Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

202 records · Page 12

Dielectric properties of neutron and proton irradiated polymeric nanocomposite insulation for superconducting magnets of fusion power plants

Studies on radiation-resistant electrical insulation for superconducting magnets of nuclear fusion power plants are discussed. Metal oxide nanoparticle-incorporated organic polymer composite (MONAP) insulation films were manufactured and studied for their dielectric breakdown strength after exposure to neutrons and proton radiation at varying levels. Samples with up to 5 wt% of nanoparticles (NPs) of SiO 2 , MgO, and ZrO 2 were studied. The samples were exposed to radiation of up to 2 × 10 16 neutrons/cm 2 and 200 Mrad of protons. The addition of the nanoparticles improved the radiation resistance of the MONAP, and the performance depended on the type of NPs and the radiation exposure. Dielectric breakdown measurements at 77 K showed little degradation. Enhancement of dielectric strength was observed in some instances.

36 MATERIALS SCIENCE↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗