Search NASA⌕ Search

SEARCH · Search NASA

Results for “Static pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Three-dimensional compressible turbulent computations for a diffusing S-duct

The purpose of the present study was to evaluate the capability of the computational fluid dynamics computer program PARC3D to model flow in a typical diffusing subsonic S-duct, with strong secondary flows. This evaluation is needed to provide confidence in the analysis of aircraft inlets, which have similar geometries. The performance predictions include total pressure profiles, static pressures, velocity profiles, boundary layer data, and skin friction data. Flow in the S-duct is subsonic, and the boundary layers are assumed to be turbulent. The results for both H and O grid solutions, are compared with existing test data.

Smith, C. F.↗

Experimental Investigation of Crossing Shock Wave-Turbulent Boundary Layer-Bleed Interaction

Results of an experimental investigation of a symmetric crossing shock wave/turbulent boundary layer/bleed interaction are presented for a freestream unit Reynolds number of 1.68 x 10(exp 7)/m, a Mach number of 2.81, and deflection angles of 8 degrees. The data obtained in this study are bleed mass flow rate using a trace gas technique, qualitative information in the form of oil flow visualization, flow field Pitot pressures, and static pressure measurements using pressure sensitive paint. The main objective of this test is two-fold. First, this study is conducted to explore boundary layer control through mass flow removal near a large region of separated flow caused by the interaction of a double fin-induced shock wave and an incoming turbulent boundary layer. Also, a comprehensive data set is needed for computational fluid dynamics code validation.

Kim, Hyun↗

Description of a 2-Foot Hypersonic Facility at the Langley Research Center

This report describes the mechanical and aerodynamic features of a two-foot hypersonic facility at the Langley Research Center. The facility provides for the testing of aerodynamic models in the Mach number range between 3 and 7 at approximate Reynolds numbers between 0.5 x 10(exp 6) and 1.0 x 10(exp 6). The facility was designed to obtain the needed pressure ratio through the use of ejector nozzles. Compressors driving the ejectors operate continuously at a pressure ratio of 4 and thus give the facility a continuous running capability. Curves are presented to show the ranges of total temperature, total pressure, Reynolds number dynamic pressure, and static pressure available in the tunnel. The flow in the test section is suitable for model tests at all Mach numbers between 3 and 7, although the nozzle blocks were contoured for a Mach number of 6.

Stokes, George M.↗

Novel, Miniature Multi-Hole Probes and High-Accuracy Calibration Algorithms for their use in Compressible Flowfields

Two new calibration algorithms were developed for the calibration of non-nulling multi-hole probes in compressible, subsonic flowfields. The reduction algorithms are robust and able to reduce data from any multi-hole probe inserted into any subsonic flowfield to generate very accurate predictions of the velocity vector, flow direction, total pressure and static pressure. One of the algorithms PROBENET is based on the theory of neural networks, while the other is of a more conventional nature (polynomial approximation technique) and introduces a novel idea of local least-squares fits. Both algorithms have been developed to complete, user-friendly software packages. New technology was developed for the fabrication of miniature multi-hole probes, with probe tip diameters all the way down to 0.035". Several miniature 5- and 7-hole probes, with different probe tip geometries (hemispherical, conical, faceted) and different overall shapes (straight, cobra, elbow probes) were fabricated, calibrated and tested. Emphasis was placed on the development of four stainless-steel conical 7-hole probes, 1/16" in diameter calibrated at NASA Langley for the entire subsonic regime. The developed calibration algorithms were extensively tested with these probes demonstrating excellent prediction capabilities. The probes were used in the "trap wing" wind tunnel tests in the 14'x22' wind tunnel at NASA Langley, providing valuable information on the flowfield over the wing. This report is organized in the following fashion. It consists of a "Technical Achievements" section that summarizes the major achievements, followed by an assembly of journal articles that were produced from this project and ends with two manuals for the two probe calibration algorithms developed.

Rediniotis, Othon K.↗

Survey of Primary Flow Measurement Parameters at the NASA Langley Transonic Dynamics Tunnel

An assessment of the methods and locations used to measure the primary flow conditions in the NASA Langley Transonic Dynamics Tunnel was conducted during calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to R-134a. A survey of stagnation pressure, plenum static pressure, and stagnation temperature was undertaken at many pertinent locations in the settling chamber, plenum, and contraction section of the wind tunnel and these measurements were compared to those of the existing primary flow measurement systems. Local flow velocities were measured in the settling chamber using a pitot probe. Results illustrate that small discrepancies exist between measured primary tunnel flow conditions and the survey measurements. These discrepancies in tunnel stagnation pressure, plenum pressure, and stagnation temperature were found to be approximately +/- 1-3 psf and 2-3 degrees Fahrenheit. The propagation of known instrument errors in measured primary flow conditions and its impact on tunnel Mach number, dynamic pressure, flow velocity, and Reynolds number have been investigated analytically and shown to require careful attention when considering the uncertainty in measured test section conditions.

Piatak, David J.↗

Improvements in Modeling 90 degree Bleed Holes for Supersonic Inlets

The modeling of porous bleed regions as boundary conditions in computational fluid dynamics (CFD) simulations of supersonic inlet flows has been improved through a scaling of sonic flow coefficient data for 90deg bleed holes. The scaling removed the Mach number as a factor in computing the sonic flow coefficient and allowed the data to be fitted with a quadratic equation, with the only factor being the ratio of the plenum static pressure to the surface static pressure. The implementation of the bleed model into the Wind-US CFD flow solver was simplified by no longer requiring the evaluation of the flow properties at the boundary-layer edge. The quadratic equation can be extrapolated to allow the modeling of small amounts of blowing, which can exist when recirculation of the bleed flow occurs within the bleed region. The improved accuracy of the bleed model was demonstrated through CFD simulations of bleed regions on a flat plate in supersonic flow with and without an impinging oblique shock. The bleed model demonstrated good agreement with experimental data and three-dimensional CFD simulations of bleed holes.

Slater, John W.↗

Ice Crystal Icing Investigation on a Honeywell Uncertified Research Engine in an Altitude Simulation Icing Facility

A Honeywell Uncertified Research Engine was exposed to various ice crystal conditions in the NASA Glenn Propulsion Systems Laboratory. Simulations using NASA's 1D Icing Risk Analysis tool were used to determine potential inlet conditions that could lead to ice crystal accretion along the inlet of the core flowpath and into the high pressure compressor. These conditions were simulated in the facility to develop baseline conditions. Parameters were then varied to move or change accretion characteristics. Data were acquired at altitudes varying from 5 kft to 45 kft, at nominal ice particle Median Volumetric Diameters from 20 µm to 100 µm, and total water contents of 1 g/m3 to 12 g/m3. Engine and flight parameters such as fan speed, Mach number, and inlet temperature were also varied. The engine was instrumented with total temperature and pressure probes. Static pressure taps were installed at the leading edge of the fan stator, front frame hub, the shroud of the IGV, and first two rotors. Metal temperatures were acquired for vane stators 1-2. In-situ measurements of the particle size distribution were acquired three meters upstream of the engine forward fan flange and one meter downstream of the fan in the bypass in order to study particle break-up behavior. Cameras were installed in the engine to capture ice accretions at the leading edge of the fan stator, splitter lip, and inlet guide vane. Additional measurements acquired but not discussed in this paper include: high speed pressure transducers installed at the trailing edge of the first stage rotor and light extinction probes used to acquire particle concentrations at the fan exit stator plane and at the inlet to the core and bypass. The goal of this study was to understand key parameters of accretion, acquire particle break-up data aft of the fan, and generate a unique icing dataset for model and tool development. This work described in the paper focuses on the effect of particle break-up. It was found that there was significant particle break-up downstream of the fan in the bypass especially with larger initial particle sizes. The metal temperatures on the inlet guide vanes and stators show a temperature increase with increasing MVD. Accretion behavior was very similar across all test cases. However at the inlet guide vanes, the accretion decreased with increasing particle size.

Ashlie B Flegel↗

Delta Cp RMS and Shadowgraph Data from t11-0377 (ATAT)

The plots included in this NF-1676 were collected during a recent wind tunnel test at the 11’x11’ Transonic test section of the Unitary Plan Wind Tunnel. The data is not SBU or ITAR since the images are qualitative and do not share model measurements. The on-body data is Delta Cp RMS. The off-body data is Time-Variance of the Shadowgraph intensity. No tunnel conditions other than Mach, Alpha, Beta, and Tunnel Drive Speed (RPM) are shared. Most importantly, dynamic pressure and static pressure are not included.

Aerodynamics↗

Evaluation of F/A-18A HARV inlet flow analysis with flight data

The F/A-18A aircraft has experienced engine stalls at high angles-of-attack and yaw flight conditions which were outside of its flight envelope. Future aircraft may be designed to operate routinely in this flight regime. Therefore, it is essential that an understanding of the inlet flow field at these flight conditions be obtained. Due to the complex interactions of the fuselage and inlet flow fields, a study of the flow within the inlet must also include external effects. Full Navier-Stokes (FNS) calculations on the F/A-18A High Alpha Research Vehicle (HARV) inlet for several angles-of-attack with sideslip and free stream Mach numbers have been obtained. The predicted forebody/fuselage surface static pressures agreed well with flight data. The surface static pressures along the inlet lip are in good agreement with the numerical predictions. The major departure in agreement is along the bottom of the lip at 30 deg and 60 deg angle-of-attack where a possible streamwise flow separation is not being predicted by the code. The circumferential pressure distributions at the engine face are in very good agreement with the numerical results. The variation in surface static pressure in the circumferential direction is very small with the exception of 60 angle-of-attack. Although the simulation does not include the effect of the engine, it appears that this omission has a second order effect on the circumferential pressure distribution. An examination of the unsteady flight test data base has shown that the secondary vortex migrates a significant distance with time. In fact, the extent of this migration increases with angle-of-attack with increasing levels of distortion. The effects of the engine on this vortex movement is unknown. This implies that the level of flow unsteadiness increases with increasing distortion. Since the computational results represent an asymptotic solution driven by steady boundary conditions, these numerical results may represent an arbitrary point in time. A comparison of the predicted total pressure contours with flight data indicates that the numerical results are within the excursion range of the unsteady data which is the best the calculations can attain unless an unsteady simulation is performed.

Smith, C. Frederic↗

An experimental study of transonic flow about a supercritical airfoil

A series of experiments was conducted on flow fields about two airfoil models whose sections are slight modifications of the original Whitcomb supercritical airfoil section. Data obtained include surface static-pressure distributions, far-wake surveys, oil-flow photographs, pitot-pressure surveys in the viscous regions, and holographic interferograms. These data were obtained for different combinations of lift coefficient and free-stream Mach number, which included both subcritical cases and flows with upper-surface shock waves. The availability of both pitot-pressure data and density data from interferograms allowed determination of flow-field properties in the vicinity of the trailing edge and in the wake without recourse to any assumptions about the local static pressure. The data show that significant static-pressure gradients normal to viscous layers exist in this region, and that they persist to approximately 10% chord downstream of the trailing edge. Comparisons are made between measured boundary-layer properties and results from boundary-layer computations that employed measured static-pressure distributions, as well as comparisons between data and results of airfoil flow-field computations.

Spaid, F. W.↗

The Development of an 8-inch by 8-inch Slotted Tunnel for Mach Numbers up to 1.28

An 8-inch by 8-inch transonic tunnel model with test section slotted on two opposite walls was constructed in which particular emphasis -was given to the development of slot geometry, slot-flow reentry section, and short-diffuser configurations for good test-region flow and minimum total-pressure losses. Center-line static pressures through the test section, wall static pressures through the other parts of the tunnel, and total-pressure distributions at the inlet and exit stations of the diffuser were measured- With a slot length equal to two tunnel heights and 1/14 open-area-ratio slotted walls) a test region one tunnel height in length was obtained in which the deviation from the mean Mach number was less than +/- 0.01 up to Mach number 1.15. With 1/7 open-area-ratio slotted walls, a test region 0.84 tunnel heights in length with deviation less than +/- O.01 was obtained up to Mach number 1.26. Increasing the tunnel diffuser angle from 6.4 to 10 deg. increased pressure loss through the tunnel at Mach number 1.20 from 15 percent to 20 percent of the total pressure. The use of other diffusers with equivalent angles of 10 deg. but contoured so that the initial diffusion angle was less than 10 deg. and the final angle was 200 reduced the losses to as low as 16 percent. A method for changing the test-section Mach number rapidly by controlling the flow through a bypass line from the tunnel settling chamber to the slot-flow plenum chamber of the test section was very effective. The test-section Mach number was reduced approximately 5 percent in 1/8 second by bleeding into the test section a flow of air equal to 2 percent of the mainstream flow and 30 percent in 1/4 second with bleed flow equal to 10 percent of the mainstream flow. The rate of reduction was largely determined by the opening rate of the bleed-flow-control valve.

Little, B. H., Jr.↗

Effect of steady-state pressure distortion on flow characteristics entering a turbofan engine

Flow angle, static-pressure, and total-pressure distributions were measured in the passage ahead of a turbofan engine operating with inlet pressure distortion. Distortions were generated with five screen configurations and one solid plate configuration. The screens and solid plate were circumferential and mounted on a rotatable assembly. Reynolds Number Index upstream of the distortion device was maintained at 0.5, 0.35, or 0.2, and engine corrected low-rotor speeds were held at 6000 rpm and 8600 rpm. Near the engine inlet, flow angle was largest at the hub and increased as flow approached the engine. The magnitude of static-pressure distortion measured along the inlet-duct and extended bullet nose walls increased exponentially as the flow approached the engine. Wall static-pressure distortion was also a function of distortion harmonic.

Soeder, R. H.↗

Investigation of adaptive-wall wind tunnels with two measured interfaces

An adaptive wall wind tunnel with two measured interfaces has been studied using two interface static pressure measurements near the tunnel walls. An iterative procedure with static pressure measurements on two interfaces is described. The functional relationships of static pressure on two measured interfaces for the exterior region are presented. The convergence of the selected iterative procedure is proved analytically. The one-step convergence formulae are obtained and validated by the simulation of a numerical wind tunnel. Experimental investigation has been conducted with a two-dimensional airfoil model of NASA 0012 at a supercritical Mach number. The results have indicated that the selected procedure is feasible to speed up the flow convergence to the unconfined condition in applying the one-step convergence formulae.

Lo, C. F.↗

Wind Tunnel Model Design for the Study of Plume Effects on Sonic Boom for Isolated Exhaust Nozzles

A low cost test capability was developed at the NASA Glenn Research Center 1- by 1-Foot Supersonic Wind Tunnel (SWT), with a goal to reduce the disturbance caused by supersonic aircraft flight over populated areas. This work focused on the shock wave structure caused by the exhaust nozzle plume. Analysis and design was performed on a new rig to test exhaust nozzle plume effects on sonic boom signature. Test capability included a baseline nozzle test article and a wind tunnel model consisting of a strut, a nose cone and an upper plenum. Analysis was performed on the external and internal aerodynamic configuration, including the shock reflections from the wind tunnel walls caused by the presence of the model nosecone. This wind tunnel model was designed to operate from Mach 1.4 to Mach 3.0 with nozzle pressure ratios from 6 to 12 and altitudes from 30,000 ft (4.36 psia) to 50,000 ft (1.68 psia). The model design was based on a 1 in. outer diameter, was 9 in. in overall length, and was mounted in the wind tunnel on a 3/8 in. wide support strut. For test conditions at 50,000 ft the strut was built to supply 90 psia of pressure, and to achieve 20 psia at the nozzle inlet with a maximum nozzle pressure of 52 psia. Instrumentation was developed to measure nozzle pressure ratio, and an external static pressure probe was designed to survey near field static pressure profiles at one nozzle diameter above the rig centerline. Model layout placed test nozzles between two transparent sidewalls in the 1x1 SWT for Schlieren photography and comparison to CFD analysis.

Castner, Raymond S.↗

Wind Tunnel Model Design for the Study of Plume Effects on Sonic Boom for Isolated Exhaust Nozzles

A low cost test capability was developed at the NASA Glenn Research Center 1- by 1-Foot Supersonic Wind Tunnel (SWT), with a goal to reduce the disturbance caused by supersonic aircraft flight over populated areas. This work focused on the shock wave structure caused by the exhaust nozzle plume. Analysis and design was performed on a new rig to test exhaust nozzle plume effects on sonic boom signature. Test capability included a baseline nozzle test article and a wind tunnel model consisting of a strut, a nosecone and an upper plenum. Analysis was performed on the external and internal aerodynamic configuration, including the shock reflections from the wind tunnel walls caused by the presence of the model nosecone. This wind tunnel model was designed to operate from Mach 1.4 to Mach 3.0 with nozzle pressure ratios from 6 to 12 and altitudes from 30,000 ft (4.36 psia) to 50,000 ft (1.68 psia). The model design was based on a 1 in. outer diameter, was 9 in. in overall length, and was mounted in the wind tunnel on a 3/8 in. wide support strut. For test conditions at 50,000 ft the strut was built to supply 90 psia of pressure, and to achieve 20 psia at the nozzle inlet with a maximum nozzle pressure of 52 psia. Instrumentation was developed to measure nozzle pressure ratio, and an external static pressure probe was designed to survey near field static pressure profiles at one nozzle diameter above the rig centerline. Model layout placed test nozzles between two transparent sidewalls in the 1 1 SWT for Schlieren photography and comparison to CFD analysis.

Castner, Raynold S.↗

Effect of steady-state pressure distortion on inlet flow to a high-bypass-ratio turbofan engine

Static pressure and total pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. In addition, the free stream flow angle was measured between the distortion generator and the engine inlet. Distortions were generated using three screen configurations with extents of 90 deg or 180 deg. The screens were mounted on a rotatable screen assembly. Reynolds number index upstream of the distortion device was maintained at 0.5 or 0.2, and engine fan speed corrected to station 2 temperature was maintained at 80 or 90 percent of rated condition (7005 rpm). Flow angle was nearly constant near the distortion device and increased as flow approached the engine inlet. The largest flow angle occurred in the hub region of the engine inlet. Static pressure distortion along the inlet duct increased exponentially as the flow approached the engine. Both static pressure and total pressure distortions were attenuated between engine inlet and compressor exit.

Soeder, R. H.↗

Wind tunnel investigation of the Titan Forward Skirt compartment vent from a free-stream Mach number of 0.80 to 1.96

A test was conducted to determine the flow characteristics of the Titan forward skirt compartment vent over a free stream Mach number range of 0.80 to 1.96. The vent was mounted in a flat plate and the plate was flush mounted to the tunnel side wall with coinciding center lines. Air was discharged from a duct, located on the tunnel side wall behind the plate, through a canted aft 30 deg honeycomb vent into the free stream. Data for the analysis of the Titan forward skirt compartment venting during ascent through the atmosphere are provided. Full scale simulated flight hardware, such as the honeycomb vent, duct corrugations and field joint ring were used. Boundary layer thicknesses were used to vary boundary height. The highest vent discharge coefficient for any given Mach number and vent pressure ratio generally occurred at the maximum displacement thickness. With no vent flow the static pressure in the vent region was generally less than the free stream static pressure. With vent flow, the static pressures upstream of the vent increased, and those downstream of the vent decreased.

Johns, A. L.↗

Use of surface heat transfer measurements as a flow separation diagnostic in a two-dimensional reflected oblique shock/turbulent boundary layer interaction

The feasibility of using streamwise surface heat transfer measurements to detect the presence of flow separation in a two-dimensional reflected oblique shock/turbulent boundary layer interaction is reported. Surface heat transfer and static pressure data are presented for attached and separated flows for a free stream nominal Mach number range of 2.5 to 3.5 and shock generator angles of 2 to 8 degrees. The static presure data do show the characteristic triple inflection point distribution for the strongly separated flow cases. The corresponding surface heat transfer data show unique trends that correlate well with the static pressure determination of the extent of the separated flow region. For the incipient or weakly separated flow cases, the static pressure data do not exhibit the characteristic triple inflection point distribution. However, the same trends in the heat transfer data that are seen for the strongly separated flow cases are evident for the weakly separated flows. Hence, the heat transfer data can be used to determine the extent of weakly separated flows when the surface static pressure distributions often can not.

Porro, A. R.↗