Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

Leak Location and Classification in the Space Shuttle Main Engine Nozzle by Infrared Testing

The Space Shuttle Main Engine (SSME) is composed of cooling tubes brazed to the inside of a conical structural jacket. Because of the geometry there are regions that can't be inspected for leaks using the bubble solution and low-pressure method. The temperature change due escaping gas is detectable on the surface of the nozzle under the correct conditions. The methods and results presented in this summary address the thermographic identification of leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute temperature change associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.

Russell, Samuel S.↗

Temperature effects in the modal phase shift of a weakly guiding fiber

Temperature may be determined by monitoring the modal phase shift of an optical fiber. We present the results of a numerical model that has been developed to calculate the phase shift of a weakly guiding optical fiber due to thermal strain. Whenever an optical fiber is subjected to temperature changes, the optical path length, the index of refraction and the propagation constants of each fiber mode change. In consequence, the modal phase term, beta(ln)L, of the fields is also modified. A relationship for the modal phase shift is presented. This relation is applied to both single mode and two-mode fibers in order to determine the sensitivity characteristics of fibers that are subjected to temperature changes.

Egalon, Claudio O.↗

Global trends of measured surface air temperature

The paper presents the results of surface air temperature measurements from available meteorological stations for the period of 1880-1985. It is shown that the network of meteorological stations is sufficient to yield reliable long-term, decadal, and interannual temperature changes for both the Northern Hemisphere and the Southern Hemisphere, despite the fact that most stations are located on the continents. The results indicate a global warming of about 0.5-0.7 C in the past century, with warming of similar magnitude in both hemispheres. A strong warming trend between 1965 and 1980 raised the global mean temperature in 1980 and 1981 to the highest level in the period of instrumental records. Selected graphs of the temperature change in each of the eight latitude zones are included.

Hansen, James↗

Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

Lee, Stuart M. C.↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Spectral variation in the microwave emissivity of the roughened seas

Recently acquired microwave data obtained from the NASA CV 990 research aircraft have yielded variation of sea surface emissivity as a function of various parameters. Data acquired at a wavelength of 1.5 cm, horizontal polarization, agree with data obtained earlier by Nordberg et al. and Hollinger at nadir and 50 deg viewing angles respectively; the ratio of brightness temperature change to wind speed change was found to be approximately 1 K per meter per second over a wind speed range of 5 to 26 meters per second. Combining these recent measurements with the earlier measurements, it is evident that microwave radiometry can be used as a remote-sensing anemometer over all wind speed ranges of interest. Data analysis revealed that for nadir-viewing instruments, the ratio of brightness temperature change to wind speed change was approximately constant for the 0.8-2.8 cm wavelength range, about three-quarters of that value at 6 cm, and nearly zero at 21 cm. A model is proposed that is consistent with observations.

Gloersen, P.↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device, phase 1

The development of a sensor capable of detecting temperature changes as a function of viscosity changes, was completed. This type of sensor, consisting of an orifice bridge circuit, resulted in a device with a threshold above internally generated noise of 0.8C (1.5F). Data were obtained using a noise free Freon source provided by an air pressurized bladder. Tests conducted to operate the sensor from a typical Freon centrifugal pump system employing an air bubble accumulator for noise attentuation disclosed the sensor could be used only to sense temperature changes greater than 3.3C (6F) because of the excessively noisy output. This is attributed to the high frequency-pressure fluctuations in the Freon supply to the sensor.

Thurston, T. S.↗

Unlocking large compressive strains in thin active elastocaloric layers

Elastocaloric cooling attracts broad interest and rapidly growing attention due to its potential for high efficiency and low environmental impact. While it is common knowledge that triggering reversible entropy and temperature changes with stress applied in compression prevents rapid failures of materials, realizing this regime in elastocaloric systems is highly challenging because nearly all geometries suited for efficient heat transfer are prone to buckling even under modest loads. This work describes a concept of a novel composite, where an active NiTi layer is embedded into a polymer support structure such that the elastocaloric material is entirely in compression when the assembly is subjected to bending. The active layer achieves 8.1 K temperature change at 2.5% compressive strain without buckling. After 10,000 cycles at 2% compressive strain, the composite maintains mechanical integrity without degradation of the elastocaloric effect. The results demonstrate that NiTi and, potentially, other elastocalorically active materials in geometries previously thought impossible can be successfully implemented in regenerative cooling systems operating in compression.

42 ENGINEERING↗

Isomeric effects on the reactivity of branched alkenes: An experimental and kinetic modeling study of methylbutenes

Here, a detailed experimental study of the low-to-intermediate temperature combustion of methylbutene isomers, i.e., branched C 5 alkenes, has been undertaken with multiple experimental facilities. Ignition delay times were measured at equivalence ratios 0.5–2.0, 685–1020 K and up to 45 bar condition from two rapid compression machines and showed slight deviation from an Arrhenius behavior for all three isomers, while their reactivity order differs as temperature changes. Sampled intermediates formed during the oxidation process of mixtures at 900–1150 K and 0.82 bar from a flow reactor and at 730 K and 20 bar from a rapid compression machine were analyzed using gas chromatography techniques. Trends in the formation and consumption of sampled intermediates were modeled using a kinetic model developed in this work for all three isomers. Rate of production and sensitivity analyses emphasize the role of double bond-specific reactions governing the global reactivity of these fuels. Additional studies of the addition reactions of HO 2 radicals to the double bond and to allylic radicals may improve the model performance.

2-Methyl-1-butene↗

Seasonal Changes in Titan's Surface Temperatures

Seasonal changes in Titan's surface brightness temperatures have been observed by Cassini in the thermal infrared. The Composite Infrared Spectrometer (CIRS) measured surface radiances at 19 micron in two time periods: one in late northern winter (Ls = 335d eg) and another centered on northern spring equinox (Ls = 0 deg). In both periods we constructed pole-to-pole maps of zonally averaged brightness temperatures corrected for effects of the atmosphere. Between late northern winter and northern spring equinox a shift occurred in the temperature distribution, characterized by a warming of approximately 0.5 K in the north and a cooling by about the same amount in the south. At equinox the polar surface temperatures were both near 91 K and the equator was 93.4 K. We measured a seasonal lag of delta Ls approximately 9 in the meridional surface temperature distribution, consistent with the post-equinox results of Voyager 1 as well as with predictions from general circulation modeling. A slightly elevated temperature is observed at 65 deg S in the relatively cloud-free zone between the mid-latitude and southern cloud regions.

Jennins, Donald E.↗

Interpreting the Operando XANES of Surface-Supported Subnanometer Clusters: When Fluxionality, Oxidation State, and Size Effect Fight.

X-ray absorption near edge structure (XANES) spectroscopy is widely used for operando catalyst characterization. We show that, for highly fluxional supported nanoclusters, the customary extraction of the oxidation state of the metal from the XANES data by fitting to the bulk standards is highly questionable. The XANES signatures as well as the apparent oxidation state for such clusters arise from a complex combination of many factors, and not only from the chemical composition in reaction conditions (e.g., oxygen content in oxidizing atmosphere). The thermally accessible isomerization and population of several structurally distinct cluster forms, cluster-support interaction, and intrinsic size effects all impact the metal oxidation state and XANES signal. We demonstrate this on copper oxide clusters with different compositions, Cu4Ox(x = 2-5) and Cu5Oy (y = 3, 5), deposited on amorphous alumina and ultrananocrystalline diamond, for which we computed the XANES spectra and compare the results to the experiment. We show in addition that fitting the experimental spectrum to calculated spectra of supported clusters can, in contrast, provide good agreement and insight into the spectrum-composition-structure relation. Experimental XANES interpreted using the proposed fitting scheme shows the partial reduction of Cu oxide clusters at rising temperatures, and pinpoints the specific stoichiometries that dominate in the ensemble of cluster states as the temperature changes.

Zandkarimi, Borna↗

A multi-model assessment of global freshwater temperature and thermoelectric power supply under climate change

Water temperature is a key abiotic factor influencing aquatic ecosystem health and the services provided to both nature and humans. Global water temperature models offer possibilities to improve our understanding of water temperature regimes, which is increasingly important against the backdrop of climate change. Yet, existing studies have predominantly relied on a single model, which can lead to an incomplete representation of uncertainty and potential biases, in addition to limited insight into the range of possible future conditions, which ultimately reduces the robustness of climate impact assessments. Here, we provide a comprehensive assessment of surface freshwater temperature changes from various river and lake models for both past conditions and under future scenarios of climate change. Global models consistently simulate that surface water temperatures are currently 0.5 °C–0.8 °C higher than at the turn of the century (i.e. 1981–2000), and that warming will extend and intensify with future global change throughout the 21st century. While the strength of warming is highly sensitive to the different water temperature models, emissions scenarios and global climate models, our multi-model ensemble shows a global average annual water temperature rise of between +1.3 °C and +4.1 °C by the end of the century. To illustrate a potential societal impact of our results, we evaluate how future changes in discharge and water temperature may affect existing thermoelectric power plants, estimating average annual reductions of 1.5%–6% in global usable capacity by the end of the century. However, with river water temperatures projected to exhibit more pronounced seasonal patterns in the future—especially under the more extreme climate change scenarios and during summer months in the Northern Hemisphere—intra-annual reductions in usable capacity can be much more severe. Given the challenges associated with (large-scale) adaptation to control water temperature regimes, strong climate change mitigation is crucial for minimising water temperature rises and its associated negative impacts on humankind and ecosystems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Magnetic ordering in Eu 2 In and Eu 2 Sn

Eu 2 In and Eu 2 Sn crystallize in the orthorhombic Co 2 Si-type structure (oP12, Pnma, No. 62) with In and Sn atoms occupying one 4c site and the Eu atoms filling two other 4c sites. Eu 2 In has a nearly ideal first-order magnetostructural transition (FOMT) at 55 K with a hysteresis of less than 0.1 K, a large entropy change and an adiabatic temperature change of 5.0 K in a field of 2 T. The anhysteretic nature of the FOMT is likely due to there being no change in cell symmetry and relatively small changes in the lattice parameters. There is no magnetostructural transition in Eu2Sn. In this work we present the results of powder neutron diffraction, magnetization, and Eu Mössbauer spectroscopy aimed to investigate the nature of magnetic order for both Eu 2 In and Eu 2 Sn. The Eu Mössbauer spectrum of Eu 2 In at 5 K shows two equal area components, consistent with Eu occupying two equal multiplicity crystallographic sites. However, the different hyperfine fields (B) of 27 T and 17 T suggest that the magnetic environments of the Eu moments on the two 4c sites are different. Neutron diffraction data at 2.5 K show that in Eu 2 In the order is ferromagnetic, with Eu moments on both Eu sites oriented parallel to the a-axis; moment values of 6.8 μB and 6.5 μB were found. For Eu 2 Sn measurements find two antiferromagnetic transitions, which are corroborated by neutron diffraction. Analysis of density-functional theory calculations shows negligible energy difference between differing magnetic configurations, indirectly supporting stability of multiple magnetic structures observed experimentally. While the transition at T N1 = 30 K corresponds to the formation of a simple k 1 = 0 antiferromagnetic structure with Eu-moments pointing along the b-axis, at T N2 = 13 K a coexisting second magnetic order with k 2 = [0, ½, ½] appears.

36 MATERIALS SCIENCE↗

Medium-temperature phase change material integration in domestic heat pump water heaters for improved thermal energy storage

In this review, we examine state-of-the-art developments in integrating phase change materials (PCMs) for thermal energy storage (TES) in domestic heat pump water heaters (HPWHs). The component design optimization and control optimization of HPWHs and TES are reviewed for insight into improving the thermal capacity and efficiency of a PCM-integrated HPWH. The state-of-the-art review is categorized by the stage of development of the PCM for deployment in HPWHs. To select appropriate PCMs for HPWHs, a six-factor down-selection process is used to determine the best material(s) for integration in HPWHs with appropriate heat exchanger design. Ultimately, food-grade PCMs appear to be the best candidate for integration of TES in domestic HPWHs because they are nontoxic, highly cyclable, and have heat transfer properties accommodable to water heating when integrated in a manner to overcome the thermal conductivity limitations of the material. A key parameter of water heating performance is thermal heating power of the PCM component, which is not often reported. Many studies report significant improvement in capacity and efficiency. Furthermore, many performance metrics are identified from the literature to quantify the system performance, but agreement across studies is not found. Unified energy factor and first hour rating performance tests are required for commercially available HPWHs, and these performance metrics could homogenize the literature. Ultimately, we find that select PCMs are ready for deployment with HPWHs for performance improvement, and component design and control optimizations are new avenues of research and development required for a commercially viable PCM-integrated HPWH system.

25 ENERGY STORAGE↗