Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Yahoo! Compute Coop (YCC). A Next-Generation Passive Cooling Design for Data Centers

The purpose of the Yahoo! Compute Coop (YCC) project is to research, design, build and implement a greenfield "efficient data factory" and to specifically demonstrate that the YCC concept is feasible for large facilities housing tens of thousands of heat-producing computing servers. The project scope for the Yahoo! Compute Coop technology includes: - Analyzing and implementing ways in which to drastically decrease energy consumption and waste output. - Analyzing the laws of thermodynamics and implementing naturally occurring environmental effects in order to maximize the "free-cooling" for large data center facilities. "Free cooling" is the direct usage of outside air to cool the servers vs. traditional "mechanical cooling" which is supplied by chillers or other Dx units. - Redesigning and simplifying building materials and methods. - Shortening and simplifying build-to-operate schedules while at the same time reducing initial build and operating costs. Selected for its favorable climate, the greenfield project site is located in Lockport, NY. Construction on the 9.0 MW critical load data center facility began in May 2009, with the fully operational facility deployed in September 2010. The relatively low initial build cost, compatibility with current server and network models, and the efficient use of power and water are all key features that make it a highly compatible and globally implementable design innovation for the data center industry. Yahoo! Compute Coop technology is designed to achieve 99.98% uptime availability. This integrated building design allows for free cooling 99% of the year via the building's unique shape and orientation, as well as server physical configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

United States Data Center Energy Usage Report: 2025 Update

This report updates the 2024 Data Center Energy Usage Report (2024 Report) and estimates that data centers could account for 11.8% of total U.S. electricity by 2030. The estimate also includes a range of scenarios that indicate the energy use could be between 9.5 and 15.3% of total U.S. electricity use by 2030. In comparison, the 2024 Report estimate range was 6.7% to 12.0% of total U.S. electricity by 2028.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of Information Technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, on-site generation, and heat recovery.

Best Practices↗

Data Centers in the Industrial Sector

This fact sheet summarizes some of the key needs, barriers, and opportunities related to data center management and operations in the Industrial Sector.

data center, data center management, industrial se↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

RED-BL: Evaluating dynamic workload relocation for data center networks

In this study, we present RED-BL (Relocate Energy Demand to Better Locations), a framework to minimize the electricity cost for operating data center networks over consecutive intervals of fixed duration. Within each interval, RED-BL provides a mapping of workload to a set of geographically distributed data centers. To this end, RED-BL uses the geographical and temporal variations in electricity prices as exhibited by electrical energy markets. In addition, we incorporate the transition costs associated with a change in workload mapping from one interval to the next, over a planning window comprising multiple such intervals. This results in a sequence of workload mappings that is optimal over the entire planning window, even though the workload mapping in a given interval may not be locally optimal. Our evaluation of RED-BL uses electricity prices from the US markets and workload traces from live Internet applications with millions of users. We find that RED-BL can reduce the electric bill by as much as 45% compared to the case when the workload is uniformly distributed. When compared to existing workload relocation solutions, for a wide range of data center deployment sizes, RED-BL achieves electricity cost savings that are 8.28% higher, on average. This seemingly modest reduction can save millions of dollars for the operators. The cost of this saving is an inexpensive computation at the start of each planning window.

97 MATHEMATICS AND COMPUTING↗

Power-Aware Data Center Project: Final Report

Due to cost and space concerns, data centers are becoming increasingly limited in their ability to enhance their power infrastructure to support increased compute power on the machine-room floor. The key hypothesis underlying this work is that there is a substantial amount of “trapped capacity” in existing supercomputing data centers. That is, more power infrastructure may be allocated to existing supercom puters than these supercomputers (a) can possibly or (b) typically draw. Consequently, it may be possible to increase the amount of computational throughput delivered using an existing power infrastructure as long as power can be capped at a lower-than-peak level.

97 MATHEMATICS AND COMPUTING↗

Integration of Solid Oxide Fuel Cell Systems Into Artificial Intelligence Data Centers

This report presents the results of a techno-economic analysis (TEA) that evaluates the economic benefits of integrating solid oxide fuel cell (SOFC) systems with artificial intelligence (AI) data centers. The analysis was completed in two phases: a scoping-level analysis was performed to identify impactful integration opportunities, followed by a more detailed TEA. Results show that, due to their modularity, SOFC can meet the 99.999% availability requirement of data centers with minimal additional costs. Heat integration via absorption chillers decreases data center electricity consumption at the tradeoff of increased water consumption. Higher SOFC exhaust temperatures are important for achieving larger electricity savings. Finally, power electronics integration with SOFC direct current electricity can reduce electricity consumption by 9 percent and reduce water consumption by 6.4 percent.

20 FOSSIL-FUELED POWER PLANTS↗

Understanding data motion in the modern HPC data center

The utilization and performance of storage, compute, and network resources within HPC data centers have been studied extensively, but much less work has gone toward characterizing how these resources are used in conjunction to solve larger scientific challenges. To address this gap, we present our work in characterizing workloads and workflows at a data-center-wide level by examining all data transfers that occurred between storage, compute, and the external network at the National Energy Research Scientific Computing Center over a three-month period in 2019. Using a simple abstract representation of data transfers, we analyze over 100 million transfer logs from Darshan, HPSS user interfaces, and Globus to quantify the load on data paths between compute, storage, and the wide-area network based on transfer direction, user, transfer tool, source, destination, and time. We show that parallel I/O from user jobs, while undeniably important, is only one of several major I/O workloads that occurs throughout the execution of scientific workflows. We also show that this approach can be used to connect anomalous data traffic to specific users and file access patterns, and we construct time-resolved user transfer traces to demonstrate that one can systematically identify coupled data motion for individual workflows.

Lockwood, GK↗

State & Local Government Data Centers

This fact sheet summarizes some of the key needs, barriers, and opportunities related to data center management and operations in the state and local government sector.

data center, data center management, local governm↗

Data availability and the role of the earth resources observation systems data center

With the launch of LANDSAT-1 in July 1972, and the follow-on launch of LANDSAT-2 in January of this year, routine availability of satellite imagery and electronic data of the earth's resources has become a reality. Federal data centers provide LANDSAT data to resource managers and the general public. These data centers have to date provided almost 500,000 frames of LANDSAT data at a cost of more than $2,000,000. Data from the LANDSAT satellite program, along with data and information from the Skylab manned program, are available over any location to anyone for the cost of reproduction.

Watkins, A. H.↗

Data Center Energy Practitioner (DCEP) Program

The main objective for the DCEP program is to raise the standards of those involved in energy assessments of data centers to accelerate energy savings. The program is driven by the fact that significant knowledge, training, and skills are required to perform accurate energy assessments. The program will raise the confidence level in energy assessments in data centers. For those who pass the exam, the program will recognize them as Data Center Energy Practitioners (DCEPs) by issuing a certificate. Hardware req.: PC, MAC; Software Req.: Windows; Related/Auxiliary software--MS Office; Type of files: executable modules, user guide; Documentation: e-user manual; Documentation: http://www.1.eere.energy.gov/industry/datacenters/ 12/10/15-New Documentation URL: https://datacenters.lbl.gov/dcep

Traber, Kim↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Astronomical Data Center Bulletin, volume 1, number 2

Work in progress on astronomical catalogs is presented in 16 papers. Topics cover astronomical data center operations; automatic astronomical data retrieval at GSFC; interactive computer reference search of astronomical literature 1950-1976; formatting, checking, and documenting machine-readable catalogs; interactive catalog of UV, optical, and HI data for 201 Virgo cluster galaxies; machine-readable version of the general catalog of variable stars, third edition; galactic latitude and magnitude distribution of two astronomical catalogs; the catalog of open star clusters; infrared astronomical data base and catalog of infrared observations; the Air Force geophysics laboratory; revised magnetic tape of the N30 catalog of 5,268 standard stars; positional correlation of the two-micron sky survey and Smithsonian Astrophysical Observatory catalog sources; search capabilities for the catalog of stellar identifications (CSI) 1979 version; CSI statistics: blue magnitude versus spectral type; catalogs available from the Astronomical Data Center; and status report on machine-readable astronomical catalogs.

Nagy, T. A.↗

IGS Data Center Working Group Report

At its 18th meeting held December 09, 2001 in San Francisco, the IGS Governing Board recommended the formation of a working group to focus on data center issues. This working group will tackle many of the problems facing the IGS data centers as well as develop new ideas to aid users both internal and external to the IGS. The direction of the IGS has changed since its start in 1992 and many new working groups, projects, data sets, and products have been created and incorporated into the service since that time. Therefore, this may be an appropriate time to revisit the requirements of data centers within the IGS.

Noll, Carey E.↗

BKG Data Center

This report summarizes the activities and background information of the IVS Data Center for the year 2012. Included is information about functions, structure, technical equipment, and staff members of the BKG Data Center.

Thorandt, Volkmar↗