Search NASA⌕ Search

SEARCH · Search NASA

Results for “silver ion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Semi-Dynamic Leach Testing of Densified Silicon-based Iodine Waste Forms

Iodine waste forms (IWF) require a conceptual corrosion release model (CCRM) to provide iodine (I) release rates for performance modeling nuclear waste disposal repositories. To develop a CCRM, an understanding of the corrosion mechanisms of the IWF are required along with data from consistent test methods to parameterize the model. The present study has advanced both areas by providing and assessing the corrosion resistance of IWF types based on their processing history in minor variations of semi-dynamic leach tests. The test included a series of semi-dynamic leach tests using monolithic IWFs in deionized water (leachant). Several experiments were conducted under alternate test conditions with changes to temperature, leachant replacement, leachant pH, leachant volume, masking, and surface finish to elucidate if varying these conditions impacted IWF corrosion behavior. Tests were conducted on two classes of IWFs: (1) I-bearing silver-mordenite (AgZ) materials processed by hot isostatic pressing (HIP) at different temperatures, pressures, sizes, and times; and (2) I-bearing silver-functionalized silica aerogels (SFA) processed by either HIP or spark plasma sintering (SPS). The corrosion susceptibility of AgZ samples was influenced by HIP temperature and pressure. The SPS SFAs retained I far better than HIP SFAs. Additional findings in this study include: (1) The iodine dissolution rate decreased with decreasing temperature, (2) a common ion effect may occur and slow dissolution of the host phase if the leachant is not regularly replaced, (3) pH controls the dissolution rate, and (4) the iodine dissolution rate slows with extended test time (up to 224 days). Based on this work, these parameters should thus be represented when developing a CCRM.

corrosion↗

Preparation of a 73 As source sample for application in an offline ion source

For the generation of beams with the offline ion source at the Facility for Rare Isotope Beams (FRIB), suitable source samples are required. Arsenic-73 is a frequently requested user beam due to its significance in nuclear structure studies and astrophysics. In this work, we outline the process of preparing a 73 As source sample, containing (5.76 ± 0.37)∗10 14 atoms of 73 As, which was successfully used to generate a 73 As beam for a multi-day user experiment. Silver arsenate was chosen as the chemical form, due to its favorable volatility within the designated operating temperature range. We refined the precipitation method using stable arsenic prior to its application with the 73 As sample, resulting in precipitation yields of (99.4 ± 4.5)%.

As-73↗

Atomic oxygen-metal surface studies as applied to mass spectrometer measurements of upper planetary atmospheres

The problem of atomic oxygen loss in mass spectrometer ion sources can be reduced to an understanding of the possible surface interactions between oxygen atoms and the metal surface of the ion source. Results are presented for an experimental study in which an atomic oxygen beam apparatus and a mass spectrometer were used to measure the oxygen atom reflection, recombination, general surface reaction, and occlusion probabilities on six different engineering surfaces as a function of atomic oxygen exposure. The materials studied are gold, Nichrome V, aluminum, titanium, silver, and platinum. The variation in measured reflection probability seems to occur with metals that form oxides, Nichrome V being stable in terms of reflection stability. Recombination is observed an all surfaces except aluminum and platinum. Variation in the complete set of measurements in a single experiment is the result of varying surface conditions.

Sjolander, G. W.↗

Electron-electron interactions in low-dimensional Si:P delta layers

Scientists have long studied the physics of highly disordered conducting systems, seeking to understand the multitude of quantum phenomena that govern how electrons move through material systems. Recently, research into silicon-based quantum computing has made disordered conducting systems, such as Si:P monolayers embedded in isotopically pure Si, technically relevant. Consequently, applying and advancing the theoretical frameworks developed to describe electron behavior in disordered systems is a necessary objective in this field of research. This study investigates key components of dopant-based Si quantum computing devices: embedded regions of highly doped delta layers (δ layers). We examine the transport behavior and the electron-electron interaction (EEI) physics in embedded Si:P δ layers by means of self-consistent magnetotransport measurements. Parameters associated with the electronic transport offer a meaningful quantitative characterization of δ-layer quality and dopant diffusion. In addition, by examining EEI behaviors in a set of samples with embedded Si:P δ layers produced with different PH3 exposure procedures prior to Si encapsulation, we show how details of material synthesis affect the dimensionality of charge carrier interactions in embedded Si:P δ layers. Furthermore, the relationship between δ-layer confinement and EEI screening lengths is established here. This understanding will help validate important models used for device simulation and design and lead to improvements in the control of electrostatic gating of and tunneling transport through Si:P single atom transistors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Water Conditioner

The Aqualizer is designed to cleanse water with minimal use of chemicals by stabilizing the ions in the water. Its applications are both recreational and industrial. A non-electrical passive device, the Aqualizer operates on the principle of catalytic water conditioning. It consists of a stainless steel pipe length with a helical core and is offered in a variety of sizes depending on the quantity of water to be treated. The device is based on NASA silver ionization technology used to purify drinking water aboard the Apollo spacecraft.

Source record↗

Results of examination of silvered Teflon from the Long Duration Exposure Facility

A significant effort to determine the effects of low earth orbit (LEO) exposure on silver backed fluorinated ethylene-propylene (FEP) blankets from the Long Duration Exposure Facility (LDEF) was performed, and the results of this investigation are described. Extensive measurements of surface, optical, chemical, and mechanical properties were conducted. Effects of contamination and erosion rates of the FEP layer were determined. Specific results are reported on solar absorptance, thermal emittance, diffuse reflectance, cross sectional microphotography, secondary ion mass spectroscopy, electron scattering for chemical analysis, scanning electron microscopy, percent elongation, and tensile strength. These measurements show the effects of two distinctly different exposure environments, solar exposure, and simultaneous atomic oxygen (AO) and solar exposure.

Rousslang, Ken↗

Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

NASA Program Advanced Human Support Technology↗

Space Flight Effects on Intracellular Ions in Sublingual Cells of Non-Human Primates

We have used a novel technique that quantifies minerals and electrolytes from smears of sublingual cells by x-ray microanalysis to monitor metabolic changes in bed rest subjects. Increases in intracellular calcium (Ca), phosphorus (P), and potassium (K) were characteristic of subjects whose exercise regimen was inadequate to maintain calcium metabolism. To test the effects of space flight on intracellular ions, we analyzed cells from 2-4 kg Rhesus monkeys before and after 2 weeks in space or chair restraint (CR). There were increases in sublingual cell Ca, P and K after space flight which paralleled the clinical estimates of metabolic status of the animals and exceeded the levels found during CR on R+11. Increases after 2 weeks CR were 26% in Ca, 6% in P and 29% in K. Species similarity ill responses of intracellular ions to inactivity imposed by bed rest, restraint or microgravity suggest that this innovative non-invasive technique would be a useful in-flight monitor of exercise countermeasures directed toward maintaining calcium balance.

Arnaud, Sara B.↗

Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

Wrbanek, John D.↗

Calibration of a cylindrical RF capacitance probe

The calibration is considered of an RF antenna capacitance probe carried aboard the RAE-1 spacecraft and the correction of the probe for external effects, believed to be primarily due to local positive ion sheaths and/or photoelectron sheaths surrounding the antenna. The RAE-1 spacecraft was launched in July 1968 into a 5850-km. Circular orbit of 121-degree inclination and carried several antenna and radiometer systems covering a frequency range of 0.2 to 9.2 MHz for radio astronomical studies. The RF capacitance probe measurements discussed utilized a 37-meter electric dipole antenna formed by two monopoles made of silver-coated beryllium-copper alloy tapes formed into hollow cylindrical tubes 1.3 cm in diameter.

Mosier, S. R.↗

Nanopore-Templated Silver Nanoparticle Arrays Photopolymerized in Zero-Mode Wavelengths

In situ fabrication of nanostructures within a solid-polymer electrolyte confined to subwavelength-diameter nanoapertures is a promising approach for producing nanomaterials for nanophotonic and chemical sensing applications. The solid-polymerelectrolyte can be patterned by lithographic photopolymerization of poly(ethyleneglycol) diacrylate (PEGDA)-based silver cation (Ag+)-containing polyelectrolyte. Here, we present a new method for fabricating nanopore-templated Ag nanoparticle (AgNP)arrays by in situ photopolymerization using a zero-mode waveguide (ZMW) array to simultaneously template embedded AgNPs and control the spatial distribution of the optical field used for photopolymerization. The approach starts with an array of nanopores fabricated by sequential layer-by-layer deposition and focused ion beam milling. These structures have an optically transparent bottom, allowing access of the optical radiation to the attoliter-volume ZMW region to photopolymerize a PEGDA monomer solution containing AgNPs and Ag+. The electric field intensity distribution is calculated for various ZMW optical cladding layer thicknesses using finite-element simulations, closely following the light-blocking efficiency of the optical cladding layer. The fidelity of the polyelectrolyte nanopillar pattern was optimized with respect to experimental conditions, including the presence or absence of Ag+ and AgNPs and the concentrations of PEGDA and Ag+. The self-templated approach for photo patterning high-resolution photolabile polyelectrolyte nanostructures directly within a ZMW array could lead to a new class of metamaterials formed by embedding metal nanoparticles within a dielectric in a well-defined spatial array.

Zero-mode waveguide↗

Lithium and sodium superionic conductors

Presented are new, earth-abundant lithium superionic conductors, Li3Y(PS4)2 and L15PS4Cl2, that emerged from a comprehensive screening of the Li—P—S and Li—M—P—S chemical spaces. Both candidates are derived from the relatively unexplored quaternary silver thiophosphates. One key enabler of this discovery is the development of a first-of-its-kind high-throughput first principles screening approach that can exclude candidates unlikely to satisfy the stringent Li+ conductivity requirements using a minimum of computational resources. Both candidates are predicted to be synthesizable, and are electronically insulating. Systems and methods according to present principles enable new, all-solid-state rechargeable lithium-ion batteries.

Zhu, Zhuoying↗

Lithium and sodium superionic conductors

Presented are new, earth-abundant lithium superionic conductors, Li 3 Y(PS 4 ) 2 and Li 5 PS 4 Cl 2 , that emerged from a comprehensive screening of the Li—P—S and Li-M-P—S chemical spaces. Both candidates are derived from the relatively unexplored quaternary silver thiophosphates. One key enabler of this discovery is the development of a first-of-its-kind high-throughput first principles screening approach that can exclude candidates unlikely to satisfy the stringent Li+ conductivity requirements using a minimum of computational resources. Both candidates are predicted to be synthesizable, and are electronically insulating. Systems and methods according to present principles enable new, all-solid-state rechargeable lithium-ion batteries.

Zhu, Zhuoying↗

Long Life, High Energy Silver-Zinc Batteries

This viewgraph presentation includes: 1) an introduction to RBC Technologies; 2) Rechargeable Zinc Alkaline (RZA(tm)) Systems which include MnO2/Zn, Ni/Zn, Ag/Zn, and Zn/Air; and 3) RZA Silver/Zinc Battery Developments. Conclusions include the following: 1)Issues with long term wet life and cycle life of the silver/zinc battery system are being overcome through the use of new anode formulations and separator designs; 2) Performance may exceed 200 cycles to 80% of initial capacity and ultimate wet-life of > 36 months; and 3) Rechargeable silver/zinc batteries available in prismatic and cylindrical formats may provide a high energy, high power alternative to lithium-ion in military/aerospace applications.

Kainthla, Ramesh↗

N -Arylimide Molecular Balances: A Comprehensive Platform for Studying Aromatic Interactions in Solution

Noncovalent interactions of aromatic surfaces play a key role in many biological processes and in determining the properties and utility of synthetic materials, sensors, and catalysts. However, the study of aromatic interactions has been challenging because these interactions are usually very weak and their trends are modulated by many factors such as structural, electronic, steric, and solvent effects. Recently, N-arylimide molecular balances have emerged as highly versatile and effective platforms for studying aromatic interactions in solution. These molecular balances can accurately measure weak noncovalent interactions in solution via their influence on the folded–unfolded conformational equilibrium. The structure (i.e., size, shape, π-conjugation, and substitution) and nature (i.e., element, charge, and polarity) of the π-surfaces and interacting groups can be readily varied, enabling the study of a wide range of aromatic interactions. These include aromatic stacking, heterocyclic aromatic stacking, and alkyl–π, chalcogen–π, silver–π, halogen–π, substituent–π, and solvent–π interactions. The ability to measure a diverse array of aromatic interactions within a single model system provides a unique perspective and insights as the interaction energies, stability trends, and solvent effects for different types of interactions can be directly compared. Some broad conclusions that have emerged from this comprehensive analysis include: (1) The strongest aromatic interactions involve groups with positive charges such as pyridinium and metal ions which interact with the electrostatically negative π-face of the aromatic surface via cation–π or metal–π interactions. Attractive electrostatic interactions can also form between aromatic surfaces and groups with partial positive charges. (2) Electrostatic interactions involving aromatic surfaces can be switched from repulsive to attractive using electron-withdrawing substituents or heterocycles. These electrostatic trends appear to span many types of aromatic interactions involving a polar group interacting with a π-surface such as halogen–π, chalcogen–π, and carbonyl–π. (3) Nonpolar groups form weak but measurable stabilizing interactions with aromatic surfaces in organic solvents due to favorable dispersion and/or solvophobic effects. Furthermore, a good predictor of the interaction strength is provided by the change in solvent-accessible surface area. (4) Solvent effects modulate the aromatic interactions in the forms of solvophobic effects and competitive solvation, which can be modeled using solvent cohesion density and specific solvent–solute interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printed Potentiometric Nitrate Sensors for Use in Soil

Plant-available nitrogen, often in the form of nitrate, is an essential nutrient for plant growth. However, excessive nitrate in the environment and watershed has harmful impacts on natural ecosystems and consequently human health. A distributed network of nitrate sensors could help to quantify and monitor nitrogen in agriculture and the environment. Here, we have developed fully printed potentiometric nitrate sensors and characterized their sensitivity and selectivity to nitrate. Each sensor comprises an ion-selective electrode and a reference electrode that are functionalized with polymeric membranes. The sensitivity of the printed ion-selective electrodes was characterized by measuring their potential with respect to a commercial silver/silver chloride reference electrode in varying concentrations of nitrate solutions. The sensitivity of the printed reference electrodes to nitrate was minimized with a membrane containing polyvinyl butyral (PVB), sodium chloride, and sodium nitrate. Selectivity studies with sulphate, chloride, phosphate, nitrite, ammonium, calcium, potassium, and magnesium showed that high concentrations of calcium can influence sensor behavior. The printed ion-selective and reference electrodes were combined to form a fully printed sensor with sensitivity of −48.0 ± 3.3 mV/dec between 0.62 and 6200 ppm nitrate in solution and −47 ± 4.1 mV/dec in peat soil.

Baumbauer, Carol L. (ORCID:0000000246747551)↗

Measurements of particle emission from discharge sites in Teflon irradiated by high energy electron beams

Anomalous behavior of synchronous orbit satellites manifested by overall degradation of system performance and reduced operating life is associated with electrical discharges resulting from differential charging of the spacecraft surface by fluxes of high energy electrons. During a laboratory simulation silver-backed Teflon samples have been irradiated by electron beams having energies in the range 16-26 keV. Charged particles emitted from the resultant electrical discharges have been measured with a biased Faraday cup and retarding potential analyser. Measurements indicate the presence of two distinct fluxes of particles, the first being an early pulse (0-600ns) of high energy (about 7keV) electrons, while the second is a late pulse (1-5 microseconds) of low energy electrons (less than 1eV) and ions (70eV) leaving the discharge site as a quasi plasma. Calculations indicate an electrostatic field as the dominant accelerating mechanism for charged particles.

Hazelton, R. C.↗

A new material for removing heavy metals from water

The NASA Lewis Research Center developed and is patenting a new high capacity ion exchange material (IEM) that removes toxic metals from contaminated water in laboratory tests. The IEM can be made into many forms, such as thin films, coatings, pellets, and fibers. As a result, it can be adapted to many applications to purify contaminated water wherever it is found, be it in waste water treatment systems, lakes, ponds, industrial plants, or in homes. Laboratory tests have been conducted on aqueous solutions containing only one of the following metal cations: lead, copper, mercury, cadmium, silver, chromium (III), nickel, zinc, and yttrium. Tests were also conducted with: (1) calcium present to determine its effects on the uptake of cadmium and copper, and (2) uranium and lanthanides which are stand-ins for other radioactive elements, (3) drinking water for the removal of copper and lead, and (3) others compositions. The results revealed that the IEM removes all these cations, even in the presence of the calcium. Of particular interest are the results of the tests with the drinking water: the lead concentration was reduced from 142 ppb down to 2.8 ppb (well below the accepted EPA standard).

Philipp, Warren H., Jr.↗