Search NASA⌕ Search

SEARCH · Search NASA

Results for “allan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Sublimation: A Mechanism for the Enrichment of Organics in Antarctic Ice

Recent analyses of the carbonate globules present in the Martian meteorite ALH84001 have detected polycyclic aromatic hydrocarbons (PAHs) at the ppm level. The distribution of PAHs observed in ALH84001 was interpreted as being inconsistent with a terrestrial origin and were claimed to be indigenous to the meteorite, perhaps derived from an ancient Martian biota. However, Becker et al., have examined PAHs in the Martian meteorite EETA79001, in several Antarctic carbonaceous chondrites and Antarctic Allan Hills Ice and detected many of the same PAHs found in ALH84001. The reported presence of L-amino acids of apparent terrestrial origin in the EETA79001 druse material, suggests that this meteorite is contaminated with terrestrial/extraterrestrial organics probably derived from Antarctic ice meltwater that had percolated through the meteorite. The detection of PAHs and L-amino acids in these Martian meteorites suggests that despite storage in the Antarctic ice, selective changes of certain chemical and mineralogical phases has occurred.

Becker, Luann↗

Media Calibration in the Deep Space Network: A Status Report

A new media calibration system (MCS) has been implemented at the Goldstone complex of the DSN (Deep Space Network). It is intended to calibrate the delay of radio signals imposed by the neutral atmosphere. The system provides periodic measurements of both the static dry and fluctuating wet components of this delay. In particular, the system will calibrate the fluctuations in line of sight path delay due to atmospheric water vapor that we believe will dominate the error budget for several radio science and radio astronomy experiments. We have compared two of these media calibration systems with a connected element interferometer on a 21 km baseline. In this report we describe a total of 30 observations in which a radio source was tracked for an hour or more and the delay residuals then calibrated using the MCS. The accuracy of the comparison appears to be limited by systematic errors in the interferometer, which are under investigation. However, our results do indicate that the MCS can meet or exceed the two-way Allan standard deviation specification of 1.5 x 10( exp -15) on time scales of 2,000 - 10,000 sec, as required by the Cassini GWE (Gravitational Wave Experiment) for two way Doppler tracking.

Naudet, Charles J.↗

Compositions of Partly Altered Olivine and Replacement Serpentine in the CM2 Chondrites QUE93005 and Nogoya: Implications for Scales of Elemental Redistribution During Aqueous Alteration

Some phyllosilicates in CM carbonaceous chondrites formed by aqueous alteration of anhydrous precursor phases. Although broad trends in the compositions of hydrous phyllosilicates are recognized and believed to be related to trends in degree of aqueous alteration, details of the reactions that formed specific secondary minerals remain obscure. This paper reports compositional relationships between remnants of partially pseudomorphically replaced silicates and their alteration products (serpentine) in the CM2 chondrites QUE93005 and Nogoya and compares both with previously published results for Allan Hills 81002. By focusing on serpentine formed from known reactants (olivines), and on only those instances in which some of the reactant silicate remains, direct compositional relationships between reactants and products, and the elemental mobility required by the reactions, can be established.

Velbel, M. A.↗

Deviations from uniform power law scaling in nonstationary time series

A classic problem in physics is the analysis of highly nonstationary time series that typically exhibit long-range correlations. Here we test the hypothesis that the scaling properties of the dynamics of healthy physiological systems are more stable than those of pathological systems by studying beat-to-beat fluctuations in the human heart rate. We develop techniques based on the Fano factor and Allan factor functions, as well as on detrended fluctuation analysis, for quantifying deviations from uniform power-law scaling in nonstationary time series. By analyzing extremely long data sets of up to N = 10(5) beats for 11 healthy subjects, we find that the fluctuations in the heart rate scale approximately uniformly over several temporal orders of magnitude. By contrast, we find that in data sets of comparable length for 14 subjects with heart disease, the fluctuations grow erratically, indicating a loss of scaling stability.

Non-NASA Center↗

A search for endogenous amino acids in martian meteorite ALH84001

Trace amounts of glycine, serine, and alanine were detected in the carbonate component of the martian meteorite ALH84001 by high-performance liquid chromatography. The detected amino acids were not uniformly distributed in the carbonate component and ranged in concentration from 0.1 to 7 parts per million. Although the detected alanine consists primarily of the L enantiomer, low concentrations (<0.1 parts per million) of endogenous D-alanine may be present in the ALH84001 carbonates. The amino acids present in this sample of ALH84001 appear to be terrestrial in origin and similar to those in Allan Hills ice, although the possibility cannot be ruled out that minute amounts of some amino acids such as D-alanine are preserved in the meteorite.

NASA Discipline Exobiology↗

Record of fluid-rock interactions on Mars from the meteorite ALH84001

Allan Hills (ALH) 84001 is the most recently recognized member of a suite of meteorites--the SNCs--that almost certainly originated on Mars. Several factors distinguish ALH84001 from the other SNC meteorites. Preliminary studies suggest that it may be older than other martian meteorites. Moreover, it contains abundant, zoned domains of calcium-iron-magnesium carbonate that are indigenous to the sample and thus may hold important clues regarding near-surface processes on Mars and the evolution of the martian atmosphere. We report here analyses of the carbon and oxygen stable-isotope compositions of the carbonates that place constraints on their formation conditions. Our results imply the presence of at least two chemically distinct carbonates--one Ca,Fe-rich, the other Mg-rich--that are enriched in 13C relative to terrestrial carbonates (delta 13C approximately +41/1000), consistent with martian atmospheric CO2 as the carbon source. The oxygen isotope compositions of the carbonates indicate that they precipitated from a low-temperature fluid in the martian crust. Combined with textural and bulk geochemical considerations, the isotope data suggest that carbonate deposition took place in an open-system environment in which the ambient temperature fluctuated.

Carbonates/analysis↗

Precise Clock Solutions Using Carrier Phase from GPS Receivers in the International GPS Service

As one of its activities as an Analysis Center in the International GPS Service (IGS), the Jet Propulsion Laboratory (JPL) uses data from a globally distributed network of geodetic-quality GPS receivers to estimate precise clock solutions, relative to a chosen reference, for both the GPS satellites and GPS receiver internal clocks, every day. The GPS constellation and ground network provide geometrical strength resulting in formal errors of about 100 p sec for these estimates. Some of the receivers in the global IGS network contain high quality frequency references, such as hydrogen masers. The clock solutions for such receivers are smooth at the 20-p sec level on time scales of a few minutes. There are occasional (daily to weekly) shifts at the microsec level, symptomatic of receiver resets, and 200-p sec-level discontinuities at midnight due to 1-day processing boundaries. Relative clock solutions among 22 IGS sites proposed as "fiducial" in the IGS/BIPM pilot project have been examined over a recent 4-week period. This allows a quantitative measure of receiver reset frequency as a function of site. For days and-sites without resets, the Allan deviation of the relative clock solutions is also computed for subdaily values of tau..

Zumberge, J. F.↗

Autonomy Software Architecture for LORAX (Life On ice Robotic Antarctic eXplorer)

LORAX is a robotic astrobiological study of the ice field surrounding the Carapace Nunatak near the Allan Hills in Antarctica. The study culminates in a l00km traverse, sampling the ice at various depths (from surface to 10cm) at over 100 sites to survey microbial ecology and to record environmental parameters. The autonomy requirements from LORAX are shared by many robotic exploration tasks. Consequently, the LORAX autonomy architecture is a general architecture for on-board planning and execution in environments where science return is to be maximized against resource limitations and other constraints.

Jonsson, Ari↗

FFT-based methods for simulating flicker FM

Four algorithms for simulating flicker FM phase noise are given, two old and two new. Their Allan deviation and mean square time interval error (MSTIE) are examined.

flicker noise simulation phase noise↗

Improved Performance of a Temperature Compensated LN2 Cooled Sapphire Oscillator

We report on improved stability in a whispering gallery sapphire resonator for which the dominant WGHn11 microwave mode family shows frequency-stable, compensated operation for temperatures above 77K. Several modifications during the past year have led to significant improvements in performance. Current tests with improved thermal stability provide Allan Deviation of frequency of 2.6 - 4 ? 10-13 for measurement times of 1#t#100 seconds. We project a frequency stability of 1014 for this resonator with stabilized housing temperature and with a mode Q of 107.!.

Temperature Compensated LN2 Cooled Sapphire Oscill↗

Evaluation of Meterorite Amono Acid Analysis Data Using Multivariate Techniques

The amino acid distributions in the Murchison carbonaceous chondrite, Mars meteorite ALH84001, and ice from the Allan Hills region of Antarctica are shown, using a multivariate technique known as Principal Component Analysis (PCA), to be statistically distinct from the average amino acid compostion of 101 terrestrial protein superfamilies.

meteorites Amino acids Multivariate Analysis↗

A multichannel dual-mixer stability analyzer: progress report

A stability analyzer is being developed for frequency standards in JPL's Deep Space Network. Prototype hardware and software have been built. Initial tests on 100-MHz sources show an Allan deviation noise floor of about 7 X 10(sup -15) at 1 second for a dual-mixer channel.

frequency time stability dual mixer↗

A high performance frequency standard and distribution system for Cassini Ka-band experiment

This paper provides an overview and update of a specialized frequency reference system for the NASA Deep Space Network (DSN) to support Ka-band radio science experiments with the Cassini spacecraft, currently orbiting Saturn. Three major components, a Hydrogen Maser, Stabilized Fiber-optic Distribution Assembly (SFODA), and 10 Kelvin Cryocooled Sapphire Oscillator (10K CSO) and frequency-lock-loop, are integrated to achieve the very high performance, ground based frequency reference at a remote antenna site located 16 km from the hydrogen maser. Typical measured Allan Deviation is 1.6 -14 1 0a't 1 second and 1.7 x 10 -15 at 1000 seconds averaging intervals. Recently two 10K CSOs have been compared in situ while operating at the remote DSN site DSS-25. The CSO references were used operationally to downconvert the Ka band downlink received from the Cassini spacecraft in a series of occultation measurements performed over a 78 day period from March to June 2005.

sapphire↗

Performance of the PARCS Testbed Cesium Fountain Frequency Standard

A cesium fountain frequency standard has been developed as a ground testbed for the PARCS (Primary Atomic Reference Clock in Space) experiment, an experiment intended to fly on the International Space Station. We report on the performance of the fountain and describe some of the implementations motivated in large part by flight considerations, but of relevance for ground fountains. In particular, we report on a new technique for delivering cooling and trapping laser beams to the atom collection region, in which a given beam is recirculated three times effectively providing much more optical power than traditional configurations. Allan deviations down to 10 have been achieved with this method.

cesium↗

LU-HF Age and Isotope Systematics of ALH84001

Allan Hills (ALH) 84001 is an orthopyroxenite that is unique among the Martian meteorites in having the oldest inferred crystallization age (approx..4.5 to 4.0 Gyr) [e.g., 1-6 and references therein 7]. Its ancient origin makes this stone a critical constraint on early history of Mars, in particular the evolution of different planetary crust and mantle reservoirs. However, because there is significant variability in reported crystallization ages, determination of initial isotope compositions is imprecise making assessment of planetary reservoirs difficult. Here we report a new Lu-Hf mineral isochron age, initial Hf-176/Hf-177 isotope composition, and inferred Martian mantle source compositions for ALH84001 that place constraints on longlived source reservoirs for the enriched shergottite suite of Martian meteorites including Shergotty, Zagami, NWA4468, NWA856, RBT04262, LAR06319, and Los Angeles. Sm-Nd isotope analyses are under way for the same mineral aliquots analyzed for Lu-Hf. The Lu-Hf system was utilized because Lu and Hf are both lithophile and refractory and are not easily redistributed during short-lived thermal pulses associated with shock metamorphism. Moreover, chromite has relatively modest Hf concentrations with very low Lu/Hf ratios [9] yielding tight constraints on initial Hf-176/Hf-177 isotope compositions

Righter, M.↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Performance of Planar-Waveguide External Cavity Laser for Precision Measurements

A 1542-nm planar-waveguide external cavity laser (PW-ECL) is shown to have a sufficiently low level of frequency and intensity noise to be suitable for precision measurement applications. The frequency noise and intensity noise of the PW-ECL was comparable or better than the nonplanar ring oscillator (NPRO) and fiber laser between 0.1 mHz to 100 kHz. Controllability of the PW-ECL was demonstrated by stabilizing its frequency to acetylene (13C2H2) at 10(exp -13) level of Allan deviation. The PW-ECL also has the advantage of the compactness of a standard butterfly package, low cost, and a simple design consisting of a semiconductor gain media coupled to a planar-waveguide Bragg reflector. These features would make the PW-ECL suitable for precision measurements, including compact optical frequency standards, space lidar, and space interferometry

Numata, Kenji↗