Ogo 4 observations of extremely low frequency hiss.

Analysis of ELF and VLF data from the Stanford University experiment on Ogo 4 revealed an ELF hiss band with characteristics not previously identified. The band, referred to as band-limited ELF hiss, is seen from low to medium latitudes. On the basis of wave-propagation properties, it is proposed that the BLH is generated at large wave normal angles in the equatorial region near L = 4. This model can be used to explain the characteristics of the BLH. Two mechanisms for the generation of BLH based on radiation from energetic electrons are considered.

Muzzio, J. L. R.↗

Report of the 90-day study on human exploration of the Moon and Mars

The basic mission sequence to achieve the President's goal is clear: begin with Space Station Freedom in the 1990's, return to the Moon to stay early in the Next century, and then journey to Mars. Five reference approaches are modeled building on past programs and recent studies to reflect wide-ranging strategies that incorporate varied program objectives, schedules, technologies, and resource availabilities. The reference approaches are (1) balance and speed; (2) the earliest possible landing on Mars; (3) reduce logistics from Earth; (4) schedule adapted to Space Station Freedom; and (5) reduced scales. The study and programmatic assessment have shown that the Human Exploration Initiative is indeed a feasible approach to achieving the President's goals. Several reasonable alternatives exist, but a long-range commitment and significant resources will be required. However, the value of the program and the benefits to the Nation are immeasurable.

Aaron Cohen↗

Commercial Systems Validation Overview

The Commercial Systems Validation Laboratory (CSVL) is composed of the 1) Virtual Product Laboratory (VPL), 2) Commercial Instrument Validation Laboratory (CIVL), and 3) In-Flight Verification & Validation Network (IVVN). All three laboratories are described in this viewgraph presentation, which covers the characterization of CCD cameras, hyperspectral sensors, ground reference equipment, and the Multispectral Thermal Imager (MTI). The presentation also includes sections on thermal modeling, measurements taken from a float, and the Scientific Data Purchase (SDP) Program. The section of the SDP profiles four data providers: 1) EarthSat; 2) Intermap; 3) Positive Systems; 4) Space Imaging.

Ryan, Robert↗

Relativistic MR-MP Energy Levels for L-shell Ions of Sulfur and Argon

Calculated level energies for valence and K-vacancy states are given for the ion series S vii–S xiv and Ar ix–Ar xvi. The calculations were performed with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method (MR-MP). The data set includes all the level energies with configurations $1{s}^{2}2{(s,p)}^{q}$, $1{s}^{2}2{(s,p)}^{q-1}{nl}$, $1{s}^{1}2{(s,p)}^{q+1}$, $1{s}^{1}2{(s,p)}^{q}{nl}$, $2{(s,p)}^{q+2}$, and $2{(s,p)}^{q+1}{nl}$, where 1 ≤ q ≤ 8, n ≤ 5, and l ≤ 3. We have compared our results with data from the National Institute of Standards and Technology (NIST) online database and with previous calculations. The average deviation of valence level energies ranges from 0.16 eV in Ne-like ions to 0.01 eV in Li-like ions, demonstrating that the present MR-MP valence level energies are highly accurate. In the case of K-vacancy states, the deviation is generally below 0.3 eV for Li-like S xiv and Ar xvi. The deviation for K-vacancy energies in other L-shell ions (Be-, B-, C-, N-, and O-like Ar ions) is higher but likely because the NIST-recommended values have a higher uncertainty. The data set includes many n = 4 and n = 5 valence and K-vacancy levels in L-shell ions of S and Ar that have not been previously reported. The data can be used for line identification and modeling of L-shell ions of S and Ar in astrophysical and laboratory-generated plasmas, and as energy references in the absence of more accurate laboratory calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal performance of 625-kg/cu m elastomeric ablative materials on spherically blunted 0.44-radian cones

Spherically blunted 0.44-radian (25 deg) half-angle conical models coated with elastomeric ablative materials were tested in supersonic arc-heated wind tunnels to evaluate performance of the ablators over a range of conditions typical of lifting entry. Four test conditions were combinations of stagnation point-heat transfer rates of 2.3 and 4.5 MW/m2 and stagnation pressures of 20 and 2kN/m2. Afterbody values of heat transfer rate and pressure were 0.05 to 0.20 of stagnation point values. Stagnation enthalpy varied from 4.4 to 25 MJ/kg (1900 to 11000 Btu/lbm) and free-stream Mach number was in a range from 3.5 to 4. Ablative materials retained the spherical nose shape throughout tests at the lower heat transfer level, but receded, assuming a flattened nose shape, during tests at the high heat transfer level. The residue layer that formed on the conical after-body was weak, friable, and extensively cracked. The reference ablative material, which contained phenolic microspheres, generally retained the conical shape on the model afterbody. However, a modified ablator, in which phenolic microspheres were replaced with silica microspheres, deformed and separated from the undegraded material, and thereby produced a very uneven surface. Substrate temperatures and ablator recession were in good agreement with values computed by a numerical analysis.

Champman, A. J.↗

{sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relativistic effects in ab initio electron-nucleus scattering

The electromagnetic responses obtained from Green's function Monte Carlo (GFMC) calculations are based on realistic treatments of nuclear interactions and currents. The main limitations of this method comes from its nonrelativistic nature and its computational cost, the latter hampering the direct evaluation of the inclusive cross sections as measured by experiments. We extend the applicability of GFMC in the quasielastic region to intermediate momentum transfers by performing the calculations in a reference frame that minimizes nucleon momenta. Additional relativistic effects in the kinematics are accounted for employing the two-fragment model. In addition, we developed a novel algorithm, based on the concept of first-kind scaling, to compute the inclusive electromagnetic cross section of 4 He through an accurate and reliable interpolation of the response functions. A very good agreement is obtained between theoretical and experimental cross sections for a variety of kinematical setups. Finally, this offers a promising prospect for the data analysis of neutrino-oscillation experiments that requires an accurate description of nuclear dynamics in which relativistic effects are fully accounted for.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Review Report for the "Justification for Small Gram Quantity Contents" Safety Analysis Report for Packaging Model 9977-96, Addendum 3, S-SARA-G-00006, Revision 4

This Technical Review Report (TRR) summarizes the results of the Staff’s review of the Model 9977-96 Package, Addendum 3, Revision 4 for the Type 4 contents. Type 4 contents may include 238 Pu, 239 Pu, 241 Am, 244 Cm, 252 Cf, 90 Sr, 226 Ra, 137 Cs, 60 Co, 192 Ir with the Special Actinide Isotopes ( 242 mAm, 243 Cm, 245 Cm, 247 Cm, 249 Cf and 251 Cf) limited to a total of 1000 ppm. Type 4 pertains primarily to the Off-Site Source Recovery Project (OSRP). These new contents will be authorized for shipment in the Model 9977-96 Package, supplementing existing Revision 2 to the Safety Analysis Report for Packaging (SARP), once Addendum 3, Justification for Small Gram Quantity (SGQ) Contents, is accepted by the certifying official, EM-40, and the existing Certificate of Compliance (CoC) is revised, reflecting the added contents. Existing Content Envelopes for the Model 9977-96 Package include heat sources in food-pack cans or in radioisotope thermoelectric generators (RTGs), neptunium metal, a beryllium-reflected plutonium ball, plutonium/uranium metal at 25% and 50% maximum 240Pu, respectively, and uranium metal at limits of 95% and 100% 235U, respectively. The percentages are of total radioactive material mass. The Isentropic Compression Experiment (ICE) apparatus is an additional content of the Model 9977-96 Package SARP. The latest content added to the Model 9977-96 Package is Type 5, AGR fuel compacts. Addendum 3 was prepared by Savannah River Packaging Technology, Savannah River National Laboratory, Savannah River Nuclear Solutions, LLC, Savannah River Site, in support of work being performed by LANL. The Model 9977-96 Package is currently certified under two Certificate of Compliance Numbers, i.e., USA/9977/B(M)F-96 (DOE) and USA/9977/B(M)F-96 (DOE-S/T-1), covering transportation and periodic and extended maintenance, respectively. For transportation, the Safety Analysis Report for Packaging is S-SARP-G-0001, Revision 2 (August 2007). Extended maintenance is covered by Addendum 1, Justification for DNDO Contents, S-SARA-G-00003, Revision 2 (October 2008). The new Content Envelope and container configurations will be incorporated into the next revision to the Model 9977-96 Package SARP. This TRR addresses only Type 4 contents; content Types 1, 2, and 3 will be covered under a separate TRR. Content Type 5 has been dealt with in a previous TRR. Hereafter, in this TRR, the Type 4 content may be referred to as Sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

FY2015 ceramic fuels development annual highlights

Key challenges for the Advanced Fuels Campaign are the development of fuel technologies to enable major increases in fuel performance (safety, reliability, power and burnup) beyond current technologies, and development of characterization methods and predictive fuel performance models to enable more efficient development and licensing of advanced fuels. Ceramic fuel development activities for fiscal year 2015 fell within the areas of 1) National and International Technical Integration, 2) Advanced Accident Tolerant Ceramic Fuel Development, 3) Advanced Techniques and Reference Materials Development, and 4) Fabrication of Enriched Ceramic Fuels. High uranium density fuels were the focus of the ceramic fuels efforts. Accomplishments for FY15 primarily reflect the prioritization of identification and assessment of new ceramic fuels for light water reactors which have enhanced accident tolerance while also maintaining or improving normal operation performance, and exploration of advanced post irradiation examination techniques which will support more efficient testing and qualification of new fuel systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY2016 Ceramic Fuels Development Annual Highlights

Key challenges for the Advanced Fuels Campaign are the development of fuel technologies to enable major increases in fuel performance (safety, reliability, power and burnup) beyond current technologies, and development of characterization methods and predictive fuel performance models to enable more efficient development and licensing of advanced fuels. Ceramic fuel development activities for fiscal year 2016 fell within the areas of 1) National and International Technical Integration, 2) Advanced Accident Tolerant Ceramic Fuel Development, 3) Advanced Techniques and Reference Materials Development, and 4) Fabrication of Enriched Ceramic Fuels. High uranium density fuels were the focus of the ceramic fuels efforts. Accomplishments for FY16 primarily reflect the prioritization of identification and assessment of new ceramic fuels for light water reactors which have enhanced accident tolerance while also maintaining or improving normal operation performance, and exploration of advanced post irradiation examination techniques which will support more efficient testing and qualification of new fuel systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heating of minor ions by the coronal slow shock

The coronal slow shock has been predicted to exist embedded in large coronal holes at 4-10 solar radii. In this paper, a three-fluid model is used to study the jumps in minor ion properties across a slow shock such as the coronal slow shock. The jump conditions are formulated in the de Hoffmann-Teller frame of reference. The Rankine-Hugoniot solution determines the MHD flow and the magnetic field across the shocks. For each minor ion species, the fluid equations for the conservation of mass, momentum, and energy can be solved to determine the velocity and the temperature of the ions across the shock. Also obtained is a similarity solution for heavy ions. The results show that, on the downstream side of the slow shock, the ion temperatures are nearly proportional to the ion masses for He, O, Si, and Fe, in agreement with observed ion temperatures in the inner solar wind. This indicates that the possibly existing coronal slow shock can be responsible for the observed heating of minor ions in the solar wind.

Whang, Y. C.↗

Comparison of Modal Analysis Methods Applied to a Vibro-Acoustic Test Article

Modal testing of a vibro-acoustic test article referred to as the Aluminum Testbed Cylinder (ATC) has provided frequency response data for the development of validated numerical models of complex structures for interior noise prediction and control. The ATC is an all aluminum, ring and stringer stiffened cylinder, 12 feet in length and 4 feet in diameter. The cylinder was designed to represent typical aircraft construction. Modal tests were conducted for several different configurations of the cylinder assembly under ambient and pressurized conditions. The purpose of this paper is to present results from dynamic testing of different ATC configurations using two modal analysis software methods: Eigensystem Realization Algorithm (ERA) and MTS IDEAS Polyreference method. The paper compares results from the two analysis methods as well as the results from various test configurations. The effects of pressurization on the modal characteristics are discussed.

Pritchard, Jocelyn↗

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Reference Model 3 Full Scale Geometry (RM3: Wave Point Absorber)

Contains the Reference Model 3 (RM3) full scale geometry files of the Wave Point Absorber, developed by the Reference Model Project (RMP). These full scale geometry files are saved as SolidWorks assembly, IGS, and STEP files, and require a CAD program to view. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 3 (RM3) is a wave point absorber, also referred to as a wave power buoy, that was designed for a reference site located off the shore of Eureka in Humboldt County, California. The design of the device consists of a surface float that translates (oscillates) with wave motion relative to a vertical column spar buoy, which connects to a subsurface reaction plate. This two-body point absorber converts wave energy into electrical power predominately from the device's heave oscillation induced by incident waves; the float is designed to oscillate up and down the vertical shaft up to 4 m. The bottom of the reaction plate is about 35 m below the water surface. The device is targeted for deployment in water depths of 40 m to 100 m. The point absorber is also connected to a mooring system to keep the floating device in position.

16 TIDAL AND WAVE POWER↗

CMIP6-based Multi-model Hydroclimate Projection over the Conterminous US

We present a suite of high-resolution downscaled hydro-climate projections over the conterminous United States (CONUS) based on a six-member General Climate Model (GCM) ensemble from the Coupled Models Intercomparison Project phase 6 (CMIP6). The CMIP6 GCMs are downscaled using two different downscaling approaches (statistical-based DBCCA & dynamical-based RegCM) based on two meteorological reference observations (Daymet & Livneh), and then fed to two calibrated hydrologic models (VIC & PRMS) to simulate projected future hydrologic responses. Each ensemble member covers 1980–2019 in the historic period and 2020–2059 in the near-term future period under the high-end (SSP585) emission scenario. Major variables such as daily maximum temperature (tmax), daily minimum temperature (tmin), daily total precipitation (prcp), daily average wind speed (wind), and daily total runoff (runoff) at 1/24° (~4 km) spatial resolution across the CONUS are provided through this data portal. This dataset is derived to support the SECURE Water Act Section 9505 Assessment for the US Department of Energy (DOE) Water Power Technologies Office (WPTO). Further details of this dataset can be referred to Kao et al. (2022) and Rastogi et al. (2022).

13 HYDRO ENERGY↗

Reference Model 3 Scaled Geometry (RM3: Wave Point Absorber)

Contains the Reference Model 3 (RM3) scaled scale geometry files of the Wave Point Absorber, developed by the Reference Model Project (RMP). These scaled geometry files are saved as SolidWorks assembly, IGS, and STEP files, and require a CAD program to view. The scaled RM3 device was tested at the Scripps Institution of Oceanography at the University of California at San Diego wave tank, details of which are described in the included test report. The scale of the geometries included in this submission are at a 1:33 scale compared to the full scale geometry. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 3 (RM3) is a wave point absorber, also referred to as a wave power buoy, that was designed for a reference site located off the shore of Eureka in Humboldt County, California. The design of the device consists of a surface float that translates (oscillates) with wave motion relative to a vertical column spar buoy, which connects to a subsurface reaction plate. This two-body point absorber converts wave energy into electrical power predominately from the device?s heave oscillation induced by incident waves; the float is designed to oscillate up and down the vertical shaft up to 4 m. The bottom of the reaction plate is about 35 m below the water surface. The device is targeted for deployment in water depths of 40 m to 100 m. The point absorber is also connected to a mooring system to keep the floating device in position.

16 TIDAL AND WAVE POWER↗

A computer program for anisotropic shallow-shell finite elements using symbolic integration

A FORTRAN computer program for anisotropic shallow-shell finite elements with variable curvature is described. A listing of the program is presented together with printed output for a sample case. Computation times and central memory requirements are given for several different elements. The program is based on a stiffness (displacement) finite-element model in which the fundamental unknowns consist of both the displacement and the rotation components of the reference surface of the shell. Two triangular and four quadrilateral elements are implemented in the program. The triangular elements have 6 or 10 nodes, and the quadrilateral elements have 4 or 8 nodes. Two of the quadrilateral elements have internal degrees of freedom associated with displacement modes which vanish along the edges of the elements (bubble modes). The triangular elements and the remaining two quadrilateral elements do not have bubble modes. The output from the program consists of arrays corresponding to the stiffness, the geometric stiffness, the consistent mass, and the consistent load matrices for individual elements. The integrals required for the generation of these arrays are evaluated by using symbolic (or analytic) integration in conjunction with certain group-theoretic techniques. The analytic expressions for the integrals are exact and were developed using the symbolic and algebraic manipulation language.

Andersen, C. M.↗