Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Experiments on active control of vibrational power flow using piezoceramic actuators and sensors

The active control of flexural power flow in both semiinfinite and finite elastic beams is experimentally investigated. The experimental results demonstrate that piezoceramic transducers when used in conjunction with an adaptive least mean squares controller, can effectively control flexural power flow in thin beam systems. The piezoceramic transducers offer distinct size and weight advantages over conventional transducers. The experiments also demonstrate the use of an axial scanning laser vibrometer to determine out of plane velocity and power flow.

Gibbs, Gary P.↗

Thin film deployable reflector model for ET gamma ray imaging telescope system (ET-GRITS)

The Marshall Space Flight Center is developing a thin film reflector for a Gamma Ray Imaging Telescope System (GRITS) using the Shuttle External Tank (ET). The concept is to install an inflatable reflector in the ET that could be transferred from the orbiter in orbit. This is a study of a scale model reflector for the ET GRITS application. The approach is to form 1/2 mil film into a spherical mirror mounted on a seven-foot diameter metal ring. The ring mount is sealed and slightly evacuated to pressurize the film into shape. Several different fabrication techniques were investigated using seamed gore designs to form the reflector. Also studied was casting a film into a seamless circular sheet. The goal for this model was to achieve a one milliradian (rms) surface curvature error over 90 percent of the reflector area. This curvature was measured by a laser scanning instrument. The results show how different reflector designs and fabrication techniques contribute to surface curvature and focusing errors.

Huegele, Vinson B.↗

Velocity measurements in a hydrogen arcjet using LIF

A new diagnostic developed to measure the axial velocity of atomic hydrogen in a 1-kW hydrogen-fueled arcjet thruster is reported. The technique is based on laser-induced fluorescence of the Balmer alpha transition (656 nm) in atomic hydrogen. A narrow-band CW ring dye laser scans the excitation spectrum permitting accurate determination of the absorption line shape and position. The velocity is derived from the Doppler-shifted line position. A spatially resolved velocity profile is presented with a peak velocity of 12.8 km/s at the arcjet centerline near the exit plane.

Liebeskind, John G.↗

Laser-induced fluorescence of atomic hydrogen in an arcjet thruster

A diagnostic has been developed to measure gas kinetic temperature and velocity in a 1 kW hydrogen fueled arcjet thruster. The technique is based on laser-induced fluorescence of the Balmer alpha transition (656 nm) in atomic hydrogen. A narrowband CW ring dye laser scans the excitation spectrum, permitting accurate determination of the atomic line shape and position. The velocity is inferred from the Doppler shift of the transition while the temperature is obtained from the shape. Near the exit plane, measured axial velocity varies between 4 and 14 km/s; measured radial velocity varies from 0 to 4 km/s. Temperatures were measured in the range from 1000 K near the edge of the plume to 5000 K at the centerline. Relevant broadening mechanisms are discussed.

Liebeskind, John G.↗

Active isolation of vibrations with adaptive structures

Vibration transmission in structures is controlled by means of a technique which employs distributed arrays of piezoelectric transducers bonded to the supporting structure. Distributed PVDF piezoelectric strips are employed as error sensors, and a two-channel feedforward adaptive LMS algorithm is used for minimizing error signals and thereby controlling the structure. A harmonic force input excites a thick plate, and a receiving plate is configured with three pairs of piezoelectric actuators. Modal analyses are performed to determine the resonant frequencies of the system, and a scanning laser vibrometer is used to study the shape of the response of the receiving plate during excitation with and without the control algorithm. Efficient active isolation of the vibrations is achieved with modal suppression, and good control is noted in the on-resonance cases in which increased numbers of PVDF sensors and piezoelectric actuators are employed.

Guigou, C.↗

More About Laser Scanner Tests For Single-Event Upsets

Two reports describe preliminary theoretical and experimental studies based on method described in "Laser Scanner Tests For Single-Event Upsets" (NPO-18216). Laser-scan and heavy-ion data found correlated within factor of two. Method of testing for single-event upsets intended to overcome disadvantages of, complement, and/or substitute for more-expensive cyclotron-testing method, which does not provide spatial resolution.

Kim, Quiesup↗

Localization of extracellular matrix components in developing mouse salivary glands by confocal microscopy

The importance of the extracellular matrix (ECM) in epithelial-mesenchymal interactions in developing organisms is well established. Proteoglycans and interstitial collagens are required for the growth, morphogenesis, and differentiation of epithelial organs and the distribution of these molecules has been described. However, much less is known about other ECM macromolecules in developing epithelial organs. We used confocal microscopy to examine the distribution of laminin, heparan sulfate (BM-1) proteoglycan, fibronectin, and collagen types I, IV, and V, in mouse embryonic salivary glands. Organ rudiments were isolated from gestational day 13 mouse embryos and cultured for 24, 48, or 72 hours. Whole mounts were stained by indirect immunofluorescence and then examined using a Zeiss Laser Scan Microscope. We found that each ECM component examined had a distinct distribution and that the distribution of some molecules varied with culture time. Laminin was mainly restricted to the basement membrane. BM-1 proteoglycan was concentrated in the basement membrane and also formed a fine network throughout the mesenchyme. Type IV collagen was mainly located in the basement membrane of the epithelium, but it was also present throughout the mesenchyme. Type V collagen was distributed throughout the mesenchyme at 24 hours, but at 48 hours was principally located in the basement membrane. Type I collagen was distributed throughout the mesenchyme at all culture times, and accumulated in the clefts and particularly at the epithelial-mesenchymal interface as time in culture increased. Fibronectin was observed throughout the mesenchyme at all times.

Hardman, P.↗

Making Ceramic Reference Specimens Containing Seeded Voids

Internal and surface voids of known sizes incorporated into silicon carbide and silicon nitride ceramic reference specimens at prescribed locations. Specimens used to demonstrate sensitivity and resolution in nondestructive examination techniques like scanning laser acoustic microscopy and x-radiography, and to assist in establishing proper examination procedures.

Baaklini, George Y.↗

Acoustic fatigue characterization of carbon/carbon panels

Data from a sonic fatigue test of a blade-stiffened carbon/carbon panel is analyzed to determine the progression of damage to failure. The reduction in stiffness, as observed from acceleration measurements taken during the test, is correlated with the physical damage. Damage was measured through visual inspection, thermographic measurements, and through the novel use of vibration data collected using a scanning laser vibrometer.

Rizzi, S. A.↗

Centroid Detector Assembly for the AXAF-I Alignment Test System

The High Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility (imaging) (AXAF-I) consists of four nested paraboloids and four nested hyperboloids, all of meter-class size, and all of which are to be assembled and aligned in a special 15 meter tower at Eastman Kodak Company in Rochester, NY. The goals of the alignment are (1) to make the images of the four telescopes coincident; (2) to remove coma from each image individually; and (3) to control and determine the final position of the composite focus. This will be accomplished by the HRMA Aligment Test System (HATS) which is essentially a scanning Hartmann test system. The scanning laser source and the focal plane of the HATS are part of the Centroid Detector Assembly (CDA) which also includes processing electronics and software. In this paper we discuss the design and the measured performance of the CDA.

Glenn, Paul↗

Technology

In this session, Session WP3, the discussion focuses on the following topics: Monitoring Physiological Variables With Membrane Probes; Real Time Confocal Laser Scanning Microscopy, Potential Applications in Space Medicine and Cell Biology; Optimum Versus Universal Planetary and Interplanetary Habitats; Application of Remote Sensing and Geographic Information System Technologies to the Prevention of Diarrheal Diseases in Nigeria; A Small G Loading Human Centrifuge for Space Station ERA; Use of the Bicycle Ergometer on the International Space Station and Its Influence On The Microgravity Environment; Munich Space Chair (MSC) - A Next Generation Body Restraint System for Astronauts; and Thermoelectric Human-Body Cooling Units Used By NASA Space Shuttle Astronauts.

Source record↗

Recovery of motion parameters from distortions in scanned images

Scanned images, such as those produced by the scanning-laser ophthalmoscope (SLO), show distortions when there is target motion. This is because pixels corresponding to different image regions are acquired sequentially, and so, in essence, are slices of different snapshots. While these distortions create problems for image registration algorithms, they are potentially useful for recovering target motion parameters at temporal frequencies above the frame rate. Stetter, Sendtner and Timberlake measured large distortions in SLO images to recover the time course of rapid horizontal saccadic eye movements. Here, this work is extended with the goal of automatically recovering small eye movements in two dimensions. Eye position during the frame interval is modeled using a low dimensional parametric description, which in turn is used to generate predicted distortions of a reference template. The input image is then registered to the distorted template using normalized cross correlation. The motion parameters are then varied, and the correlation recomputed, to find the motion which maximizes the peak value of the correlation. The location and value of the correlation maximum are determined with sub-pixel precision using biquadratic interpolation, yielding eye position resolution better than 1 arc minute. This method of motion parameter estimation is tested using actual SLO images as well as simulated images. Motion parameter estimation might also be applied to individual video lines in order to reduce pipeline delays for a near real-time system.

Mulligan, Jeffrey B.↗

Effects of JP-8 Jet Fuel on Homeostasis of Clone 9 Rat Liver Cells

Chronic exposure to JP-8 and other kerosene-based petroleum distillates has been associated with hepatic, renal, neurologic, pulmonary, and immune toxicity. However, the effects of kerosene-type jet fuels on cellular homeostasis hitherto have not been reported. Fluorescence imaging using a Meridian Ultima laser scanning fluorescence microscope was used to evaluate the effect of JP-8 jet fuel on a communication competent rat liver cell line. Several endpoints of cellular function were measured including gap junctional intercellular communication (GJIC), mitochondrial and plasma membrane potential (MMP and PMP, respectively), intracellular glutathione (GSH) concentration, glutathione-S-transferase (GST) activity, and reactive oxygen species (ROS) generation. Cells were treated with JP-8 (0.01 to 2% in ethanol (EtOH)) for the following time points: 1 h, 24 h, 48 h, and analysis immediately after addition of jet fuel. GJIC analyzed directly after addition of 1% JP-8 was reduced 4.9-fold relative to EtOH-dosed control groups and further reduction (12.6-fold) was observed in cells treated for 1 h. Moreover, GJIC was not recoverable in cells treated with 1% JP-8 for 1 h and subsequently washed and incubated in fresh medium for 1 h. Significant changes in GSH content and GST activity were observed in cells analyzed directly after addition of 1% JP-8. GSH content increased in cells treated for 1 h with less than 2% JP-8 whereas treatment with 2% JP-8 for 1 h resulted in a 50% reduction in intracellular GSH relative to EtOH-dosed controls. Cells treated with 1% JP-8 for 48 h exhibited changes in GSH levels. However, higher JP-8 concentrations exhibited more pronounced changes in GSH and GST, which led to suppression of GSH synthesis. ROS increased in a dose-responsive fashion at JP-8 concentrations up to 1%, but decreased to 80% of control values at 2% and 3% JP-8. A 25% reduction in PMP was observed in cells treated for 1 h with 1% JP-8. In contrast, cells treated for 48 h with 2% JP-8 exhibited a 25% increase when compared to control. No significant changes were noted in the 0.01 and 1% treatment groups. Moreover, no significant changes were observed in MMP or intracellular calcium concentrations in cells treated with 0.01 to 2% JP-8 for up to 48 h. In summary, the most significant effects observed in the present study which may contribute to the toxicity of JP-8 jet fuel in cultured rat liver cells include effects on GJIC, ROS production, and GSH depletion at high (i.e., greater than 2%) JP-8 concentrations.

Wilson, C. L.↗

Time Resolved 3-D Mapping of Atmospheric Aerosols and Clouds During the Recent ARM Water Vapor IOP

The HARLIE lidar was deployed at the ARM SGP site in north central Oklahoma and recorded over 100 hours of data on 16 days between 17 September and 6 October 2000 during the recent Water Vapor Intensive Operating Period (IOP). Placed in a ground-based trailer for upward looking scanning measurements of clouds and aerosols, HARLIE provided a unique record of time-resolved atmospheric backscatter at 1 micron wavelength. The conical scanning lidar images atmospheric backscatter along the surface of an inverted 90 degree (full angle) cone up to an altitude of 20 km. 360 degree scans having spatial resolutions of 20 meters in the vertical and 1 degree in azimuth were obtained every 36 seconds. Various boundary layer and cloud parameters are derived from the lidar data, as well as atmospheric wind vectors where there is Sufficiently resolved structure that can be traced moving through the surface described by the scanning laser beam. Comparison of HARLIE measured winds with radiosonde measured winds validates the accuracy of this new technique for remotely measuring atmospheric winds without Doppler information.

Schwemmer, Geary↗

Binaural Simulation Experiments in the NASA Langley Structural Acoustics Loads and Transmission Facility

A location and positioning system was developed and implemented in the anechoic chamber of the Structural Acoustics Loads and Transmission (SALT) facility to accurately determine the coordinates of points in three-dimensional space. Transfer functions were measured between a shaker source at two different panel locations and the vibrational response distributed over the panel surface using a scanning laser vibrometer. The binaural simulation test matrix included test runs for several locations of the measuring microphones, various attitudes of the mannequin, two locations of the shaker excitation and three different shaker inputs including pulse, broadband random, and pseudo-random. Transfer functions, auto spectra, and coherence functions were acquired for the pseudo-random excitation. Time histories were acquired for the pulse and broadband random input to the shaker. The tests were repeated with a reflective surface installed. Binary data files were converted to universal format and archived on compact disk.

Grosveld, Ferdinand W.↗

Using Dual-wavelength Fiber Bragg Gratings for Temperature and Strain Sensing at Cryogenic Temperature

By using dual-wavelength fiber-optic Bragg gratings, a new technique has been developed for sensing both temperature and strain simultaneously in cryogenic temperature range. Two Bragg gratings with different wavelengths were inscribed at the same location in an optical fiber to form a dual-wavelength sensor. By measuring the wavelength shifts that resulted from the fiber being subjected to different temperatures and strains, the wavelength-dependent thermo-optic coefficients and photoelastic coefficients of the fiber were determined. These coefficients were used to construct the elements of the K matrix, which enables to determine inversely the strain and temperature changes by measuring the wavelength shifts of the dual-wavelength Bragg grating. In this study, measurements were made over the temperature range from room temperature down to about 10 K, addressing much of the low temperature range of cryogenic tanks. A structure transition of the optical fiber during the temperature change was found from about 70 K to 140 K. This transition caused splitting of the waveforms characterizing the Bragg gratings, and the determination of wavelength shifts was consequently complicated. Several alternatives are proposed to resolve this problem. The effectiveness and sensitivities of these measurements in different temperature ranges are discussed. The separation of two wavelengths for the dual-wavelength Bragg grating has been widened to increase the sensitivities of measurement; however, this separation can still be covered in the scanning range from single scanning laser.

Wu, Meng-Chou↗

The Application of Lidar to Synthetic Vision System Integrity

One goal in the development of a Synthetic Vision System (SVS) is to create a system that can be certified by the Federal Aviation Administration (FAA) for use at various flight criticality levels. As part of NASA s Aviation Safety Program, Ohio University and NASA Langley have been involved in the research and development of real-time terrain database integrity monitors for SVS. Integrity monitors based on a consistency check with onboard sensors may be required if the inherent terrain database integrity is not sufficient for a particular operation. Sensors such as the radar altimeter and weather radar, which are available on most commercial aircraft, are currently being investigated for use in a real-time terrain database integrity monitor. This paper introduces the concept of using a Light Detection And Ranging (LiDAR) sensor as part of a real-time terrain database integrity monitor. A LiDAR system consists of a scanning laser ranger, an inertial measurement unit (IMU), and a Global Positioning System (GPS) receiver. Information from these three sensors can be combined to generate synthesized terrain models (profiles), which can then be compared to the stored SVS terrain model. This paper discusses an initial performance evaluation of the LiDAR-based terrain database integrity monitor using LiDAR data collected over Reno, Nevada. The paper will address the consistency checking mechanism and test statistic, sensitivity to position errors, and a comparison of the LiDAR-based integrity monitor to a radar altimeter-based integrity monitor.

Campbell, Jacob L.↗

Quenching Combustible Dust Mixtures Using Electric Particulate Suspensions (EPS): A New Testing Method For Microgravity

The Electric Particulate Suspension (EPS) is a combustion ignition system being developed at Iowa State University for evaluating quenching effects of powders in microgravity (quenching distance, ignition energy, flammability limits). Because of the high cloud uniformity possible and its simplicity, the EPS method has potential for "benchmark" design of quenching flames that would provide NASA and the scientific community with a new fire standard. Microgravity is expected to increase suspension uniformity even further and extend combustion testing to higher concentrations (rich fuel limit) than is possible at normal gravity. Two new combustion parameters are being investigated with this new method: (1) the particle velocity distribution and (2) particle-oxidant slip velocity. Both walls and (inert) particles can be tested as quenching media. The EPS method supports combustion modeling by providing accurate measurement of flame-quenching distance as a parameter in laminar flame theory as it closely relates to characteristic flame thickness and flame structure. Because of its design simplicity, EPS is suitable for testing on the International Space Station (ISS). Laser scans showing stratification effects at 1-g have been studied for different materials, aluminum, glass, and copper. PTV/PIV and a leak hole sampling rig give particle velocity distribution with particle slip velocity evaluated using LDA. Sample quenching and ignition energy curves are given for aluminum powder. Testing is planned for the KC-135 and NASA s two second drop tower. Only 1-g ground-based data have been reported to date.

Colver, Gerald M.↗