Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Shuttle Spacelab Core Equipment Freezer

This paper describes the preliminary design of a Shuttle Spacelab Core Equipment Freezer. The unit will provide the capability to freeze and store many experiment specimens. Two models of the unit are planned. One model provides storage at -70 C; the other model will provide -70 C storage, a freeze dry capability, storage at a selectable temperature in the range of 0 C to -70 C, and means of maintaining close temperature tolerances. In addition an exchanger loop will be available at 4 C for cooling of a centrifuge and a remote storage compartment. A test tube holder, a dish holder and thermal capacitors for rapid freezing of large specimens will also be provided. A Stirling Cycle was selected as the active refrigerator for minimum cost and weight.

Copeland, R. J.↗

Additive Manufacturing of Thermal Energy Storage Composites with Microencapsulated Phase Change Materials Supported in a Multi-Polymer Matrix

Advanced manufacturing techniques, such as additive manufacturing (AM), that can directly integrate phase change materials (PCMs) have garnered interest in recent years due to their potential for development of highly efficient thermal energy storage architectures. Complex, high surface area geometries embedded with PCMs that are only feasible with AM can improve thermal management with reduced material waste. Our work focuses on developing composite filaments with microencapsulated phase change materials (MEPCM) bound within a single or dual polymer matrix that can be processed through standard filament extruders and additively manufactured using off-the-shelf 3D printers. Polymer powders, rather than polymer pellets, were key to homogenously mixed filaments achieving high MEPCM loadings with no deterioration in thermal energy storage (TES) capability during extrusion. Composite filaments contain upwards of 60 wt% MEPCM and were printed without loss in feature resolution, print speed, or layer adhesion. Storage enthalpies of printed composites range from 100 - 130 kJ/kg, which were within 5% of the theoretical enthalpy based on weight fraction of MEPCM and maintained enthalpies within 1% over 500 thermal cycles. We can reliably manufacture low density, high surface area structures like 15% gyroid infill, along with dense, compact pucks at a 100% concentric infill. Prints were also scalable to a 900 cm3 honeycomb infill heat exchanger model that has an estimated energy storage capacity of 9 Wh.

3D printing↗

Project developer options to enhance the value of solar electricity as solar and storage penetrations increase

Increasing the penetration of photovoltaics (PV) reduces the marginal grid value of PV electricity. The declining grid value of PV with higher penetration could limit the technology's economic attractiveness and future demand. Various strategies have been proposed for preserving this value. Using a consistent framework, we analyze the net value (accounting for both cost and grid value) of more than ten strategies in the United States. Here, grid value is estimated from coincident wholesale power market prices and PV generation using observed historical prices or modeled future prices with up to 30% PV penetration. We find that established and emerging strategies designed to shift the timing of standalone PV generation at the expense of total generation—including orienting monofacial PV modules west or bifacial modules vertically—result in minor net-value benefits or penalties. Adding energy storage to such systems magnifies the net-value loss, because configurations that change the timing of PV production become redundant when the energy-shifting capabilities of storage are added. The largest net-value gains come from strategies that maximize generation (solar tracking plus oversized PV arrays) in conjunction with storage, especially at high PV penetrations. PV systems are long-lived assets. Our results suggest that efforts to promote generation-maximizing strategies today may yield increasing net-value benefits as PV and storage deployments continue to accelerate in the United States over the coming decades.

14 SOLAR ENERGY↗

Improved lithium storage capacity and high rate capability of nitrogen-doped graphite-like electrode materials prepared from thermal pyrolysis of graphene quantum dots

Adopting a solid-phase microwave-assisted technique followed by thermal pyrolysis of N-functionalized graphene quantum dots, novel nitrogen-doped graphite-like (NGL) electrode materials were synthesized in this work and served as the anode for Li-ion batteries. The NGL anode demonstrated reversible capacity of 530 mAh g -1 at 0.1C, superior rate capability at high C rate operation (420 mAh g -1 at 5C), remarkable initial coulombic efficiency (>95.7%), and excellent cyclic stability along with high efficiency (>99.1%) during entire cycling. The NGL anode nanostructure enables improved lithium ion mobility and reversible Li + storage during cycling. The analysis of the Ragone plots revealed that the specific energy of NGL anode reaches to ca. 840 Wh kg -1 at the power density of 4200 W kg -1 . The diffusion coefficient of Li ions was measured as 1.69 × 10 -9 cm 2 s -1 for the NGL anode material, substantially improving over commonly used graphite electrodes (15–26 times higher Li + diffusivity). The high-rate cyclability as well as the cyclic stability of the NGL anodes were also confirmed via long-term cycling of full pouch cells assembled with ternary cathode and NGL anode. The robust design of the NGL anode materials introduced in this work, paves the way for designing next-generation lithium-ion batteries operating at ultra-high C rates.

25 ENERGY STORAGE↗

Space Station thermal storage/refrigeration system research and development

Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).

Dean, W. G.↗

Modeling and Optimization Methods for Controlling and Sizing Grid-connected Energy Storage: A Review

Purpose of Review Energy storage is capable of providing a variety of services and solving a multitude of issues in today's rapidly evolving electric power grid. This paper reviews recent research on modeling and optimization methods for optimally controlling and sizing grid-connected battery energy storage systems (BESSs). Open issues and promising research directions are discussed. Recent Findings Recent studies on BESS dispatch, evaluation, and sizing focus on advanced modeling and optimization methods to maximize stacked value streams from multiple services. BESS models have been improved to better represent operational characteristics or capture degradation effects. Different solution methods and optimization techniques have been proposed to improve the benefits and cost-effectiveness of BESSs, using deterministic approaches prevalently but with impressive progress in capturing and addressing uncertainties. Summary Recent progress in BESS scheduling and sizing better supports planning and operational decision-making in different use cases, which is highly important to advance the deployment of BESSs. Additional research is required to properly model the trade-off between short-term benefits and service life with multiple degradation effects explicitly considered in the decision-making process. Advanced methods are to be developed for effectively determining optimal BESS sizes that maximize overall benefits within a varying lifetime considering diversified system, conditions as well as uncertainties at planning and operational stages.

Wu, Di↗

Melt-Spun PAN Precursor for Cost-Effective Carbon Fibers in High Pressure Compressed Gas Tankage

The objective of this program was to synthesize melt-spinnable polyacrylonitrile (PAN) precursor that will lead to carbon fiber 25% less expensive than carbon fiber produced from conventional PAN precursor when produced in large volumes. The carbon fiber produced from this precursor needs to achieve ≥ 700 ksi tensile strength with this cost reduction to replace the incumbent fiber. In this program, the technology for producing precursor and then converted carbon fiber (CF) capable of meeting the 700 ksi target was to be demonstrated at a small scale in tows, containing ≥ 100 filaments. If this program moved on to a “Phase 2”, the processes would be scaled up to produce and test Type IV compressed gas storage tanks capable of meeting the 700-bar ultimate targeted FOA performance level. Precursor fiber production typically contributes a large fraction (~50%) to finished CF manufactured cost. Presently, all high strength CFs are manufactured from solution spun PAN precursor, accomplished at low temperatures using large amounts of environmentally unfriendly solvents that impart major impact to line speed and costs involved with handling and reclaiming the solvents and associated “waste streams” required in spinning and extracting those solvents. PAN melt spinning was demonstrated by the company BASF in CF precursor production and used in production of some other acrylic fibers, but significant production challenges remain for meeting the established CF metrics. Melt spinning requires use of plasticizers to suppress the melt temperature of the predominantly PAN formulation to a point sufficiently below the temperature of significant cross-linking. Fortunately, BASF and this team’s earlier work had demonstrated acrylic formulations melt spun with combinations of plasticizing solvents at much lower solvent levels. This project team made significant progress in understanding technical issues and identifying formulation pathways in earlier work in this area where >250ksi strength was achieved. The goal of this program was to pursue a more comprehensive approach with a larger, more diverse team having greater equipment design and overall production capabilities to push rapidly beyond the science to resolve remaining “engineering” issues associated with establishing stable, continuous processes for precursor fiber leading to enhanced, cost-effective CF and composite tank production.

36 MATERIALS SCIENCE↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Graphitized Biocarbon Derived from Hydrothermally Liquefied Low-Ash Corn Stover

Graphitized biocarbon can be utilized for energy storage applications such as supercapacitors. The scientific community have geared their attention to obtain such value-added product from abundantly available and low-cost biomass feedstock agricultural residues such as corn stover. Lignocellulosic components embedded within the cell wall of biomass substrates can provide a fine template for enhanced ion storage, transport, and rate capabilities, desirable for electrochemical storage. Presented is the utilization of homogenized low ash content corn stover milled and sieved to desired specifications, which underwent hydrothermal liquefaction in the presence of Ni-based catalytic salts at 275 o C. The hydrochar obtained by solid residue extracted from the reaction slurry was washed to acid neutral and subjected to catalytic activation using ZnCl 2 , followed by thermal annealing at 400 o C for morphological and pore size enhancement of the resulting biochar. Carbonization was performed on acid neutralized hydrochar at 850 °C to further enhance pore structures and increase graphitization for improved conductivity. Catalytic materials exhibited a specific capacitance of 316 F g -1 and held a 100% retention beyond 10,000 cycles. BET, Raman, XRD, cyclic voltammetry, chronopotentiometry, and EIS are discussed herein.

Biomass↗

Stabilization and control of persistent current magnets using variable inductance

Ultra-stable, tunable magnetic fields are desirable for a wide range of applications in medical imaging, electron microscopy, quantum science, and atomic physics. Superconducting magnets operated in persistent current mode, with device current flowing in a closed superconducting loop disconnected from a power source, are a common approach for applications with the most stringent requirements on temporal field stability. In this work, we present a method for active control of this persistent current by means of dynamic inductance change within the superconducting circuit. For a first realization of this general technique, we consider a variable superconducting inductor placed in series with the main magnet. The inductor acts as a dynamic flux storage device capable of transferring flux to or from the main magnet through inductance change. This allows for fine and fast adjustments of the persistent current without the use of thermal switches that limit the speed and accuracy of many present-day methods. With first experiments employing this technique, we demonstrate stabilization of a 1.95 T Nb–Ti round lens for electron microscopy against decay resulting from residual losses in the superconducting circuit, and more generally show flexibility for precise control over the magnitude and waveform of the persistent current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parallel I/O Evaluation Techniques and Emerging HPC Workloads: A Perspective

Emerging workloads such as artificial intelligence, big data analytics and complex multi-step workflows alongside future exascale applications are anticipated future HPC workloads, which will result in a more diverse I/O system workload and even less predictable I/O behavior and access patterns. Along with the ever increasing gap between the compute and storage performance capabilities, the in-depth understanding of extreme-scale I/O behavior and the I/O performance modeling and prediction are essential tools of the large-scale I/O evaluation process for addressing the needs of extreme-scale hybrid workloads. In this survey article, we focus on the state-of-the-art of the I/O behavior and performance analysis process for HPC systems in a 5-year time window and identify future research challenges.

Neuwirth, Sarah↗

On-Sun Testing of a High-Temperature Solar Receiver's Flux Distribution

Concentrated solar power (CSP) is a promising technology in transitioning to renewable energy because of its abundance in nature and thermal energy storage (TES) capability. Among the four types of available CSP technology, including parabolic trough, linear Fresnel, power tower, and parabolic dishes, a power tower using a central receiver has more potential to generate high-temperature heat in a scale supporting power cycles efficiency and achieve low levelized cost of energy (LCOE). Other than the conventional type of receiver design, the high-absorptive receiver concept developed and presented in this paper is novel in its design approach. The novel receiver design originated from National Renewable Energy Laboratory (NREL) consists of an array of solar flux absorb tubes. The solar absorb tubes require uniform flux distribution and in-depth flux penetration through the three different reflective sections of tubes in a hexagonal shape. To evaluate this unique receiver design and thermal performance, the flux distribution, flux uniformity, and intensity were numerically simulated using ansys fluent and SolTrace modeling program. On-sun testing has been done at NREL high flux solar testing facility, based on the computational analysis.

clean energy↗

Hydra 1 data display system

System, named Hydra, generates charts, graphs, and printed matter on slides or conventional negatives and positives, and combines these media with a capability of storage on magnetic tape for future updating to accommodate engineering changes or contract modifications to be readily added to basic data.

Hodgkins, R. L.↗

A large imaging array CCD program

Test results on charge coupled device (CCD) imaging arrays (100 x 160 pixel and 400 x 400 pixel) employed as imaging detectors are reported, along with expected low light level (LLL) performance. Reasons for selection of a thinned backside-illuminated buried-channel three-phase CCD variant are indicated. The LLL performance and long storage time capability of the CCD imaging array recommend it for stellar photometry, detection and tracking of faint objects, and other astronomical applications.

Vescelus, F. E.↗

Evolutionary growth for Space Station Freedom electrical power system

Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased space station user requirements and advancing technologies. The space station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial space station systems such as guidance navigation and control, external thermal, truss structural stiffness, computational capabilities and storage which must be planned-in in order to facilitate the addition of the solar dynamic modules.

Marshall, Matthew F.↗

Evolutionary growth for Space Station Freedom electrical power system

Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased Space Station user requirements and advancing technologies. The Space Station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial Space Station systems such as guidance, navigation, and control, external thermal, truss structural stiffness, computational capabilities and storage, which must be planned-in, in order to facilitate the addition of the solar dynamic modules.

Marshall, Matthew Fisk↗

Mass storage: The key to success in high performance computing

There are numerous High Performance Computing & Communications Initiatives in the world today. All are determined to help solve some 'Grand Challenges' type of problem, but each appears to be dominated by the pursuit of higher and higher levels of CPU performance and interconnection bandwidth as the approach to success, without any regard to the impact of Mass Storage. My colleagues and I at Data Storage Technologies believe that all will have their performance against their goals ultimately measured by their ability to efficiently store and retrieve the 'deluge of data' created by end-users who will be using these systems to solve Scientific Grand Challenges problems, and that the issue of Mass Storage will become then the determinant of success or failure in achieving each projects goals. In today's world of High Performance Computing and Communications (HPCC), the critical path to success in solving problems can only be traveled by designing and implementing Mass Storage Systems capable of storing and manipulating the truly 'massive' amounts of data associated with solving these challenges. Within my presentation I will explore this critical issue and hypothesize solutions to this problem.

Lee, Richard R.↗