenon. In this work, we investigate the MgF 2 -Al-MgF 2 coating designed to achieve high reflectance at 175 nm, the mean wavelength of liquid xenon (LXe) scintillation. The coating was applied to an unpolished, passivated copper substrate mimicking a realistic detector component of the proposed nEXO experiment, as well as to two unpassivated substrates with “high” and “average” levels of polishing. After confirming the composition and morphology of the thin-film coating using TEM and EDS, the samples underwent reflectance measurements in LXe and gaseous nitrogen (GN2). Measurements in LXe exposed the coated samples to -100°C for several hours. No peeling of the coatings was observed after several thermal cycles. Polishing is found to strongly correlate with the measured specular reflectance (R spec ). In particular, 5.8(5)% specular spike reflectance in LXe was measured for the realistic sample at 20° of incidence, while the values for similar angles of incidence on the high and average polish samples are 62.3(1.3)% and 27.4(7)%, respectively. At large angles (66°–75°), theR spec in LXe for the three samples increases to 23(5)%, 80(8)%, and 84(18)%, respectively. The R spec at around 45° was measured in both GN2 and LXe for average polish sample and shows a reasonable agreement. Importantly, the total reflectance of the samples is comparable and estimated to be 92(8)%, 85(8)%, and 83(8)% in GN2 for the realistic, average, and high polish samples, respectively. This is considered satisfactory for the next-generation LXe experiments that could benefit from using reflective films, such as nEXO and DARWIN, thus validating the design of the coating.

Instruments & Instrumentation↗

The Modeled Performance of the ORNL Matched Filter Detector for Seismic Signatures of Multi-Axle Tractor Trailers

The MINOS program seeks methods to passively monitor the transfer of special materials, which are reproducible and quantitatively defensible. To date, we have demonstrated that short-period seismometers deployed near vehicle tracks can detect and monitor signatures of multi-axle tractor trailers impacting small road obstacles as means to detect and identify some transfer activities. In this report, we model the seismic velocity signal output from a tractor-trailer impacting a small obstacle (a template waveform) to parameterize a matched filter that identifies signals with similar shapes buried in noise, and that indicate repeating events (target waveforms). We then use this model to perform thousands of synthetic experiments, in which we apply our detector to identify noisy waveforms output from a similarly modeled vehicle data set; we process all data in the same manner as we process real data collected from the Oak Ridge National Laboratory (ORNL) seismic network. Our experiments, while limited, reveal that the matched filter shows a high discrimination capability, and at very low SNR values (at visibility thresholds). This means that template waveforms can match target waveforms that are sourced by models that share the same vehicle speed (target vehicles), and have a low probability of mis-identification. In particular, a matched filter designed to detect a five-axle tractor-trailer will reliably identify that target vehicle down to an SNR of 11.25 dB, and within ±0.1 km/hr, while successfully screening target vehicles with three axles.

42 ENGINEERING↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Monte Carlo simulation of the Borexino detector

Borexino is a 300 ton sub-MeV liquid scintillator solar neutrino detector which has been running at the Laboratori Nazionali del Gran Sasso (Italy) since 2007. Thanks to its unprecedented radio-purity, it was able to measure the flux of 7 Be, 8 B, pp, and pep solar neutrinos and to detect geo-neutrinos. A reliable simulation of the detector is an invaluable tool for all Borexino physics analyses. The simulation accounts for the energy loss of particles in all the detector components, the generation of the scintillation photons, their propagation within the liquid scintillator volume, and a detailed simulation of the electronics chain. A novel efficient method for simulating the external background which survives the Borexino passive shield was developed. This technique allows to reliably predict the effect of the contamination in the peripheral construction materials. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino and dark matter communities, especially for current and future large-volume liquid scintillator experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

Oxidation Temperature-Dependent Electrochemical Doping of WO 3 Deposited via Atomic Layer Deposition

Silicon-based photoelectrochemical devices show promise for the performance of light-driven CO 2 reduction but suffer from instability under photoelectrochemical conditions relevant to CO 2 reduction. Coating silicon electrodes with thin layers of metal oxides has shown promise to passivate unstable silicon surfaces, and many different metal oxides can be deposited on silicon using various techniques. In this study, we investigate the fundamental photoelectrochemical performance of WO 3 -coated silicon photoelectrodes, which were generated by oxidation of W-metal films deposited via atomic layer deposition on both degenerately doped (nSi + ) and low-doped (pSi) silicon. Two different oxidation temperatures were investigated (400 and 600 °C), and it was found that the monoclinic phase of WO 3 predominates at both temperatures but that more grain boundaries are present in the 600 °C film. From X-ray photoelectron spectroscopy, the stoichiometry of both films was found to be 1:3 W:O, and low electron energy loss experiments indicate band gaps of 3.0 and 3.1 eV for 400 and 600 °C films, respectively. Cyclic voltammetry experiments showed that the electron transfer kinetics increased after continued redox cycling, particularly for the material produced at 400 °C. X-ray photoelectron spectra suggest that the observed increase in electrode conductivity is due to the formation of oxygen vacancies in the film. Electrochemical impedance spectroscopy indicated that charge transport through the films was impacted by the grain boundaries that formed during oxidation of the film. Photoelectrochemical studies on pSi/WO 3 electrodes were highly variable, only producing a photocurrent and photovoltage with some samples. Our best sample, formed at 400 °C, produced a photovoltage of 180 mV, which is lower than what has previously been reported for WO 3 -coated silicon (500 mV). We hypothesize that the variability in photoelectrochemical experiments arose from a roughened WSiO x interface that is generated during film preparation. WO 3 shows promise as a metal oxide coating for silicon, but our results suggest that formation of a high-quality interface between Si and WO 3 is vital for best performance.

Charge transfer↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 2 data

This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb -1 of LHC proton-proton collision data recorded at $\sqrt{s}$ = 13 TeV between 2015 and 2018. Methods for the measurement of electron and photon energies are outlined, along with the current knowledge of the passive material in front of the ATLAS electromagnetic calorimeter. The energy calibration steps are discussed in detail, with emphasis on the improvements introduced in this paper. The absolute energy scale is set using a large sample of Z-boson decays into electron-positron pairs, and its residual dependence on the electron energy is used for the first time to further constrain systematic uncertainties. The achieved calibration uncertainties are typically 0.05% for electrons from resonant Z-boson decays, 0.4% at E T ~ 10 GeV, and 0.3% at E T ~ 1 TeV; for photons at E T ~ 60 GeV, they are 0.2% on average. This is more than twice as precise as the previous calibration. The new energy calibration is validated using J/ψ → ee and radiative Z-boson decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗