Search NASA⌕ Search

SEARCH · Search NASA

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An extended moments model of quantum efficiency for metals and semiconductors

The complexity of photocathode designs and detector materials, and the need to model their performance for short pulse durations, response to high frequency photons, presence of coatings and/or thinness of the absorptive layer, necessitates modifications to three-step and moments models of photoemission that are used in simulation codes. Here, methods to include input from computationally intensive approaches, such as density functional theory to model optical properties and transfer matrix approaches to treat emission from the surface or transport past coatings, by means of parametric models are demonstrated. First, a technique to accurately represent optical behavior so as to model reflectivity and penetration depth is given. Second, modifications to bulk models arising from the usage of thin film architectures, and a means to rapidly calculate them, is provided. Third, a parameterization to model the impact of wells associated with coatings and surface layers on the transmission probably is given. In all cases, the methods are computationally efficient and designed to allow for including input from numerically intensive approaches that would otherwise be unavailable for simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

Quantum state preparation with resolution refinement

We introduce a method called resolution refinement that allows one to bootstrap eigenstate preparation on a quantum computer. We first prepare an eigenstate of a low-resolution Hamiltonian using any method of choice. The eigenstate is then lifted to higher resolution and adiabatically evolved to produce the corresponding eigenstate of a higher-fidelity Hamiltonian. We give examples of resolution refinement applied to both single-particle basis states as well as a spatial lattice grid. For basis refinement, we compute few-body ground states of the Busch model for interacting particles in a harmonic trap in one dimension. For lattice refinement, we compute Hartree-Fock nuclear states for a central Woods-Saxon potential in three dimensions, and we compute bound states and continuum states in a multi-species Hubbard model of fermions in one dimension. In all cases, the method is efficient and requires an adiabatic evolution time that scales with the inverse of the energy gap times the square root of the system size. We show that this very favorable scaling arises from the fact that resolution refinement does not make large changes to the structure or energies of the low-energy eigenstates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust optimization of intensity modulated proton therapy

Purpose: Intensity modulated proton therapy (IMPT) is highly sensitive to range uncertainties and uncertainties caused by setup variation. The conventional inverse treatment planning of IMPT optimized based on the planning target volume (PTV) is not often sufficient to ensure robustness of treatment plans. In this paper, a method that takes the uncertainties into account during plan optimization is used to mitigate the influence of uncertainties in IMPT. Methods: The authors use the so-called ''worst-case robust optimization'' to render IMPT plans robust in the face of uncertainties. For each iteration, nine different dose distributions are computed--one each for {+-} setup uncertainties along anteroposterior (A-P), lateral (R-L) and superior-inferior (S-I) directions, for {+-} range uncertainty, and the nominal dose distribution. The worst-case dose distribution is obtained by assigning the lowest dose among the nine doses to each voxel in the clinical target volume (CTV) and the highest dose to each voxel outside the CTV. Conceptually, the use of worst-case dose distribution is similar to the dose distribution achieved based on the use of PTV in traditional planning. The objective function value for a given iteration is computed using this worst-case dose distribution. The objective function used has been extended to further constrain the target dose inhomogeneity. Results: The worst-case robust optimization method is applied to a lung case, a skull base case, and a prostate case. Compared with IMPT plans optimized using conventional methods based on the PTV, our method yields plans that are considerably less sensitive to range and setup uncertainties. An interesting finding of the work presented here is that, in addition to reducing sensitivity to uncertainties, robust optimization also leads to improved optimality of treatment plans compared to the PTV-based optimization. This is reflected in reduction in plan scores and in the lower normal tissue doses for the same coverage of the target volume when subjected to uncertainties. Conclusions: The authors find that the worst-case robust optimization provides robust target coverage without sacrificing, and possibly even improving, the sparing of normal tissues. Our results demonstrate the importance of robust optimization. The authors assert that all IMPT plans should be robustly optimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guidance of Nonlinear Nonminimum-Phase Dynamic Systems

The research work has advanced the inversion-based guidance theory for: systems with non-hyperbolic internal dynamics; systems with parameter jumps; and systems where a redesign of the output trajectory is desired. A technique to achieve output tracking for nonminimum phase linear systems with non-hyperbolic and near non-hyperbolic internal dynamics was developed. This approach integrated stable inversion techniques, that achieve exact-tracking, with approximation techniques, that modify the internal dynamics to achieve desirable performance. Such modification of the internal dynamics was used (a) to remove non-hyperbolicity which is an obstruction to applying stable inversion techniques and (b) to reduce large preactuation times needed to apply stable inversion for near non-hyperbolic cases. The method was applied to an example helicopter hover control problem with near non-hyperbolic internal dynamics for illustrating the trade-off between exact tracking and reduction of preactuation time. Future work will extend these results to guidance of nonlinear non-hyperbolic systems. The exact output tracking problem for systems with parameter jumps was considered. Necessary and sufficient conditions were derived for the elimination of switching-introduced output transient. While previous works had studied this problem by developing a regulator that maintains exact tracking through parameter jumps (switches), such techniques are, however, only applicable to minimum-phase systems. In contrast, our approach is also applicable to nonminimum-phase systems and leads to bounded but possibly non-causal solutions. In addition, for the case when the reference trajectories are generated by an exosystem, we developed an exact-tracking controller which could be written in a feedback form. As in standard regulator theory, we also obtained a linear map from the states of the exosystem to the desired system state, which was defined via a matrix differential equation.

Devasia, Santosh↗

Probability Distribution Estimated From the Minimum, Maximum, and Most Likely Values: Applied to Turbine Inlet Temperature Uncertainty

Modern engineering design practices are tending more toward the treatment of design parameters as random variables as opposed to fixed, or deterministic, values. The probabilistic design approach attempts to account for the uncertainty in design parameters by representing them as a distribution of values rather than as a single value. The motivations for this effort include preventing excessive overdesign as well as assessing and assuring reliability, both of which are important for aerospace applications. However, the determination of the probability distribution is a fundamental problem in reliability analysis. A random variable is often defined by the parameters of the theoretical distribution function that gives the best fit to experimental data. In many cases the distribution must be assumed from very limited information or data. Often the types of information that are available or reasonably estimated are the minimum, maximum, and most likely values of the design parameter. For these situations the beta distribution model is very convenient because the parameters that define the distribution can be easily determined from these three pieces of information. Widely used in the field of operations research, the beta model is very flexible and is also useful for estimating the mean and standard deviation of a random variable given only the aforementioned three values. However, an assumption is required to determine the four parameters of the beta distribution from only these three pieces of information (some of the more common distributions, like the normal, lognormal, gamma, and Weibull distributions, have two or three parameters). The conventional method assumes that the standard deviation is a certain fraction of the range. The beta parameters are then determined by solving a set of equations simultaneously. A new method developed in-house at the NASA Glenn Research Center assumes a value for one of the beta shape parameters based on an analogy with the normal distribution (ref.1). This new approach allows for a very simple and direct algebraic solution without restricting the standard deviation. The beta parameters obtained by the new method are comparable to the conventional method (and identical when the distribution is symmetrical). However, the proposed method generally produces a less peaked distribution with a slightly larger standard deviation (up to 7 percent) than the conventional method in cases where the distribution is asymmetric or skewed. The beta distribution model has now been implemented into the Fast Probability Integration (FPI) module used in the NESSUS computer code for probabilistic analyses of structures (ref. 2).

Holland, Frederic A., Jr.↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant: Preprint

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Review of probabilistic analysis of dynamic response of systems with random parameters

The various methods that have been studied in the past to allow probabilistic analysis of dynamic response for systems with random parameters are reviewed. Dynamic response may have been obtained deterministically if the variations about the nominal values were small; however, for space structures which require precise pointing, the variations about the nominal values of the structural details and of the environmental conditions are too large to be considered as negligible. These uncertainties are accounted for in terms of probability distributions about their nominal values. The quantities of concern for describing the response of the structure includes displacements, velocities, and the distributions of natural frequencies. The exact statistical characterization of the response would yield joint probability distributions for the response variables. Since the random quantities will appear as coefficients, determining the exact distributions will be difficult at best. Thus, certain approximations will have to be made. A number of techniques that are available are discussed, even in the nonlinear case. The methods that are described were: (1) Liouville's equation; (2) perturbation methods; (3) mean square approximate systems; and (4) nonlinear systems with approximation by linear systems.

Kozin, F.↗

WE-DE-207B-10: Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation

Purpose: Scatter contamination is detrimental to image quality in dedicated cone-beam breast CT (CBBCT), resulting in cupping artifacts and loss of contrast in reconstructed images. Such effects impede visualization of breast lesions and the quantitative accuracy. Previously, we proposed a library-based software approach to suppress scatter on CBBCT images. In this work, we quantify the efficacy and stability of this approach using datasets from 15 human subjects. Methods: A pre-computed scatter library is generated using Monte Carlo simulations for semi-ellipsoid breast models and homogeneous fibroglandular/adipose tissue mixture encompassing the range reported in literature. Projection datasets from 15 human subjects that cover 95 percentile of breast dimensions and fibroglandular volume fraction were included in the analysis. Our investigations indicate that it is sufficient to consider the breast dimensions alone and variation in fibroglandular fraction does not significantly affect the scatter-to-primary ratio. The breast diameter is measured from a first-pass reconstruction; the appropriate scatter distribution is selected from the library; and, deformed by considering the discrepancy in total projection intensity between the clinical dataset and the simulated semi-ellipsoidal breast. The deformed scatter-distribution is subtracted from the measured projections for scatter correction. Spatial non-uniformity (SNU) and contrast-to-noise ratio (CNR) were used as quantitative metrics to evaluate the results. Results: On the 15 patient cases, our method reduced the overall image spatial non-uniformity (SNU) from 7.14%±2.94% (mean ± standard deviation) to 2.47%±0.68% in coronal view and from 10.14%±4.1% to 3.02% ±1.26% in sagittal view. The average contrast to noise ratio (CNR) improved by a factor of 1.49±0.40 in coronal view and by 2.12±1.54 in sagittal view. Conclusion: We demonstrate the robustness and effectiveness of a library-based scatter correction method using patient datasets with large variability in breast dimensions and composition. The high computational efficiency and simplicity in implementation make this attractive for clinical implementation. Supported partly by NIH R21EB019597, R21CA134128 and R01CA195512.The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

SU-E-T-179: Exploring Appropriate Offset Values for Pencil Beam and Monte Carlo Dose Optimization in Lung Stereotactic Body Radiotherapy Encompassing the Effects of Respiration and Tumor Location

Purpose: Exploring appropriate offset values in dose optimization with pencil beam (PB) algorithm to minimize dosimetric differences with plans calculated with Monte Carlo (MC) for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). Methods: 20 cases of Non-Small Cell Lung Cancer, treated with gated full motion range SBRT were selected. According to the proximity of the Gross Tumor Volume (GTV) to the chest wall, two groups are defined: peripherally located when GTV merges with the chest wall for at least 50% of the lesion diameter, and centrally located when the GTV is surrounded by lung tissue. Treatment plans were created on 4D average intensity projection (AIP) CT set with Brainlab iPlanDose 4.1.2 planning system. The D97 of PTV was normalized to 50Gy using the fast PB and compared with MC. The optimized plan was then recomputed over each 4D respiratory phase, and compared with MC using the same plan MU's. Results: The mean difference in the PB and MC D97 of the ITV was 10.5% (±0.8%) of the prescription dose (50Gy). PB algorithm showed 2.3–2.4% less overestimation to the D97 of the ITV, when comparing to MC, in the maximum exhalation phase than in the maximal inhalation phase. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus for central lesions (12.7±0.8%) (p< 0.01). Conclusion: The dosimetric differences between PB and MC can be reasonably predicted depending on the location of lesion in the lung, and may be used as offset value in dose optimization with PB. Since the maximal exhalation phase demonstrates less dose discrepancy between the two algorithms than that in maximal inhalation phase, caution is suggested when the latter is included as a major phase portion in the respiration gated lung SBRT.

60 APPLIED LIFE SCIENCES↗

SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.200900420) and the Radiation Technology Research and Development program (Grant No.2013043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Perimatrix of middle ear cholesteatoma: A granulation tissue with a specific transcriptomic signature

Objectives/Hypothesis: To establish comprehensive transcriptomic profiles of cholesteatoma perimatrix tissue and granulation tissue from chronic otitis media (COM) that did not develop cholesteatoma, which can indicate molecular pathways involved in the cholesteatoma perimatrix pathology and invasiveness. Study Design: Retrospective Case Series. Methods: Transcriptome data were obtained from cholesteatoma perimatrix tissue and COM granulation tissue by an Illumina iScan microarray. Differentially expressed genes (DEGs) were subsequently analyzed using both bioinformatical functional annotation and network analysis. Expression of candidate genes (MMP9 and LCN2) was validated by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) on a larger group of samples. Results: Analysis of the transcriptome led to the identification of 169 differentially expressed genes between investigated tissues. Bioinformatic analysis suggested that most significant biological processes involving DEGs were previously described in cholesteatoma pathology. Network analysis identified ERBB2, TFAP2A, and TP63 as major hubs of the DEGs molecular network. Furthermore, it was observed that the cellular component most significantly enriched in DEGs was extracellular space containing 47 DEGs. Using qRT-PCR, it was confirmed that mRNA levels of the major extracellular hub (MMP9) are increased, whereas its interacting molecule (LCN2) mRNA levels were decreased in cholesteatoma perimatrix tissue compared to COM granulation tissue. Conclusions: The current study approach offers an overall look at molecular mechanisms that describe the cholesteatoma entity by focusing exclusively on the perimatrix processes in comparison to COM granulation tissue. The observed differences in gene expression between cholesteatoma perimatrix and COM granulation tissue could suggest novel markers potentially influenced by the perimatrix–matrix molecular interplay, which is not present in COM without cholesteatoma. Level of Evidence: NA. Laryngoscope, 130:E220–E227, 2020. © 2019 The American Laryngological, Rhinological and Otological Society, Inc.

60 APPLIED LIFE SCIENCES↗

Machine learning-driven descriptions of protein dynamics at solid-liquid interfaces

This chapter has described how ML has enabled quantitative analysis of HS-AFM data to discover the physical phenomena governing protein dynamics and ordering at solid-liquid interfaces. The research detailed in this chapter modeled the rotation models of protein nanorods, the discovery of which would otherwise not be possible. By tracking the trajectories of individual protein rods from frame to frame, it was possible to model Brownian type motion and behaviors and Levy-flight dynamics that had not previously been shown. We also described the application of the Python package AtomAI, which has been developed specifically to analyze and extract physical phenomena, providing exemplar code for training an ensemble of deep neural networks to produce the semantic segmentation of AFM data and functions for encoding and decoding local environments. We last described a combinatorial approach to analyze very noisy data with a densely covered substrate where the emergence of order for the protein liquid crystals could be elucidated. By combining the methods from Case 1 and 2, it was possible to obtain the center of mass and angle for each rod in the images and track the assembly of the rods over time into a 2D liquid crystal array on the surface of mica.

protein dynamics, solid-liquid interfaces, atomic ↗

DES science portal: Computing photometric redshifts

We present the Dark Energy Survey (DES) Science Portal, an integratedweb-based data interface designed to facilitate scientific analysis. Wedemonstrate how the Portal can provide a reliable environment to accesscomplete data sets, provide validation algorithms and metrics in the case ofmultiple methods and training configurations, and maintain the provenancebetween the different steps of a complex calculation, while ensuringreproducibility of the results. We use the estimation of DES photometricredshifts (photo-$z$s) as an example. A significant challenge facingphotometric surveys for cosmological purposes, such as DES, is the need toproduce reliable redshift estimates. The choice between competing algorithmsand configurations and the maintenance of an up-to-date spectroscopic databaseto build training sets, for example, are complex tasks when dealing with largeamounts of data that are regularly updated and constantly growing. We show howthe DES Science Portal can be used to train and validate several photo-$z$algorithms using the DES first year (Y1A1) data. The photo-$z$s estimated inthe Portal are used to feed the creation of catalogs for scientific workflows.While the DES collaboration is still developing techniques to obtain precisephoto-$z$s, having a structured framework like the one presented here iscritical for the systematic vetting of DES algorithmic improvements and theconsistent production of photo-$z$s in future DES releases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prognostic model and failure mechanisms of steam generators in Sodium-Cooled fast reactors

This paper presents a prognostic model for sodium-cooled fast reactor (SFR) steam generators (SGs). Here, the purpose of the model is to estimate the remaining useful life of SFR SGs and thus to support the decision-making of autonomous control. SFR SGs are of great interest for plant integrity due to their harsh operation environment. They operate at higher temperatures and higher coolant-to-steam pressure differences than those of current light water reactors (LWR). The severity of the SFR SG failure consequences, which include water-sodium contact, is another reason. Understanding its failure mechanisms is important for the development of its prognostic model. Based on our literature review and physics-based analysis, we concluded that creep would be a dominant degradation mode of SFR SGs due to SFR’s high-temperature and high-pressure environment. Thus, creep is the focus of the prognostic model. Various other failure modes were also investigated in this study. The mechanical fatigue due to flow-induced vibration is usually observed in early developmental phases and would not be an important issue during normal operation. The thermal fatigue due to thermal stripping is occasionally observed in other components in SFRs but does not affect SG integrity. Pure water stress corrosive crack, fretting, and so on are commonly observed in LWR SGs but are significantly less important in SFR SGs because of the high temperatures, high pressure differences, and chemical properties of liquid sodium. Based on these investigations, a prognostic model focusing on creep failures was developed. It estimates the failure probability profile by sampling the Larson-Miller parameter (LMP) and temperature and associated uncertainties through Monte Carlo methods. Two case studies were presented. The first one demonstrated the model’s capability to calculate the failure probability for a new specimen within a given time. If the tube is working under temperatures of 500C ± 3 and pressures of 15.2 MPa, which leads to LMP of 20,100 ± 50, the failure probabilities within 50, 70, and 90 years are approximately 0.1 %, 3.2 %, and 17.5 %. The second demonstrated how adjusting the workload can help to protect the integrity of the component. For an old tube reaching 99 % of its lifespan, continuing to run at temperatures of 500C ± 3 and LMP of 20,100 ± 50 leads to a failure probability of about 29.0 % within a year. If the temperature is reduced by 5C, the failure probability can be reduced to 2.5 %, and, if the pressure is also reduced such that the LMP is increased by 100, the failure probability can further be reduced to 0.12 %.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗