Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Battery Cell Thermal Runaway Calorimeter

We currently have several methods for determining total energy output of an 18650 lithium ion cell. We do not, however, have a good method for determining the fraction of energy that dissipates via conduction through the cell can vs. the energy that is released in the form of ejecta. Knowledge of this fraction informs the design of our models, battery packs, and storage devices; (a) No longer need to assume cell stays together in modeling (b) Increase efficiency of TR mitigation (c) Shave off excess protection.

Darcy, Eric↗

Guarded Flat Plate Cryogenic Test Apparatus and Calorimeter

A test apparatus for thermal energy measurement of disk-shaped test specimens has a cold mass assembly locatable within a sealable chamber with a guard vessel having a guard chamber to receive a liquid fluid and a bottom surface to contact a cold side of a test specimen, and a test vessel having a test chamber to receive a liquid fluid and encompassed on one side by a center portion of the bottom surface shared with the guard vessel. A lateral wall assembly of the test vessel is closed by a vessel top, the lateral wall assembly comprising an outer wall and an inner wall having opposing surfaces that define a thermal break including a condensable vapor pocket to inhibit heat transfer through the lateral wall from the guard vessel to the test vessel. A warm boundary temperature surface is in thermal communication with a lower surface of the test specimen.

Fesmire, James E.↗

Guarded Flat Plate Cryogenic Test Apparatus and Calorimeter (C-600)

A test apparatus for thermal energy measurement of disk-shaped test specimens has a cold mass assembly locatable within a sealable chamber with a guard vessel having a guard chamber to receive a liquid fluid and a bottom surface to contact a cold side of a test specimen, and a test vessel having a test chamber to receive a liquid fluid and encompassed on one side by a center portion of the bottom surface shared with the guard vessel. A lateral wall assembly of the test vessel is closed by a vessel top, the lateral wall assembly comprising an outer wall and an inner wall having opposing surfaces that define a thermal break including a condensable vapor pocket to inhibit heat transfer through the lateral wall from the guard vessel to the test vessel. A warm boundary temperature surface is in thermal communication with a lower surface of the test specimen.

Fesmire, James E.↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of High-Granularity Dual-Readout Calorimetry with psec Timing

Dual-readout and particle flow algorithm (PFA) are technologies proposed for precise jet energy measurement in future colliders. While PFA requires highly granular calorimeters, dual-readout has mainly been used with fiber-based calorimeters that do not have highly segmented capabilities. It is still non-trivial to combine these two technologies in one calorimeter system because of the use of fibers in most of the dualreadout calorimeters, which is not compatible with the high granularity requirement of PFA technologies. The aim of this study is to develop a novel calorimetry that combines dual-readout and PFA by adopting a highly segmented tile-based configuration. This paper compares the improvement of energy resolution using dual-readout approach across several configurations of highly granular hadron calorimeters through simulation. Results indicate that setups with fine sampling and close placement of scintillators and Cherenkov detectors improve dual-readout performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of muons near shower cores at sea level using the E594 neutrino detector

The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter.

Goodman, J. A.↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

The Mu2e Digitizer ReAdout Controller (DiRAC): characterization and radiation hardness

The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.

43 PARTICLE ACCELERATORS↗

Characterization of nuclear breakup as a function of hard-scattering kinematics using dijets measured by ATLAS in p+Pb collisions

This Letter analyzes the sensitivity of event geometry estimators to the initial-state kinematics of hard scattering in proton–lead collisions. This analysis uses dijets as a proxy for the parton–parton scattering configuration, correlating it with event geometry estimators, namely the energy deposited in the Zero-Degree Calorimeter and the transverse energy recorded in the Forward Calorimeter in the Pb-going direction. The analysis uses data recorded by the ATLAS detector at the Large Hadron Collider with a nucleon–nucleon center-of-mass energy of 8.16 TeV, corresponding to an integrated luminosity of 56 nb − 1 . The jets are measured within the pseudorapidity interval −2.8 < η < 4.5, where positive η values correspond to the direction of the proton beam. Results are presented as a function of the Bjorken-x of the parton originating from the proton, xp . Both event geometry estimators are found to be dependent on xp , with the energy deposited in the Zero-Degree Calorimeter about six times less sensitive to xp compared with the transverse energy deposited in the Forward Calorimeter.

Aad, G↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗