Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESISTANCE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Tool For Robotic Resistive Roll Welding

Roll-welding attachment for robot simple, inexpensive device incorporating modified commercial resistance-welding gun. Modified welding gun easily attaches to end effector of robot. Robot applies welding force and moves electrode wheel along prescribed path. Resistance-welding current starts and stops automatically according to force exerted against workpiece. Used to apply brazing foil to workpiece.

Gilber, Jeffrey L.↗

OpenSim Model Improvements to Support High Joint Angle Resistive Exercising

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts

Bioengineering↗

Development of exercise devices to minimize musculoskeletal and cardiovascular deconditioning in microgravity

The paper describes three exercise devices, developed at the NASA-Ames Research Center, for maintaining musculoskeletal and cardiovascular fitness in astronauts during extended space flights. These devices represent the following exercise concepts: (1) exercise against LBNP, (2) instrumented dynamic interlimb resistance, and (3) multiple resistive exercise. The three devices complement each other to provide the aerobic and strength training exercises for different situations. All three devices permit eccentric, concentric, and isometric contractions for a variety of exercises.

Schwandt, Douglas F.↗

Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include the applied device load and the dual cable long bar or single cable T-bar interface between the test subject and the device. Data is also obtained using free weights with the identical loading for a comparison to the resistively loaded exercise device trials. The data drives the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. RESULTS Lower body kinematics, joint moments, joint forces and muscle forces are obtained from the OpenSim biomechanical analysis of the squat exercises under different loading conditions. Preliminary results from the model for the loading conditions will be presented as will hypotheses developed for follow on work.

Human Factors Engineering↗

Electrical Switching of Perovskite Thin-Film Resistors

Electronic devices that exploit electrical switching of physical properties of thin films of perovskite materials (especially colossal magnetoresistive materials) have been invented. Unlike some related prior devices, these devices function at room temperature and do not depend on externally applied magnetic fields. Devices of this type can be designed to function as sensors (exhibiting varying electrical resistance in response to varying temperature, magnetic field, electric field, and/or mechanical pressure) and as elements of electronic memories. The underlying principle is that the application of one or more short electrical pulse(s) can induce a reversible, irreversible, or partly reversible change in the electrical, thermal, mechanical, and magnetic properties of a thin perovskite film. The energy in the pulse must be large enough to induce the desired change but not so large as to destroy the film. Depending on the requirements of a specific application, the pulse(s) can have any of a large variety of waveforms (e.g., square, triangular, or sine) and be of positive, negative, or alternating polarity. In some applications, it could be necessary to use multiple pulses to induce successive incremental physical changes. In one class of applications, electrical pulses of suitable shapes, sizes, and polarities are applied to vary the detection sensitivities of sensors. Another class of applications arises in electronic circuits in which certain resistance values are required to be variable: Incorporating the affected resistors into devices of the present type makes it possible to control their resistances electrically over wide ranges, and the lifetimes of electrically variable resistors exceed those of conventional mechanically variable resistors. Another and potentially the most important class of applications is that of resistance-based nonvolatile-memory devices, such as a resistance random access memory (RRAM) described in the immediately following article, Electrically Variable Resistive Memory Devices (MFS-32511-1).

Liu, Shangqing↗

Magnetic-Field-Tunable Superconducting Rectifier

Superconducting electronic components have been developed that provide current rectification that is tunable by design and with an externally applied magnetic field to the circuit component. The superconducting material used in the device is relatively free of pinning sites with its critical current determined by a geometric energy barrier to vortex entry. The ability of the vortices to move freely inside the device means this innovation does not suffer from magnetic hysteresis effects changing the state of the superconductor. The invention requires a superconductor geometry with opposite edges along the direction of current flow. In order for the critical current asymmetry effect to occur, the device must have different vortex nucleation conditions at opposite edges. Alternative embodiments producing the necessary conditions include edges being held at different temperatures, at different local magnetic fields, with different current-injection geometries, and structural differences between opposite edges causing changes in the size of the geometric energy barrier. An edge fabricated with indentations of the order of the coherence length will significantly lower the geometric energy barrier to vortex entry, meaning vortex passage across the device at lower currents causing resistive dissipation. The existing prototype is a two-terminal device consisting of a thin-film su - perconducting strip operating at a temperature below its superconducting transition temperature (Tc). Opposite ends of the strip are connected to electrical leads made of a higher Tc superconductor. The thin-film lithographic process provides an easy means to alter edge-structures, current-injection geo - metries, and magnetic-field conditions at the edges. The edge-field conditions can be altered by using local field(s) generated from dedicated higher Tc leads or even using the device s own higher Tc superconducting leads.

Sadleir, John E.↗

Near-contact diffusion and compensation in extrinsic photoconductors

Carrier diffusion from heavily doped contact regions has been experimentally monitored with resistivity measurements of variable thickness Si:P extrinsic photoconductors (n(+) -n-n(+)). Modeling of free carrier diffusion at the interface of heavily doped contacts and highly resistive bulk at low temperatures predicts extended regions (5-30 microns) of excess carriers in high purity materials so that, in thin device structures, free carrier diffusion profiles from each contact will overlap and determine the resistivity of the device. In this work, a decrease in resistivity of four orders of magnitude was observed in a 5-micron thick structure compared to a 10-micron thick device. The resistivity of an ohmic structure in the thin limit is strongly dependent on the bulk and near-contact compensation, and resistivity measurements can be used as a sensitive measure of compensation at interfaces or in the tail of implanted layers.

Olsen, C. S.↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive training on one platform without including a treadmill, such as the European Enhanced Exploration Exercise Device (E4D). It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40) who will partake in nominal exercise on the ISS, including running on the treadmill with vibration isolation system 2 (T2), ergometry on the cycle ergometer with vibration isolation and stabilization device (CEVIS), and strength training on the advanced resistive exercise device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. Results: Data collection for this study is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Peeled film GaAs solar cells for space power

Gallium arsenide (GaAs) peeled film solar cells were fabricated, by Organo-Metallic Vapor Phase Epitaxy (OMVPE), incorporating an aluminum arsenide (AlAs) parting layer between the device structure and the GaAs substrate. This layer was selectively removed by etching in dilute hydrofloric (HF) acid to release the epitaxial film. Test devices exhibit high series resistance due to insufficient back contact area. A new design is presented which uses a coverglass superstrate for structural support and incorporates a coplanar back contact design. Devices based on this design should have a specific power approaching 700 W/Kg.

Wilt, D. M.↗

Tamper-Resistant Secure Disposal Container

Closure device for secure waste containers prevents classified papers and other proprietary articles from being withdrawn when container turned on side. Has pendulum that swings comb into closed position when container turned on side. Suspended with axis of rotation perpendicular to axes of combs. Extends through D-shaped cam ring, attached to upper comb with standoff struts. When container tilted sideways, pendulum swings along arc side of D-shaped ring. Forces cam ring aside, moving upper comb toward closed position. If container tilted forward or backward, pendulum does not interfere with comb movement. Spring catches added to combs so if actuated and close container opening, they lock in place to prevent further tampering.

Collins, Earl R., Jr.↗

Microwave and millimeter-wave resonant-tunneling devices

Resonant-tunneling devices in microelectronic component form, whose structure is the electron analog of a Fabry-Perot resonator, encompass oscillators, self-oscillating mixers, and harmonic multipliers. The negative differential resistance characteristic of these devices has been obtained at room temperature, and resonant-tunneling transistors capable of operation in the THz-frequency range appear to be feasible. Three-terminal resonant-tunneling device development is in its infancy, as is that of devices for digital applications.

Sollner, T. C. L. Gerhard↗

Efficient Power Amplifier for Motor Control

Pulse-width-modulated amplifier supplies high current as efficiently as low current needed for starting and running motor. Key to efficiency of motor-control amplifier is V-channel metal-oxide/semiconductor transistor Q1. Device has low saturation resistance. However, has large gate input capacitance and small margin between its turn-on voltage and maximum allowable gate-to-source voltage. Circuits for output stages overcome limitations of VMOS device.

Brown, R. J.↗

Exploration Exercise System (EES) Physiology

Exploration class missions will be required to have an exercise device that is lightweight, has a small footprint, and is capable of providing enough physical stimulus and exercise variability to be an effective countermeasure against muscle, bone, aerobic fitness, and sensorimotor loss that results from the microgravity environment. Ground studies, inflight studies, and results analyses are required to inform Moon2Mars Design Reference Missions (DRMs) and vehicle designs. This activity encompasses two related projects, an evaluation study called Zero T2 and a requirements development for an exploration treadmill (ET). Exploration class missions’ mass/power/volume restrictions have resulted in the development of exercise devices that are motorized and flywheel-based to provide both aerobic and resistive training on one platform. These devices provide a variety of full body resistance exercise options as well as rowing and cycling for aerobic exercise, but do not provide ambulatory exercise via a treadmill. Because a treadmill has been available for use on the ISS since 2001, we do not understand the efficacy of exploration exercise modalities on muscle performance, aerobic fitness, bone health, or sensorimotor performance. A retrospective study was performed to quantify the association between total exercise (including specific contributions of treadmill exercise) and functional performance upon landing. Due to the relatively small variation in treadmill usage inflight, there is a need to do a controlled study where inflight crewmembers will not use the ISS treadmill (called T2) for the duration of their flights. There will be 3 arms to the Zero T2 study: 1) participants use all currently available exercise platforms aboard ISS (control group), 2) participants use only ARED and CEVIS, and 3) participants use only European Enhanced Exploration Device (E4D). (Please see the TechPort Entry for Exploration Exercise System Development for further detail on the E4D.) This study started in Oct 2020 and will continue through Sep 2027. In a parallel effort, a team will be developing requirements for an exploration treadmill. This project will be broken into two phases. Phase 1 will develop and implement energy prediction models based on available in-flight exercise data to quantify energy expenditure during 0g treadmill running. Phase 2 will then use the available biomechanical and metabolic evidence from Phase 1 to determine the hardware specification requirements essential to providing the desired exercise stimulus. Subject Matter Experts (SMEs) will then leverage the Standardized Process for Evaluating Exercise Devices (SPEED) developed by the team to 1) assess available technologies for candidate treadmills which meet defined requirements, 2) perform hands-on evaluations of top candidates, 3) provide evaluation outcomes and recommendations to developers. This project will begin in 2025 and continue through Sep 2030.

Kent Lawrence Kalogera↗

Flex-gear electrical power transmission

This study was conducted to develop an alternative way of transferring electricity across a continuously rotating joint, with little wear and the potential for low electrical noise. The problems with wires, slip rings, electromagnetic couplings, and recently invented roll-rings are discussed. Flex-gears, an improvement of roll-rings, are described. An entire class of flexgear devices is developed. Finally, the preferred flex-gear device is optimized for maximum electrical contact and analyzed for average mechanical power loss and maximum stress. For a device diameter of six inches, the preferred device is predicted to have a total electrical contact area of 0.066 square inches. In the preferred device, a small amount of internal sliding produces a 0.003 inch-pound torque that resists the motion of the device.

Vranish, John↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight on Astronaut Health and Performance

INTRODUCTION Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis missions to the Moon and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive capabilities on one platform without including a treadmill. The European Enhanced Exploration Exercise Device [E4D] is one such apparatus. It is critical to validate the efficacy of using exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the effectiveness of using nominal ISS exercise devices for an entire mission compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS Crewmembers are assigned to one of three groups: 1) Controls (n ≥ 40), who partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), cycling on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who exercise on the CEVIS and ARED only (n = 8); and 3) Active Group 2, who perform aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both Active groups are not permitted to perform treadmill exercise for the entirety of their flight. Health and performance markers, including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and after spaceflight. RESULTS Fifteen subjects (4 Active [CEVIS + ARED], 11 Control) have been recruited. Data collection is ongoing. CONCLUSIONS This study will assess the efficacy of using exploration exercise modalities, including removing the treadmill exercise capability or exclusively using the E4D, compared to the nominal ISS exercise regimen across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions. Supported by the NASA Human Research Program and NASA Exploration Capabilities