Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Note: Simple calibration of the counting-rate dependence of the timing shift of single photon avalanche diodes by photon interval analysis

The counting-rate dependence of the temporal response of single photon avalanche diodes (SPADs) is a critical issue for the accurate determination of the fluorescence lifetime. In this study, the response of SPADs was examined with analyzing the time interval of the detected photons. The results clearly show that the shift of the detection timing causes the counting-rate dependence of the temporal response, and this timing shift is solely determined by the time interval from the preceding photon. We demonstrate that this timing instability is readily calibrated by utilizing the macrotime data taken with the time-tag mode that is implemented in the time-correlated single photon counting modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Consistent Pixel Resolution Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides global TOA shortwave and longwave fluxes for climate monitoring and validation that spans over 20 years. CERES utilizes broadband fluxes derived from geostationary (GEO) imagers to estimate broadband fluxes between the CERES observations. In order for these fluxes to be viable, the GEO imager calibration must be stable over time. One such calibration method used by CERES is to evaluate ensemble sets of deep convective clouds (DCC) as invariant targets (IT) over time. DCC targets can also provide radiometric scaling between sensors. An international collaboration through GSICS is also evaluating the DCC-IT calibration methodology to provide consistent calibration coefficients across geostationary sensors. Tropical DCC are the coldest, brightest, and most Lambertian TOA Earth targets identified using a window channel brightness temperature threshold. The DCC-IT technique involves a large ensemble of TOA pixel-level reflectances, which are binned into probability density functions (PDF). The PDF structure dependency on sensor pixel resolution, which can vary greatly among sensors, is not well known. This study will identify the impact of pixel resolution on the DCC PDFs by aggregating VIIRS and Landsat OLI/TIRS pixel resolutions into various coarser pixel resolutions and comparing the shape and statistics of the resulting PDFs. This study should assist in mitigating the pixel resolution dependency in the DCC-IT approach for providing scaling factors between sensors.

Conor Haney↗

Conditioning of MVM '73 radio-tracking data

An extensive effort was undertaken to edit Mariner 10 radiometric tracking data. Interactive computer graphics were used for the first time by an interplanetary mission to detect blunder points and spurious signatures in the data. Interactive graphics improved the former process time by a factor of 10 to 20, while increasing reliability. S/X dual Doppler data was used for the first time to calibrate charged particles in the tracking medium. Application of the charged particle calibrations decreased the orbit determination error for a short data arc following the 16 March 1974 maneuver by about 80%. A new model was developed to calibrate the earth's troposphere with seasonal adjustments. The new model has a 2% accuracy and is 5 times better than the old model.

Koch, R. E.↗

Two-dimensional imaging of thermal diffusivity in metals by scanning photodeflection detection

We present a technique that retrieves the thermal diffusivity of metallic samples in a two-dimensional map with micrometer resolution. The technique uses a photothermal method based on the deflection of a probe beam after heating the surface with a modulated pump. After adequate calibration, the time delay between the pump modulation and the deflection modulation provides direct information on the local thermal diffusivity. The calibration is carried out by measuring the frequency dependence of the deflection signal at several sample locations. The capabilities of the technique are illustrated with the measurement of a cross section of a surface treated steel sample.

36 MATERIALS SCIENCE↗

Advances in Digital Calibration Techniques Enabling Real-Time Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures, which promise significant increases in instrument capability for solid earth and biomass remote sensing. These new instrument concepts require new methods for calibrating the multiple channels, which are combined on-board, in real-time. The benefit of this effort is that it enables a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for reduced mass and cost. This paper will review the on-going development of the digital calibration architecture for digital beamforming radar instrument, such as the proposed Earth Radar Mission's DESDynI (Deformation, Ecosystem Structure, and Dynamics of Ice) instrument. This proposed instrument's baseline design employs SweepSAR digital beamforming and requires digital calibration. We will review the overall concepts and status of the system architecture, algorithm development, and the digital calibration testbed currently being developed. We will present results from a preliminary hardware demonstration. We will also discuss the challenges and opportunities specific to this novel architecture.

TR (Transmit/Receive)↗

Stepwise Dynamic Calibration of a Hydromechanical Simulation Using Time-Lapse Vertical Seismic Profile

This study aims to develop a methodology for calibrating subsurface stress changes through time-lapse Vertical Seismic Profiling (VSP) integration. The selected study site is the 13-10A injector well within the ongoing CO2-EOR operation of the Farnsworth Field Unit. The Time-lapse VSP dataset carries the combined effects of fluid substitution and mean effective stress changes, thereby providing a dataset amenable for the calibration of production and injection-induced stress changes. The concept is similar to calibrating a reservoir simulation model in that the process honor real field data to set up an inverse problem. The solution optimizes the independent and impactful geomechanical parameters that replicate the observed time-lapse seismic velocity changes. This stress calibration is enabled by 4D geomechanical modeling and the VSP Integration workflow. This calibration benefits from extensive geological, geophysical and geomechanical characterization through 3D seismic data, geophysical well logs, and core assessed as part of the 1D MEM conducted on the 13-10A subject well. These data are used to develop a site-specific rock physics model. The Biot Gassmann workflow combines rock physics and reservoir simulation outputs to determine the fluid substitution contribution to seismic velocity change. Additionally, modeled seismic velocity attributed to mean effective stress are determined from the geomechanical simulation outputs, and the stress-velocity relationship developed from the ultrasonic seismic velocity measurements on the extracted Morrow B core. A penalty function is then formed between the modeled seismic velocities and the observed time-lapse VSP dataset. Four independent and impactful geomechanical parameters have been determined. These are the bulk modulus and shear modulus for zero porosity and the shear and compressional seismic velocity to mean effective stress derivatives. The dataset of numerous coupled hydromechanical- geomechanical simulation realizations is built by combining variations of the four stated geomechanical parameters. A machine learning-assisted workflow comprised of an artificial neural network and a particle swarm optimizer are used to converge on the optimal geomechanical parameters. The successful execution of this workflow has affirmed the suitability of acoustic time-lapse measurements for 4D-VSP geomechanical stress calibration pending measurable stress sensitivities within the anticipated effective stress changes and the availability of suitable and reliable datasets for petroelastic modeling.

02 PETROLEUM↗

STELLAR LOCUS REGRESSION: ACCURATE COLOR CALIBRATION AND THE REAL-TIME DETERMINATION OF GALAXY CLUSTER PHOTOMETRIC REDSHIFTS

We present stellar locus regression (SLR), a method of directly adjusting the instrumental broadband optical colors of stars to bring them into accord with a universal stellar color-color locus, producing accurately calibrated colors for both stars and galaxies. This is achieved without first establishing individual zero points for each passband, and can be performed in real-time at the telescope. We demonstrate how SLR naturally makes one wholesale correction for differences in instrumental response, for atmospheric transparency, for atmospheric extinction, and for Galactic extinction. We perform an example SLR treatment of Sloan Digital Sky Survey data over a wide range of Galactic dust values and independently recover the direction and magnitude of the canonical Galactic reddening vector with 14-18 mmag rms uncertainties. We then isolate the effect of atmospheric extinction, showing that SLR accounts for this and returns precise colors over a wide range of air mass, with 5-14 mmag rms residuals. We demonstrate that SLR-corrected colors are sufficiently accurate to allow photometric redshift estimates for galaxy clusters (using red sequence galaxies) with an uncertainty {sigma}(z)/(1 + z) = 0.6% per cluster for redshifts 0.09 < z < 0.25. Finally, we identify our objects in the 2MASS all-sky catalog, and produce i-band zero points typically accurate to 18 mmag using only SLR. We offer open-source access to our IDL routines, validated and verified for the implementation of this technique, at http://stellar-locus-regression.googlecode.com.

79 ASTRONOMY AND ASTROPHYSICS↗

Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures

SweepSAR, a novel radar architecture that depends on a DBF (digital beamforming) array, requires calibration accuracies that are order(s) of magnitude greater than is possible with traditional techniques, such as a priori characterization of TR (transmit/receive) modules in thermal vacuum chambers, or simple loop-back of the calibration signal. The advantages of a SweepSAR architecture are so great that it is worth applying significant resources to calibration efforts. Due to the nature of the DBF, each channel contains a digitizer and very powerful digital processor. Each channel can independently digitize (with the digitizer) and analyze (with the processor) its channel's unique calibration signal, and extract the relevant calibration parameters, namely channel gain and channel phase delay commonly referred to as the gain (or amplitude) and phase of the channel. Using the processor, each channel's gain and phase can theoretically be estimated with arbitrary precision through averaging a sufficiently large number of samples. Systematic errors and the changing gain and phase of the channels, typically due to temperature drifts, limits how long the averaging can occur, which limits the precision of the calibration estimate. However, results indicate that calibration knowledge of both the transmit and receive chains of each TR module can be improved by one or two orders of magnitude. Due to the digital nature of the receiver data, the channel's gain and phase may be corrected by a similar amount, while the transmit chain can only be corrected in a traditional manner. To implement Sweep SAR, the order of magnitude improvement in the knowledge of the channel's gain and phase is needed, and the control of the receiver to a similar level is required. Inherent to the DBF array is the individual digitization of each of the array's receiver channels. Current systems typically combine all of the analog signals in the array into one or two analog channels, which are then digitized and processed. All signal conditioning performed prior to digitization is done using analog hardware (which is less precise than digital signal conditioning and dependent on temperature). The DBF digitizes every signal prior to combining, and can therefore analyze and correct received signals, as well as analyze signals that are being transmitted through analog hardware (by sampling a copy and digitizing). Each channel of a DBF also has a powerful processor. With this combination, one is able to digitize, analyze, and correct each channel prior to its being combined. A unique factor is the ability to digitize and analyze (in real time) each of the array's channels independently, allowing one to achieve unprecedented knowledge of each channel's performance (gain and phase), and since the combining is done digitally, each receive channel can be corrected prior to combining. This enables an unprecedented level of accuracy and control through onboard processing. SweepSAR promises significant increases in instrument capability for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined onboard, in real time. New methods are being developed for digitally calibrating digital beam-forming arrays to reduce development time, risk, and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop digital calibration, thus tracking systematic changes regardless of temperature.-

Hoffman, James P.↗

Improving metastable impact electron spectroscopy and ultraviolet photoelectron spectroscopy signals by means of a modified time-of-flight separation

The separation of ultraviolet photoelectron spectroscopy (UPS) and metastable impact electron spectroscopy (MIES) is usually performed by a time-of-flight (ToF) separation using pre-set ToF for both types of signal. In this work, we present a new, improved ex situ signal separation method for the separation of MIES and UPS for every single measurement. Signal separation issues due to changes of system parameters can be overcome by changing the ToF separation and therefore allowing for the application of a wider range of measuring conditions. The method also enables to identify and achieve separation of the two signals without any time consuming calibration and the use of any special material for the calibration. Furthermore, changes made to the discharge source are described that enable to operate an existing MIES/UPS source over a broader range of conditions. This allows for tuning of the yield of UV photons and metastable rare gas atoms leading to an improved signal to noise ratio. First results of this improved setup are well in agreement with spectra reported in literature and show increased resolution and higher signal intensities for both MIE and UP spectra compared to the previous, non-optimized setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the photon spectrometer PHOS of the ALICE experiment

The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at √s = 13 TeV. After applying all corrections, the achieved mass resolutions for π 0 and η mesons for p T > 1.7 GeV/c are σ m π0 = 4.56 ± 0.03 MeV/c 2 and σ m η = 15.3 ± 1.0 MeV/c 2 , respectively.

47 OTHER INSTRUMENTATION↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

System concepts for transmit arrays of parabolic antennas for deep space uplinks

Phased arrays of parabolic antennas are a potentially lower-cost way to provide uplink transmission to distant spacecraft, compared to the 34-m and 70-m antennas now used by the NASA Deep Space Network. A large transmit array could provide very high EIRP when needed for spacecraft emergencies, such as the equivalent of 1 MW radiated from a 70-m antenna. Cost-effectiveness is realized by dividing the array into smaller arrays to provide routine support to many spacecraft simultaneously. The antennas might be as small as 12-m in diameter, with as many as 100 antennas covering an area of 0.5 km to 1 km in extent. Such arrays present significant technical challenges in phase alignment, which must be maintained at close to 1 mm. The concept requires a very stable system with accurately known antenna phase center locations. The system is first calibrated by transmitting from all antennas, and observing the signals at a target located in the far fields of the individual antennas. The antennas are then pointed to the operational targets, with the signal phases and time delays set to reinforce in the target directions. This requires accurate knowledge of the target directions and calculation of the required phases. The system must be phase-stable for all directions and over the time between calibrations, which is desired to be at least one day. In this paper, a system concept is presented, the major error sources are identified, a rough error budget is established, and key elements of the system are discussed. A calibration method is recommended which uses satellites as radar targets. The performance goal is to achieve a combining loss of less than 0.2 dB in good weather, and of less than 1 dB in all but extremely bad weather.

Effective Isotropic Radiated Power (EIRP)↗

A Long-Term Merged Global Ozone Data Set

Using data from a series of space-based ozone measurement systems we are producing a consistent, calibrated ozone time series that can be used for trend analyses and other studies. To produce the total column ozone time series we use data from Total Ozone Mapping Spectrometer (TOMS) instruments on Nimbus 7 and Earth Probe, and data from the Ozone Monitoring Instrument (OMI) flying on the Aura spacecraft. Both total column ozone and the ozone vertical profile data are produced from the Solar Backscatter Ultraviolet (SBUV) instruments on Nimbus 7 and SBUV/2 instruments on a series of NOAA spacecraft. A global zonal mean merged ozone data time series covering the period from 1970-1972 and 1978-2010 has been produced for total column ozone. A similar profile data set has been constructed, but is still in preliminary form due to uncertainty in calibration adjustments as a function of latitude and altitude.

McPeters, Richard D.↗

The Version 8.6 SBUV Ozone Data Record: An Overview

Under a NASA program to produce long-term data records from instruments on multiple satellites, data from a series of nine Solar Backscatter Ultraviolet (SBUV and SBUV2) instruments have been re-processed to create a coherent ozone time series. Data from the BUV instrument on Nimbus 4, SBUV on Nimbus 7, and SBUV2 instruments on NOAA 9, 11, 14, 16, 17, 18, and 19 covering the period 1970-1972 and 1979-2011 were used to create a long-term data set. The goal is an ozone Earth Science Data Record - a consistent, calibrated ozone time series that can be used for trend analyses and other studies. In order to create this ozone data set, the radiances were adjusted and used to re-process the entire data records for each of the nine instruments. Inter-instrument comparisons during periods of overlap as well as comparisons with data from other satellite and ground-based instruments were used to evaluate the consistency of the record and make calibration adjustments as needed. Additional improvements in this version 8.6 processing included the use of the Brion, Daumont, and Malicet ozone cross sections, and a cloud-height climatology derived from Aura OMI measurements. Validation of the re-processed ozone shows that total column ozone is consistent with the Brewer Dobson network to within about 1 for the new time series. Comparisons with MLS, SAGE, sondes, and lidar show that ozone at individual levels in the stratosphere is generally consistent to within 5 percent.

ozone↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the BaBar CsI(Tl) Calorimeter

After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗