At least 217 records · Page 12

Hybrid Analytics Solution for Power Plant Operations

Expert Microsystems, Inc., MapEx Software Inc. and XMPLR Energy LLC have teamed to submit a proposal to the US Department of Energy’s Office of Fossil Energy to improve the efficiency, reliability and flexibility of existing coal-based power plants. The project, titled Hybrid Analytics Solution to Improve Coal Power Plant Operations (the “Hybrid Analytics” project), will develop, demonstrate and commercialize a novel approach that integrates two proven real-time monitoring techniques. The Hybrid Analytics approach integrates into a single, integrated solution: a) an established, advanced data-driven analytics solution that includes artificial intelligence, advanced pattern recognition and machine-learning techniques and b) a well-proven, first principle thermal heat balance model solution. The future role of coal plants will depend on the ability to cycle and follow loads to meet marginal power demands, accommodate renewables and support the grid. Essential to success in this new role is a plant’s ability to maintain high reliability, efficiency and flexibility. However, these changing operational demands put significant stresses on power plant components that directly impact the ability to deliver these requirements. In the past, plants have independently monitored performance using physics-based solutions (heat rate, boiler losses, etc.) and reliability using data-driven analytics (advanced pattern recognition). The Hybrid Analytics solution integrates both approaches to enhance fault detection, provide automated diagnostics and estimates of remaining time to act, and provide critical, enhanced and accurate real-time information to coal plant operators. As a result, coal plants can improve efficiency, reliability, and flexibility and can cost-effectively maintain their key role in the power delivery system.

01 COAL, LIGNITE, AND PEAT↗

The infeasibility of quantifying the reliability of life-critical real-time software

This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods, whether these methods are applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance - separately programmed versions fail independently - is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region, and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.

Butler, Ricky W.↗

The Infeasibility of Quantifying the Reliability of Life-Critical Real-Time Software

This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exhorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance separately programmed versions fail independently is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.

Butler, Ricky W.↗

Distribution of Slip at the Northern Sumatran Fault System

We model spatial variations in horizontal displacements of 117 geodetic sites measured during annual surveys in 1989-1996 with the Global Positioning System (GPS) as elastic strain across a locked strike-slip fault to infer the contemporary slip rate, locking depth, and location of the Sumatran fault (SF) in northern Sumatra (1 S-3 N). GPS-derived slip rate estimates increase slightly northward from 23 plus or minus 3 mm/yr at 0.8 deg S to 26 plus or minus 2mm/yr at 2.7 N. They agree with geologic estimates north of the Equator, but at 0.5 S they are about 10 mm/yr higher. Strain appears to be distributed asymmetrically about the fault. South of 2 N, about 5 mm/yr of shear is required within the offshore forearc, west of the fault, to achieve a closer agreement of fault locations inferred from GPS velocities with geologically identified traces of the SF. Locking depth estimates are on the order of 10-20 km. The western branch of the major fault bifurcation near 1 N slips at a rate five times higher than the eastern branch. The two main strands of the fault at the northwestern tip of Sumatra (5.5 N) appear to be nearly free of horizontal strain; significant slip must occur away from the two strands, probably further east at two other geologically active branches. The Banda Aceh embayment is extruded to the northwest at a rate of 5 plus or minus 2 mm/yr. Within the estimated velocity uncertainties of several mm/yr, fault-normal deformation along the SF is insignificant. Almost strain free, the northern part of the back-arc basin is part of a rigid Sunda shelf, while the northern forearc is subjected to 8 plus or minus 5 x 10 (exp -8)/yr of extension nearly parallel to the arc.

Genrich, J. F.↗

Variations of Stress Parameters in the Southern California Plate Boundary Around the South Central Transverse Ranges

We examine the stress field in Southern California with a focus on the region near the South Central Transverse Ranges (SCTR), using a refined stress inversion methodology. We independently invert declustered and aftershocks focal mechanisms from the years 1981 to 2017. Comparisons between the stress field orientations and the stress ratios from these inversions provide information on local sources of the stress field. Regionally, the SHmax tends to be toward NNE and the stress ratios vary from transtensional stress regime near the Eastern California Shear Zone (ECSZ), to strike-slip faulting near the SCTR, and toward transpression near the Western Transverse Ranges. Detailed analysis of stress parameters near the SCTR indicates deviations from the regional strike-slip faulting including the following: (1) The San Bernardino Mountain area shows S Hmax direction toward NNW and transpressional stress components likely associated with the motions of the San Andreas Fault and ECSZ; (2) the Cajon Pass and San Gorgonio Pass show transpressional stress regime near the bottom of the seismogenic zone likely associated with the elevated topography; and (3) in Crafton Hills, rotation of the principal stress plunges and SHmax direction and transtensional stress regime below ~10 km, along with lower estimated apparent friction coefficient, suggest a weak fault possibly associated with deep creep. The performed multiscale analysis resolves effects of regional and local loadings. The average stress parameters in the analyzed 37 years do not show significant temporal variations of stress field near the SCTR region.

58 GEOSCIENCES↗

Blockchain for Fault-Tolerant Grid Operations

Radial topology and vast geographic coverage make distribution systems prone to widespread power outages upon the failure of a single (or multiple) upstream component. Fault-handling algorithms depend heavily on correct estimations of the system’s state to effectively isolate the affected area and reduce the number of affected customers while maintaining operational safety. The work described here leverages the core features of distributed, consensus-based decision-making processes and the immutability of blockchain, and demonstrates their value in improving fault-tolerant grid operations. In this work, blockchain was used to create a trusted data-sharing platform that enables independent actors to reconstruct the system state; this enables distributed resources to make intelligent decisions with limited knowledge. Although the process requires data sharing, its algorithms have been designed to limit the amount of private information that is exchanged, which helps preserve business-sensitive data and maintain customer privacy. In addition, by reducing the information that must be shared, the communication requirements are also reduced; (however, an in-depth analysis of the communication requirements is beyond the scope of this project). The proposed use cases are intended to represent a foundational basis for third parties to develop functional solutions that can eventually be deployed in the field. To further provide guidance, the envisioned use cases have incorporated design requirements that consider the blockchain characteristics and a need to limit information from surrounding resources, which preserve the assumption and the possibility that such resources could belong to different entities. This report presents a detailed design of the three use cases with the tools needed to enable the analysis being tested. The implemented gross error detection method can detect mismatches when the error exceeds 3.8 times the sensor’s rated accuracy. Detection of the circuit breaker state successfully identified the correct states across all simulation tests. A distribution-system power-flow solution in the simulator OpenDSS generally possesses a convergency tolerance of 0.01% on the voltage magnitude. The evaluation of possible reconnection using voltage magnitude—preserving the data ownership—has a voltage magnitude difference smaller than 0.001% from the OpenDSS result. The results preserving data ownership have a difference within the expected power flow tolerance with full knowledge of the system, which surpasses expectations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precambrian Crystalline Basement Properties From Pressure History Matching and Implications for Induced Seismicity in the US Midcontinent

Injection-induced seismicity across the US midcontinent has almost exclusively occurred in the crystalline basement that underlies the Arbuckle Group aquifer and its equivalents, the primary wastewater disposal zone in this region. However, the properties of the basement are not well known. Newly compiled data, from Class I wells in Kansas, provide a unique record of pressures in the Arbuckle and an opportunity to constrain the reservoir-scale properties of the basement such as permeability, diffusivity, and specific storage. Constraints on these parameters are critical for modeling fluid flow and pressures across the entire Arbuckle-basement system, and are necessary for accurate evaluation and prediction of injection-induced earthquakes. Here, we present a detailed, three-dimensional geological and pressure history-matched numerical model for the Arbuckle and basement, based on data from >400 wells covering a large region in south-central Kansas, where injection-induced seismicity has been concentrated since 2014. Simulations of dynamic data from 319 wells indicate that Arbuckle pressures have increased by 1.1 MPa in high injection rate areas and an overpressure of <0.1 MPa may be the cause of seismicity in the basement. Pressure-history matching also yields the likely range in porosity (0.3%–7%), permeability (0.1–0.7 mD), and diffusivity (0.004–0.07 m2 /s) for the basement. The resulting estimates suggest reservoir-scale properties of the basement are enhanced by faults and fractures. Importantly, the diffusivities determined in this study are lower than estimates derived from Kansas earthquake triggering fronts, and suggest that such seismicity-based techniques may have limitations, particularly where spacetime patterns between injection and seismicity are complex.

58 GEOSCIENCES↗

Collaborative Research: Properties and Dynamics of the Shallow Crust (Final Report)

Ground motions recorded at one location are often extrapolated to nearby regions within a given radius. Here, we explore the appropriateness of spatial extrapolation using data from seven small aperture seismic network deployments in southern California. Six of these deployments are linear arrays of 4-13 stations, and one is a 2D array of 13 stations at Pinyon Flats Observatory. The spatial footprint array diameters are 3 km or less, and each array was operational for a year or more. From our base catalog (M2.5+ earthquakes; 4038 events; September 2010 - June 2023), automated methods remove temporally overprinted waveforms from nearby events (< 5 km) in quick succession (< 5 min) and data with nonviable waveforms. These 200 samples per second data are filtered at 0.5-25 Hz and must have signal-tonoise ratios (SNRs) of 2.5+. Peak ground acceleration (PGA) and peak ground velocity (PGV) are derived individually from the maximum absolute values of each of the 3-component waveforms (vertical, northsouth, and east-west). Five of the seven arrays traverse the San Jacinto fault, and two do not. Ground motion observations are compared with theoretical estimates from Abrahamson et al., 2014. On average, arrays deployed within and across fault zones consistently record ground motions above theoretical expectations, whereas off-fault arrays record ground motions at or slightly below theoretical expectations. We attribute these differences to site conditions because these trends prevail for the full data suites. For each network and each individual channel, the coefficient of variation indicates that the standard deviations are ~30±6% of the mean. Exploring relative ground motion contributions from all three channels (ternary plots), as expected, most data show that vertical ground motions are attenuated compared to horizontal ones. However, this is not always the case for RA array data, where vertical motions can be ~2-3 times larger than horizontal motions for select events near Cahuilla, CA. These anomalously high vertical motions are focal mechanism-related. These results suggest that ternary plots created using only a small amount of data can be used as a data quality metric and a tool to find anomalous features in three-component data.

58 GEOSCIENCES↗

GPS measurements of strain accumulation across the Imperial Valley, California: 1986-1989

The Global Positioning System (GPS) data collected in southern California from 1986 to 1989 indicate considerable strain accumulation across the Imperial Valley. Displacements are computed at 29 stations in and near the valley from 1986 to 1988, and at 11 sites from 1988 to 1989. The earlier measurements indicate 5.9 +/- 1.0 cm/yr right-lateral differential velocity across the valley, although the data are heavily influenced by the 1987 Superstition Hills earthquake sequence. Some measurements, especially the east-trending displacements, are suspects for large errors. The 1988 to 1989 GPS displacements are best modeled by 5.2 +/- 0.9 cm/yr of valley crossing deformation, but rates calculated from conventional geodetic measurements (3.4 to 4.3 cm/yr) fit the data nearly as well. There is evidence from GPS and Very Long Base Interferometry (VLBI) observations that the present slip rate along the southern San Andreas fault is smaller than the long-term geologic estimate, suggesting a lower earthquake potential than is currently assumed. Correspondingly, a higher earthquake potential is indicated for the San Jacinto fault. The Imperial Valley GPS sites form part of a 183 station network in southern California and northern Baja California, which spans a cross-section of the North American-Pacific plate boundary.

Larsen, Shawn↗

Global Positioning System measurements of strain accumulation across the Imperial Valley, California - 1986-1989

The Global Positioning System (GPS) data collected in southern California from 1986 to 1989 indicate considerable strain accumulation across the Imperial Valley. Displacements are computed at 29 stations in and near the valley from 1986 to 1988, and at 11 sites from 1988 to 1989. The earlier measurements indicate 5.9 =/- 1.0 cm/yr right-lateral differential velocity across the valley, although the data are heavily influenced by the 1987 Superstition Hills earthquake sequence. Some measurements, especially the east-trending displacements, are suspects for large errors. The 1988 to 1989 GPS displacements are best modeled by 5.2 =/- 0.9 cm/yr of valley crossing deformation, but rates calculated from conventional geodetic measurements (3.4 to 4.3 cm/yr) fit the data nearly as well. There is evidence from GPS and Very Long Base Interferometry (VLBI) observations that the present slip rate along the southern San Andreas fault is smaller than the long-term geologic estimate, suggesting a lower earthquake potential than is currently assumed. Correspondingly, a higher earthquake potential is indicated for the San Jacinto fault. The Imperial Valley GPS sites form part of a 183 station network in southern California and northern Baja California, which spans a cross-section of the North American-Pacific plate boundary.

Larsen, Shawn↗

Artificial Neural Network-based State Estimation for Low Observable, Unbalanced Microgrids for Microgrid Building Blocks

The microgrid building blocks (MBB) were proposed as microgrid components with combined sub-components with power conversion, communication, and microgrid control capability, or a subset of such sub-components. This work addresses the microgrid controller, present in an MBB, which requires accurate state estimation to perform its tasks, including for monitoring, power flow (dispatch), fault detection, etc. In this paper, an artificial neural network (ANN)-based framework for state estimation is proposed for an MBB, especially for unbalanced and low observable microgrids. To overcome the challenge of low observability in unbalanced systems, a concept of extended adjacent matrix is introduced to reduce the required number of measurements for state estimation. Addressing the challenges, a feed forward neural network (FNN) is utilized to enhance estimation accuracy and reliability with the reduced number of measurements. The proposed state estimation is validated through extensive simulations on a microgrid, which was achieved from the modified IEEE 34-bus distribution test feeder with multiple distributed energy resources (DERs) and demonstrated superior performance in estimation accuracy and low observability.

Choi, Jongchan↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the impact of error detection on computer performance

Conventionally, reliability analyses either assume that a fault/error is detected immediately following its occurrence, or neglect damages caused by latent errors. Though unrealistic, this assumption was imposed in order to avoid the difficulty of determining the respective probabilities that a fault induces an error and the error is then detected in a random amount of time after its occurrence. As a remedy for this problem a model is proposed to analyze the impact of error detection on computer performance under moderate assumptions. Error latency, the time interval between occurrence and the moment of detection, is used to measure the effectiveness of a detection mechanism. This model is used to: (1) predict the probability of producing an unreliable result, and (2) estimate the loss of computation due to fault and/or error.

Shin, K. C.↗

Some methods of estimating a coverage parameter

To demonstrate the high reliability of fault-tolerant computing systems, experimental testing can be performed by injecting faults into their hardware and observing the times needed to detect and isolate failed components and reconfigure the good components. Coverage, a parameter measuring continued system success, is the probability that recovery occurs before other, perhaps catastrophic, component failures occur. Methods of estimating coverage are given for the case of randomly selecting a subset of the pins or chips for testing. Pin-level samples of times to recovery are treated by the Type I censoring model often used in life testing.

Lee, L. D.↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996).

Ramirez, W. Fred↗

Testing of reliability - Analysis tools

An outline is presented of issues raised in verifying the accuracy of reliability analysis tools. State-of-the-art reliability analysis tools implement various decomposition, aggregation, and estimation techniques to compute the reliability of a diversity of complex fault-tolerant computer systems. However, no formal methodology has been formulated for validating the reliability estimates produced by these tools. The author presents three states of testing that can be performed on most reliability analysis tools to effectively increase confidence in a tool. These testing stages were applied to the SURE (semi-Markov Unreliability Range Evaluator) reliability analysis tool, and the results of the testing are discussed.

Hayhurst, Kelly J.↗

The earthquake deformation cycle - Examples from South America and the western United States

Observations of an interplate, thrust earthquake in Argentina are used to characterize a cyclic pattern of earthquake deformation. The cycle consists of steady strain accumulation, coseismic strain release, a period of continued strain release due to afterslip, and rapid postseismic strain accumulations which decrease exponentially and grade into steady strain accumulation. The cycle is used to interpret the deformation of three earthquakes in California, Alaska, and Montana, focusing on the mechanics of strain release. The results suggest that large postseismic movements can occur for strike-slip, thrust, and normal fault events. It is found that viscoelastic relaxation and postseismic afterslip should be incorporated in models of earthquake-related deformation. The use of these results for estimating earthquake repeat times from geodetic observations near active faults is considered.

Reilinger, Robert↗