Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Data Processing for Hyperspectral Sensors on Small Platforms

Hyperspectral imaging is a very promising technology for nuclear proliferation detection. However, due to size and weight restrictions, small hyperspectral platforms such as satellites and small drones lack the on-board computing resources for accurate, real-time analysis of the enormous flow of data that a continuously operating hyperspectral sensor generates. This severely limits satellite systems, which can collect far more data than what they can telemeter, and hinders the ability of all platforms to adapt their missions on the fly in response to observations. This program addresses the hyperspectral data processing challenge through development of new, fast and accurate algorithms that produce data products in real time. The algorithms circumvent the major computational bottlenecks in existing processing streams, and would be incorporated in lightweight, power-efficient single-board computer systems. The toolkit of fast algorithms will be immediately useful in current and future hyperspectral systems being built by the Government and by private industry, including drone-based systems and satellite constellations that acquire timely global imagery.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Finding Fast Transients in Real Time Using a Novel Light-curve Analysis Algorithm

The current data acquisition rate of astronomical transient surveys and the promise for significantly higher rates in the next decade necessitate the development of novel approaches to analyze astronomical data sets and promptly detect objects of interest. The Deeper, Wider, Faster (DWF) program is a survey focused on the identification of fast-evolving transients, such as fast radio bursts, gamma-ray bursts, and supernova shock breakouts. It employs multifrequency simultaneous coverage of the same part of the sky over several orders of magnitude. Using the Dark Energy Camera mounted on the 4 m Blanco telescope, DWF captures a 20 s g -band exposure every minute, at a typical seeing of ~1'' and an air mass of ~1.5. These optical data are collected simultaneously with observations conducted over the entire electromagnetic spectrum—from radio to γ -rays—as well as cosmic-ray observations. In this paper, we present a novel real-time light-curve analysis algorithm, designed to detect transients in the DWF optical data; this algorithm functions independently from, or in conjunction with, image subtraction. We present a sample of fast transients detected by our algorithm, as well as a false-positive analysis. Our algorithm is customizable and can be tuned to be sensitive to transients evolving over different timescales and flux ranges.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing an aqueous flow cell designed for in situ crystal growth under X-ray nanotomography and effects of radiolysis products

Nucleation and growth of minerals has broad implications in the geological, environmental and materials sciences. Recent developments in fast X-ray nanotomography have enabled imaging of crystal growth in solutions in situ with a resolution of tens of nanometres, far surpassing optical microscopy. Here, a low-cost, custom-designed aqueous flow cell dedicated to the study of heterogeneous nucleation and growth of minerals in aqueous environments is shown. To gauge the effects of radiation damage from the imaging process on growth reactions, radiation-induced morphological changes of barite crystals (hundreds of nanometres to ∼1 µm) that were pre-deposited on the wall of the flow cell were investigated. Under flowing solution, minor to major crystal dissolution was observed when the tomography scan frequency was increased from every 30 min to every 5 min (with a 1 min scan duration). The production of reactive radicals from X-ray induced water radiolysis and decrease of pH close to the surface of barite are likely responsible for the observed dissolution. The flow cell shown here can possibly be adopted to study a wide range of other chemical reactions in solutions beyond crystal nucleation and growth where the combination of fast flow and fast scan can be used to mitigate the radiation effects.

36 MATERIALS SCIENCE↗

Multifrequency Models of Black Hole Photon Rings from Low-luminosity Accretion Disks

Images of black holes encode both astrophysical and gravitational properties. Detecting highly lensed features in images can differentiate between these two effects. We present an accretion disk emission model coupled to the Adaptive Analytical Ray Tracing (AART) code that allows a fast parameter space exploration of black hole photon ring images produced from synchrotron emission from 10 to 670 GHz. As an application, we systematically study several disk models and compute their total flux density, average radii, and optical depth. The model parameters are chosen around fiducial values calibrated to general relativistic magnetohydrodynamic (GRMHD) simulations and observations of M87*. For the parameter space studied, we characterize the transition between optically thin and thick regimes and the frequency at which the first photon ring is observable. Our results highlight the need for careful definitions of photon ring radius in the image domain, as in certain models the highly lensed photon ring is dimmer than the direct emission at certain angles. We find that at low frequencies the ring radii are set by the electron temperature, while at higher frequencies the magnetic field strength plays a more significant role, demonstrating how multifrequency analysis can also be used to infer plasma parameters. Lastly, we show how our implementation can qualitatively reproduce multifrequency black hole images from GRMHD simulations when adding time variability to our disk model through Gaussian random fields. This approach provides a new method for simulating observations from the Event Horizon Telescope and the proposed Black Hole Explorer space mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Octofitter: Fast, Flexible, and Accurate Orbit Modeling to Detect Exoplanets

As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images can be freely combined with the radial velocity and proper motion anomaly, even without a confirmed detection in any single epoch. In this paper, we present a fast and differentiable multimethod orbit-modeling and planet detection code called Octofitter. This code is designed to be highly modular and allows users to easily adjust priors, change parameterizations, and specify arbitrary function relations between the parameters of one or more planets. Octofitter further supplies tools for examining model outputs including prior and posterior predictive checks and simulation-based calibration. We demonstrate the capabilities of Octofitter on real and simulated data from different instruments and methods, including HD 91312, simulated JWST/NIRISS aperture masking interferometry observations, radial velocity curves, and grids of images from the Gemini Planet Imager. We show that Octofitter can reliably recover faint planets in long sequences of images with arbitrary orbital motion. This publicly available tool will enable the broad application of multiepoch and multimethod exoplanet detection, which could improve how future targeted ground- and space-based surveys are performed. Finally, its rapid convergence makes it a useful addition to the existing ecosystem of tools for modeling the orbits of directly imaged planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an Image-Derived Input Function for Kinetic Modeling of Nicotinic Acetylcholine Receptor-Binding PET Ligands in Mice

Positron emission tomography (PET) radioligands that bind with high-affinity to α4β2-type nicotinic receptors (α4β2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[ 18 F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [ 18 F]Nifene, displaying similar pKa and binding affinity to nicotine. Time–activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the β2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.

2-FA85380↗

Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF 4 :Er 3+ ,Yb 3+ /NaGdF 4 upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.

47 OTHER INSTRUMENTATION↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Synchrotron X-ray-induced Synthesis of Copper Hydroxide Nitrate Nanoplates on Cu Thin Films in an Ambient Atmosphere

Synchrotron X-rays are widely used for material characterizations. However, they can also ionize atoms and molecules to damage and manipulate probed materials. We report here an X-ray-induced growth of copper hydroxide nitrate, Cu 2 (OH) 3 NO 3 , on copper thin films in the ambient atmosphere without solvents and thermal treatment. In situ synchrotron X-ray diffraction measurements showed that the time-dependent growth process of the Cu 2 (OH) 3 NO 3 is accompanied by the consumption of Cu metal and can be described by a sigmoidal model. The growth rate was reduced after the initial fast growth period. Scanning electron microscopy (SEM) images show that the isolated islands of Cu 2 (OH) 3 NO 3 nanoplates formed in the beginning, which grew together with new nanoplates formed under continued X-ray irradiation. The result demonstrated that high-flux synchrotron X-rays may provide an unconventional approach to synthesizing and manipulating materials, which will inspire future investigation both experimentally and theoretically.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep learning enables nanoscale X-ray 3D imaging with limited data

Deep neural network can greatly improve tomography reconstruction with limited data. A recent effort of combining ptycho-tomography model with the 3D U-net demonstrated a significant reduction in both the number of projections and computation time, and showed its potential for integrated circuit imaging that requires high-resolution and fast measurement speed.

47 OTHER INSTRUMENTATION↗

Role of defects in ultra-high gain in fast planar tin gallium oxide UV-C photodetector by MBE

Here we report ultra-high responsivity of epitaxial (Sn x Ga 1–x ) 2 O 3 (TGO) Schottky UV-C photodetectors and experimentally identified the source of gain as deep-level defects, supported by first principles calculations. Epitaxial TGO films were grown by plasma-assisted molecular beam epitaxy on (–201) oriented n-type β-Ga 2 O 3 substrates. Fabricated vertical Schottky devices exhibited peak responsivities as high as 3.5 ×10 4 A/W at –5 V applied bias under 250 nm illumination with sharp cutoff shorter than 280 nm and fast rise/fall time in milliseconds order. Hyperspectral imaging cathodoluminescence (CL) spectra were examined to find the mid-bandgap defects, the source of this high gain. Irrespective of different tin mole fractions, the TGO epilayer exhibited extra CL peaks at the green band (~2.20 eV) not seen in β-Ga 2 O 3 along with enhancement of the blue emission-band (~2.64 eV) and suppression of the UV emission-band. Based on hybrid functional calculations of the optical emission expected for defects involving Sn in β-Ga 2 O 3 , V Ga –Sn complexes are proposed as potential defect origins of the observed green and blue emission-bands. Such complexes behave as acceptors that can efficiently trap photogenerated holes and are predicted to be predominantly responsible for the ultra-high photoconductive gain in the Sn-alloyed Ga 2 O 3 devices by means of thermionic emission and electron tunneling. Regenerating the V Ga –Sn defect complexes by optimizing the growth techniques, we have demonstrated a planar Schottky UV-C photodetector of the highest peak responsivity.

36 MATERIALS SCIENCE↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Lowering the computational barrier: Partially Bayesian neural networks for transparency in medical imaging AI

Deep Neural Networks (DNNs) can provide clinicians with fast and accurate predictions that are highly valuable for high-stakes medical decision-making, such as in brain tumor segmentation and treatment planning. However, these models largely lack transparency about the uncertainty in their predictions, potentially giving clinicians a false sense of reliability that may lead to grave consequences in patient care. Growing calls for Transparent and Responsible AI have promoted Uncertainty Quantification (UQ) to capture and communicate uncertainty in a systematic and principled manner. However, traditional Bayesian UQ methods remain prohibitively costly for large, million-dimensional tumor segmentation DNNs such as the U-Net. In this work, we discuss a computationally-efficient UQ approach via the partially Bayesian neural networks (pBNN). In pBNN, only a single layer, strategically selected based on gradient-based sensitivity analysis, is targeted for Bayesian inference. We illustrate the effectiveness of pBNN in capturing the full uncertainty for a 7.8-million parameter U-Net. We also demonstrate how practitioners and model developers can use the pBNN's predictions to better understand the model's capabilities and behavior.

97 MATHEMATICS AND COMPUTING↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

A Bright, Photostable, and Far-Red Dye That Enables Multicolor, Time-Lapse, and Super-Resolution Imaging of Acidic Organelles

Lysosomes have long been known for their acidic lumens and efficient degradation of cellular byproducts. In recent years, it has become clear that their function is far more sophisticated, involving multiple cell signaling pathways and interactions with other organelles. Unfortunately, their acidic interior, fast dynamics, and small size make lysosomes difficult to image with fluorescence microscopy. Here we report a far-red small molecule, HMSiR 680 -Me, that fluoresces only under acidic conditions, causing selective labeling of acidic organelles in live cells. HMSiR 680 -Me can be used alongside other far-red dyes in multicolor imaging experiments and is superior to existing lysosome probes in terms of photostability and maintaining cell health and lysosome motility. We demonstrate that HMSiR 680 -Me is compatible with overnight time-lapse experiments as well as time-lapse super-resolution microscopy with a frame rate of 1.5 fps for at least 1000 frames. HMSiR 680 -Me can also be used alongside silicon rhodamine dyes in a multiplexed super-resolution microscopy experiment to visualize interactions between mitochondria and lysosomes with only a single excitation laser and simultaneous depletion. We envision this dye permitting a more detailed study of the role of lysosomes in dynamic cellular processes and disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗