Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

IR Spot Weld Inspect

In automotive industry, destructive inspection of spot welds is still the mandatory quality assurance method due to the lack of efficient non-destructive evaluation (NDE) tools. However, it is costly and time-consuming. Recently at ORNL, a new NDE prototype system for spot weld inspection using infrared (IR) thermography has been developed to address this problem. This software contains all the key functions that ensure the NDE system to work properly: system input/output control, image acquisition, data analysis, weld quality database generation and weld quality prediction, etc.

Chen, Jian↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples of imaging issues and recommended solutions will be discussed. TG-142 Imaging QA Simplified: Lessons From Diagnostic Physics Collaboration There are many commercial options for the performance of imaging quality assurance tests for the linear accelerator imaging systems as required by the AAPM TG-142 report. Imaging quality assurance testing is largely performed by the diagnostic physicist so routine performance of these tests by the practicing oncology physicist can be complicated and confusing given all of the commercially available options. This presentation focuses on the performance of imaging quality assurance testing for linear accelerators using methods similar to that of diagnostic physicists. This presentation will address the ability to perform the required testing without complicated software and explores solutions for the performance of these tests in an efficient manner while still maintaining the ability to ascertain image quality changes that may ultimately affect clinical decisions.

60 APPLIED LIFE SCIENCES↗

Involvement of LPA signaling via LPA receptor-2 in the promotion of malignant properties in osteosarcoma cells

Highlights: • LPA receptor expressions were changed by the long-term CDDP treatment in MG-63 cells. • The cell motile and invasive activities of MG-63 cells were stimulated by the long-term CDDP treatment. • LPAR2 expression was markedly elevated in highly migratory MG-63 cells. • Cellular functions induced by CDDP were suppressed by LPA{sub 2} knockdown. • LPA{sub 2} plays an important role in the acquisition of malignant properties during tumor progression in MG-63 cells. Lysophosphatidic acid (LPA) signaling via G protein-coupled LPA receptors mediates various biological effects in cancer cells. This study aimed to investigate the roles of LPA receptors in the regulation of cellular functions during tumor progression in osteosarcoma cells. Long-term cisplatin (CDDP)-treated MG63-C and MG63-R7-C cells were generated from osteosarcoma MG-63 and highly-migratory MG63-R7 cells, respectively. LPAR2 and LPAR3 expression levels were significantly higher in MG63-C cells than in MG-63 cells, while LPAR1 expression was reduced. MG63-C cells were highly motile, compared with MG-63 cells. MG63-C cell motility was suppressed by LPA{sub 2} knockdown and enhanced by the LPA{sub 1}/LPA{sub 3} antagonist, dioctanoylglycerol pyrophosphate. LPAR2 and LPAR3 expression levels were significantly elevated in MG63-R7-C cells in comparison with MG63-R7 cells. MG63-R7-C cells were found to be highly invasive, correlating with metalloproteinase-2 activation. MG63-R7-C cells formed large colonies, whereas colony formation was absent from MG63-R7 cells. Notably, MG63-R7-C cell activities were inhibited by LPA{sub 2} knockdown. These results suggest that LPA signaling via LPA{sub 2} plays an important role in the acquisition of malignant properties during tumor progression in MG-63 cells.

60 APPLIED LIFE SCIENCES↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

Characterization of Silicon Sensors for HGCal in CMS

The High-granularity Calorimeter silicon sensors suffer from leakage currents. Measurements of the leakage current as a function of temperature and reverse bias voltage were carried out using a temperature chamber and digital source-meter. In addition to analysis of the sensors, a redesigned data acquisition software was written and utilized to simplify the setup. It was determined that the sensors do follow expected behavior for the leakage current as a function of both reverse bias voltage and temperature, but there is some slight deviation at lower temperatures.

43 PARTICLE ACCELERATORS↗

Global Proteomics Reveal An Atypical Strategy for Carbon/Nitrogen Assimilation by a Cyanobacterium Under Diverse Environmental Perturbations

Cyanobacteria, the only prokaryotes capable of oxygenic photosynthesis, are present in diverse ecological niches and play crucial roles in global carbon and nitrogen cycles. To proliferate in nature, cyanobacteria utilize a host of stress responses to accommodate periodic changes in environmental conditions. A detailed knowledge of the composition of, as well as the dynamic changes in, the proteome is necessary to gain fundamental insights into such stress responses. Toward this goal, we have performed a largescale proteomic analysis of the widely studied model cyanobacterium Synechocystis sp. PCC 6803 under 33 different environmental conditions. The resulting high-quality dataset consists of 22,318 unique peptides corresponding to 1,955 proteins, a coverage of 53% of the predicted proteome. Quantitative determination of protein abundances has led to the identification of 1,198 differentially regulated proteins. Notably, our analysis revealed that a common stress response under various environmental perturbations, irrespective of amplitude and duration, is the activation of atypical pathways for the acquisition of carbon and nitrogen from urea and arginine. In particular, arginine is catabolized via putrescine to produce succinate and glutamate, sources of carbon and nitrogen, respectively. This study provides the most comprehensive functional and quantitative analysis of the Synechocystis proteome to date, and shows that a significant stress response of cyanobacteria involves an uncommon mode of acquisition of carbon and nitrogen. Oxygenic phototrophic prokaryotes, the progenitors of the chloroplast, are crucial to global oxygen production and worldwide carbon and nitrogen cycles. These microalgae are robust organisms capable carbon neutral biofuel production. Synechocystis sp. PCC 6803 has historically been a model cyanobacterium for photosynthetic research and is emerging as a promising biofuel platform. Cellular responses are severely modified by environmental conditions, such as temperature and nutrient availability. However the global protein responses of Synechocystis 6803 under physiological relevant environmental stresses have not been characterized. Here we present the first global proteome analysis of a photoautotrophic bacteria and the most complete coverage to date of a photosynthetic prokaryotic proteome. To obtain a more complete description of the protein components of Synechocystis 6803, we have performed an in-depth proteome analysis of this organism utilizing the Accurate Mass and Time (AMT) tag approach1 utilizing 33 growth conditions and timepoints. The resulting proteome consists of 22,318 unique peptides, corresponding to 2,369 unique proteins, covering 65% of the predicted proteins. Quantitative analysis of protein abundance ratios under nutrient stress revealed that Synechocystis 6803 resorts to a universal mechanism for nitrogen utilization under phosphate, sulfate, iron, and nitrogen depletion. Comparison of this proteomic data with previously published microarray studies under similar environmental conditions showed that the general response predicted by both types of analyses are common but that the actual levels of protein expression can not be inferred from gene expression data. Our results demonstrate a global nitrogen response to multiple stressors that may be similar to that used by other cyanobacteria under various stress conditions. We anticipate that this protein expression data will be a foundation for the photosynthetic and biofuel communities to better understand metabolic changes under physiological conditions relevant to global productivity. Further more, this comparison of correlation between gene and protein expression data provides deeper insight into the ongoing debate as to whether gene expression can be used to infer cellular response.

54 ENVIRONMENTAL SCIENCES↗

Structural basis of PP2A activation by PTPA, an ATP-dependent activation chaperone

Proper activation of protein phosphatase 2A (PP2A) catalytic subunit is central for the complex PP2A regulation and is crucial for broad aspects of cellular function. The crystal structure of PP2A bound to PP2A phosphatase activator (PTPA) and ATPγS reveals that PTPA makes broad contacts with the structural elements surrounding the PP2A active site and the adenine moiety of ATP. PTPA-binding stabilizes the protein fold of apo-PP2A required for activation, and orients ATP phosphoryl groups to bind directly to the PP2A active site. This allows ATP to modulate the metal-binding preferences of the PP2A active site and utilize the PP2A active site for ATP hydrolysis. In vitro, ATP selectively and drastically enhances binding of endogenous catalytic metal ions, which requires ATP hydrolysis and is crucial for acquisition of pSer/Thr-specific phosphatase activity. Furthermore, both PP2A- and ATP-binding are required for PTPA function in cell proliferation and survival. Our results suggest novel mechanisms of PTPA in PP2A activation with structural economy and a unique ATP-binding pocket that could potentially serve as a specific therapeutic target.

59 BASIC BIOLOGICAL SCIENCES↗

Predicting Pulsed-Laser Deposition SrTiO 3 Homoepitaxy Growth Dynamics Using High-Speed Reflection High-Energy Electron Diffraction

Pulsed-laser deposition (PLD) is a powerful technique for growing complex oxides with controlled stoichiometry. To understand growth dynamics therein, it is common to leverage in situ spectroscopies, such as reflection high-energy electron diffraction (RHEED), to monitor surface crystallinity. Most commercial systems rely on video-rate cameras operating at 60-120 Hz that lack sufficient temporal resolution to capture growth dynamics at practical deposition frequencies. Here, a high-speed platform to record in situ dynamics via RHEED at >500 Hz is implemented. An open-source analysis package is designed to fit diffraction spots to 2D Gaussians, allowing single-pulse surface reconstruction kinetics extraction. Using homoepitaxially deposited (001)-oriented SrTiO 3 as a model system, we demonstrate how high-speed RHEED can provide real-time insight into growth processes obscured by slower acquisition systems. By fitting the single-pulse intensity to a set of exponential functions, we observe changes in the characteristic decay time and mechanism correlated to the substrate step width and surface termination. We observe distinct surface effects, with diffraction intensity decaying on lower-energy TiO 2 -terminated surfaces and stabilizing on SrO- or mixed-terminated surfaces. Similarly, using an exponential model, the extracted characteristic time of adatom deposition decreases with increased density of bonding sites associated with mixed termination and narrower step widths. Ultimately, this work shows how increasing RHEED temporal resolution can uncover new insights into growth processes, with practical implications for the design and control of PLD processes. This experimental platform provides new capabilities to enable data-driven machine learning analysis and autonomous control systems to enhance the complexity and fecundity of PLD.

(SrO)↗

Molecular basis of hemoglobin binding and heme removal in Corynebacterium diphtheriae

To successfully mount infections, nearly all bacterial pathogens must acquire iron, a key metal cofactor that primarily resides within human hemoglobin. Corynebacterium diphtheriae causes the life-threatening respiratory disease diphtheria and captures hemoglobin for iron scavenging using the surface-displayed receptor HbpA. Here, we show using X-ray crystallography, NMR, and in situ binding measurements that C. diphtheriae selectively captures iron-loaded hemoglobin by partially ensconcing the heme molecules of its α subunits. Quantitative growth and heme release measurements are compatible with C. diphtheriae acquiring heme passively released from hemoglobin’s β subunits. We propose a model in which HbpA and heme-binding receptors collectively function on the C. diphtheriae surface to capture hemoglobin and its spontaneously released heme. Acquisition mechanisms that exploit the propensity of hemoglobin’s β subunit to release heme likely represent a common strategy used by bacterial pathogens to obtain iron during infections.

NMR↗

TH-A-18C-11: An Investigation of KV CBCT Image Quality and Dose Reduction for Volume-Of-Interest Imaging Using Dynamic Collimation

Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kV-CBCT using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of one-dimensional translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian OBI system. CBCT and planar image quality was investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various anatomical sites were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 cm to 2.4 cm (at isocenter). Similarly, this change in iris diameter corresponds to a factor increase of approximately 1.4 and 1.5 in image contrast for CBCT and planar images, respectively, and similarly a factor decrease in image noise of approximately 1.7 and 1.5. This results in a measured gain in contrast-to-noise ratio of a factor of approximately 2.3 for both CBCT and planar images. Depending upon the anatomical site, dose was reduced to 10%–70% of the full field value along the central axis plane and down to 2% along the axial planes, while maintaining the same dose to the VOI compared to full-field techniques. Conclusion: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

60 APPLIED LIFE SCIENCES↗

Creation of System Validation Platform

The objective of this CRADA between Sandia National Laboratories (SNL) and SunSpec Alliance (SunSpec) was to create a software test platform called the System Validation Platform (SVP) that performs end-to-end certification testing of photovoltaic (PV) inverters, energy storage systems, and other distributed energy resources (DERs). The SVP automates interactions of test equipment (PV and grid simulators), data acquisition systems, and interoperable DERs to certify the devices for advanced grid-support functions and interoperability. To assist electricity grid, operators maintain voltage and frequency, new interconnection requirements in the U.S. and Europe require DERs to have grid-support functions with adjustable settings. Automating the certification process for DER devices impacts the bottom line of NRTLs because they do not need to rely on test engineers running days (or weeks) of experiments to validate the performance of the equipment. These savings can then be passed down to the DER vendors so the certification process becomes less expensive and lowers the barrier to market for PV inverters, charge controllers, and other grid-interconnected equipment. This technology can also be used as a research platform for SNL, other national labs, and universities that would like to run hardware tests with power electronics equipment.

14 SOLAR ENERGY↗

Upgrade of the Graphical User Interface (GUI) of otsdaq

otsdaq is a data acquisition software. The purpose of this project was to improve the design and the functionality of some features on the Graphical User Interface of otsdaq. The GUI interface is developed in HTML and JavaScript. The code is maintained on GitHub and developed by different users working on a remote machine environment.

Najjuma, Brenda↗

Status of ICARUS NUMI Interaction Cross-Section Analysis

The ICARUS experiment, utilizing Liquid Argon Time Projection Chamber (LAr TPC) technology, has been installed at Fermilab in Chicago, Illinois, following its initial operation in Italy and subsequent refurbishment at CERN. ICARUS completed commissioning in June 2022. Currently, the experiment is in the phase of analyzing data from its two runs of physics data acquisition and gearing up for the third run. While its primary objective is to function as the far detector of the Short Baseline Neutrino program (SBN), seeking sterile neutrino signatures, ICARUS also offers diverse physics capabilities, including searches beyond the standard model and measurements of cross-sections. In addition to being exposed to the common Booster Neutrino (BNB) beamline, ICARUS also receives off-axis neutrinos from the Main Injector (NuMI) beam. Due to the off-axis angle between NuMI and ICARUS, coupled with contributions from both pion and kaon decays to neutrino fluxes, interactions of NuMI neutrinos within ICARUS can be detected over a range of several GeV in energy. These interactions present opportunities for crucial cross-section measurements and model tests within an energy range that overlaps both the SBN oscillation search and a portion of the DUNE spectrum. This poster presentation will delve into our efforts to conduct a muon-neutrino cross-section measurement, where the signal is defined by events with no pions produced in the final state of the interaction, along with some preliminary muon-neutrino inclusive measurements. Additionally, it will provide updates on the current status and future plans, including reconstruction, selection, and analysis procedures.

43 PARTICLE ACCELERATORS↗

Lifecycle Management of Nuclear Security Radiation Detection Systems: Testing and Evaluation

The lifecycle of radiation detection systems functioning within a State’s Nuclear Security Detection Architecture encompasses all activities associated with acquisition, deployment, and eventual disposal. Throughout a system’s lifecycle, testing and evaluation activities are needed to ensure requirements are continually met, as underscored by recent experiences.This paper provides:1.A discussion of reasons why testing should be part of the radiation detection equipment lifecycle before, during, and after acquisition.2.A general process for determining applicable evaluation methods.3.A discussion of issues related to integrating testing and evaluation into procurement and operational processes and mitigation strategies.

Harris, Tyrone↗

An open science resource for establishing reliability and reproducibility in functional connectomics

Efforts to identify meaningful functional imaging-based biomarkers are limited by the ability to reliably characterize inter-individual differences in human brain function. Although a growing number of connectomics-based measures are reported to have moderate to high test-retest reliability, the variability in data acquisition, experimental designs, and analytic methods precludes the ability to generalize results. The Consortium for Reliability and Reproducibility (CoRR) is working to address this challenge and establish test-retest reliability as a minimum standard for methods development in functional connectomics. Specifically, CoRR has aggregated 1,629 typical individuals’ resting state fMRI (rfMRI) data (5,093 rfMRI scans) from 18 international sites, and is openly sharing them via the International Data-sharing Neuroimaging Initiative (INDI). To allow researchers to generate various estimates of reliability and reproducibility, a variety of data acquisition procedures and experimental designs are included. Similarly, to enable users to assess the impact of commonly encountered artifacts (for example, motion) on characterizations of inter-individual variation, datasets of varying quality are included.

60 APPLIED LIFE SCIENCES↗