At least 217 records · Page 12

Construction and testing of the 2.5m mass driver

Presented are the designs used in the construction of the 2.5 m mass driver and the results of the initial testing program. The mass driver consists of equal length sections of acceleration and deceleration each containing 59 drive coils of 13.1 cm caliber. Intermediate energy storage is provided by sector capacitors which are recharged every half cycle by an external power source. The drive coils are individually energized through SCR's with timing supplied by position sensing optical detectors. The drive consists of two phases which operate in quadrature. The initial bucket to be propelled through the mass driver contains two coils of aluminum wire chilled to liquid nitrogen temperatures to momentarily sustain superconducting field intensities. Magnetic flight is generated by eddy current repulsion from six copper guide strips lining the mass driver. Nominal acceleration is 5000 m/sec per sec giving a maximum bucket velocity of 112 m/s.

Snow, W. R.↗

Phototransistors Development and their Applications to Lidar

Custom-designed two-micron phototransistors have been developed using Liquid Phase Epitaxy (LPE), Molecular Beam Epitaxy (MBE) and Metal-Organic Chemical Vapor Deposition (MOCVD) techniques under Laser Risk Reduction Program (LRRP). The devices were characterized in the Detector Characterization Laboratory at NASA Langley Research Center. It appears that the performance of LPE- and MBE-grown phototransistors such as responsivity, noise-equivalent-power, and gain, are better than MOCVD-grown devices. Lidar tests have been conducted using LPE and MBE devices under the 2-micrometer CO2 Differential Absorption Lidar (DIAL) Instrument Incubator Program (IIP) at the National Center for Atmospheric Research (NCAR), Boulder, Colorado. The main focus of these tests was to examine the phototransistors performances as compared to commercial InGaAs avalanche photodiode by integrating them into the Raman-shifted Eye-safe Aerosol Lidar (REAL) operating at 1.543 micrometers. A simultaneous measurement of the atmospheric backscatter signals using the LPE phototransistors and the commercial APD demonstrated good agreement between these two devices. On the other hand, simultaneous detection of lidar backscatter signals using MBE-grown phototransistor and InGaAs APD, showed a general agreement between these two devices with a lower performance than LPE devices. These custom-built phototransistors were optimized for detection around 2-micrometer wavelength while the lidar tests were performed at 1.543 micrometers. Phototransistor operation at 2-micron will improve the performance of a lidar system operating at that wavelength. Measurements include detecting hard targets (Rocky Mountains), atmospheric structure consisting of cirrus clouds and boundary layer. These phototransistors may have potential for high sensitivity differential absorption lidar measurements of carbon dioxide and water vapor at 2.05-micrometers and 1.9-micrometers, respectively.

Abedin, M. N.↗

Operating Modes and Cooling Capabilities of the 3-Stage ADR Developed for the Soft-X-Ray Spectrometer Instrument on Astro-H

A 3-stage adiabatic demagnetization refrigerator (ADR) is used on the Soft X-ray Spectrometer instrument on Astro-H to cool a 6x6 array of x-ray microcalorimeters to 50 mK. The ADR is supported by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and cool radiation shields within the cryostat. The ADR is configured so that it can use either the liquid helium or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated into the flight dewar in early 2014, and have since been extensively characterized and calibrated. This paper summarizes the operation and performance of the ADR in all of its operating modes

x-ray astronomy↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Physics and Chemistry of Te and HgTe-based Ternary Melts

Historically, the theoretical treatment of the liquid phases has always been more difficult and complicated than that for solid and gas phases. A liquid has no lattice structure as crystalline solids and the atoms/molecules in the liquid can migrate through it relatively rapidly. On the other hand, it is also interacting with many other atoms/molecules so that the simplifications of the kinetic theory of gases cannot be employed. For more complicated liquids, such as the liquids of high ionicity and those containing hydrogen bonds and electric dipoles, the understanding is far from complete. At the same time, accurate information on the physics and chemistry of semiconductor melts is needed for the quantitative descriptions of the process of crystal growth from melt. The pre-crystallization phenomena in the liquid phase are critical because the properties of the grown crystals depend on the state and structure of the melt as well as the thermal history of the melt during solidification process. However, the data on the liquid phase, such as thermophysical properties of semiconductor melts are scarce, especially for the HgTe-based II-VI ternary compound semiconductors because of their high vapor pressure and extreme toxicity. Analysis of the thermophysical properties of the melt can provide information about structural transitions of the melt during the solidification process. From a broader point of view, the structure of liquids is much more complicated than the crystalline solids, especially the relaxation behavior through different thermal histories. The theory of hetero-phase fluctuations of liquids is applicable to any many-body systems including condensed-matter physics, field theory, physics of nuclear-matter, cosmology, biology and even sociology. This book summarizes the physics and chemistry from the experimental measurements and theoretical analyses of phase diagram, thermodynamic properties, density, thermal conductivity, viscosity, and electrical conductivity on the binary, pseudo-binary and ternary melts of the most advanced IR-detector material systems of HgCdTe and HgZnTe as well as the analyses of these results. The main objectives of this study are: (1) to provide the phase diagrams and thermodynamic properties of Hg-Cd-Te and Hg-Zn-Te systems through quantitatively fitting the experimental data by assuming an associated solution model for the liquid phase, (2) to experimentally measure the thermophysical properties of the Hg-Cd-Te and Hg-Zn-Te melts, including density, viscosity, electrical conductivity and thermal conductivity as functions of temperature and composition and (3) to enhance the fundamental knowledge of hetero-phase fluctuations and relaxation phenomena in the melts and extend our understanding of the solidification process in order to interpret the experimental results of crystal growth so as to improve the melt growth processes of the compound semiconductor. The physics and chemistry of Te and HgTe-based ternary melts were explored through the studies of the structural transformation during melting, the supercooling during solidification, the relaxation phenomena after rapid cooling of the melts and the metal-semiconductor transition in the melts through the analyses of electrical conductivity and Lorenz number. An in-depth study on the thermophysical properties and their time-dependent structural dynamic processes taking place in the vicinity of the solid-liquid phase transition of the narrow homogeneity range HgTe-based ternary semiconductors as well as the analysis of the homogenization process in the melt will also be presented.

Thermophysical properties↗

An FIR cooled grating spectrometer for the Kuiper Airborne Observatory

The design and performance of a liquid-He-cooled spectrometer being developed for the Kuiper Airborne Observatory (KAO) to study FIR lines originating in the interstellar medium are discussed. Currently, the spectrometer contains six Ge:Ga photoconductor detectors mounted in integrating cavities and cooled to about 3 K; the collimator focal plane has space for 39 such detectors. The instrument achieves a maximum resolving power of 6000 by means of a 45-cm long echelle grating and is optically capable of operating in the spectral range 25-300 microns. A laboratory spectrum of water vapor, an atmospheric water absorption feature measured from the KAO with Mars as a source, and the forbidden O(2+) emission from W51-IRS1 are shown.

Erickson, E. F.↗

Hanging drop crystal growth apparatus

This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

Naumann, Robert J.↗

X-Ray Diffraction on Mars: Scientific Discoveries Made by the CheMin Instrument

The Mars Science Laboratory Curiosity landed in Gale crater in August 2012 with the goal to identify and characterize habitable environments on Mars. Curiosity has been studying a series of sedimentary rocks primarily deposited in fluviolacustrine environments approximately 3.5 Ga. Minerals in the rocks and soils on Mars can help place further constraints on these ancient aqueous environments, including pH, salinity, and relative duration of liquid water. The Chemistry and Mineralogy (CheMin) X-ray diffraction and X-ray fluorescence instrument on Curiosity uses a Co X-ray source and charge-coupled device detector in transmission geometry to collect 2D Debye-Scherrer ring patterns of the less than 150 micron size fraction of drilled rock powders or scooped sediments. With an angular range of approximately 2.52deg 20 and a 20 resolution of approximately 0.3deg, mineral abundances can be quantified with a detection limit of approximately 1-2 wt. %. CheMin has returned quantitative mineral abundances from 16 mudstone, sandstone, and aeolian sand samples so far. The mineralogy of these samples is incredibly diverse, suggesting a variety of depositional and diagenetic environments and different source regions for the sediments. Results from CheMin have been essential for reconstructing the geologic history of Gale crater and addressing the question of habitability on ancient Mars.

Rampe, E. B.↗

FOSSIL—Finding Our Cosmic Roots

FOSSIL (Fragments from the Origins of the Solar System and our Interstellar Locale) is a concept to explore the largest solar system object visible to the unaided eye—the zodiacal cloud. The cloud’s many dust particles are each a tiny time capsule from a comet or asteroid. The FOSSIL concept is for the in situ compositional analysis of interplanetary dust particles, and also of the particles passing through the solar system from interstellar space. By measuring the zodiacal and interstellar particles’ velocity vectors and compositions, the approach resolves fundamental questions about the solar system’s origins. The FOSSIL concept is to: (1) Discover whether today’s local interstellar dust matches the composition of the feedstock from which the solar system formed; (2) Determine whether comets’ fine-grained component preserves unprocessed pre-solar dust or shows signs of processing in the early solar system; and (3) Learn whether comets’ and asteroids’ organic material share a common source or formed from distinct reservoirs. The FOSSIL concept is based on the use of a Dust Telescope (DT) with the capability to measure the composition and the velocity vector of dust particles to unambiguously separate interstellar from interplanetary particles, and identify a subset of zodiacal particles that are exclusively cometary. In the DT, particles pass through the trajectory sensor unharmed and impact a target plate, where they are vaporized and partially ionized. The ions are electrostatically focused onto a detector where the time-of-flight mass spectrum is recorded, enabling measurement of the composition of the interstellar solids, detection of cometary minerals altered by high temperatures or exposure to liquid water in the early solar system, and the characterization of the organic materials from the comets and asteroids that are still being delivered to the Earth today. FOSSIL’s objectives crosscut several disciplines with planetary science. Astrophysics interests lie in understanding interstellar solar matter and the only debris disk accessible in situ. Heliophysics interest is in the verification of large-scale heliospheric magnetic field models by the measured effect on the motion of electrically charged interstellar dust. Reporting the makeup of interplanetary dust that ablates in our atmosphere is valuable to Earth sciences. FOSSIL’s DT is scalable and can be accommodated to a variety of mission opportunities, without restriction on launch dates, and for a large number of possible orbits.

Turner, Neal↗

Ccds: Their Cause and Cure

Charge coupled devices (CCDs) have opened new horizons in the optical astronomy. Most of the presently existing astronomical CCD systems are oriented and designed primarily for work on faint objects. The use of CCDs for high precision work on bright objects remains to be explored. Issues and problems specific to (CCDs) are covered in detail. The important structural characteristics of CCDs are that they are integrating, self scanned, photon counting (one selection for each detected photon), solid state devices. The typical physical sizes are of the order of 1 - 3 cm, and typical raster formats of 500x500 pixels (TI), 320x512 (RCA), 385x576 (GEC), 800x800 (TI), and 1500x1500 (GEC) should be available soon. Typical (and optimal) operating temperatures are around -100 C, with liquid N2 as the most common coolant. Some CCDs are physically warped. This causes focus variations across the surface, which amount to a spatially variable PSF. Other relevant properties of CCDs as detectors and a comparison with some other astronomical detectors are given.

Djorgovski, S.↗

He II Liquid/Vapor Phase Separator for Large Dynamic Range Operation

A phase separator, which separates helium vapor from liquid superfluid helium (He II), is an indispensable device for space cryogenics. The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which only the detector package is cold at launch, the remainder of the telescope being subsequently cooled to operating temperature on orbit. Therefore, a large dynamic operational range is required of the cryogen system. This is a report of initial laboratory test results with candidate porous plugs as phase separators. Mass flow rates and pressure and temperature differences across a porous plug were measured in this experiment. Relatively large mass flow rates were observed even at small pressure differences. In the high mass flow rate region, a hysteresis was observed with increases and decreases of the pressure difference. A linear theory is proposed and compared with experimental data to explain several phenomena observed in this system.

Phase Separator, Space Cryogenics↗

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management↗

Advanced methods for preparation and characterization of infrared detector materials

Differential thermal analysis data were obtained on mercury cadmium telluride alloys in order to establish the liquidus temperatures for the various alloy compositions. Preliminary theoretical analyses was performed to establish the ternary phase equilibrium parameters for the metal rich region of the phase diagram. Liquid-solid equilibrium parameters were determined for the pseudobinary alloy system. Phase equilibrium was calculated and Hg(l-x) Cd(x) Te alloys were directionally solidified from pseudobinary melts. Electrical resistivity and Hall coefficient measurements were obtained.

Lehoczky, S. L.↗

Thermal emission spectroscopy of the middle atmosphere

The general objective of this research is to obtain, via remote sensing, simultaneous measurements of the vertical distributions of stratospheric temperature, ozone, and trace constituents that participate in the catalytic destruction of ozone (NO(sub y): NO, NO2, NO3, HNO3, ClONO2, N2O5, HNO4; Cl(sub x): HOCl), and the source gases for the catalytic cycles (H2O, CH4, N2O, CF2Cl2, CFCl3, CCl4, CH3Cl, CHF2Cl, etc.). Data are collected during a complete diurnal cycle in order to test our present understanding of ozone chemistry and its associate catalytic cycles. The instrumentation employed is an emission-mode, balloon-borne, liquid-nitrogen-cooled Michelson interferometer-spectrometer (SIRIS), covering the mid-infrared range with a spectral resolution of 0.020 cm(exp -1). Cryogenic cooling combined with the use of extrinsic silicon photoconductor detectors allows the detection of weak emission features of stratospheric gaseous species. Vertical distributions of these species are inferred from scans of the thermal emission of the limb in a sequence of elevation angles. The fourth SIRIS balloon flight was carried out from Palestine, Texas on September 15-16, 1986 with 9 hours of nighttime data (40 km). High quality data with spectral resolution 0.022 cm(exp -1), were obtained for numerous limb sequences. Fifteen stratospheric species have been identified to date from this flight: five species from the NO(sub y) family (HNO3, NO2, NO, ClONO2, N2O5), plus CO2, O3, H2O, N2O, CH4, CCl3F, CCl2F2, CHF2Cl, CF4, and CCl4. The nighttime values of N2O5, ClONO2, and total odd nitrogen have been measured for the first time, and compared to model results. Analysis of the diurnal variation of N2O5 within the 1984 and 1986 data sets, and of the 1984 ClONO2 measurements, were presented in the literature. The demonstrated ability of SIRIS to measure all the major NO(sub y) species, and therefore to determine the partitioning of the nitrogen family over a continuous diurnal cycle, is a powerful tool in the verification and improvement of photochemical modeling.

Kunde, V. G.↗

Methods of use for sensor based fluid detection devices

Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

Lewis, Nathan S.↗

Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

x-ray irradiation↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Four-color infrared bolometer system for one-meter telescope

A far-infrared photometer has been developed as a focal plane instrument for a balloon-borne 102-cm telescope. The four gallium-doped Ge bolometers adopted for the system operate at 1.8 K in a liquid-helium dewar. Wavelength bands of the four-bolometer system are a narrow spectrum between 18 and 22 microns, and bands centered at 42, 70, and 140 microns. The responsivity and Johnson noise of the detectors limit the performance of the instrument.

Daneu, V.↗