Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modulair-PM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗

Measurement of particulated matter (PM1, PM2.5, PM10) using a PM sensor during the SAIL campaign in Gothic, CO and Mt. Crested Butte, CO

We deployed another PM sensor (Modulair-PM, QuantAQ) to measure the mass concentration of particulate matter (PM) for three size cuts at both the main site (M1) and supplementary site (S2) of the SAIL from 14 June 2022 to 14 June 2023. The instruments provide the mass concentration of PM1, PM2.5 and PM10. Mass concentrations were calculated based on measurements made with a nephelometer and an OPC. We used Quant-AQ's algorithm [please see their documentation here and the references within] to determine the mass concentrations reported. Here, we present the time series of sample relative humidity, temperature, pressure, and the mass concentration of PM1, PM2.5 and PM10. We also present the size distribution of the aerosol particles within a diameter range of 0.35 - 40 micron, measured by the OPC of the pm-modulair. However, we encourage caution while using the size distribution data, since it is operated only with the factory calibration. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2022ssb.

54 ENVIRONMENTAL SCIENCES↗