Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of thermal fracture limits of gas-cooled Nd:APG-1 and Tm:YLF slabs

High-energy short-pulse laser systems demonstrated to date have been limited to low repetition rates due to significant thermal management challenges associated with scaling these systems to high average power, including the need to understand the thermal fracture limits of laser gain media. In this paper, we demonstrate the thermal fracture limits of two high-average-power gain media in a realistic diode-pumped amplifier geometry: a 5 mm thick Nd:APG-1 slab and a 2 mm thick Tm:YLF slab, both cooled by room-temperature helium gas. Finite element analysis revealed maximum tensile stress at fracture of 25 ± 3 MPa for Nd:APG-1 and 30 ± 3 MPa for Tm:YLF. These stress levels correspond to average volumetric heat loads of 13 ± 1 W/cm 3 in Nd:APG-1 and 247 ± 12 W/cm 3 in Tm:YLF. Additional simulations show geometric scaling: thinner slabs tolerate higher heat loads before fracture, while larger pump spots reach the fracture stress at lower heat loads.

Lasers↗

Spallation Neutron Source Proton Power Upgrade (PPU) Project: Lessons Learned for CD-4

The SNS PPU project goals were to design, build, install and test the equipment necessary to double the accelerator power from 1.4 MW to 2.8 MW and to deliver a 2.0 MW qualified target. PPU also included the provision of a stub-out in the SNS accumulator-ring-to-target tunnel to facilitate a rapid connection to a new proton beamline for the Second Target Station (STS) project. The power capability was doubled by increasing the proton beam energy by 33% and the peak beam current by 50%, relative to pre-PPU accelerator performance. The project also included modifications to some buildings and services. The PPU project accomplished the energy upgrade by fabricating and installing new superconducting radiofrequency (RF) cryomodules, with supporting RF equipment, in the existing linac tunnel and klystron gallery, respectively. The High Voltage Converter Modulators (HVCM) and klystrons for some of the existing installed RF equipment were upgraded to handle the higher beam current. The increased beam power of 2 MW on the First Target Station (FTS) was enabled by the addition of a new high-volume gas injection system for pressure pulse and cavitation mitigation in the mercury target and a redesigned mercury target vessel.

43 PARTICLE ACCELERATORS↗

Ultrafast Laser Material Damage Simulation—A New Look at an Old Problem

The chirped pulse amplification technique has enabled the generation of pulses of a few femtosecond duration with peak powers multi-Tera and Peta–Watt in the near infrared. Its implementation to realize even shorter pulse duration, higher energy, and higher repetition rate laser systems relies on overcoming the limitations imposed by laser damage of critical components. In particular, the laser damage of coatings in the amplifiers and in post-compression optics have become a bottleneck. The robustness of optical coatings is typically evaluated numerically through steady-state simulations of electric field enhancement in multilayer stacks. However, this approach cannot capture crucial characteristics of femtosecond laser induced damage (LID), as it only considers the geometry of the multilayer stack and the optical properties of the materials composing the stack. This approach neglects that in the interaction of an ultrashort pulse and the materials there is plasma generation and associated material modifications. Here, we present a numerical approach to estimate the LID threshold of dielectric multilayer coatings based on strong field electronic dynamics. In this dynamic scheme, the electric field propagation, photoionization, impact ionization, and electron heating are incorporated through a finite-difference time-domain algorithm. We applied our method to simulate the LID threshold of bulk fused silica, and of multilayer dielectric mirrors and gratings. The results are then compared with experimental measurements. The salient aspects of our model, such as the implementation of the Keldysh photoionization model, the impact ionization model, the electron collision model for ‘low’-temperature, dense plasma, and the LID threshold criterion for few-cycle pulses are discussed.

36 MATERIALS SCIENCE↗

Control Systems Design for STS Accelerator

The Second Target Station (STS) Project will expand the capabilities of the existing Spallation Neutron Source (SNS), with a suite of neutron instruments optimized for long wavelengths. A new accelerator transport line will be built to deliver one out of four SNS pulses to the new target station. The Integrated Control Systems (ICS) will provide remote control, monitoring, OPI, alarms, and archivers for the accelerator systems, such as magnets power supply, vacuum devices, and beam instrumentation. The ICS will upgrade the existing Linac LLRF controls to allow independent operation of the FTS and STS and support different power levels of the FTS and STS proton beam. The ICS accelerator controls are in the phase of preliminary design for the control systems of magnet power supply, vacuum, LLRF, Timing, Machine protection system (MPS), and computing and machine network. The accelerator control systems build upon the existing SNS Machine Control systems, use the SNS standard hardware and EPICS software, and take full advantage of the performance gains delivered by the PPU Project at SNS.

Yan, Jay↗

Mirrors for petawatt lasers: Design principles, limitations, and solutions

High intensity and high energy laser facilities place increasing demands on optical components, requiring large surface area optics with exacting specifications. Petawatt lasers are high energy, short-pulse laser systems generally based on chirped-pulse amplification, where an initial low energy short pulse is stretched, amplified, and then recompressed to produce fs to ps high-power laser pulses. In such petawatt lasers, the highest demands are placed on the final optics, including gratings which compress the pulses and mirrors which direct and focus the final high-power beams. The limiting factor in these optical components is generally laser-induced damage. Designing and fabricating these optical components to meet reflection, dispersion, and other requirements while meeting laser-induced damage requirements is the primary challenge discussed in this tutorial. We will introduce the reader to the technical challenges and tradeoffs required to produce mirrors for petawatt lasers and discuss current research directions.

47 OTHER INSTRUMENTATION↗

ARCS Replacement at TREAT for TRTR 2020 - Abstract

The Transient REActor Test (TREAT) facility was restarted in 2017 to perform reactor fuels testing under transient conditions, following shutdown in 1994 and 23 years in non-operational standby. TREAT is a transient reactor that, like most pulsing reactors, can create natural shaped power pulses. However, TREAT provides the ability to shape the power pulse and control the energy deposition rate on the test specimens by automatically controlling the amount of reactivity insertion over time. The original automatic reactor control system (ARCS) was created in the 1980s using INTEL 8086 CPU boards and software written in assembly code. The need to maintain the system for the next 40+ years of TREAT life led to the decision to replace ARCS with modern hardware while maintaining the original functionality. After a prototyping effort, the replacement was successfully completed in the first quarter of 2020. The process and results of that effort are reported here.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First DIII-D-West hybrid scenario similarity experiments for iter-relevant long-pulse operation

For the first time, similarity experiments between DIII-D and WEST were performed in the ITER "hybrid-like" regime during dedicated campaigns in April and May 2025. The matched parameters include elongation, triangularity, ion ∇B drift direction toward the X-point, qprofile, and core normalized physics quantities in terms of normalized pressure, normalized gyroradius, electron collisionality, ratio of ion to electron temperature, T i /T e . Core transport physics is explored with different aspect ratio (R/a) values (typically 3 at DIII-D and 5 on WEST). DIII-D explored high-beta conditions (electromagnetic effect) with low torque injection (~0 ± 0.5 N•m) using high heating power (up to 6 MW NBI and 2 MW ECRH powers), while scanning the heating mix (ion vs electron), beta, T i /T e , core radiation via controlled tungsten injection using the Laser Blow-Off system. WEST extended operation toward long-duration pulses using its actively cooled tungsten divertor, achieving dominated electron heating regimes with reduced tungsten contamination. Boron impurity injection were scanned on WEST to control edge conditions and core performance. It is found that core confinement improves-manifested by higher electron temperature, total energy content, neutron rate, and ion temperatureunder conditions of low separatrix density, consistent with previous observations [Bourdelle et al., Nucl. Fusion 63 (2023) 056021]. Conditions for Hmode access and for ion heating in electron-dominated regimes in both WEST and DIII-D will be discussed and compared. The ratio of the thermal energy confinement time (τ E ) to the volume-averaged electron-ion collisional heat exchange time (τ e-i ) is a key parameter to enhance ion heating and potentially facilitate H-mode access in electron-heated regimes. These first-of-a-kind coordinated DIII-D and WEST experiments provide a unique multi-machine dataset to validate predictive models and to optimize ITER hybrid-scenario performance under diverse core and edge conditions.

DIII-D↗

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

Toward high laser power beam manipulation with nanophotonic materials: evaluating thin film damage performance

Nanophotonic materials enable unprecedented control of light-matter interactions, including the ability to dynamically steer or shape wavefronts. Consequently, nanophotonic systems such as metasurfaces have been touted as promising candidates for free-space optical communications, directed energy and additive manufacturing, which currently rely on slow mechanical scanners or electro-optical components for beam steering and shaping. However, such applications necessitate the ability to support high laser irradiances (> kW/cm 2 ) and systematic studies on the high-power laser damage performance of nanophotonic materials and designs are sparse. Here, we experimentally investigate the pulsed laser-induced damage performance (at λ ∼ 1 µm) of model nanophotonic thin films including gold, indium tin oxide, and refractory materials such as titanium nitride and titanium oxynitride. We also model the spatio-thermal dissipation dynamics upon single-pulse illumination by anchoring experimental laser damage thresholds. Our findings show that gold exhibits the best laser damage resistance, but we argue that alternative materials such as transparent conducting oxides could be optimized to balance the tradeoff between damage resistance and optical tunability, which is critical for the design of thermally robust nanophotonic systems. We also discuss damage mitigation and ruggedization strategies for future device-scale studies and applications requiring high power beam manipulation.

36 MATERIALS SCIENCE↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗