Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Phase Sensitive X-Ray Diffraction Imaging of Defects in Biological Macromolecular Crystals

Characterization of defects and/or disorder in biological macromolecular crystals presents much greater challenges than in conventional small-molecule crystals. The lack of sufficient contrast of defects is often a limiting factor in x-ray diffraction topography of protein crystals. This has seriously hampered efforts to understand mechanisms and origins of formation of imperfections, and the role of defects as essential entities in the bulk of macromolecular crystals. In this report, we employ a phase sensitive x-ray diffraction imaging approach for augmenting the contrast of defects in protein crystals.

Hu, Z. W.↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Origins of ferromagnetism in transition-metal doped Si

We present results of the magnetic, structural, and chemical characterizations of Mn{sup +}-implanted Si displaying n-type semiconducting behavior and ferromagnetic ordering with Curie temperature, T{sub C}, well above room temperature. The temperature-dependent magnetization measured by superconducting quantum interference device from 5 to 800 K was characterized by three different critical temperatures (T{sub C}*{approx}45 K, T{sub C1}{approx}630-650 K, and T{sub C2}{approx}805-825 K). Their origins were investigated using dynamic secondary ion mass spectroscopy and transmission electron microscopy (TEM) techniques, including electron energy loss spectroscopy, Z-contrast scanning TEM imaging, and electron diffraction. We provided direct evidences of the presence of a small amount of Fe and Cr impurities which were unintentionally doped into the samples together with the Mn{sup +} ions as well as the formation of Mn-rich precipitates embedded in a Mn-poor matrix. The observed T{sub C}* is attributed to the Mn{sub 4}Si{sub 7} precipitates identified by electron diffraction. Possible origins of T{sub C1} and T{sub C2} are also discussed. Our findings raise questions regarding the origin of the high-T{sub C} ferromagnetism reported in many material systems without a careful chemical analysis.

36 MATERIALS SCIENCE↗

Origin of enhanced magnetization in rare earth doped multiferroic bismuth ferrite

We report structural and magnetic properties of rare earth doped Bi{sub 0.95}R{sub 0.05} FeO{sub 3} (R = Y, Ho, and Er) submicron particles. Rare earth doping enhances the magnetization and the magnetization shows an increasing trend with decreasing dopant ionic radii. In contrast to the x-ray diffraction pattern, we have seen a strong evidence for the presence of rare earth iron garnets R{sub 3}Fe{sub 5}O{sub 12} in magnetization measured as a function of temperature, in selected area electron diffraction, and in Raman measurements. Our results emphasised the role of secondary phases in the magnetic property of rare earth doped BiFeO{sub 3} compounds along with the structural distortion favoring spin canting by increase in Dzyaloshinskii-Moriya exchange energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of the rare-earth element on the effects of the structural and magnetic phase transitions in CeFeAsO, PrFeAsO, and NdFeAsO

We present results of transport and magnetic properties and heat capacity measurements on polycrystalline CeFeAsO, PrFeAsO and NdFeAsO. These materials undergo structural phase transitions, spin density wave-like magnetic ordering of small moments on iron and antiferromagnetic ordering of rare-earth moments. The temperature dependence of the electrical resistivity, Seebeck coefficient, thermal conductivity, Hall coefficient and magnetoresistance are reported. The magnetic behavior of the materials have been investigated using Moessbauer spectroscopy and magnetization measurements. Transport and magnetic properties are affected strongly by the structural and magnetic transitions, suggesting significant changes in the band structure and/or carrier mobilities occur, and phonon-phonon scattering is reduced upon transformation to the low-temperature structure. Results are compared with recent reports for LaFeAsO, and systematic variations in properties as the identity of Ln is changed are observed and discussed. As Ln progresses across the rare-earth series from La to Nd, an increase in the hole contributions to the Seebeck coefficient and increases in magnetoresistance and the Hall coefficient are observed in the low-temperature phase. Analysis of hyperfine fields at the iron nuclei determined from Moessbauer spectra indicates that the moment on Fe in the orthorhombic phase is nearly independent of the identity of Ln, in apparent contrast to reports of powder neutron diffraction refinements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments

Hardware and software solutions for MX data-collection strategies using the EMBL/ESRF miniaturized multi-axis goniometer head are presented. Most macromolecular crystallography (MX) diffraction experiments at synchrotrons use a single-axis goniometer. This markedly contrasts with small-molecule crystallography, in which the majority of the diffraction data are collected using multi-axis goniometers. A novel miniaturized κ-goniometer head, the MK3, has been developed to allow macromolecular crystals to be aligned. It is available on the majority of the structural biology beamlines at the ESRF, as well as elsewhere. In addition, the Strategy for the Alignment of Crystals (STAC) software package has been developed to facilitate the use of the MK3 and other similar devices. Use of the MK3 and STAC is streamlined by their incorporation into online analysis tools such as EDNA. The current use of STAC and MK3 on the MX beamlines at the ESRF is discussed. It is shown that the alignment of macromolecular crystals can result in improved diffraction data quality compared with data obtained from randomly aligned crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

End-to-end Modeling of Lyot Coronagraph for LUVOIR: Sensitivity to Segment-Level Aberrations

Direct imaging and spectroscopic characterization of atmospheres of Earth-like exoplanets require starlight suppression to detect a faint planetary signal at small angular separations. Future space telescopes will require segmentation to survey a statistically significant population of nearby stars systems by increasing aperture size beyond the limits set by traditional monolithic apertures; however, segmentation also represents an additional challenge due to the introduction of temporal pupil discontinuities in terms of both phase and amplitude. For this study, a baseline Lyot coronagraph is used with the Large UV / Optical /Infrared (LUVOIR) mission’s 15-m on-axis, segmented optical telescope assembly (OTA). We present a high-fidelity, end-to-end modeling approach developed as part of the Segmented Coronagraph Design and Analysis (SCDA) group that includes diffractive optical propagations at the 1e-10 contrast level across the entire optical train including the OTA and intermediate re-imaging optics inside the coronagraph instrument. We perform a tolerancing analysis to assess the contrast sensitivity to wavefront perturbations for a set of key telescope terms including segment-level low-order and mid-spatial frequency aberrations. As an input to the end-to-end telescope model, we use two industry-provided segment-level wavefront aberration datasets pertaining: (1) thermal gradients and accelerations (courtesy of Ball-Aerospace and L3-Harris), and (2) telescope dynamics including line-of-sight and segment jitter (courtesy of Lockheed-Martin). Contrast performance outputs of the coronagraph are fed into a mission design reference simulator to assess the scientific yield sensitivity. End-to-end modeling will incorporate performance improvements due to active wavefront sensing and control and/or segment-level metrology to improve system performance.

Optics↗

Exoplanet Yield Sensitivity for the Hybrid Lyot Coronagraph from end-to-end modeling for LUVOIR-A

NASA's future direct imaging flagship mission will require telescope mirror segmentation to survey a statistically significant population of nearby stellar systems by increasing aperture size beyond that achieved by traditional space-borne monolithic apertures thus far. Segmentation is a path for the size expansion, but it entails a challenge due to the introduction of temporal pupil discontinuities in terms of both phase and amplitude. Modeling of the integrated performance of the coronagraph with the expected dynamical profile of the telescope is an important step toward realistic estimates of the mission's science yields. We present results of a study using the hybrid Lyot coronagraph with a 15-m on-axis, segmented optical telescope assembly (OTA), akin to that of the Large UV / Optical /Infrared (LUVOIR) mission. We have developed a high-fidelity, end-to-end model as part of the Segmented Coronagraph Design and Analysis (SCDA) study that includes diffractive optical propagations at the 1e-10 contrast level across the optical train including the OTA and intermediate re-imaging optics inside the coronagraph instrument. We perform a sensitivity analysis to assess the contrast sensitivity to wavefront perturbations for a set of key telescope terms including segment-level low-order and mid-spatial frequency aberrations and evaluate expected exoplanet yields obtained in the presence of these sets of aberrations. Industry-provided segment-level wavefront aberration datasets involving the following mechanisms are input to the end-to-end model: (1) thermal gradients and accelerations, and (2) telescope dynamics including line-of-sight and segment jitter. Dynamically averaged PSFs in the presence of aberrations are fed into AYO (Altruistic Yield Optimization), a mission design reference simulator, that then assesses the scientific yield sensitivities.

high-contrast imaging↗

Micro-structural characterization of materials using synchrotron hard X-ray imaging techniques

X-ray imaging has been an important tool to study the materials microstructure with the laboratory based sources however the advent of third generation synchrotron sources has introduced new concepts in X-ray imaging such as phase contrast imaging, micro-tomography, fluorescence imaging and diffraction enhance imaging. These techniques are being used to provide information of materials about their density distribution, porosity, geometrical and morphological characteristics at sub-micron scalewith improved contrast. This paper discusses the development of various imaging techniques at synchrotron based imaging beamline Indus-2 and few recent experiments carried out at this facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction

Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an unstained human chromosome using coherent x-ray diffraction. The reconstructed images in two or three dimensions show an axial structure, which has not been observed under unstained conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Structure of Cu in Cs8Na16Cu5Ge131 Type II Clathrate

We have used X-ray absorption spectroscopy (XAS) to investigate the local structure of Cu and Ge in the Cs8Na16Cu5Ge131 type II clathrate. We show that the local structure parameters for Ge (coordination number and distances) are consistent with those derived on the basis of XRD investigation of Cs8Na16Ge136. The EXAFS data suggest that Cu either randomly substitutes for Ge on the clathrate framework or preferentially on the 96g site but not preferentially on the 32e or 8a sites (Wyckoff notation). Furthermore, we find that the Cu-Ge distance is smaller than the Ge-Ge distance by 0.13 Angstroms, indicating a local distortion around the Cu atoms. The estimated degrees of disorder for Cu-Ge and Ge-Ge interactions indicate the Cu-Ge clathrate framework to be relatively stiff, while those for Na-Ge and Cs-Ge interactions corroborate previous observations of strong thermal disorder of the alkali guests in these materials. Our XAS results offer insight into the site substitution of Cu in this material, information unattainable from X-ray diffraction due to the lack of scattering contrast between Cu and Ge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Diffraction-Enhanced Imaging

Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized structures associated with invasive human breast cancer. Using a high-sensitivity Si (3 3 3) reflection, the individual features of breast cancer, including masses, calcifications and spiculations, were observed. DEI-CT yields 14, 5 and 7 times higher CT numbers and 10, 9 and 6 times higher signal-to-noise ratios (SNR) for masses, calcifications and spiculations, respectively, as compared to conventional CT of the same specimen performed using the same detector, x-ray energy and dose. Furthermore, DEI-CT at ten times lower dose yields better SNR than conventional CT. In light of the recent development of a compact DEI prototype using an x-ray tube as its source, these results, acquired at a clinically relevant x-ray energy for which a pre-clinical DEI prototype currently exists, suggest the potential of clinical implementation of mammography with DEI-CT to provide high-contrast, high-resolution images of breast cancer (Parham 2006 PhD Dissertation University of North Carolina at Chapel Hill).

47 OTHER INSTRUMENTATION↗

Closed Loop, DM Diversity-based, Wavefront Correction Algorithm for High Contrast Imaging Systems

High contrast imaging from space relies on coronagraphs to limit diffraction and a wavefront control systems to compensate for imperfections in both the telescope optics and the coronagraph. The extreme contrast required (up to 10(exp -10) for terrestrial planets) puts severe requirements on the wavefront control system, as the achievable contrast is limited by the quality of the wavefront. This paper presents a general closed loop correction algorithm for high contrast imaging coronagraphs by minimizing the energy in a predefined region in the image where terrestrial planets could be found. The estimation part of the algorithm reconstructs the complex field in the image plane using phase diversity caused by the deformable mirror. This method has been shown to achieve faster and better correction than classical speckle nulling.

Give'on, Amir↗

Angular alignment and fidelity of neutron phase-gratings for improved interferometer fringe visibility

The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3% obtained using this moiré interferometer was well below the theoretical prediction of 30% using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo↗

Real-time microstructure of shocked LiF crystals: Use of synchrotron x-rays

We describe the use of a third generation synchrotron facility to obtain in situ, real-time, x-ray diffraction measurements in plate impact experiments. Subnanosecond duration x-ray pulses were utilized to record diffraction data from pure and magnesium-doped LiF single crystals shocked along the [111] and [100] orientations. The peak stresses were 3.0 GPa for the [111] oriented LiF and between 3.0 and 5.0 GPa for the [100] oriented LiF. For these stresses, shock compression along [111] results in elastic deformation and shock compression along [100] results in elastic-plastic deformation. Because of the quality of the synchrotron x-ray pulses, both shifting and broadening of the diffraction data were obtained simultaneously. As expected, shifts for elastic compression and elastic-plastic compression in shocked LiF were consistent with uniaxial and isotropic lattice compression, respectively. More importantly, diffraction patterns from crystals shocked along [100] exhibited substantial broadening due to elastic-plastic deformation. The broadening indicates that the shocked LiF(100) crystals developed substructure with a characteristic size for coherently diffracting domains (0.1-10{micro}m) and a distribution of (100) microlattice-plane rotations ({approx} 1{sup o} wide). In contrast to the LiF(100) results, broadening of the diffraction pattern did not occur for elastically deformed LiF(111). Another important finding was that the amount of lattice disorder for shocked LiF(100) depends on the loading history; the broadening was larger for the magnesium-doped LiF(100) (large elastic precursor) than for ultrapure LiF(100) (small elastic precursor) shocked to the same peak stress. The data are simulated by calculating the diffraction pattern from LiF(100) with a model microstructure consisting of coherently diffracting domains. The lattice orientation and longitudinal strain is assumed uniform within domains, but they vary from domain to domain with Gaussian distributions. Simulations using such a model are in good agreement with the measured diffraction patterns. The principal finding from the present work is that synchrotron x-rays can provide real-time data regarding microstructure changes accompanying shock-induced deformation and structural changes.

43 PARTICLE ACCELERATORS↗

TECHNIQUES FOR HIGH-CONTRAST IMAGING IN MULTI-STAR SYSTEMS. I. SUPER-NYQUIST WAVEFRONT CONTROL

Direct imaging of extra-solar planets is now a reality with the deployment and commissioning of the first generation of specialized ground-based instruments (GPI, SPHERE, P1640, and SCExAO). These systems allow of planets 10{sup 7} times fainter than their host star. For space-based missions (EXCEDE, EXO-C, EXO-S, WFIRST), various teams have demonstrated laboratory contrasts reaching 10{sup −10} within a few diffraction limits from the star. However, all of these current and future systems are designed to detect faint planets around a single host star, while most non-M-dwarf stars such as Alpha Centauri belong to multi-star systems. Direct imaging around binaries/multiple systems at a level of contrast allowing detection of Earth-like planets is challenging because the region of interest is contaminated by the host star's companion in addition to the host itself. Generally, the light leakage is caused by both diffraction and aberrations in the system. Moreover, the region of interest usually falls outside the correcting zone of the deformable mirror (DM) with respect to the companion. Until now, it has been thought that removing the light of a companion star is too challenging, leading to the exclusion of many binary systems from target lists of direct imaging coronographic missions. In this paper, we will show new techniques for high-contrast imaging of planets around multi-star systems and detail the Super-Nyquist Wavefront Control (SNWC) method, which allows wavefront errors to be controlled beyond the nominal control region of the DM. Our simulations have demonstrated that, with SNWC, raw contrasts of at least 5 × 10{sup −9} in a 10% bandwidth are possible.

79 ASTRONOMY AND ASTROPHYSICS↗

An electrically driven terahertz metamaterial diffractive modulator with more than 20 dB of dynamic range

We design and experimentally demonstrate a switchable diffraction grating for terahertz modulation based on planar active metamaterials, where a Schottky gate structure is implemented to tune the metamaterial resonances in real-time via the application of an external voltage bias. The diffraction grating is formed by grouping the active split-ring resonators into an array of independent columns with alternate columns biased. We observe off-axis diffraction over a wide frequency band in contrast to the narrow-band resonances, which permits operation of the device as a relatively high-speed, wide-bandwidth, high-contrast modulator, with more than 20 dB of dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗