Search NASA⌕ Search

NASA NTRS · 20240006190

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Abstract

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Garima Raheja, James Nimo, Emmanuel K.-E. Appoh, Benjamin Essien, Maxwell Sunu, John Nyante, Mawuli Amegah, Reginald Quansah, Raphael E. Arku, Stefani L. Penn, Michael R. Giordano, Zhonghua Zheng, Darby Jack, Steven Chillrud, Kofi Amegah, R. Subramanian, Robert Pinder, Ebenezer Appah-Sampong, Esi Nerquaye Tetteh, Mathias A. Borketey, Allison Felix Hughes, Daniel M. Westervelt. 2024-07-12. Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana. https://ntrs.nasa.gov/citations/20240006190

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Convective Influence on the Humidity and Clouds in the Tropical Tropopause Layer During Boreal Summer

The impact of convection on the humidity and clouds in the tropical tropopause layer (TTL) during boreal summer 2007 is investigated in simulations of detailed cloud microphysical processes and their effects on the water vapor (H2O) profile along backward trajectories from the 379 K potential temperature (100‐hPa pressure) surface. Convective influence is determined by tracing the trajectories through time‐dependent fields of satellite‐based convective cloud top height. The simulated H2O mixing ratios at the 100‐hPa level and cloud occurrence fractions in the middle to upper (16–18 km) TTL exhibit a pronounced maximum over the Asian monsoon region as in observations; these local enhancements are virtually absent in the simulation without convection, indicating that convection is the dominant driver of the localized H2O and cloud maxima in the Asian summer monsoon region. Convection moistens the 100‐hPa level by 0.6 ppmv (~15%) averaged over the 10°S–50°N domain and increases tropical (10°S–30°N) mean cloud occurrence in the middle to upper TTL by ~170%. Nearly all of the convective enhancements in H2O and clouds are due to the effect of convective saturation; convectively detrained ice crystals have negligible impact. Parcels are most frequently hydrated by deep convection in the southern sector of the Asian monsoon anticyclone and subsequently dehydrated downstream of convection to the west, shifting the locations of final dehydration northwest of the cold temperature region in the northern Tropics. Infrequent, extreme deep convective systems (cloud tops exceeding 380 K) have a disproportionately large effect on TTL humidity and clouds.

Humidity↗

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity↗

Humidity Measurements at NASA Glenn Research Center Wind Tunnels

This presentation reviews the humidity measurements systems used at the large-scale wind tunnels at the NASA Glenn Research Center (as of July 2023), including the 9- by 15-Foot Low Speed Wind Tunnel, 8- by 6-Foot Supersonic Wind Tunnel, and the 10- by 10-Foot Supersonic Wind Tunnel. Effects of hygrometer accuracy and saturation vapor pressure model choice on Mach number are also investigated. Information in this presentation is intended for discussion with the AETC-supported Wind Tunnel Characterization Working Group during the 2023 Face-to-Face Meetings July 25-27 at NASA Glenn Research Center.

Humidity↗