Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency couplings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Viscous effects on the resonance of a slotted wind tunnel using finite elements

Prompted by the fact that wind tunnel flutter and oscillatory airload measurements are affected by acoustic vibration mode coupling when the model frequency lies near a wind tunnel resonance frequency, a numerical method has been developed for design sensitivity analysis. Solid curves represent the resonant frequency for the slot, without considering the slot's viscosity. While the viscosity effect decreases with increasing slot width, the viscosity effect also decreases as the slot width approaches zero.

Lee, IN↗

Spot damping anomalies

Vibration control through spot damping treatment can sometimes produce the anomalous result that some of the 'damped' modes either remain undamped or have more damping than anticipated. Several lumped parameter examples are presented, demonstrating that this is most pronounced when dissimilar modes have the same natural frequency. A plate vibration example is also presented which shows that a spot damping treatment can fail to damp certain dissimilar modes having the same natural frequency, while others have twice the damping expected. It is shown that frequency matching of damping coupled modes employing spot damping results in nodal and antinodal points at the point of application of the spot damping, and that this is the basis of the anomalous result.

Young, M. I.↗

Charge transfer polarisation wave and carrier pairing in the high T(sub c) copper oxides

The High T(sub c) oxides are highly polarizable materials and are charge transfer insulators. The charge transfer polarization wave formalism is developed in these oxides. The dispersion relationships due to long range dipole-dipole interaction of a charge transfer dipole lattice are obtained in 3-D and 2-D. These are high frequency bosons and their coupling with carriers is weak and antiadiabatic in nature. As a result, the mass renormalization of the carriers is negligible in complete contrast to conventional electron-phonon interaction, that give polarons and bipolarons. Both bound and superconducting pairing is discussed for a model Hamiltonian valid in the antiadiabatic regime, both in 3-D and 2-D. The stability of the charge transfer dipole lattice has interesting consequences that are discussed.

Chakraverty, B. K.↗

Experimental observations on the relationship between stagnation region flow oscillations and eddy shedding for circular cylinder

Measurements indicate a direct coupling between the dominant frequencies of flow oscillations at the leading-edge stagnation region, laminar-separation unsteadiness, and the vortex shedding. An array of surface mounted, micro-thin hot-films were used to simultaneously determine the state of the boundary layer along the surfaced of a circular cylinder, and vortex shedding was monitored by a hot wire placed in its wake.

Mangalam, S. M.↗

Interactions among convection, magnetic fields and p-mode oscillations in the sun

Two papers on different aspects of the excitation and damping of solar oscillations were accepted for publication in the Astrophysical Journal. The first paper evaluates the rate at which turbulent convection feeds energy into individual p-modes. It is shown that stochastic excitation by turbulent convection provides a satisfactory fit to the product of the mode energies and linewidths. A somewhat surprising conclusion is that entropy fluctuations are about an order of magnitude more significant than are fluctuations of the Reynolds stress in exciting p-modes. However, entropy fluctuations cannot excite f-modes. This may account for the relatively low energies of the f-modes compared to those of the p-modes. The second paper explores the role of scattering of acoustic modes by turbulent velocity fluctuations. Scattering of a mode is concentrated near the top of its acoustic cavity. Because the turbulence has low Mach number, scattering couples modes having similar frequencies. Its net effects are to increase the linewidths of all modes and to transfer energy from p-modes to f-modes. Scattering is likely to be the dominant source for the linewidths of p-modes. In particular, it may account for the unexpectedly large linewidths measured for low frequency modes. Copies of preprints of the two papers referred to above are attached. The remainder of the report is devoted to a description of unpublished results.

Goldreich, Peter↗

Langmuir Probe Measurements in an Inductively Coupled Ar/CF4 Plasmas

Technological advancement in the microelectronics industry requires an understanding of the physical and chemical processes occurring in plasmas of fluorocarbon gases, such as carbon tetrafluoride (CF4) which is commonly used as an etchant, and their mixtures to optimize various operating parameters. In this paper we report data on electron number density (ne), electron temperature'(Te), electron energy distribution function (EEDF), mean electron energy, ion number density (ni), and plasma potential (Vp) measured by using Langmuir probe in an inductively coupled 13.56 MHz radio frequency plasmas generated in 50%Ar:50%CF4 mixture in the GEC cell. The probe data were recorded at various radial positions providing radial profiles of these plasma parameters at 10-50 mTorr pressures and 200 W and 300 W of RF power. Present measurements indicate that the electron and ion number densities increase with increase in pressure and power. Whereas the plasma potential and electron temperature decrease with increase in pressure, and they weakly depend on RF power. The radial profiles exhibit that the electron and ion number densities and the plasma potential peak at the center of the plasma with an exponential fall away from it, while the electron temperature has a minimum at the center and it increases steadily towards the electrode edge. The EEDFs have a characteristic drop near the low energy end at all pressures and pressures and their shapes represent non-Maxwellian plasma and exhibit more like Druyvesteyn energy distribution.v

Rao, M. V. V. S.↗

Magnetic-Field-Response Measurement-Acquisition System

A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a response inflection. The "transmit-receive-compare" of sequential harmonics is repeated until the inflection is identified. The harmonic producing the amplitude inflection is the sensor resonant frequency. Resonant frequency and response amplitude are stored and then correlated to calibration data.

Woodward, Stanley E.↗

Observations of Traveling Crossflow Resonant Triad Interactions on a Swept Wing

Experimental evidence indicates the presence of a triad resonance interaction between traveling crossflow modes in a swept wing flow. Results indicate that this interaction occurs when the stationary and traveling crossflow modes have similar and relatively low amplitudes (approx.1% to 6% of the total freestream velocity). The resonant interaction occurs at instability amplitudes well below those typically known to cause transition, yet transition is observed to occur just downstream of the resonance. In each case, two primary linearly unstable traveling crossflow modes are nonlinearly coupled to a higher frequency linearly stable mode at the sum of their frequencies. The higher-frequency mode is linearly stable and presumed to exist as a consequence of the interaction of the two primary modes. Autoand cross-bicoherence are used to determine the extent of phase-matching between the modes, and wavenumber matching confirms the triad resonant nature of the interaction. The bicoherence results indicate a spectral broadening mechanism and the potential path to early transition. The implications for laminar flow control in swept wing flows are significant. Even if stationary crossflow modes remain subcritical, traveling crossflow interactions can lead to early transition.

Eppink, Jenna L.↗

Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths

The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.

cryogenically cooled superconductorinsulator- supe↗

Plume Characterization of a Laboratory Model 22 N GPIM Thruster via High-Frequency Raman Spectroscopy

The Green Propellant Infusion Mission (GPIM) will demonstrate the capability of a green propulsion system, specifically, one using the monopropellant, AF-M315E. One of the risks identified for GPIM is potential contamination of sensitive areas of the spacecraft from the effluents in the plumes of AF-M315E thrusters. Plume characterization of a laboratory-model 22 N thruster via optical diagnostics was conducted at NASA GRC in a space-simulated environment. A high-frequency pulsed laser was coupled with an electron-multiplied ICCD camera to perform Raman spectroscopy in the near-field, low-pressure plume. The Raman data yielded plume constituents and temperatures over a range of thruster chamber pressures and as a function of thruster (catalyst) operating time. Schlieren images of the near-field plume enabled calculation of plume velocities and revealed general plume structure of the otherwise invisible plume. The measured velocities are compared to those predicted by a two-dimensional, kinetic model. Trends in data and numerical results are presented from catalyst mid-life to end-of-life. The results of this investigation were coupled with the Raman and Schlieren data to provide an anchor for plume impingement analysis presented in a companion paper. The results of both analyses will be used to improve understanding of the nature of AF-M315E plumes and their impacts to GPIM and other future missions.

Raman Spectroscopy↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Investigation of Cloud Interior Structure Using a Tomographic Technique Based on Radon Transform. Application to the Measurements Made by the Research Scanning Polarimeter During CAMP2Ex

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP's uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid-water cloud droplet sizes using the rainbow structure observed in the polarized reflectance measurements. The RSP observations also provide for derivation of 2D field of extinction coefficient inside the cloud using a tomographic technique. This technique utilizes the family of cloud shapes derived using "cutout" technique and corresponding to a number of thresholds in total reflectance (separating bright cloud from its darker background). These shapes can be interpreted as level curves of an abstract "reflectance density", which is then used for derivation of the directional cloud optical thickness (dCOT) tomogram. The latter is a collection of dCOTs parameterized by the angles and offsets of the corresponding view rays (chords) relative to the cloud center. After this, the inverse Radon Transform (the mathematical basis of the X-ray com-puter tomography) is applied to the dCOT tomogram yielding 2D spatial distribution of the extinction coefficient. The later can be converted into droplet number concentration using the droplet size profiles derived from the RSP's polarized reflectance measurements. After tests on synthetic data this technique was applied to real RSP measurements from NASA's Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) conducted in the vicinity of the Philippines during the Southwest Monsoon (August–September 2019). We have investigated the interiors of a number of clouds observed during CAMP2Ex focusing on Cu and CuCg (Tcu) cases. Our retrievals were routinely compared with the correlative measurements by lidar (HSRL-2) and cloud radar (APR-3) that were deployed on the same airborne platform (NASA P-3B) during this field experiment.

Research Scanning Polarimeter↗

Symmetry breaking in O4(+): An application of the Brueckner coupled-cluster method

A recent calculation of the antisymmetric stretch frequency for the rectangular structure of quartet O4(+) using the singles and doubles quadratic configuration interaction method with a perturbational estimate of connected triple excitations (QCISD(T)) method gave a value of 3710 cm(exp -1). This anomalous frequency is shown to be a consequence of symmetry breaking effects, which occur even though the QCISD(T) solution derived from a delocalized SCF reference function lies energetically well below the two localized (symmetry-broken) solutions at the equilibrium geometry. The symmetry breaking is almost eliminated at the CCSD level of theory, but the small remaining symmetry breaking effects are magnified at the CCSD(T) level of theory so that the antisymmetric stretch frequency is still significantly in error. The use of the Brueckner coupled cluster method, however, leads to a symmetrical solution which is free of symmetry breaking effects, with an antisymmetric stretch frequency of 1322 cm(exp -1), in good agreement with our earlier calculations using the complete active space self consistent field/complete active space state interaction (CASSCF/CASSI) method.

Barnes, Leslie A.↗

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

Vibrational Spectrum of (CO)2 on Cu(100): Quantum Calculations with 18 Coupled Mode

We report calculations of the vibrational frequencies of CO dimer on Cu(100) using recently developed vibrational self-consistent field code. Eighteen modes are treated explicitly within three modes coupling representation. Nine symmetry distinct doublets are observed and the corresponding frequencies are computed. The thermally broadened spectrum of the CO-stretch fundamental is calculated at various temperatures. Both the temperature and coverage dependence of both the average CO-stretch frequency and the corresponding line-width are consistent with experimentally observed trends. The document contains no classified information International clearance is needed.

Dzegilenko, Fedor↗

Solar array flight experiment

This is a closed form solution for the longitudinal oscillation of the Solar Array Flight Experiment (SAFE) blanket for all phases of deployment. The frequency response shows that the blanket frequency increases shortly before full deployment. That fact causes a coupling between the mast and the blanket frequency but, because of the relatively high speed of deployment, a buildup of resonance is unlikely.

Slaby, J.↗

Synchrotron infrared spectroscopy at megabar pressures - Vibrational dynamics of hydrogen to 180 GPa

New techniques for measuring infrared spectra at megabar pressures using synchrotron radiation have been developed and applied to study the Q1(1), Qi(1) + Si(0), and QR(J) vibrational transitions of solid hydrogen to 180 GPa. The frequency difference between the Q1(1) infrared and Raman vibrons increases from 3/cm (zero pressure) to 510/cm (180 GPa), indicating a dramatic increase in intermolecular coupling with pressure. A negative frequency shift is observed for the infrared vibron above 140 GPa. A significant increase in frequency and LO-TO splitting of the lattice phonon is also documented.

Hanfland, M.↗

Ultrafast Narrow Band Modulation of VCSELs

Multimode beating was greatly enhanced by taking output from part (e.g., half) of the output facet. Simpler sources of microwaves and millimeter waves of various frequencies were generated by varying the VCSEL diameter in a single multimode VCSEL our coupling of a few VCSELs. Breathing frequency in multi-mode operations affects modulation response and bandwidth. Optimizing RO frequency and mode beating frequency could potentially expand bandwidths suitable for wide band digital communications.

Ning, Cun-Zheng↗