Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (∆T ∙ ∆α) should be less than 189 ppm, where ∆T is the temperature excursion and ∆α is the difference in glass coefficient of thermal expansion. If the product (∆T ∙ ∆α) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets

42 ENGINEERING↗

Unraveling the Stable Cathode Electrolyte Interface in all Solid‐State Thin‐Film Battery Operating at 5 V

Abstract Spinel‐type LiNi 0.5 Mn 1.5 O 4 (LNMO) is one of the most promising 5 V‐class cathode materials for Li‐ion batteries that can achieve high energy density and low production costs. However, in liquid electrolyte cells, the high voltage causes continuous cell degradation through the oxidative decomposition of carbonate‐based liquid electrolytes. In contrast, some solid‐state electrolytes have a wide electrochemical stability range and can withstand the required oxidative potential. In this work, a thin‐film battery consisting of an LNMO cathode with a solid lithium phosphorus oxynitride (LiPON) electrolyte is tested and their interface before and after cycling is characterized. With Li metal as the anode, this system can deliver stable performance for 600 cycles with an average Coulombic efficiency >99%. Neutron depth profiling indicates a slight overlithiated layer at the interface prior to cycling, a result that is consistent with the excess charge capacity measured during the first cycle. Cryogenic electron microscopy further reveals intimate contact between LNMO and LiPON without noticeable structure and chemical composition evolution after extended cycling, demonstrating the superior stability of LiPON against a high voltage cathode. Consequently, design guidelines are proposed for interface engineering that can accelerate the commercialization of a high voltage cell with solid or liquid electrolytes.

25 ENERGY STORAGE↗

Document-Based Nuclear Archaeology

Deeper reductions in the nuclear arsenals will require better understanding of historic fissile material management and production. The concept of “nuclear archaeology” has been considered since the 1990s to provide the tools and methods to develop independent production estimates, primarily based on nuclear forensic techniques. Here, we propose to add a framework for reconstructing the history of a nuclear program that complements traditional nuclear archaeology techniques by examining the role of operating records to support such an effort. As a test case, we use the JEEP II reactor, a 2 MW civilian research reactor at Norway’s Institute for Energy Technology (IFE), in operation for more than fifty years, however, recently shut down permanently. We have collected, analyzed, and started to preserve the reactor’s operating records, which exist on both analog and digital media, and to simulate parts of its history using OpenMC/ONIX neutronics calculations. Here, a particular focus of this project has been on digital data curation and preservation to confirm and maintain the integrity, authenticity, and provenance of these records. In developing guidelines for best practices that conform to existing standards for long-term digital preservation and curation, we hope this project can help lay the basis for future nuclear archaeology efforts to support nuclear arms control and disarmament.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Optode performance data associated with: Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

This data package is associated with the publication “Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments”, submitted to PlosONE (Kaufman et al. 2023; 10.1101/2023.03.28.534656).We carried out many testing and calibration experiments on a system of small oxygen consumption batch reactors designed for use with water and sediment samples for environmental questions. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. Our primary focus was on practical considerations, such as temperature effects, lighting angle effects, sterilization, and other similar situations that a user may find useful. Most of the tests required comparing “base” calibration curves to “treatment” calibration curves to determine the extent to which the treatment impacted the reported measurements. This data package contains the performance and calibration data collected for that purpose.This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) diffusion test result files; (5) limit of detection test result files; (6) temperature impact files; (7) a main data file that contains test results for all other tests; and (8) an R script that uses Kolmogorov-Smirnov tests to determine whether treatment calibrations are significantly different from their respective base calibrations. All files are .csv, .txt, .Rmd, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Ethyl Formate as a Methyl Bromide Alternative for Fumigation of Citrus: Efficacy, Fruit Quality, and Workplace Safety

Abstract Ethyl formate (EF) was evaluated as a potential alternative to methyl bromide (MB) for phytosanitary treatment of imported citrus fruit in the Republic of Korea. Planococcus citri (Risso) (Hemiptera: Pseudococcidae), a mealybug with known tolerance against EF and MB, was used as a representative pest to test efficacy of the two fumigants against eggs. In nine commercial-scale refrigerated container (67.5 m3) trials using imported orange, lemon and grapefruit, EF applied at the currently approved dose for citrus (70 g·m-3 at 5°C for 4 h, developed for Aspidiotus excisus Green (Hemiptera: Diaspididae), a species less EF tolerant than P. citri) resulted in 76.9–98.3% mortality of P. citri eggs. The EF treatment did not affect the sugar content or the color of peel and pulp of the treated fruit. When oranges were treated according to the current MB (64 g·m-3 at >5°C for 2 h) or EF treatment guidelines, the concentration of fumigant around the fruit fluctuated between 9.4 and 185.1 ppm for EF and 9.5–203.0 ppm for MB during the 72-h post-fumigation processes (venting [0–2 h], transportation to storage [2–24 h], and storage periods [24–72 h]) with both EF and MB maintained between 10 and 100 ppm during the storage period. Considering the efficacy of EF, its apparent lack of phytotoxicity, and its more manageable threshold limit value for humans (100 ppm EF compared to 1 ppm MB for an 8-h time weighted average exposure), our results suggest that EF may be a promising alternative to MB for the phytosanitary treatment of imported citrus in Korea.

Entomology↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Design Guidelines and Specifications for DC Distribution-Based Charging Hub

Managed under U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to design and develop a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration and control approaches for a DC distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for DC-coupled charging hub ('DC hub' for short). This report explains the design, development, and implementation process of the experimental platform for the DC hub. The utilization of DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges establishing the DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products as well as novel, in-house designed solutions to evaluate different use cases at rated power and voltage levels.

33 ADVANCED PROPULSION SYSTEMS↗

Expanding standards in viromics: in silico evaluation of dsDNA viral genome identification, classification, and auxiliary metabolic gene curation

Viruses influence global patterns of microbial diversity and nutrient cycles. Though viral metagenomics (viromics), specifically targeting dsDNA viruses, has been critical for revealing viral roles across diverse ecosystems, its analyses differ in many ways from those used for microbes. To date, viromics benchmarking has covered read pre-processing, assembly, relative abundance, read mapping thresholds and diversity estimation, but other steps would benefit from benchmarking and standardization. Here we use in silico-generated datasets and an extensive literature survey to evaluate and highlight how dataset composition (i.e., viromes vs bulk metagenomes) and assembly fragmentation impact (i) viral contig identification tool, (ii) virus taxonomic classification, and (iii) identification and curation of auxiliary metabolic genes (AMGs). The in silico benchmarking of five commonly used virus identification tools show that gene-content-based tools consistently performed well for long (≥3 kbp) contigs, while k -mer- and blast-based tools were uniquely able to detect viruses from short (≤3 kbp) contigs. Notably, however, the performance increase of k -mer- and blast-based tools for short contigs was obtained at the cost of increased false positives (sometimes up to ~5% for virome and ~75% bulk samples), particularly when eukaryotic or mobile genetic element sequences were included in the test datasets. Furthermore, for viral classification, variously sized genome fragments were assessed using gene-sharing network analytics to quantify drop-offs in taxonomic assignments, which revealed correct assignations ranging from ~95% (whole genomes) down to ~80% (3 kbp sized genome fragments). A similar trend was also observed for other viral classification tools such as VPF-class, ViPTree and VIRIDIC, suggesting that caution is warranted when classifying short genome fragments and not full genomes. Finally, we highlight how fragmented assemblies can lead to erroneous identification of AMGs and outline a best-practices workflow to curate candidate AMGs in viral genomes assembled from metagenomes. Together, these benchmarking experiments and annotation guidelines should aid researchers seeking to best detect, classify, and characterize the myriad viruses ‘hidden’ in diverse sequence datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

This paper presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated widebandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode (CM) or differential mode (DM)). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility (EMC). However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This paper addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50Ω/50μH LISN with 1.5kV, 75A and 30MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300kVA MV EMI testbed.

42 ENGINEERING↗

Data and Scripts associated with “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling.”

This data package is associated with the publication “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling” submitted to Geoscientific Model Development (Muller et al., 2024). In this manuscript, organic matter chemistry and thermodynamics are directly connected to reactive transport simulators through the newly developed Lambda-PFLOTRAN (Parallel Reactive Flow and Transport model) workflow tool that succinctly incorporates organic matter chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate aerobic respiration of the organic matter and the resulting biogeochemistry. Lambda-PFLOTRAN is a python-based workflow, executed through a Jupyter Notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow, and transport code PFLOTRAN. This data package contains Jupyter Notebook based workflows for two test cases for running biogeochemical simulations of organic matter oxidation identified by FTICR-MS. It contains four primary folders (workflow, data, src, and analysis), a file-level metadata file (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_flmd.csv) that lists all the files contained in this data package with a short description of each, and a data dictionary (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_dd.csv) file that describes the tabular column headers. The ‘workflow’ folder contains the Jupyter Notebook based workflows for running the lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘data’ folder contains the FTICR-MS data, initial conditions, and incubation data for test cases 1 and 2 in folders titled ‘WHONDRS’ and ‘Colloids’, respectively. The data folder also has a ‘Database’ folder containing a reaction network for bulk organic matter (assumed to be CH2O) and a general database for PFLOTRAN (hanford_rxn_network). The CH2O reaction network defines bulk organic matter oxidation. Biogeochemical simulations are completed for both the lambda binned organic matter and bulk organic matter reaction networks. The ‘hanford_rxn_network’ database includes information required for PFLTORAN simulations including ion size, molar mass, and charge of the aqueous species, gases, and minerals phases. The ‘src’ folder contains python source codes for performing lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘analysis’ folder contains outputs from the test cases 1 and 2 including lambda analysis, PFLOTRAN runs and the calibration results.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Lost Circulation Material Particle-Size Distribution on Fracture Sealing: A Numerical Study

Summary Lost circulation materials (LCMs) are essential to combat fluid loss while drilling and may put the whole operation at risk if a proper LCM design is not used. The focus of this research is understanding the function of LCMs in sealing fractures to reduce fluid loss. One important consideration in the success of fracture sealing is the particle-size distribution (PSD) of LCMs. Various studies have suggested different guidelines for obtaining the best size distribution of LCMs for effective fracture sealing based on limited laboratory experiments or field observations. Hence, there is a need for sophisticated numerical methods to improve the LCM design by providing some predictive capabilities. In this study, computational fluid dynamics (CFD) and discrete element methods (DEM) numerical simulations are coupled to investigate the influence of PSD of granular LCMs on fracture sealing. Dimensionless variables were introduced to compare cases with different PSDs. We validated the CFD-DEM model in reproducing specific laboratory observations of fracture-sealing experiments within the model boundary parameters. Our simulations suggested that a bimodally distributed blend would be the most effective design in comparison to other PSDs tested here.

Engineering↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Cell Efficiency Tables (Version 66)

Consolidated tables showing an extensive listing of the highest independently confirmed efficiencies for solar cells and modules are presented. Guidelines for inclusion of results into these tables are outlined, and new entries since January 2025 are reviewed.

14 SOLAR ENERGY↗