Search NASA⌕ Search

SEARCH · Search NASA

Results for “SENSOR CHARACTERISTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Earth Observing System instrument performance - Moderate Resolution Imaging Spectrometer case study

The requirements for characterization and calibration of instruments for the Earth Observing System space segment are defined in terms of tracking the Level 1 data for a sensor. The data must be traceable over the 15 year program, and must provide corrections for radiometric, spectral and geometric coefficients which capture the combined design and performance characteristics of the sensor. These requirements are then developed for MODIS-N to identify a set of techniques which can be used in the laboratory, spacecraft integrator's facility and in-orbit. The in-orbit of the so-called reflectance and radiance methods are reviewed, and the cross-calibrations available between HIRIS and MODIS through these techniques are listed. A scheme for the use of all available tools for instrument performance is provided as a Figure showing an estimated time interval over which each tool is expected to be useful. The final calibration strategy and plan must be developed through the understanding of a useful strategy for each of these candidate mechanisms.

Guenther, Bruce W.↗

Tracking Object Existence From an Autonomous Patrol Vehicle

An autonomous vehicle patrols a large region, during which an algorithm receives measurements of detected potential objects within its sensor range. The goal of the algorithm is to track all objects in the region over time. This problem differs from traditional multi-target tracking scenarios because the region of interest is much larger than the sensor range and relies on the movement of the sensor through this region for coverage. The goal is to know whether anything has changed between visits to the same location. In particular, two kinds of alert conditions must be detected: (1) a previously detected object has disappeared and (2) a new object has appeared in a location already checked. For the time an object is within sensor range, the object can be assumed to remain stationary, changing position only between visits. The problem is difficult because the upstream object detection processing is likely to make many errors, resulting in heavy clutter (false positives) and missed detections (false negatives), and because only noisy, bearings-only measurements are available. This work has three main goals: (1) Associate incoming measurements with known objects or mark them as new objects or false positives, as appropriate. For this, a multiple hypothesis tracker was adapted to this scenario. (2) Localize the objects using multiple bearings-only measurements to provide estimates of global position (e.g., latitude and longitude). A nonlinear Kalman filter extension provides these 2D position estimates using the 1D measurements. (3) Calculate the probability that a suspected object truly exists (in the estimated position), and determine whether alert conditions have been triggered (for new objects or disappeared objects). The concept of a probability of existence was created, and a new Bayesian method for updating this probability at each time step was developed. A probabilistic multiple hypothesis approach is chosen because of its superiority in handling the uncertainty arising from errors in sensors and upstream processes. However, traditional target tracking methods typically assume a stationary detection volume of interest, whereas in this case, one must make adjustments for being able to see only a small portion of the region of interest and understand when an alert situation has occurred. To track object existence inside and outside the vehicle's sensor range, a probability of existence was defined for each hypothesized object, and this value was updated at every time step in a Bayesian manner based on expected characteristics of the sensor and object and whether that object has been detected in the most recent time step. Then, this value feeds into a sequential probability ratio test (SPRT) to determine the status of the object (suspected, confirmed, or deleted). Alerts are sent upon selected status transitions. Additionally, in order to track objects that move in and out of sensor range and update the probability of existence appropriately a variable probability detection has been defined and the hypothesis probability equations have been re-derived to accommodate this change. Unsupervised object tracking is a pervasive issue in automated perception systems. This work could apply to any mobile platform (ground vehicle, sea vessel, air vehicle, or orbiter) that intermittently revisits regions of interest and needs to determine whether anything interesting has changed.

Wolf, Michael↗

Spectral characterization of the LANDSAT Thematic Mapper sensors

The spectral coverage characteristics of the two thematic mapper instruments were determined by analyses of spectral measurements of the optics, filters, and detectors. The following results are presented: (1) band 2 and 3 flatness was slightly below specification, and band 7 flatness was below specification; (2) band 5 upper-band edge was higher than specifications; (3) band 2 band edges were shifted upward about 9 nm relative to nominal; and (4) band 4, 5, and 7 lower band edges were 16 to 18 nm higher then nominal.

Markham, B. L.↗

Perspectives in remote sensing in Brazil. An approach of the remote sensing applications to Earth resources surveys

Since the systematic use of earth surface data collection by orbital sensor systems started in 1972 with the launching of the North American LANDSAT satellite, a great effort has been made to assimilate, develop and transfer remote sensing technology (data acquisition and analysis) in its many applications in Brazil. The availability of sensor systems and existing data is considered approached, as well as those which will soon be available to the Brazilian researchers. The new systems of the LANDSAT-4, of the Columbia space shuttle and of the French satellites of the SPOT series are discussed. Some characteristics of the sensor system for the first Brazilian remote sensing satellite, to be launched by the end of the decade, are presented. Some LANDSAT-4 and SPOT simulation products are shown, emphasizing how the data obtained by these new satellites can be applied.

Parada, N. D. J.↗

Geometric accuracy assessment of Landsat-4 Thematic Mapper p-tapes

An analysis was performed on the P-format computer compatible tapes for the Landsat-4 Thematic Mapper (TM) scene 40109-15140 acquired November 2, 1982 over Washington, D.C. and environs. Three tests of sensor geometry were undertaken: (1) band-to-band registration, (2) line-to-line registration between swaths, and (3) geometric correction of sensor and spacecraft/ephemeris characteristics. The band-to-band and line-to-line registration was measured at one hundred pixel spacings along a line using the phase correlation image alignment method developed by Kuglin and Hines and adapted to a one-dimensional FFT correlation technique. The sensor and spacecraft geometric calibration analysis was checked by identifying 75 ground control points in the TM scene and on 1:24,000 topographic maps. A least squares fit of the gaps was computed and the vector offsets of the residuals was tabulated and plotted.

Bryant, N. A.↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone Under Microgravity

USA Several microgravity experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4 mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies ? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone on TEXUS36

Several pg experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1 998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone on TEXUS36

Several earlier (micro)g experiments have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed on the TEXUS36 flight (February 7, 1 998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Maran-goni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies f? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

VIIRS On-Orbit Calibration and Performance Update

The S-NPP VIIRS was launched on October 28, 2011 and activated on November 8, and then went through a series of intensive functional tests in order to establish the sensor's baseline characteristics and initial on-orbit performance. With the exception of large optical degradation in the NIR and SWIR spectral regions that is due to pre-launch mirror coating contamination, both the VIIRS instrument and its on-board calibrators continue to operate and function normally. With continuous dedicated effort, it is expected that most of the sensor calibration parameters will continue to meet their design requirements and that high quality data products will be continuously generated and used by the operational as well as research community.

On-Orbit↗

Temperature Variation Analysis of the STIM300 Inertial Measurement Unit

A key navigation instrument found on most autonomous and semi-autonomous platforms is the inertial measurement unit (IMU). This type of sensor is a combination of microelectromechanical systems (MEMS) that provide inertial information to the navigation system. Typical MEMS hardware include a gyroscope and an accelerometer (for rates and accelerations, respectively) within a single platform. The Near Earth Asteroid (NEA) Scout mission, slated to launch in October of 2018 (Author’s note: NEA Scout ultimately launch on November 16, 2022), carries an on-board IMU from Sensonor. This particular model has yet to see spaceflight, and questions about its on-orbit reliability remain. Dynamic tests were produced in the summer of 2016 by a visiting faculty member from Arkansas Tech University, Daniel Bullock. During these experiments, concerns about the noise characteristics of the sensor were raised, specifically relating to how temperature fluctuations affected the unit. It was found that the IMU took an extended period of time before reaching an internal steady state temperature. These tests often displayed large temperature variations, making the calculation of noise characteristics, such as bias drift, difficult to attribute entirely to noise. Static and dynamic tests were re-performed under more stringent constraints on temperature. Tests reported herein conclude that the IMU is adequately capable of providing inertial information for the NEA Scout mission.

Ivan Rodrigues Bertaska↗

A remotely interrogatable sensor for chemical monitoring

A new type of continuously operating, in-situ, remotely monitored sensor is presented. The sensor is comprised of a thin film array of magnetostatically coupled, magnetically soft ferromagnetic thin film structures, adhered to or encased within a thin polymer layer. The polymer is made so that it swells or shrinks in response to the chemical analyte of interest, which in this case is pH. As the polymer swells or shrinks, the magnetostatic coupling between the magnetic elements changes, resulting in changes in the magnetic switching characteristics of the sensor. Placed within a sinusoidal magnetic field the magnetization vector of the coupled sensor elements periodically reverses directions, generating magnetic flux that can be remotely detected as a series of voltage spikes in appropriately placed pickup coils. one preliminary sensor design consists of four triangles, initially spaced approximately 50 micrometers apart, arranged to form a 12 mm x 12 mm square with the triangle tips centered at a common origin. Our preliminary work has focused on monitoring of pH using a lightly crosslinked pH sensitive polymer layer of hydroxyethylmethacrylate and 2-(dimethylamino) ethylmethacrylate. As the polymer swells or shrinks the magnetostatic coupling between the triangles changes, resulting in measurable changes in the amplitude of the detected voltage spirits.

Non-NASA Center↗

Star field attitude sensor study for the Pioneer Venus spacecraft

The characteristics of a star field attitude sensor for use with the Pioneer Venus spacecraft are presented. The aspects of technical feasibility, system interface considerations, and cost of flight hardware development are discussed. The tradeoffs which relate to performance, design, cost, and reliability are analyzed. The configuration of the system for installation in the spacecraft is described.

Rudolf, W. P.↗

Impact of LANDSAT MSS sensor differences on change detection analysis

Differences in overall sensor response, due to both factors within the sensor system, and external factors such as atmospheric effects, must be dealt with before change detection techniques using image differencing can be successfully implemented. The approach used to be coregister data to a base, followed by between image scatterogram generation and evaluation, and image differencing. Data from LANDSAT 2 and 3 were registered to LANDSAT 4 data. The area was limited to a small protion of the scene near the City of Santa Cruz because this was the only area cloud and haze free on all the images. Visual examination of each image, as well as the between image scatterograms, provide information on radiometric characteristics of each sensor. The image differencing, after normalizing for radiometric differences, provides a visual depiction of geometric distortions.

Likens, W.↗

Fiber-optic instrumentation: Cryogenic sensor model description

An assessment and determination of technology requirements for developing a demonstration model to evaluate feasibility of practical cryogenic liquid level, pressure, and temperature sensors is presented. The construction of a demonstration model to measure characteristics of the selected sensor and to develop test procedures are discussed as well as the development of an appropriate electronic subsystem to operate the sensors.

Sharma, M. M.↗

Systems level feasibility study for the detection of extra-solar planets. Volume 1: Infrared interferometer (IRIS) known as the Stanford Concept

A sensor system for the direct detection of extrasolar planets from an Earth orbit is evaluated: a spinning, infrared interferometer (IRIS). It is shuttle deployed, free flying, requires no on-orbit assembly and no reservicing over a design life of five years. The sensor concept and the mission objectives are reviewed, and the performance characteristics of a baseline sensor for standard observation conditions are derived. A baseline sensor design is given and the enabling technology discussed. Cost and weight estimates are performed; and a schedule for an IRIS program including technology development and assessment of risk are given. Finally, the sensor is compared with the apodized visual telescope sensor (APOTS) proposed for the same mission. The major conclusions are: that with moderate to strong technology advances, particularly in the fields of long life cryogenics, dynamical control, mirror manufacturing, and optical alignment, the detection of a Jupiter like planet around a Sunlike star at a distance of 30 light years is feasible, with a 3 meter aperture and an observation time of 1 hour. By contrast, major and possibly unlikely breakthroughs in mirror technology are required for APOTS to match this performance.

Source record↗

Preferred Frequency Range, Technical Characteristics, and Interference Assessment for a Microwave Observatory of Subsurface and Subcanopy (MOSS) for 1 MHZ Bandwidth in the Frequency Range of 100-150 MHz

This document presents rationale for the frequency band selection, technical and operational characteristics of active spaceborne sensors in the Earth Exploration-Satellite Service (active), and interference assessment for a 1 MHz bandwidth sensor in the 100-150 MHz frequency range. The active spaceborne sensors expected to be operating in the frequency range of 100-150 MHz is the synthetic aperture radar (SAR) such as the MOSS. The technical characteristics, mission objectives, orbital parameters, design parameters, antenna characteristics, and preliminary interference assessment are given for MOSS. The purpose of the document is to provide rationale for the frequency band selection, technical characteristics of the active spaceborne sensor Microwave Observatory of Subsurface and Subcanopy (MOSS) that can be used to analyze the compatibility of active spaceborne sensors and other systems of 1 MHz bandwidth in the 100-150 MHz frequency band.

wideband SAR modes↗

Ocean Color Optical Property Data Derived from OCTS and POLDER: A Comparison Study

We describe our efforts in studying and comparing the ocean color data derived from the Japanese Ocean Color and Temperature Scanner (OCTS) and the French Polarization and Directionality of the Earth's Reflectances (POLDER). OCTS and POLDER were both on board Japan's Sun-synchronous Advanced Earth Observing Satellite (ADEOS-1) from August 1996 to June 1997, collecting about 10 months of global ocean color data. This provides a unique opportunity for developing methods and strategies for the merging of ocean color data from multiple ocean color sensors. In this paper, we describe our approach in developing consistent data processing algorithms for both OCTS and POLDER and using a common in situ data set to vicariously calibrate the two sensors. Therefore, the OCTS and POLDER-measured radiances are effectively bridged through common in situ measurements. With this approach in processing data from two different sensors, the only differences in the derived products from OCTS and POLDER are the differences inherited from the instrument characteristics. Results show that there are no obvious bias differences between the OCTS and POLDER-derived ocean color products, whereas the differences due to noise, which stem from variations in sensor characteristics, are difficult to correct. It is possible, however, to reduce noise differences with some data averaging schemes. The ocean color data from OCTS and POLDER can therefore be compared and merged in the sense that there is no significant bias between two.

Wang, Menghua↗