Search NASA⌕ Search

SEARCH · Search NASA

Results for “geothermal resource data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

204 records · Page 12

Analysis of Geothermal Resources in Three Texas Counties

This project updates the geothermal resources beneath our oil and gas fields, as part of the research for the Texas GEO project. This report "Analysis of Geothermal Resources in Three Texas Counties" (October 2020) improves on previous mapping of the Texas resources for the counties of Crockett (West Texas), Jackson (central Gulf Coast) and Webb (South Texas). Through additional bottom-hole temperatures (BHT), the number of well sites increased from 532 to 5,410 in total for these counties. The improved methodology to calculate formation temperatures from 3.5 km (11,500 ft) to 10 km (32,800 ft) includes thermal conductivity values more closely related to the actual county geological formations, incorporated radiogenic heat production of formations, and the related mapped depth to basement. The results show deep temperatures as hotter than previously calculated, with temperatures of 150 degrees Celcius possible for Webb County between depths of 2.6 - 5.1 km, Jackson County between depths 3.0 - 5.4 km, and Crockett County between depths of 2.7 - 8.0 km.

10 km↗

Wellbore Stability and Mud Loss Management in Geothermal Drilling: Optimizing Mud Weight to Mitigate Tensile Wellbore Fracturing at The Geysers, California

As part of a U.S. Department of Energy (DOE) Geothermal Technologies Office-funded initiative, Geysers Power Company, LLC, a subsidiary of Calpine Corporation, has been working to enhance drilling performance at the world’s largest geothermal field, The Geysers, in northern California. In a recent drilling operation of the GDC-36 well, excessive mud losses were encountered, initially addressed through repeated but largely ineffective cement plugging. Ultimately, the most effective strategy was to drill blind through the loss zones, made feasible by the high rate of penetration (ROP) achieved with PDC bits, allowing significant progress before the mud tanks were depleted and water-sensitive argillic formation layers could collapse. In response to these challenges, the project team explored alternative methods to minimize downtime and risks associated with cement plugging and continuous mud loss and to contemplate the driving mechanisms for the losses. Wellbore imaging using Formation MicroImager (FMI) and Ultrasonic Borehole Imager (UBI) tools revealed longitudinal tensile fractures, which were attributed to mud weights exceeding the minimum circumferential stress resulting from the native stress field and formation pressure. This study examines the mud losses encountered and leverages wellbore imaging data to understand the mechanisms behind mud induced tensile fracturing in specific rock facies. Understanding fracture behavior across different lithologies is crucial, as fractures within the reservoir can enhance steam migration throughout the system. The reservoir at The Geysers lies within the Mesozoic Franciscan Assemblage, a tectonic mélange formed by subduction. It consists of metamorphosed turbidite sandstone (greywacke) and mudstone (argillite), oceanic upper crust (including greenstone and chert), and serpentinized ultramafic rocks - each exhibiting distinct geomechanical fracturing properties. The structural fabric of the Franciscan Assemblage was shaped by low-angle Mesozoic thrust faulting and later overprinted by sub-vertical strike-slip structures related to the Pacific-North American plate boundary. A wellbore stability model was developed using core measurements and logs to simulate fracturing scenarios during drilling under varying stress conditions. These simulations guided the development of an optimized mud weight management strategy that should enable adaptive adjustments during drilling, reducing the likelihood of tensile fracturing and mud losses, ultimately improving operational efficiency.

15 GEOTHERMAL ENERGY↗

Deep Direct-Use Feasibility Study Numerical Modeling and Uncertainty Analysis using iTOUGH2 for West Virginia University

To reduce the geothermal exploration risk, a feasibility study is performed for a deep direct-use system proposed at the West Virginia University (WVU) Morgantown campus. This study applies numerical simulations to investigate reservoir impedance and thermal production. Because of the great depth of the geothermal reservoir, few data are available to characterize reservoir features and properties. As a result, the study focuses on the following three aspects: 1. model choice for predicting reservoir impedance and thermal breakthrough: after investigating three potential models (one single permeability model and two dual permeability models) for flow through fractured rock, it is decided to use single permeability model for further analysis; 2. well placement (horizontal vs. vertical) options: horizontal well placement seems to be more robust to heterogeneity and the impedance is more acceptable; 3. Prediction uncertainty: the most influential parameters are identified using a First-Order-Second-Moment uncertainty propagation analysis, and the uncertain range of the model predictions is estimated by performing a Monte Carlo simulation. Heterogeneity has a large impact on the perdition, therefore, is considered in the predictive model and uncertainty analysis. The numerical model results and uncertainty analysis are used for economic analysis. The dataset submitted here support the described study. Manuscript is submitted to Geothermics, will be linked once paper is accepted.

15 GEOTHERMAL ENERGY↗

"Hidden" hydrothermal technical potential & technoeconomics: Revealing permeability & fluids with more data

Historical hydrothermal estimates have largely relied on temperature or heat flow estimates ignoring the need for natural flowing fluids. More accurate hydrothermal estimates require some indication of permeability and fluids that naturally exist in the subsurface. This paper describes a novel approach that includes proxies of permeability and fluids in hydrothermal estimates by leveraging the relatively data-rich Great Basin. Specifically, nameplate capacities (megawatts) of operating geothermal plants, negative (0 megawatt) locations and 48 geophysical and geologic features are used to used in eXtreme Gradient Boosting (XGBoost) regression to make hydrothermal capacity predictions. Additionally, this work inputs the XGBoost-based hydrothermal predictions into the Renewable Energy Potential (reV) model to quantify technical capacity, its uncertainty and techno-economics. Compared to historical hydrothermal estimates, these predictions adhere to the 37 operating geothermal plants and negative locations. We present a method for subsampling the negative sites to bring the labels into balance that uses the geologic domain knowledge to proportionally represent negatives. Overall, the distributions of the hydrothermal technical capacity and the site levelized cost of energy are respectively much tighter, lower and more accurate than the previous estimates for the Great Basin, as they include geological and geophysical surrogates for permeability and fluids. Percentile (50th and 90th, median and high estimate, respectively) models provide bookends for these metrics.

13 HYDRO ENERGY↗

Reservoir Thermal Energy Storage Benchmarking (Rev. 3)

A benchmarking analysis of RTES research funded by GTO through the Beyond Batteries projects was conducted against the ESGC to see where they fit within the identified ESGC Use Cases. The projects were found to advance knowledge in multiple ESGC use cases, either directly or in some cases, indirectly as enabling technologies. This analysis is helpful to understand where RTES and associated research fits into the larger discussion around energy storage technologies. Also, a retrospective analysis of the Beyond Batteries projects was conducted to evaluate what the projects learned and how the results can be applied to advance the value of RTES. Major results of each of the studies are summarized in Table 2. Additionally, a comparative metrics analysis for RTES was completed to understand where RTES lies within the energy storage industry. Metrics for evaluation of RTES and its comparison to other storage technologies were selected and ranges of their values compiled. The selected metrics – LCOE (levelized cost of energy), capital costs, roundtrip efficiency, energy storage capacity, and storage time – were chosen based on data availability and have a particularly strong influence on the potential deployment of a storage technology. Charts which compare the metrics are presented in section 4.3 and show ranges for each of the 10 selected technologies. However, due to a lack of domestic operational facilities, values for RTES and for portions of the remaining technologies are based on theoretical modeling and studies of best-case scenarios. LCOE estimates for RTES fall within the lower reaches of Figure 15, but nevertheless amount to 2 – 5 times the ESGC Roadmap goal for LCOE, for example in the Facilitating and Evolving Grid Use Case. Capital costs for RTES sit on the higher end (Figure 16) but are expected to decrease as new projects are developed and the technology is refined. The theoretical roundtrip efficiency reported for RTES varies from mid to high percentages (Figure 17) with efficiencies upwards of 93% in modeled scenarios in the Portland Basin (Bershaw et al.,2020). RTES is also expected to have the largest energy storage capacities and longest storage times, likely matched only by lower efficiency hydrogen storage. To better assess the role that RTES could play in energy storage we examined it’s potential in the U.S. The potential depends on many factors. Recently, many researchers have started looking at deep sedimentary basins, depleted oil and gas fields, and basalt formations as potential targets for RTES development. The United States Geological Survey (USGS) has analyzed various cities and shown substantial RTES potential in the cooling sector (Pepin et al., 2021). By modeling RTES in low-quality groundwater (e.g., brackish), it is shown to be favorable across the U.S. with particular suitability in the Illinois Basin, Coastal Plains, and Basin and Range regions. Seasonal RTES operations have also been modeled in the Portland Basin by those at the USGS and Portland State University to simulate an RTES system supplying heating loads needed for the Oregon Health and Science University. Simulations suggest that high conductive heat loss in the initial years exists but tends to decrease with increasing time and development of the resource due to self-insulating nature of the basalts (Burns et al., 2020). Other national laboratory efforts are taking a close look at many of the technical issues involved with RTES (McLing et al., 2019, McLing et al., 2022). These include difficulties in understanding geochemical, hydrogeological, mechanical, and microbiological changes at such elevated temperatures and operational scenarios. Major gaps in research are identified and suggested for future work. With this increased focus to understand how to make RTES successful in the U.S., this technology could be a potential solution to many of the nation’s energy storage problems. For the energy independence of this country, the DOE should prioritize de-risking this technology by making future investments in pilot-scale demonstrations to attract potential investors.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗