Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3–7.5 keV using synchrotron radiation

Verification of physics models and computer simulations are heavily reliant upon the accuracy of experimental measurements. Calibration of instrument responses becomes an important step to achieve this goal. This paper presents systematic studies of bent potassium acid phthalate (KAP) crystals using Lawrence Berkeley National Laboratories, Advanced Light Source, beamline 9.3.1 in the energy range of 2.3 to 7.5 keV. A set of KAP crystals, gradually bent from flat up to a 50.8 mm cylindrical curvature. The measured integrated reflectivity for this set of KAP crystals shows good agreement with the X-ray Oriented Program (XOP) calculations when adjusting the Debye–Waller temperature factor and using the multilamellar model in the calculations. Significant differences in rocking curve profiles were observed between experimental measurements and theory. A forward convolution model and software code were developed to include experimental parameters, allowing the investigation of the difference between measurements and calculations. After considering the experimental parameters, good agreements were obtained for the rocking curve profiles for all bending radii with a unique set of parameters. Our results show that XOP can be a useful and reliable tool to predict performance of cylindrically bent KAP crystals in this energy range.

Wu, Ming↗

Successful Cleanroom Installation of PIP-II SSR2 Coupler Using Robotic Arm

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam s transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

Narug, C.↗

Emittance Measurements with Wire Scanners in the Fermilab Side-coupled Linac

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam's transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions, which we present here.

43 PARTICLE ACCELERATORS↗

Multimodal hard X-ray nanoprobe techniques for operando investigations of photovoltaic devices

Compared with conventional laboratory-scale X-ray techniques, synchrotron based X-rays with higher brilliance and higher coherence allow for the investigation of various material properties with high spatial resolution. The microscopic behaviours of materials can be examined using the Hard X-ray Nanoprobe beamline (I14) at Diamond Light Source, which provides a 50 nm focused beam and has been successfully employed to identify nanoscale optoelectronic features in energy-harvesting materials such as halide perovskites that exhibit local heterogeneity. We have developed X-ray beam-induced current (XBIC) measurement capability at I14 to address the growing demand for operando analysis in energy-harvesting research. Here, we demonstrate that X-ray fluorescence (XRF)/XBIC multimodal measurements are feasible at I14 and apply these newly implemented techniques to study perovskite solar cells with various additive concentrations to understand the effect of the additive on nanoscale optoelectronic performance. This expanded operando characterization capability offers the possibility of monitoring nanometre-scale compositional variations and corresponding optoelectronic features of actual solar cell configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Powder X-ray diffraction of fluorometholone, C 22 H 29 FO 4

Commercial fluorometholone, CAS #426-13-1, crystallizes in the monoclinic space group P 2 1 (#4) with a = 6.40648(2), b = 13.43260(5), c = 11.00060(8) Å, β = 92.8203(5)°, V = 945.517(5) Å 3 , and Z = 2. A reduced cell search in the Cambridge Structural Database yielded one previous structure determination, using single-crystal data at 292 K. In this work, the sample was ordered from the United States Pharmacopeial Convention (Lot # R032K0) and analyzed as-received. The room temperature (295 K) crystal structure was refined using synchrotron ( λ = 0.412826 Å) powder diffraction data and optimized using density functional theory (DFT) techniques. Hydrogen positions were included as a part of the structure and were re-calculated during the refinement. The diffraction data were collected on beamline 11-BM at the Advanced Photon Source, Argonne National Laboratory, and the powder X-ray diffraction pattern of the compound has been submitted to ICDD® for inclusion in the Powder Diffraction File™. The agreement of the Rietveld-refined and DFT-optimized structures is excellent; the root-mean-square Cartesian displacement is 0.060 Å. In addition to the O–H⋯O hydrogen bonds observed by Park et al. (Park, Y. J., Lee, M. Y., and Cho, S. I. ( 1992 ). “Fluorometholone,” J. Korean Chem. Soc. 36 , 812–817), C–H⋯O hydrogen bonds contribute to the crystal energy.

Gonzalez, Diana↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

Element- and Time-Resolved Measurements of Spin Dynamics Using X-ray Detected Ferromagnetic Resonance

Although XFMR experiments have been carried out at a number of synchrotron radiation facilities since 2004, only a few facilities currently have XFMR setups available for user operation. Here in this review, we mainly focus on recent developments and work that has been carried out using time-resolved XFMR at beamline 4.0.2 of the Advanced Light Source and at beamline I10 of the Diamond Light Source. The experimental setup and the sample holder used at beamline I10 and beamline 4.0.2, respectively, are shown in Figure 1. We will first introduce the working principle of XFMR and then provide examples of the capabilities of this technique. Finally, we will briefly describe an outlook for the future development of and new opportunities for XFMR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗

Demonstration of full-scale spatiotemporal diagnostics of solid-density plasmas driven by an ultra-short relativistic laser pulse using an X-ray free-electron laser

Understanding the complex plasma dynamics in ultra-intense relativistic laser–solid interactions is of fundamental importance for applications of laser–plasma-based particle accelerators, the creation of high-energy-density matter, understanding planetary science, and laser-driven fusion energy. However, experimental efforts in this regime have been limited by the lack of accessibility of over-critical densities and the poor spatiotemporal resolution of conventional diagnostics. Over the last decade, the advent of femtosecond brilliant hard X-ray free-electron lasers (XFELs) has opened new horizons to overcome these limitations. Here, for the first time, we present full-scale spatiotemporal measurements of solid-density plasma dynamics, including preplasma generation with tens of nanometer scale length driven by the leading edge of a relativistic laser pulse, ultrafast heating and ionization at the main pulse arrival, the laser-driven blast wave, and transient surface return current-induced compression dynamics up to hundreds of picoseconds after interaction. These observations are enabled by utilizing a novel combination of advanced X-ray diagnostics including small-angle X-ray scattering, resonant X-ray emission spectroscopy, and propagation-based X-ray phase-contrast imaging simultaneously at the European XFEL-HED beamline station.

Huang, Lingen [Helmholtz-Zentrum Dresden-Rossendor↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Design Considerations for Fermilab Multi-MW Proton Facility in the DUNE/LBNF era

Fermilab has submitted two Snowmass whitepapers on a future 2.4~MW upgrade for DUNE/LBNF featuring a 2 GeV extension of the PIP-II linac and the construction of a new rapid-cycling-synchrotron. This paper summarizes the relationship between these two scenarios, emphasizing the commonalities and tracing the differences to their original design questions. In addition to a high-level summary of the two 2.4~MW upgrade scenarios, there is a brief discussion of staging, beamline capabilities, subsequent upgrades, and relevant R&D. We are proposing a vigorous program to address various challenges associated with each scenario and to down-select the concept, most suitable to provide proton beams for years to come.

43 PARTICLE ACCELERATORS↗

Deep learning approaches to semantic segmentation of fatigue cracking within cyclically loaded nickel superalloy

Improvements to synchrotron-based micro-computed tomography scanning capabilities have gifted researchers the ability to characterize 4D material thermomechanical responses more thoroughly than ever before. These advancements, however, have brought about new challenges in analyzing the resulting deluge of data. We report on a nickel-based superalloy specimen imaged 26 times in-situ during cyclic loading at Argonne National Laboratory Advanced Photon Source beamline 1ID, in order to monitor crack growth within the microstructure. Therefore, several deep learning approaches which utilize convolutional neural networks are implemented to segment crack features from reconstructed tomography scans. U-Net architecture implementations are found to be especially effective, achieving IoU = 0.995 +/- 0.004 and Matthews correlation coefficient scores of Φ = 0.826 +/- 0.085. These advancements broaden possibilities for scientists seeking to automate segmentation analyses of similar large datasets.

36 MATERIALS SCIENCE↗

Study of interface reaction in a B 4 C/Cr mirror at elevated temperature using soft X-ray reflectivity

Boron carbide is a prominent material for high-brilliance synchrotron optics as it remains stable up to very high temperatures. The present study shows a significant change taking place at 550°C in the buried interface region formed between the Cr adhesive layer and the native oxide layer present on the silicon substrate. An in situ annealing study is carried out at the Indus-1 Reflectivity beamline from room temperature to 550°C (100°C steps). The studied sample is a mirror-like boron carbide thin film of 400 Å thickness deposited with an adhesive layer of 20 Å Cr on a silicon substrate. The corresponding changes in the film structure are recorded using angle-dependent soft X-ray reflectivity measurements carried out in the region of the boron K-edge after each annealing temperature. Analyses performed using the Parratt recursive formalism reveal that the top boron carbide layer remains intact but interface reactions take place in the buried Cr–SiO2 region. After 300°C the Cr layer diffuses towards the substrate. At higher temperatures of 500°C and 550°C the Cr reacts with the native oxide layer and tends to form a low-density compound of chromium oxysilicide (CrSiOx). Depth profiling of Si and Cr distributions obtained from secondary ion mass spectroscopy measurements corroborate the layer model obtained from the soft X-ray reflectivity analyses. Details of the interface reaction taking place near the substrate region of boron carbide/Cr sample are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ High-Temperature Synchrotron Diffraction Studies of (Fe,Cr,Al) 3 O 4 Spinels

The modeling of a loss-of-coolant-accident scenario involving nuclear fuels with FeCrAl cladding materials in consideration to replace a Zircaloy requires knowledge of the thermodynamics of oxidized structures. At temperatures higher than 1500 degrees C, oxidation of FeCrAl alloys forms (Fe,Cr,Al) 3 O 4 spinels. In situ high-energy X-ray diffraction in a conical nozzle levitator installed at beamline 6-ID-D of the APS was used to study the structural evolution of the oxides as a function of the temperature. Single-phase (spinel) and multiphase (spinel-corundum-FeAlO 3 ) regions are mapped as a function of the temperature for three different compositions of FeCrAl oxidation products. The thermal expansion coefficients and cation distribution in the spinel structure have been refined. The temperature at which complete melting of the fuel cladding is expected has been determined by the liquidus temperatures of the oxidized products to be between 1657 and 1834 degrees C in a 20% O 2 /Ar atmosphere using the cooling trace method. The liquidus temperature increases with increasing Al and Cr content in the spinel phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗