Search NASA⌕ Search

SEARCH · Search NASA

Results for “Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Steady-State Thermal-Hydraulic Analysis of the LEU-Fueled Dalat Nuclear Research Reactor

This paper presents results of steady-state thermal-hydraulic analysis for the designed working core of the Dalat Nuclear Research Reactor (DNRR) using the PLTEMP/ANL code. The core was designed to be loaded with 92 low-enriched uranium (LEU) VVR-M2 fuel bundles (FBs) and 12 beryllium rods surrounding a neutron trap at the core center, for replacement of the previous core with 104 high-enriched uranium (HEU) VVR-M2 FBs. Before using this code for thermohydraulic analysis of the designed LEU working core, it was validated by comparing calculation results with experimental data collected from the HEU working core of the DNRR. The discrepancy between calculated results and measured data was at the maximum about 0.8°C and 1.5°C of fuel cladding and outlet coolant temperatures, respectively. In the design calculation, thermohydraulic safety was confirmed through evaluation of the fuel cladding and coolant temperatures, as well as of other safety parameters such as Departure from Nucleate Boiling Ratio (DNBR) and Onset of Nucleate Boiling Ratio (ONBR). The calculation results showed that, in normal operation conditions at full nominal thermal power of 500 kW without uncertainty parameters, the maximum fuel cladding temperature of the hottest FB was about 90.4°C, which is lower than its limit value of 103°C, the minimum DNBR was 32.0, which is much higher than the recommended value of 1.5, and the minimum ONBR was 1.43, which is higher than the recommended value of 1.4 for VVR-M2 LEU fuel type. When the global and local hot channel factors were taken into account, the maximum temperature of fuel cladding at the hottest FB was about 98.4 °C, for global only, and 114.3°C, for global together with local hot channel factors. The calculation results confirm the safety operation of the designed LEU core loaded with 92 fresh VVR-M2 FBs.

Nguyen, Kien-Cuong↗

Investigations on the Thermal-hydraulic Behavior of Accident Tolerant Fuel Cladding Materials

Since the 2011 Fukushima accident, significant research has been devoted to developing accident-tolerant fuel (ATF) cladding materials. These investigations have mostly focused on the ability to resist runaway steam oxidation and retain mechanical strength and structural integrity under thermal shocks. However, much remains unknown about the materials’ thermal-hydraulic behavior, particularly under light-water reactor (LWR) operating conditions. Two phenomena that determine safety margins in both normal and off-normal operating conditions - i.e., the critical heat flux (CHF) and Leidenfrost point (LFP) temperature - have not been investigated thoroughly for ATF materials. Surface properties, such as wettability and roughness, are known to influence pool and flow boiling CHF, as well as the LFP temperature. However, little is known about the surface wettability of ATF materials, particularly at LWR pressure and temperature. Little has been done on flow-boiling CHF and quenching heat transfer, especially for droplet quenching. Nonetheless, it is known that CHF in transient conditions, e.g., an exponentially escalating power transient, can be significantly different from that expected in steady-state operation. Very few studies have investigated transient CHF, either on ATF materials or under LWR pressure and temperature. The thorough understanding of transient CHF under prototypical reactor conditions will benefit not only the deployment of ATF but also the upcoming national efforts to study transient ATF behavior in the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory. In summary, as a part of ATF development efforts, there is an urgent need to understand how and how much these materials may affect two-phase heat transfer phenomena in nuclear reactor conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam. Thirty potential antifoams were tested as part of this study. A series of tests were developed to help screen out ineffective alternatives including: 1. Spreading testing of superspreaders, 2. Foam column testing with physical simulants, 3. Boiling testing with physical and chemical simulants, 4. Days-only Sludge Receipt and Adjustment Tank (SRAT) process simulations with sludge (containing noble metals and mercury), Precipitate Reactor Feed Tank (PRFT), and Slurry Mix Evaporator Feed Tank (SEFT) simulants in the RC1 Reaction Calorimeter (purchased for antifoam testing), and 5. Around-the-clock SRAT and Slurry Mix Evaporator (SME) process simulations with sludge(containing noble metals and mercury), PRFT, and SEFT simulants in the RC1 Reaction Calorimeter. Evonik Surfynol® MD20, a commercially available defoamer, was relatively effective in controlling foam, while remaining chemically stable in SRAT and SME processing across the pH range of 4 to 13. No degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. In nitric-glycolic acid flowsheet testing, 250 mg/kg Evonik Surfynol® MD20 was needed for foam control compared to 1,625 mg/kg for Antifoam 747, DWPF’s current antifoam. In nitric-formic acid flowsheet testing, 1,125 mg/kg of Evonik Surfynol® MD20 was needed to control foam throughout the SRAT and SME cycles. The commercially available superspreader Momentive™ Y-17112 was even more effective than Evonik Surfynol® MD20 as both a defoamer and an antifoam. Not only was the foam destroyed upon addition but also was less persistent between additions. It was the most effective antifoam in testing using both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. In nitric-glycolic acid flowsheet testing, only 100 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. In nitric-formic acid flowsheet testing, 300 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. Momentive™ Y-17112 is also resistant to hydrolysis as demonstrated by its chemical stability in SRAT and SME processing across the pH range of 4 to 13 and lack of degradation products in offgas or condensate. Both candidates were effective as potential replacements for Antifoam 747, with Y-17112 demonstrating superior foam control. During nitric-glycolic flowsheet testing 50% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. During nitric-formic flowsheet testing 75% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. Foam remediated with Momentive™ Y-17112 was less persistent throughout testing. In addition, no degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. Based on this testing, Momentive™ Y-17112 is clearly superior to Evonik Surfynol® MD20 and Antifoam 747, especially for the nitric-formic acid flowsheet processing; it is recommended that Momentive™ Y-17112 replace Antifoam 747 in DWPF. An antifoam addition strategy is recommended for both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. Implementation of Momentive™ Y-17112 is expected to decrease SRAT and SME boiling times by up to 50%, eliminate the issues resulting from Antifoam 747 degradation products, and minimize foamovers. To validate the effectiveness of these defoaming agents, SRNL recommends irradiation of a SRAT or SME product simulant containing fresh antifoam. The goal of this testing is to determine whether the irradiation causes decomposition of the antifoam that would make it less effective or produce new species in the offgas or slurry. This testing began in April 2020. An evaluation should be completed to determine the thermolytic hydrogen and methane generation rate in downstream equipment, including the High-Level Waste evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Overview of the State-of-the-Art Reactor Consequence Uncertainty Assessment Accident Progression Insights

The U.S. Nuclear Regulatory Commission (NRC) with Sandia National Laboratories (Sandia) have completed three uncertainty analyses (UAs) as part of the State-of-the-Art Reactor Consequence Analyses (SOARCA) program. The SOARCA UAs included an integrated evaluation of uncertainty in accident progression, radiological release, and offsite health consequence projections. The UA for Peach Bottom, a boiling-water reactor (BWR) with a Mark I containment located in the State of Pennsylvania, analyzed the unmitigated long-term station blackout SOARCA scenario. The UA for Sequoyah, a 4-loop Westinghouse pressurized-water reactor (PWR) located in the State of Tennessee, analyzed the unmitigated short-term station blackout SOARCA scenario, with a focus on issues unique to the ice condenser containment and the potential for early containment failure due to hydrogen deflagration. The UA for Surry, a 3-loop Westinghouse PWR with a sub-atmospheric large dry containment located in the State of Virginia, analyzed the unmitigated short-term station blackout SOARCA scenario including the potential for thermally-induced steam-generator tube rupture. These three UAs are currently documented in three NUREG/CR reports. This report provides input to planned NRC documentation on the insights and findings from the SOARCA UA program. The purpose of the summary report is to provide a useful reference for regulatory applications that require the evaluation of offsite consequence risk from beyond design basis event severe accidents. This report focuses on the accident progression and source term insights developed from the MELCOR analyses. MELCOR is the NRC's best-estimate, severe accident computer code used in the SOARCA UAs. In anticipation of the SOARCA UA insights work, NRC and Sandia benchmarked the response of the Peach Bottom model to selected reference calculations from the Peach Bottom SOARCA UA. Peach Bottom was the first SOARCA UA performed and was completed in 2015 using the MELCOR 1.8.6 code. The PWR SOARCA UAs evolved the original methodology and utilized the updated MELCOR 2.2 computer code. The Peach Bottom model has been systematically updated for other NRC research efforts and has been updated to MELCOR 2.2. computer code. The findings from the new reference calculations using the updated model with the MELCOR 2.2 code are also integrated into the report. A second objective is an assessment of the applicability of the results to the other nuclear reactors in the U.S. As the key findings are reviewed, judgments are presented on the applicability of the results to other U.S. nuclear power plants. An important objective of the SOARCA program relied on high- fidelity plant-specific modeling. However, the nature of the insights and conclusions allowed judgements to be made on the applicability of the various insights to the same general classification of plant (i.e., BWR or PWR) or the entire fleet of plants. Finally, the results from the SOARCA UA accident progression calculations contain a wealth of information not previously documented in the NUREG/CRs. This report includes new but related information that can be used to benchmark past or support future regulatory decisions related to severe accidents. The new work includes a benchmark of the NUREG-1465 licensing source term definitions, the variability of key accident progression events and timing to radionuclide release, and an improved understanding of the timing and source terms from consequential steam generator tube ruptures. iii ACKNOWLEDGEMENTS The Sandia authors gratefully acknowledge the significant technical and programmatic contributions from the NRC SOARCA team which are reflected throughout the report. Dr. Tina Ghosh has been involved throughout the SOARCA UAs, providing the primary managerial and technical oversight. The long lists of NRC and Sandia contributors from the SOARCA UAs are cited in the three NUREG/CRs and are also gratefully acknowledged by the small team of authors compiling the results of their efforts. Significant technical contributions, advice, and reviews were provided by Dr. Hossein Esmaili, Dr. Alfred Hathaway, and Dr. Edward Fuller (retired) of the NRC. Dr. Randal Gauntt (retired), Mr. Patrick Mattie, Mr. Joseph Jones (retired), and Dr. Doug Osborn from Sandia are recognized as the SOARCA UA managers guiding the past efforts. There is a comparable list of project managers at the NRC including Ms. Patricia Santiago, Dr. Salman Haq, and Mr. Jon Barr. Sadly, we have lost Mr. Charlie Tinkler and Mr. Robert Prato, who were important contributors to the original SOARCA project. Finally, Mr. Kyle Ross and Mr. Mark Leonard have also retired but were significant technical contributors. Mr. Kyle Ross was the technical lead on all three SOARCA UAs and the original pressurized water reactor SOARCA study. Mr. Leonard was the technical lead on the original boiling water reactor SOARCA study and a key contributor to the first Peach Bottom SOARCA UA. iv

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CTF Validation and Verification (V.4.2)

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model-rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Year-2 of Water NSTF Matrix Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems of advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

Foam, due to the high gas generation rates of boiling and chemical reaction offgasing, requires control measures to prevent the foam from contaminating the condensate and to facilitate efficient plant operation. Antifoam was utilized to minimize foam production during chemical processing in the DWPF and during High-Level Waste (HLW) evaporation at SRS and Hanford. However, the current antifoam used in the SRS DWPF increases flammability risk during chemical processing (generates three flammable degradation products) and while feeding the melter (can decompose to CO/hydrogen). It is also the likely source of methyl functional groups for the organo-mercury present in the tank farm and excessive mercury in Saltstone. Additionally, the planned startup of Salt Waste Processing Facility (SWPF), with much higher throughput, will challenge DWPF to process at higher gas generation rates. DWPF employs Antifoam 747, a superspreader produced by Momentive Performance Materials, as an antifoaming agent during waste processing. During DWPF chemical processing, antifoam must be effective up to boiling (i.e., up to 103°C) and between a pH of 3-13. Antifoam 747 is most effective at a pH range of 6-8 and degrades as pH deviates. In addition, SRNL identified three flammable antifoam degradation products using mass spectrometer (MS) and fourier transform infrared (FTIR) offgas analyzers during simulations. A new antifoam or a new method to control foam is needed to minimize DWPF processing time and reduce the risk of contamination. In addition, testing should be completed to ensure that other antifoams used in HLW processing do not have similar flammability hazards or cause unintended impacts in downstream processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simple Heat Pipe Model

This is a simple model designed to run fast but still maintain the key physics and feedback mechanisms of a heat pipe. First, the capillary pressure is a function of the liquid working fluid volume fraction. Second, the boiling and condensation are based on the saturation temperature that is based on the heat pipe pressure. When the pressure goes up, the saturation temperature goes up and the vapor rains on the wick. When the pressure goes down, the saturation temperature goes down and the liquid in the entire wick boils. This is how the heat pipe adjusts to stay robust under different temperatures and heat fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The STAT7 Code for Statistical Propagation of Uncertainties In Steady-State Thermal Hydraulics Analysis of Plate-Fueled Reactors

STAT7 was written to automate many of the steady-state thermal hydraulic safety calculations for the MIT research reactor, both for conversion of the reactor from highly enriched uranium fuel to low-enriched uranium fuel and for future fuel re-loads after the conversion. A Monte-Carlo statistical propagation approach is used to treat uncertainties in important parameters in the analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux or departure from nucleate boiling or onset of flow instability; but additional margin is obtained by basing the limiting safety settings on avoiding onset of nucleate boiling. STAT7 can simultaneously analyze all of the axial nodes of all of the fuel plates and all of the coolant channels for one stripe of a fuel element. The stripes run the length of the fuel, from the bottom to the top. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. By running STAT7 multiple times, full core analysis can be performed by analyzing the margin to ONB for each axial node of each stripe of each plate of each element in the core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Approximations in Modeling of BWR Bundle Void Distributions

In boiling water reactors, complex heterogeneous bundle designs, control blades adjacent to the corner of bundles, and the presence of boiling can lead to complex internal void distributions. A few approximations exist to model these void distributions. They could be modeled using a 1D axial solver in which each axial node is assumed to be at an average void, or each pin cell could be modeled with its own void concentration. In the latter case, the void could be discretized in pin-centered or coolant-centered channels. The goal of this project was to quantify the effect of using the different approximations for modeling internal void distributions on neutronics calculations. Using 3D void distributions calculated with CTF, Monte Carlo Neutral Particle (MCNP) transport code models were created for GE-9 and GE-14 lattices. For each model, the internal void distribution from CTF at a given axial node was selected, and a lattice calculation was carried out with MCNP. Comparisons between models using a lattice-averaged void, or using a void distribution in coolant-centered channels, showed large differences in reactivity which in some cases were well above 1,000 pcm, and it also showed differences in normalized fission rates greater than 20%. It was also found that using a lattice average void can lead to a significant difference in the estimation of the worth of a control blade. The differences found when comparing results from models using pin-centered and coolant-centered channels were up to 200 pcm in reactivity and up to 1.4% in the normalized fission rates. In addition to these two sets of comparisons, MCNP models were set up so that each subchannel had a saturated liquid component around the fuel pins and a saturated vapor component in the center to approximate annular flow. In comparison to the models using coolant-centered subchannels, up to 1–3% differences in normalized fission rates could be found.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantifying Thermal Output of Energetic Materials (LDRD Final Report)

We present the results of an LDRD project, funded by the Nuclear Deterrence IA, to develop capabilities for quantitative assessment of pyrotechnic thermal output. The thermal battery igniter is used as an exemplar system. Experimental methodologies for thermal output evaluation are demonstrated here, which can help designers and engineers better specify pyrotechnic components , provide thermal output guidelines for new formulations, and generate new metrics for assessing component performance and margin given a known failure condition. A heat-transfer analysis confirms that the dominant mode of energy transfer from the pyrotechnic output plume to the heat pellet is conduction via deposition of hot titanium particles. A simple lumped-parameter model of titanium particle heat transfer and a detailed multi-phase model of deposition heat transfer are discussed. Pyrotechnic function, as defined by "go/no-go" standoff testing of a heat pellet, is correlated with experimentally measured igniter plume temperature, titanium metal particle temperature, and energy deposition. Three high-speed thermal diagnostics were developed for this task. A three-color imaging pyrometer, acquiring 100k images per second on three color channels, is deployed for measurement of titanium particle temperatures. Complimentary measurements of the overall igniter plume emission ("color") temperature were conducted using a transmission-grating spectrograph in line-imaging mode. Heat flux and energy deposition to a cold wall at the heat-pellet location were estimated using an eroding thermocouple probe, with a frequency response of ~5 kHz. Ultimate "go/no-go" function in the igniter/heat-pellet system was correlated with quantitative thermal metrics, in particular surface energy deposition and plume color temperature. Titanium metal-particle and plume color temperatures both experience an upper bound approximated by the 3245-K boiling point of TiO 2 . Average metal-particle temperatures remained nearly constant for all standoff distances at T = 2850 K, ± 300 K, while plume color temperature and heat flux decay with standoff—suggesting that heat-pellet failure results from a drop in metal-particle flux and not particle temperature. At 50% likelihood of heat-pellet failure, peak time-resolved plume color temperatures drop well below TiO 2 boiling to ~2000 - 2200 K, near the TiO 2 melting point. Estimates of peak heat flux decline from up to 1 GW/m 2 for near-field standoffs to below 320 MW/m 2 at 50% failure likelihood.

36 MATERIALS SCIENCE↗

Impacts of LEU+ and HBU Fuel on Decay Heat and Radiation Source Term

Using low-enriched uranium with 235 U enrichment slightly greater than 5.0 wt % (LEU+) fuel is desirable for light water reactors (LWR) because it can enable longer cycles and/or smaller fresh fuel batches. This report analyzes the impact of LEU+ on back-end considerations, such as its impact on the spent fuel pool, and on the thermal and shielding performance of dry storage systems. For both pressurized water reactor (PWR) and boiling water reactor LEU+ fuel, this report concludes that additional cooling time or regionalized loading plans are required to maintain the same level of thermal and shielding performance of dry storage systems loaded with LEU fuel. For PWR fuel, this report concludes that the impact of LEU+ fuel on the time-to-boil of a spent fuel pool (SFP) is minimal and does not require considerable changes in SFP management.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CTF Validation and Verification: Version 4.3

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for light water reactor (LWR) analysis. It uses a two-fluid, three-field (i.e., fluid film, fluid drops, and vapor) modeling approach. Both subchannel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the CTF. One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model—rod bundle geometries with operating conditions that are representative of prototypical pressurized water reactor (PWR)s and boiling water reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Droplet burning of n-butyl acetate/n-heptane mixtures in the standard atmosphere: experiments and numerical modeling

Blending petroleum fuels with oxygenates is a common approach to stem the depletion of crude oil while also mitigating the impact of their combustion on the environment. It has recently been considered that n-butyl acetate (BA, C6H12O2 , boiling point of 399K) could be a viable oxygenate additive to diesel fuel. In this application it is important to determine the influence of the fractional amount of BA on burning of the mixture. This presentation considers this problem from an experimental and computational approach using n-heptane (C7H14 , boiling point of 372K) as an essentially single component surrogate for diesel fuel. The burning configuration considered was ostensibly spherical symmetry as promoted by burning droplets under conditions where forced and natural convection effects were minimized. In this configuration the droplet and flame are concentric spheres and soot aggregates are trapped in a shell structure between the droplet and flame. Measurements were made of the droplet, flame and soot shell diameters through video imaging of the burning process. The experimental results were used to validate a detailed numerical model of the spherically symmetric droplet burning process that incorporated a consistent combustion kinetic mechanism for BA/heptane mixtures, comprised of 402 species and 16,872 reactions inclusive of soot chemistry. A model for soot formation was also included in the simulation to predict formation of the soot shell. The simulations agreed well with measured droplet and flame diameters. It was found both experimentally and computationally that adding BA to heptane had a minimal effect on the mixture burning rate, while the flame was positioned closer to the droplet surface and the simulated soot volume fraction decreased. The implications of these results are discussed for using BA as a potential additive to diesel fuel.

09 BIOMASS FUELS↗

FY23 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY23. As a continuation of the modeling effort from FY22, this year’s work focuses on improving the RELAP5-3D model developed previously for two-phase flow simulations. The RELAP5-3D model is updated to more accurately capture the heat loss experienced by the facility. The updated model is compared against experimental data for benchmarking purposes of the RELAP5-3D input model. By correctly accounting for heat loss, the updated RELAP5-3D model can now predict the two-phase baseline case more accurately. The onset and the duration of instability are captured well by the model. Furthermore, analyses are performed to better understand the instability mechanism experienced by the flow where the expansion of the boiling boundary in the chimney is studied in details and the fundamental frequencies of the oscillations are obtained. The updated RELAP5-3D model is further compared against four fault conditions, namely the reduction of riser header inlet flow area, depletion of system inventory, blocked riser channels, and static boiling scenario. For each fault condition, minor modifications and tuning are performed to improve the predictions of the model. The purpose of the analyses is to investigate the capability of RELAP5-3D in predicting complex two-phase flows in possible accident scenarios in actual Reactor Cavity Cooling System (RCCS). Overall, the model is able to capture the behaviors and trends of these fault conditions relatively well. Some discrepancies remain between the experimental data and the predictions, many of which are likely due to the differences in the predicted and experimental vapor generation rate. Future work will focus on the continued development of the current RELAP5-3D input model of the NSTF to both improve the accuracy of the model’s predictive capability and continue supporting the experimental program needs. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗