Search NASA⌕ Search

SEARCH · Search NASA

Results for “Base heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Investigation of post-injection strategies for diesel engine Catalyst Heating Operation using a vapor-liquid-equilibrium-based spray model

Most multidimensional engine simulations spend much time solving for non-equilibrium spray dynamics (atomization, collision, vaporization). However, their accuracy is limited by significant grid dependency, and the need for extensive calibration. This is critical for modeling cold-start diesel fuel post injections, which occur at low temperatures and pressures, far from typical model validation ranges. At the same time, resolving micron-scale spray phenomena would render full Eulerian multiphase calculations prohibitive. In this study, an improved phase equilibrium based approach was implemented and assessed for simulating diesel catalyst heating operation strategies. A phase equilibrium solver based on the model by Yue and Reitz [1] was implemented: a fully multiphase CFD solver is employed with an engineering-size engine grid, and fuel injection is modeled using the standard Lagrangian parcels approach. Mass and energy from the liquid parcels are released to the Eulerian multiphase mixture according to an equilibrium-based liquid jet model. An improved phase equilibrium solver was developed to handle large real-gas mixtures such as those from accurate chemical kinetics mechanisms. The liquid-jet model was improved such that momentum transfer to the Eulerian solver better reproduces the physical spray jet structure. Validation of liquid/vapor penetration predictions showed that the model yields accurate results with very limited tuning and low sensitivity to the few calibration constants. In-cylinder simulations of diesel catalyst heating operation strategies showed that capturing spray structure is paramount when short, transient injection pulses and low temperatures are present. Furthermore, the EP model provides improved predictions of post-injection spray structure and ignitability, while conventional spray modeling does not capture the increase of liquid penetration during the expansion stroke. Finally, the only important EP model calibration constant, Cliq, does not affect momentum transfer, but it changes the local charge cooling distribution through the local energy transfer, which makes it candidate to additional research. The results confirm that non-equilibrium spray processes do not need to be resolved in engineering simulations of high-pressure diesel sprays.

42 ENGINEERING↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Current-Activated Reactive Ultrafast Joining (CARUJ)

We have demonstrated Current Activated Reactive Ultrafast Joining (CARUJ) as a novel approach for rapid fabrication of similar and dissimilar materials, such as ceramic-ceramic and ceramic-metal joint assemblies. The CARUJ technology utilizes resistive heating of carbon-based materials to apply localized heat at, (through or around) joint zones at rates of 10 1 -10 2 ˚C/min, enabling joining at time scales considerably shorter (several minutes as opposed to hours) than conventional approaches for similar systems. Herein, we present our findings while evaluating the CARUJ concept. Three methods of heat application were evaluated: (i) using carbon joule heating elements to apply heat directly through the joint interface; (ii) using flexible joule heating elements to locally apply heat around the assembly interface; and (iii) non-contact heating of the joint assembly using inductive power. Schemes (ii) and (iii) proved to be the most effective in producing mechanically sound reliable joints. We demonstrated single-step fabrication of dense SiC-SiC joints with a Si- SiC interface using minimal pressure (1–2 MPa) in under 30 minutes. Measured average joint strengths of about 15 MPa are initially achieved for joined bodies when tested in single lap offset (SLO) compressive shear, while tuning of the interfacial composition along with a reduction in interlayer thickness, results in improved joint strengths of approximately 43 MPa. We further demonstrated SiC-SiC joining using Active Brazing Alloys (ABAs) proof of concept joining of tubular geometries. The versatility of CARUJ is demonstrated by utilizing non-contact heating via induction, to join dissimilar materials systems of SiC, SS316 and MAX phase ceramics with ABA interlayers. The localized and rapid heat application realizes a versatile material joining technique that can be extended for joining components at the plant site.

36 MATERIALS SCIENCE↗

Characterization and Scaling of Forced Convective Swirl in Sinusoidal Wavy-Plate-Fin Cores of Compact Heat Exchangers

The characterization and scaling of the thermal-hydraulic performance in wavy plate-fin compact heat exchanger cores, based on the understanding of the physical phenomena and heat transfer enhancement mechanism is delineated. Experimental data are presented for forced convection in air (Pr = 0.71) with flow rates in the range 50 ≤ Re ≤ 4000. A variety of wavy-fin cores that span viable applications, with geometrical attributes described by the cross section aspect ratio α (ratio of fin spacing to height), fin corrugation aspect ratio γ (ratio of 2× corrugation amplitude to wave pitch), and fin spacing ratio ζ (ratio of fin spacing to wave pitch), are considered. To characterize and correlate the vortex-flow mixing in interfin spaces, a Swirl number Sw is introduced from the balance of viscous, inertial and centrifugal forces. It is shown that the laminar, transitional and turbulent flow regimes can be explicitly identified by this Swirl number. Based on the experimental results and extended analysis, new correlations for Fanning friction factor f and Colburn factor j are developed with Sw, α, γ, and ζ as scaling parameters. Requisite expressions are devised by a superposition of both enhancement components due to the corrugated surface area enlargement and induced swirl flow field, and they are combined to cover the laminar, transitional and turbulent regimes by the method of asymptotic matching. The resulting generalized correlations are further shown to predict all available experimental data for f and j factors to within ±20% and ±15%, respectively.

42 ENGINEERING↗

Development of pebble-based extruded carbon rods for extreme plasma heat flux environments

This work presents first experiments toward the development of continuously renewable (extrudable) pebble-based carbon rods for use as plasma-facing components in extreme steady-state plasma flux environments. The primary envisioned application of this work is a first wall that can survive long-term in future magnetic fusion power reactors while also improving recovery of the reactor fuel (tritium and deuterium atoms). Bench tests applying extreme steady-state front-surface heat loads of up to 50 MW/m 2 are presented. Continuous pebble rod front-surface recession and intact pebble recovery are successfully demonstrated, at a rate of order 0.2 cm/s. Numerical simulations of the pebble rod front-surface recession are able to match observations reasonably well, indicating that the recession mechanism can be understood as occurring due to pebble thermal expansion and resulting shock and cracking of the inter-pebble binder. Tests of the pebble rod extrusion demonstrate that friction between the rods and the stainless-steel extrusion channel is tolerably low (<50 N for the expected channel length) over a wide range of temperatures. Front-surface outgassing rates below 1000 Torr L/s/m 2 are achieved, believed to be sufficiently low for use in magnetic fusion reactors. In conclusion, initial parametric scans over pebble rod size and binder fraction to vary front-surface recession rates are presented.

36 MATERIALS SCIENCE↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Development of a web-based screening tool for ground source heat pump applications

Ground source heat pump (GSHP) technology has great potential to help the nation meet its energy and decarbonization goals, but several barriers hinder the wide application of GSHP. Important barriers include the lack of a coherent toolset for analyzing the technical feasibility and economic viability of the GSHP application. The current design and analysis methods are ineffective and require significant expertise to apply. Although building energy modeling is increasingly important in designing buildings, the tools for GSHP modeling and simulation are lacking. A web-based free-to-use tool is being developed for quick techno-economic analysis of GSHP applications in nearly any building in the United States. This tool is enabled by improvements in the calculation methodology to allow rapid sizing of borehole configurations that provide significant cost savings. The screening tool currently uses US Department of Energy (DOE) prototype building models and an extended g-function library to size ground heat exchangers and simulate the performance of GSHP systems. The team is integrating with DOE's Oak Ridge National Laboratory's AutoBEM program to automatically create a building model based on user inputs. This paper introduces the structure, components, features, and results of the web-based screening tool for GSHP applications. Future directions for further developing the tool are also discussed.

Liu, Xiaobing↗

Characterization of build parameters and microstructure in low heat input WAAM of Ni-based superalloy Haynes 282

Conference paper for 2024 10th International Conference on Advances in Materials, Manufacturing &amp; Repair for Power Plants. Ni-based superalloy Haynes 282 is a prime candidate for advanced power generation systems due to its superior fabricability, weldability, and high-temperature performance. Additive manufacturing offers potential cost and time savings for gas turbine components. Wire-arc direct energy deposition can create large components but often requires post-processing treatments, such as hot isostatic pressing (HIP), to address porosity. This study explores a low heat-input, high deposition rate GMAW process to achieve fully dense Haynes 282 without HIP. Twenty-one blocks were deposited, varying travel and wire feed speeds. Initial analysis (visual inspection, microstructural examination, and CT) revealed the impact of build parameters on internal porosity and defects. Scanning electron microscopy provided insights into structural heterogeneity and microstructural properties. Related journal article can be found at https://doi.org/10.31399/asm.cp.am-epri-2024p0001.

Adam, Benjamin↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗