Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic resolution imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Two-dimensional retrieval methods for ultrafast imaging of molecular structure using laser-induced electron diffraction

Molecular structural retrieval based on electron diffraction has been proposed to determine the atomic positions of molecules with sub-angstrom spatial and femtosecond temporal resolutions. Given its success on small molecular systems, in this work, we point out that the accuracy of structure retrieval is constrained by the availability of a wide range of experimental data in the momentum space in all molecular systems. To mitigate the limitations, for laser-induced electron diffraction, here we retrieve molecular structures using two-dimensional (energy and angle) electron momentum spectra in the laboratory frame for a number of small molecular systems, which have previously been studied with 1D methods. Compared to the conventional single-energy or single-angle analysis, our 2D methods effectively expand the momentum range of the measured data. Besides utilization of the 2D data, two complementary methods are developed for consistency check on the retrieved results. Further, the 2D nature of our methods also offers a way of estimating the error from retrieval, which has never been explored before. Comparing with results from prior experiments, our findings show evidence that our 2D methods outperform the conventional 1D methods. Paving the way to the retrieval of large molecular systems, in which their tunneling ionization rates are challenging to obtain, we estimate the error of using the isotropic model in place of including the orientation-dependent ionization rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nano-spectroscopy of excitons in atomically thin transition metal dichalcogenides

Abstract Excitons play a dominant role in the optoelectronic properties of atomically thin van der Waals (vdW) semiconductors. These excitons are amenable to on-demand engineering with diverse control knobs, including dielectric screening, interlayer hybridization, and moiré potentials. However, external stimuli frequently yield heterogeneous excitonic responses at the nano- and meso-scales, making their spatial characterization with conventional diffraction-limited optics a formidable task. Here, we use a scattering-type scanning near-field optical microscope (s-SNOM) to acquire exciton spectra in atomically thin transition metal dichalcogenide microcrystals with previously unattainable 20 nm resolution. Our nano-optical data revealed material- and stacking-dependent exciton spectra of MoSe 2 , WSe 2 , and their heterostructures. Furthermore, we extracted the complex dielectric function of these prototypical vdW semiconductors. s-SNOM hyperspectral images uncovered how the dielectric screening modifies excitons at length scales as short as few nanometers. This work paves the way towards understanding and manipulation of excitons in atomically thin layers at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward Discovering the Structure and Dynamics of the Sun-Interstellar Medium System (Los Alamos LDRD Report)

We have taken major steps toward developing the tools necessary to explore with unprecedented resolution the plasma structure and dynamics of the Sun-interstellar medium (ISM) interaction region, known as the heliosheath. We have applied a rigorous imaging technique known as Generalized Ridge Regression (GRR) to construct statistically robust sky maps of hydrogen energetic neutral atoms (ENAs) emanating from this region and detected by the Los Alamos-led IBEX-Hi ENA imager [1] on NASA’s Interstellar Boundary Explorer (IBEX) mission [2]. Our methods go far beyond the map reconstruction process currently applied by the IBEX Science Operations Center (ISOC), opening up the possibility of new discovery science with the IBEX data set and positioning LANL for a lead science role for the upcoming Interstellar Mapping and Acceleration Probe (IMAP) mission [3] for which LANL is providing two key experiments. We have successfully demonstrated that the new maps are higher resolution and are capable of revealing structures that are not presently resolveable in standard ISOC maps

58 GEOSCIENCES↗

Experimentally validated high-fidelity simulations of a liquid jet in supersonic crossflow

Here, utilizing recent advancements in computational schemes for compressible, multiphase flows, this work features a parametric study of a pure liquid jet in supersonic crossflow that involves simulating the atomization process for four values of momentum-flux ratio. These simulations are validated against experimental results measured with high-speed X-ray imaging, which confirm the accuracy of the numerical approach. Also, the effect of numerical resolution on some flow behavior is investigated, revealing convergence of the jet shape and surface instability wavelength. Analysis of the resulting sprays includes statistical descriptions of the liquid distribution, liquid structures created through breakup, interfacial instabilities, and dominant flow features. As the flowrate increases, the spray penetrates further, it becomes more disperse, and less liquid impacts the wall, but the droplet size distribution changes little. The wavelength of instabilities on the windward side of the jet diverges from measured trends in subsonic crossflows. In a visualization of the time-averaged flow, counter-rotating vortices are observed along the jet core and in the wake, affecting the process of primary atomization and early droplet trajectories.

42 ENGINEERING↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity-Map Imaging and Magnetic-Bottle Photoelectron Spectroscopy of [SeCCH] – : Electronic Properties and Spin–Orbit Splitting

In this work, the recently synthesized acetylide compound KSeCCH containing the main group element selenium within the novel and in crystalline form unprecedented [SeCCH] – anion was successfully investigated in the gas phase by high-resolution velocity-map imaging (VMI) and magnetic-bottle (MB) photoelectron spectroscopy coupled with an electrospray ionization source. Both VMI and MB spectra exhibited identical electron affinities (EA, 2.517 ± 0.002 eV), spin–orbit coupling (SOC) splittings (1492 ± 20 cm –1 ), and Se–C stretching frequencies (573 ± 20 cm –1 ) of the corresponding neutral tetra-atomic radical [SeCCH] • with the VMI spectrum possessing six times higher spectral resolution compared with the MB spectrum. These experimental values were well reproduced by calculations at the CCSD(T) level, in which both the isolated [SeCCH] – anion and the [SeCCH] • radical adopted linear geometries. The simulated spectra based on the calculated Franck–Condon factors, the SOC splitting, and the experimental line width matched well with the measured spectra. Furthermore, comparisons of the EA and SOC splitting values with the previously reported isolobal species [SeCN] • are also made and discussed. The decrease in the EA and SOC splitting of [SeCCH] • is ascribed to the differences in the electronegativities between C and N atoms as well as the electron density on the Se atom in its singly occupied molecular orbital (SOMO).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale imaging of Gilbert damping using signal amplitude mapping

Ferromagnetic resonance force microscopy (FMRFM) is a powerful scanned probe technique that uses sub-micrometer-scale, spatially localized standing spin wave modes (LMs) to perform local ferromagnetic resonance (FMR) measurements. In this work, we show the spatially resolved imaging of Gilbert damping in a ferromagnetic material (FM) using FMRFM. Typically damping is measured from the FMR linewidth. We demonstrate an approach to image the spatial variation of Gilbert damping utilizing the LM resonance peak height to measure the LM resonance cone angle. This approach enables determination of damping through field-swept FMRFM at a single excitation frequency. The extreme force sensitivity of similar to 2 fN at room temperature can resolve changes of Gilbert damping as small as ~2 x 10 -4 at 2GHz, corresponding to ~0.16Oe in FMR linewidth resolution. This high sensitivity, high spatial resolution, and single frequency imaging of Gilbert damping creates the opportunity to study spin interactions at the interface between an insulating FM and a small volume of nonmagnetic material such as atomically thin two-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Toward Å-fs-meV Resolution in Electron Microscopy: Systematic Simulation of the Temporal Spread of Single-Electron Packets

Though efforts to improve the temporal resolution of transmission electron microscopes (TEMs) have waxed and waned for decades, with relatively recent advances routinely reaching sub-picosecond scales, fundamental and practical challenges have hindered the advance of combined Å-fs-meV resolutions, particularly for core-loss spectroscopy and real-space imaging. This is due in no small part to the complexity of the approach required to access timescales upon which electrons, atoms, molecules, and materials first begin to respond and transform – attoseconds to picoseconds. Here we present part of a larger effort devoted to systematically mapping the instrument parameter space of a TEM modified to reach ultrafast timescales. With General Particle Tracer, we studied the statistical temporal distributions of single-electron packets as a function of various fs pulsed-laser parameters and electron-gun configurations and fields for the exact architecture and dimensions of a Thermo Fisher Tecnai Femto ultrafast electron microscope. We focused on easily-adjustable parameters, such as laser pulse duration, laser spot size, photon energy, Wehnelt aperture diameter, and photocathode size. In addition to establishing trends and dispersion behaviors, we identify regimes within which packet duration can be 100s of fs and approach the 300-fs laser limit employed here. Overall, the results provide a detailed picture of the temporal behavior of single-electron packets in the Tecnai Femto gun region, forming the initial contribution of a larger effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging real-space flat band localization in kagome magnet FeSn

Kagome lattices host flat bands due to their frustrated lattice geometry, which leads to destructive quantum interference of electron wave functions. Here, we report imaging of the kagome flat band localization in real-space using scanning tunneling microscopy. We identify both the Fe 3 Sn kagome lattice layer and the Sn 2 honeycomb layer with atomic resolution in kagome antiferromagnet FeSn. On the Fe 3 Sn lattice, at the flat band energy determined by the angle resolved photoemission spectroscopy, tunneling spectroscopy detects an unusual state localized uniquely at the Fe kagome lattice network. We further show that the vectorial in-plane magnetic field manipulates the spatial anisotropy of the localization state within each kagome unit cell. Our results are consistent with the real-space flat band localization in the magnetic kagome lattice. We further discuss the magnetic tuning of flat band localization under the spin–orbit coupled magnetic kagome lattice model.

36 MATERIALS SCIENCE↗

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING↗

Scalable Nanoimprint Manufacturing of Functional Multilayer Metasurface Devices

Optical metasurfaces, consisting of subwavelength-scale meta-atom arrays, hold great promise of overcoming the fundamental limitations of conventional optics. Due to their structural complexity, metasurfaces usually require high-resolution yet slow and expensive fabrication processes. Here, using a metasurface polarimetric imaging device as an example, the photonic structures and the Nanoimprint lithography (NIL) processes are designed, creating two separate NIL molds over a patterning area of > 20 mm2 with designed Moiré alignment markers by electron-beam writing, and further subsequently integrate silicon and aluminum metasurface structures on a chip. Uniquely, the silicon and aluminum metasurfaces are fabricated by using the nanolithography and 3D pattern-transfer capabilities of NIL, respectively, achieving nanometer-scale linewidth uniformity, sub-200 nm translational overlay accuracy, and <0.017 rotational alignment error while significantly reducing fabrication complexity and surface roughness. Here, the micro-sized multilayer metasurfaces have high circular polarization extinction ratios as large as ≈20 and ≈80 in blue and red wavelengths. Further, the metasurface chip-integrated CMOS imager demonstrates high accuracy in broad-band, full Stokes parameter analysis in the visible wavelength ranges and single-shot polarimetric imaging. This novel, NIL-based, multilayered nanomanufacturing approach is applicable to the scalable production of large-area functional structures for ultra-compact optic, electronic, and quantum devices.

36 MATERIALS SCIENCE↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

Spectral and polarization based imaging in deep-ultraviolet excited photoelectron microscopy

Using photoelectron emission microscopy, nanoscale spectral imaging of atomically thin MoS2 buried between Al2O3 and SiO2 is achieved by monitoring the wavelength and polarization dependence of the photoelectron signal excited by deep-ultraviolet light. Although photons induce the photoemission, images can exhibit resolutions below the photon wavelength as electrons sense the response. To validate this concept, the dependence of photoemission yield on the wavelength and polarization of the exciting light was first measured and then compared to simulations of the optical response quantified with classical optical theory. A close correlation between experiment and theory indicates that photoemission probes the optical interaction of UV-light with the material stack directly. The utility of this probe is then demonstrated when both the spectral and polarization dependence of photoemission observe spatial variation consistent with grains and defects in buried MoS2. Taken together, these new modalities of photoelectron microscopy allow mapping of optical property variation at length scales unobtainable with conventional light-based microscopy.

Beechem, Thomas E. (ORCID:0000000275360719)↗

Aberration-corrected STEM imaging of 2D materials: Artifacts and practical applications of threefold astigmatism

High-resolution scanning transmission electron microscopy (HR-STEM) with spherical aberration correction enables researchers to peer into two-dimensional (2D) materials and correlate the material properties with those of single atoms. The maximum intensity of corrected electron beam is confined in the area having sub-angstrom size. Meanwhile, the residual threefold astigmatism of the electron probe implies a triangular shape distribution of the intensity, whereas its tails overlap and thus interact with several atomic species simultaneously. The result is the resonant modulation of contrast that interferes the determination of phase transition of 2D materials. Here, we theoretically reveal and experimentally determine the origin of resonant modulation of contrast and its unintended impact on violating the power-law dependence of contrast on coordination modes between transition metal and chalcogenide atoms. The finding illuminates the correlation between atomic contrast, spatially inequivalent chalcogenide orientation, and residual threefold astigmatism on determining the atomic structure of emerging 2D materials.

36 MATERIALS SCIENCE↗

High Cooperativity Using a Confocal-Cavity–QED Microscope

Cavity quantum electrodynamics (QED) with cooperativity far greater than unity enables high-fidelity quantum sensing and information processing. The high-cooperativity regime is often reached through the use of short single-mode resonators. More complicated multimode resonators, such as the near-confocal optical Fabry-Pérot cavity, can provide intracavity atomic imaging in addition to high cooperativity. This capability has recently proved important for exploring quantum many-body physics in the driven-dissipative setting. In this work, we show that a confocal-cavity–QED microscope can realize cooperativity in excess of 110. This cooperativity is on par with the very best single-mode cavities (which are far shorter) and 21 times greater than single-mode resonators of similar length and mirror radii. The 1.7-µm imaging resolution is naturally identical to the photon-mediated interaction range. We measure these quantities by determining the threshold of cavity superradiance when small optically tweezed BoseEinstein condensates are pumped at various intracavity locations. Transmission measurements of an ex situ cavity corroborate these results. We provide a theoretical description that shows how cooperativity enhancement arises from the dispersive coupling to the atoms of many near-degenerate modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Imaging Secondary Electron Emission from a Single Atomic Layer

Graphene-based devices hold promise for a wide range of technological applications. Yet characterizing the structure and the electrical properties of a material that is only one atomic layer thick still poses technical challenges. Recent investigations indicate that secondary-electron electron-beam-induced current (SE-EBIC) imaging can reveal subtle details regarding electrical conductivity and electron transport with high spatial resolution. Here, it is shown that the SEEBIC imaging mode can be used to detect suspended single layers of graphene and distinguish between different numbers of layers. Pristine and contaminated areas of graphene are also compared to show that pristine graphene exhibits a substantially lower SE yield than contaminated regions. In conclusion, this SEEBIC imaging mode may provide valuable information for the engineering of surface coatings where SE yield is a priority.

36 MATERIALS SCIENCE↗