Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Decoupling of Nitrogen and Oxygen Impurities in Nitrogen Doped SRF Cavities

The performance of superconducting radiofrequency (SRF) cavities is critical to enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry of niobium samples baked at temperatures varying from 75-800 $^\circ$C with and without nitrogen injection. From these results, we developed treatments recipe that decouple the effects of oxygen and nitrogen in doping treatments. Understanding how these impurities and their underlying mechanisms drive further optimization in the tailoring of impurity profiles for high-performance SRF cavities.

43 PARTICLE ACCELERATORS↗

Enabling Stable and Salt-Free Formic Acid Production via Reactive Interface Optimization in Forward-Bias Bipolar-Membrane CO2 Electrolyzers

Electrochemical conversion of CO2 to liquid products is limited by parasitic reactions that consume products and destabilize operation. Here, we show that salt-free formic acid synthesis in a forward-bias bipolar-membrane CO2 electrolyzer is governed by a coupled reaction-transport instability driven by parasitic anode formic acid oxidation. Operando mass spectrometry reveals that this process proceeds through CO-mediated poisoning, identifying catalyst tolerance to CO as a key descriptor of anode selectivity. Among the catalysts examined, PtRu/C preferentially promotes hydrogen oxidation over formic acid oxidation. Coupling this catalyst with transport-interface engineering improves product removal, enhances Faradaic and energy efficiency, and enables stable operation at 200 mA/cm2 for 190 h with a voltage decay of 0.64 mV/h. Techno-economic analysis indicates an 18% reduction in minimum selling price and highlights product concentration as the dominant cost lever. These results establish a general framework for suppressing product oxidation in liquid-product electrolyzers.

Hu, Leiming↗

Rapid screening of secondary aromatic metabolites in Populus trichocarpa leaves

Abstract Background High-throughput metabolomics analytical methodology is needed for population-scale studies of bioenergy-relevant feedstocks such as poplar ( Populus sp.). Here, the authors report the relative abundance of extractable aromatic metabolites in Populus trichocarpa leaves rapidly estimated using pyrolysis-molecular beam mass spectrometry (py-MBMS). Poplar leaves were analyzed in conjunction with and validated by GC/MS analysis of extracts to determine key spectral features used to build PLS models to predict the relative composition of extractable aromatic metabolites in whole poplar leaves. Results The Pearson correlation coefficient for the relative abundance of extractable aromatic metabolites based on ranking between GC/MS analysis and py-MBMS analysis of the Boardman leaf set was 0.86 with R 2 = 0.76 using a simplified prediction approach from select ions in MBMS spectra. Metabolites most influential to py-MBMS spectral features in the Clatskanie set included the following compounds: catechol, salicortin, salicyloyl-coumaroyl-glucoside conjugates, α-salicyloylsalicin, tremulacin, as well as other salicylates, trichocarpin, salicylic acid, and various tremuloidin conjugates. Ions in py-MBMS spectra with the highest correlation to the abundance of extractable aromatic metabolites as determined by GC/MS analysis of extracts, included m/z 68, 71, 77, 91, 94, 105, 107, 108, and 122, and were used to develop the simplified prediction approach without PLS models or a priori measurements. Conclusions The simplified py-MBMS method is capable of rapidly screening leaf tissue for relative abundance of extractable aromatic secondary metabolites to enable prioritization of samples in large populations requiring comprehensive metabolomics that will ultimately inform plant systems biology models and advance the development of optimized biomass feedstocks for renewable fuels and chemicals.

09 BIOMASS FUELS↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗

Rapid evaluation of particle properties using inverse SEM simulations

The characteristic X-rays produced by the interactions of the electron beam with the sample in a scanning electron microscope (SEM) are usually captured with a variable-energy detector, a process termed energy dispersive spectrometry (EDS). The purpose of this work is to exploit inverse simulations of SEM-EDS spectra to enable rapid determination of sample properties, particularly elemental composition. This is accomplished using penORNL, a modified version of PENELOPE, and a modified version of the traditional Levenberg Marquardt nonlinear optimization algorithm, which together is referred to as MOZAIK-SEM. The overall conclusion of this work is that MOZAIK-SEM is a promising method for performing inverse analysis of X-ray spectra generated within a SEM. As this methodology exists now, MOZAIK-SEM has been shown to calculate the elemental composition of an unknown sample within a few percent of the actual composition.

Bekar, Kursat B↗

Correlating viscosity and die swell in 3D printing of polyphenylsulfone: A thermo-mechanical optimization modus operandi

Additive manufacturing (AM) of polyphenylsulfone (PPSU), an amorphous high-performance polymer (HPP), has shown promise in exhibiting structural integrity for many applications. With thermoplastic material extrusion 3D printing, parts consisting of layered melts exhibited voids, where the adhesion quality and void size depend on the processing parameters implemented during printing. However, the structure-process-property (SPP) relationships between the thermal properties and rheological and mechanical behavior of AM PPSU are poorly understood. Here, in this study, a comprehensive analysis of the thermal, thermo-mechanical, and layer-by-layer build-up of PPSU is investigated and correlated with viscosity and extrudate die swell behavior with void fraction volume as confirmed by high-resolution x-ray computed tomography (XCT). Gas chromatography–mass spectrometry (GC–MS) pyrolysis confirmed PPSU composition and degradation at 480 °C, consistent with thermo-gravimetric analysis TGA. A 141% difference in viscosity was observed when processing temperatures increased from 350 °C to 400 °C. Likewise, extrudate die swell decreased with increasing temperatures, resulting in a 17% difference. Tensile and compressive properties confirmed that higher extruding temperatures resulted in lower porosity and higher mechanical strength. In general, higher extruding temperatures lower the viscosity to allow for stronger cohesion between layers; however, increasing the temperature too high results in a below unity extrudate die swell, reducing mechanical properties. Therefore, to optimize the mechanical integrity of 3D printed amorphous PPSU parts, an increase in the viscosity, near unity of the extrudate die swell, and tempered extrusion temperature are needed.

36 MATERIALS SCIENCE↗

SCOMAP-XD : atomistic deuterium contrast matching for small-angle neutron scattering in biology

The contrast-variation method in small-angle neutron scattering (SANS) is a uniquely powerful technique for determining the structure of individual components in biomolecular systems containing regions of different neutron scattering length density ρ . By altering the ρ of the target solute and the solvent through judicious incorporation of deuterium, the scattering of desired solute features can be highlighted. Most contrast-variation methods focus on highlighting specific bulk solute elements, but not on how the scattering at specific scattering vectors q , which are associated with specific structural distances, changes with contrast. Indeed, many systems exhibit q -dependent contrast effects. Here, a method is presented for calculating both bulk contrast-match points and q -dependent contrast using 3D models with explicit solute and solvent atoms and SASSENA , an explicit-atom SANS calculator. The method calculates the bulk contrast-match points within 2.4% solvent D 2 O accuracy for test protein–nucleic acid and lipid nanodisc systems. The method incorporates a general model for the incorporation of deuterium at non-exchangeable sites that was derived by performing mass spectrometry on green fluorescent protein. The method also decomposes the scattering profile into its component parts and identifies structural features that change with contrast. The method is readily applicable to a variety of systems, will expand the understanding of q -dependent contrast matching and will aid in the optimization of next-generation neutron scattering experiments.

59 BASIC BIOLOGICAL SCIENCES↗

A Mission-Enabling UV Laser for Mass Spectrometry (UVMS) with Continuously Selectable Output for In Situ Planetary Exploration

Ultra-compact, ns-class spaceflight-compatible UV lasers are finding increasing application in laser desorption, excitation, and ionization analytical applications on planetary missions, such as the detection and characterization of potential molecular biosignatures on Mars or icy moon surfaces. A short pulsed, solid state, UV laser is under development with selectable pulse energy capabilities for optimized sample ion production at a planetary surface.

Coyle, D. Barry↗

Evaluating Separation Selectivity and Collision Cross Section Measurement Reproducibility in Helium, Nitrogen, Argon, and Carbon Dioxide Drift Gases for Drift Tube Ion Mobility–Mass Spectrometry

Previous ion mobility (IM) studies have demonstrated that varying the drift gas composition can be used to enhance chemical selectivity and resolution, yet there are few drift gas studies aimed at achieving quantitatively reproducible mobility measurements. Here, we critically evaluate the conditions necessary to achieve reproducible collision cross section (CCS) measurements in pure drift gases (helium, nitrogen, argon, and carbon dioxide) using a commercial uniform field drift tube instrument. Optimal experimental parameters are assessed based on the convergence of CCS measurements to reproducible values which are compared with literature values. A suite of calibration standards with diverse masses, biological classes, and charge states are examined to assess chemical selectivity and resolution achievable in each drift gas. Results indicate nitrogen and argon perform similarly and are sufficient for most applications where high resolving power and high peak capacity are desired. Carbon dioxide exhibits more selectivity for resolving structurally heterogeneous compounds, which may be preferable in specific analyte pair separations. Helium demonstrated modest separation capabilities but has utility for comparison to theoretical values and previously published work. In drift gases other than nitrogen, pressure differentials up to 230 mTorr between the drift tube and upstream chamber were optimal for improving correlation to literature values, while in nitrogen, the recommended pressure differential of 150 mTorr was found appropriate. We present recommended experimental parameters as well as gas-specific CCS measurements for structurally homogeneous sets of analytes which are suitable for use by other laboratories as standards for purposes of instrument calibration and overall assessment of IM separation performance. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Engineering Active Surface Oxygen Sites of Cubic Perovskite Cobalt Oxides toward Catalytic Oxidation Reactions

Unraveling the role of surface oxygen sites in transition metal oxides during catalytic reactions has always been the focus of environmental and energy chemistry research. For this work, active surface oxygen sites of cubic perovskite cobalt oxide were engineered to comprehend their crucial role and catalytic mechanism at the molecular level. By removing those inert Sr/La–O termination layers, active oxygen sites were exposed on the Co terminated surface of Sr 0.6 La 0.4 CoO 3–δ that furnished the dominant catalytic process of CO oxidation via the Mars–van Krevelen (MvK) mechanism. The fabrication of five-coordinate cobalt ions and the enhanced covalency of Co–O bonds not only optimize the surface electronic structure of Co 3d–O 2p, but also supply active surface oxygen sites, which effectively oxidizes CO to CO 2 with a significantly improved oxidation performance and stability as evidenced by soft/hard XAS, XPS, and O 2 -TPD. Furthermore, online isotopic 18 O 2 mass spectrometry, in situ DRIFTS, and theoretical simulation demonstrate that the activity of surface oxygen sites enhances the kinetics of the MvK reaction, while unsaturated coordination sites from five-coordinate cobalt ions primarily contribute to the activated oxygen molecules and the stable catalytic cycle. The results reported here provide a deep insight into the comprehension of the relationships among active oxygen sites, surface electronic structure, and the reaction mechanism of transition metal oxides necessary for catalytic oxidation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Decontamination of Irradiated Nuclear Graphite Using High Temperature Molten Salt - 17447

Irradiated graphite is one of the most significant, large volume waste streams in the UK. After shut down of gas cooled reactors there will be ∼96,000 tonnes of nuclear graphite arising from pressure vessels, sealed or unsealed stacks, temporary surface storage and in silos, which may account for up to 30% by ILW volume of any future UK geological disposal facility. High temperature molten salt treatment (HMST) could be considered as a partitioning process of the activation and fission products from irradiated graphite. The main objective of the research is to optimize a specific graphite treatment technology compatible with older, current and future reactors to provide a safe and effective process to decontaminate graphite and reduce the waste inventory. In order to reach that purpose principal radionuclides contained in irradiated samples from Magnox reactors were investigated by germanium (Ge) gamma spectrometry. The next key tasks were to employ treatment at 450 deg. C in LiCl-KCl eutectic which included the following procedures: electrochemical cleaning of the salt, initial cyclic voltammetry (CV) of graphite followed by several steps of chrono-potentiometry (CP) with different current applied and CV was taken after each step. Once the treatment was established, experiments investigating the electro-refinement of the resultant salt mixtures were conducted as well as the comparison of gamma spectroscopy results of graphite before and after the treatment providing the result of total activity reduction of around 60%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the practicality of a minimally defined co-axial HPGe detector model using MCNP

An MCNP model of a co-axial HPGe detector, defined by the specification sheet and without parameter optimization, was used to assess practicality for efficiency characterization and complex spectra simulation. Simulated efficiencies, with and without Gaussian energy broadening, were compared against an experimental calibration for a standard counting geometry. Results show that this minimal detector model predicted efficiencies within 6% of experimental values at energies above 100 keV, while including energy broadening offered little improvement. Furthermore, this work shows that extensive detector characterization and optimization of parameters is not absolutely necessary, thereby reducing the experimental burden associated with detector modeling for many applications.

42 ENGINEERING↗

Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry

Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by portable mass spectrometers. Here, we demonstrate that by using a 10 kHz, ~2.5 kV{sub p-p} high-voltage square-wave alternating current plasma, active capillary DBDI can consume less than 1 μW of power. In contrast, the power consumed using a sine and triangle alternating current waveform is more than two orders of magnitude higher than that for the square waveform to obtain a similar voltage for plasma generation. Moreover, the plasma obtained using a square waveform can be significantly more homogenous than that obtained using sine and triangle waveforms. Protonated dimethyl methylphosphonate (DMMP) and deprotonated perfluorooctanoic acid (PFOA) can be detected at about the same or higher abundances using square-wave DBDI mass spectrometry compared with the use of sine and triangle waveforms. By use of benzylammonium thermometer ions, the extent of internal energy deposition using square, sine, or triangle waveform excited plasmas are essentially the same at the optimum voltages for ion detection. Using an H-bridge circuit driving a transformer optimized to reduce losses, square-wave active capillary DBDI can be continuously powered for ~50 h by common 9 V-battery (PP3). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Historic climate, cosmogenic 10Be, denudation-rate, and geospatial datasets from the Pikes Peak region, Colorado, USA

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of elevation-dependent denudation rates on Pikes Peak in the Front Range of the Rocky Mountains, Colorado, USA. The package includes GIS layers used to produce the study-area map, including sample locations, sample watershed boundaries, the Pikes Peak batholith, Pleistocene glacier extent, weather station locations, and elevation and hillshade rasters, together with comma-separated value (CSV) tables and matching CSV data dictionaries. These mapped layers provide the geographic framework for interpreting denudation patterns across the Pikes Peak region and for relating sample locations to watershed geometry, bedrock setting, glacial history, and nearby climate stations. The first group of tables reports climate and geospatial context for the study area. These files include station-based temperature and precipitation data used to characterize elevational gradients in mean annual climate and monthly climate seasonality, sample locations, denudation-rate and topographic metrics, fixed frost-cracking model parameters, frost-cracking intensity and precipitation-frequency metrics, and stream-power inversion results. Together, these data provide the basis for evaluating how denudation varies with elevation, climate, and landscape form across sampled catchments on Pikes Peak. The second group of tables reports cosmogenic nuclide and erosion-model results used in the denudation analysis. Included files contain accelerator mass spectrometry (AMS) measurements for in situ-produced cosmogenic beryllium-10 (10Be), including sample identifiers, measured 10Be:9Be ratios, analytical uncertainties, carrier mass, quartz mass, blank corrections, blank-group statistics, and calculated 10Be concentrations and uncertainties. Additional tables summarize stream-power-law inversion results for sampled catchments, including optimized model parameters, predicted erosion rates, residual metrics, channel-pixel counts, and convergence status, as well as regression equations and summary statistics used to evaluate relationships among elevation, climate, frost cracking, precipitation forcing, and denudation rate. The package contains GIS files, comma-separated value files (.csv), Microsoft Excel files (.xlsx), CSV data dictionaries, a file-level metadata table, and a readme text file.

10Be cosmogenic nuclides↗

Measurement of CH{sub 3}D on Titan at Submillimeter Wavelengths

We present the first radio/submillimeter detection of monodeuterated methane (CH{sub 3}D) in Titan’s atmosphere, using archival data from of the Atacama Large Millimeter/submillimeter Array (ALMA). The J {sub K} = 2{sub 1}−1{sub 1} and J {sub K} = 2{sub 0}−1{sub 0} transitions at 465.235 and 465.250 GHz (∼0.644 mm) were measured at significance levels of 4.6σ and 5.7σ, respectively. These two lines were modeled using the Non-linear optimal Estimator for MultivariatE spectral analySIS (NEMESIS) radiative transfer code to determine the disk-averaged CH{sub 3}D volume mixing ratio = 6.157 × 10{sup −6} in Titan’s stratosphere (at altitudes >130 km). By comparison with the CH{sub 4} vertical abundance profile measured by Cassini–Huygens mass spectrometry, the resulting value for D/H in CH{sub 4} is (1.033 ± 0.081) × 10{sup −4}. This is consistent with previous ground-based and in situ measurements from the Cassini–Huygens mission, though slightly lower than the average of the previous values. Additional CH{sub 3}D observations at higher spatial resolution will be required to determine a value truly comparable with the Cassini–Huygens CH{sub 4} measurements, by measuring CH{sub 3}D with ALMA close to Titan’s equator. In the post-Cassini era, spatially resolved observations of CH{sub 3}D with ALMA will enable the latitudinal distribution of methane to be determined, making this an important molecule for further studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗