Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Anisotropic induced Compton scattering - Constraints on models of active galactic nuclei

A model for nonlinear radiative transfer on a lattice is used to explore observational signatures of anisotropic induced Compton scattering. Ways in which an intense beam of radiation may be altered in passing through a slab of plasma that is optically thin to spontaneous Thomson scattering are explained. A numerical approach to induced Compton scattering which involves solving the equations of nonlinear transfer on a lattice is described. Results of calculations for some simple geometrical configurations (spheres, disks, cylindrical 'jets', etc.) are presented. Some possible applications of these results to the interpretation of actual data on compact radio sources are outlined, and the FIR spectra of AGN are considered.

Coppi, P.↗

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Whistler-mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the Plasma Diagnostics Package (PDP) performed a fly-around of the Shuttle at distances of up to 300 meters while an electron beam was being ejected from the Shuttle. A magnetic conjunction of the Shuttle and the PDP while the electron gun was operating in a steady (DC) mode is discussed. During this conjunction, the PDP detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the beam. Ray-path calculations show that the shape of the funnel can be accounted for by whistler-mode waves propagating near the resonance cone. Because the beam and waves are propagating in the same direction, the radiation must be produced by a Landau interaction with the beam. Other types of waves generated by the beam are also described.

Gurnett, D. A.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

Is Mini Beam Ready for Human Trials? Results of Randomized Study of Treating De-Novo Brain Tumors in Canines Using Linear Accelerator Generated Mini Beams

The main challenge in treating malignant brain neoplasms lies in eradicating the tumor while minimizing treatmentrelated damage. Conventional radiation treatments are associated with considerable side effects. Synchrotron generated micro-beam radiation (SMBRT) has shown to preserve brain architecture while killing tumor cells, however physical characteristics and limited facility access restrict its use. We have created a new clinical device which produces mini beams on a linear accelerator, to provide a new type of treatment called mini-beam radiation therapy (MBRT). The objective of this study is to compare the treatment outcomes of linear accelerator based MBRT versus standard radiation treatment (SRT), to evaluate the tumor response and the treatment-related changes in the normal brain with respect to each treatment type. Pet dogs with de-novo brain tumors were accrued for treatment. Dogs were randomized between standard fractionated stereotactic (9 Gy in 3 fractions) radiation treatment vs. a single fraction of MBRT (26 Gy mean dose). Dogs were monitored after treatment for clinical assessment and imaging. When the dogs were euthanized, a veterinary pathologist assessed the radiation changes and tumor response. We accrued 16 dogs, 8 dogs in each treatment arm. In the MBRT arm, 71% dogs achieved complete pathological remission. The radiation-related changes were all confined to the target region. Structural damage was not observed in the beam path outside of the target region. In contrast, none of the dogs in control group achieved remission and the treatment related damage was more extensive. Therapeutic superiority was observed with MBRT, including both tumor control and the normal structural preservation. The MBRT findings are suggestive of an immune related mechanism which is absent in standard treatment. These findings together with the widespread availability of clinical linear accelerators make MBRT a promising research topic to explore further treatment and clinical trial opportunities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SI IV Resonance Line Emission during Solar Flares: Non-LTE, Non-equilibrium, Radiation Transfer Simulations

The Interface Region Imaging Spectrograph routinely observes the Si IV resonance lines. When analyzing quiescent observations of these lines, it has typically been assumed that they form under optically thin conditions. This is likely valid for the quiescent Sun, but this assumption has also been applied to the more extreme flaring scenario. We used 36 electron-beam-driven radiation hydrodynamic solar flare simulations, computed using the RADYN code, to probe the validity of this assumption. Using these simulated atmospheres, we solved the radiation transfer equations to obtain the non-LTE, nonequilibrium populations, line profiles, and opacities for a model silicon atom, including charge exchange processes. This was achieved using the "minority species" version of RADYN. The inclusion of charge exchange resulted in a substantial fraction of Si IV at cooler temperatures than those predicted by ionization equilibrium. All simulations with an injected energy flux F> 5 x 10(exp 10) erg cm(exp -2) s(exp -1) resulted in optical depth effects on the Si IV emission, with differences in both intensity and line shape compared to the optically thin calculation. Weaker flares (down to F ~ 10(exp 9) erg cm(exp -2) s(exp -1)) also resulted in Si IV emission forming under optically thick conditions, depending on the other beam parameters. When opacity was significant, the atmospheres generally had column masses in excess of 5 x 10-6 g cm-2 over the temperature range 40-100 kK, and the Si IV formation temperatures were between 30 and 60 kK. We urge caution when analyzing Si IV flare observations, or when computing synthetic emission without performing a full radiation transfer calculation.

Kerr, Graham S.↗

A lunar rover powered by an orbiting laser diode array

A conceptual design of a high-power, long-duration lunar rover powered by a laser beam is proposed. The laser transmitter in lunar orbit consists of an SP-100 nuclear reactor prime power source providing 100 kW of electricity to a laser array that emits 50 kW of laser radiation. The laser radiation is beamed to the lunar surface where it is received by a GaAlAs solid-state, laser-to-electric converter. This converter provides 22 kW of electrical power to the rover vehicle for science, locomotion, and crew needs. The mass of the laser transmitter is approximately 5000 kg, whereas the mass of the rover power supply is 520 kg. The rover power unit is significantly less massive than alternative rover power units.

De Young, R. J.↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

Particulate sizes from polarization measurements

Radiation measurements from a ground based polarimeter were used to infer the optical properties of atmospheric particles. The inherent nonunigueness in model calculations is discussed. The inverse problem in atmospheric optics is described, along with incident and emergent beams. Emergent radiation was calculated for all possible particulate distributions, and results were catalogued.

Kuriyan, J. G.↗

Alterations in dose and lineal energy spectra under different shieldings in the Los Alamos high-energy neutron field

Nuclear interactions of space radiation with shielding materials result in alterations in dose and lineal energy spectra that depend on the specific elemental composition, density and thickness of the material. The shielding characteristics of materials have been studied using charged-particle beams and radiation transport models by examining the risk reduction using the conventional dose-equivalent approach. Secondary neutrons contribute a significant fraction of the total radiation exposure in space. An experiment to study the changes in dose and lineal energy spectra by shielding materials was carried out at the Los Alamos Nuclear Science Center neutron facility. In the energy range of about 2 to 200 MeV, this neutron spectrum is similar in shape within a factor of about 2 to the spectrum expected in the International Space Station habitable modules. It is shown that with a shielding thickness of about 5 g cm(-2), the conventional radiation risk increases, in some cases by as much as a factor of 2, but decreases with thicknesses of about of 20 g cm(-2). This suggests that care must be taken in evaluating the shielding effectiveness of a given material by including both the charged-particle and neutron components of space radiation.

NASA Discipline Radiation Health↗

Remote balance weighs accurately amid high radiation

Commercial beam-type balance, modified and outfitted with electronic controls and digital readout, can be remotely controlled for use in high radiation environments. This allows accurate weighing of breeder-reactor fuel pieces when they are radioactively hot.

Eggenberger, D. N.↗

Considerations for high accuracy radiation efficiency measurements for the Solar Power Satellite (SPS) subarrays

The relatively large apertures to be used in SPS, small half-power beamwidths, and the desire to accurately quantify antenna performance dictate the requirement for specialized measurements techniques. Objectives include the following: (1) For 10-meter square subarray panels, quantify considerations for measuring power in the transmit beam and radiation efficiency to + or - 1 percent (+ or - 0.04 dB) accuracy. (2) Evaluate measurement performance potential of far-field elevated and ground reflection ranges and near-field techniques. (3) Identify the state-of-the-art of critical components and/or unique facilities required. (4) Perform relative cost, complexity and performance tradeoffs for techniques capable of achieving accuracy objectives. the precision required by the techniques discussed below are not obtained by current methods which are capable of + or - 10 percent (+ or - dB) performance. In virtually every area associated with these planned measurements, advances in state-of-the-art are required.

Kozakoff, D. J.↗

Electron scattering and the distances to cluster cooling flows

Cluster cooling flows have electron-scattering optical depths which are estimated to be about 0.01. Many of the cluster-dominant galaxies centered in cluster cooling flows have active nuclei, and about 1 percent of the luminosity from the active nuclei should appear as diffuse, scattered radiation. It is shown here that detection of this scattered radiation at radio wavelengths can provide a measure of the distance to the cluster that is independent of the Hubble constant. Observations of the scattered surface brightness profile can also be used to test for clumpiness in the gas, for variations in the central radio source on time scales less than 100,000 yr, and for the degree of beaming of radiation from the central source.

Wise, Michael W.↗