Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Superconducting Levitated Detector of Gravitational Waves

A magnetically levitated mass couples to gravity and can act as an effective gravitational wave detector. We show that a superconducting sphere levitated in a quadrupolar magnetic field, when excited by a gravitational wave, will produce magnetic field fluctuations that can be read out using a flux tunable microwave resonator. With a readout operating at the standard quantum limit, such a system could achieve broadband strain noise sensitivity of h ≲ 10 − 20 / Hz for frequencies of 1 kHz–1 MHz, opening new corridors for astrophysical probes of new physics. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MaPSA Quality Control and AI-Enhanced Grading For the CMS Phase-II Tracker Upgrade

The Compact Muon Solenoid (CMS) experiment will undergo changes as part of the Large Hadron Collider upgrade. The CMS tracker will be upgraded to cope with the new radiation environment and to provide tracking at the first level trigger. This upgrade features a new type of silicon module called PS Module, which combines a Pixel sensor and a Strip sensor in the same module. The pixel portion of the PS module has a sensor bump bonded to 16 Macro Pixel ASICs (MPA) to form a Macro Pixel Sub Assembly (MaPSA). At Fermilab, MaPSAs are tested for quality control before being assembled with the strip sensors, readout and service electronics to form a PS Module. All of this test data is stored in a centralized database, and is used to grade the final module to determine if it will be installed in the detector. The Phase II Outer Tracker Analyzer of Test Outputs (POTATO) is the software that processes this data and determines the module grades. Using recent technologies, an AI agent is being im plemented into POTATO in order to allow users to more efficiently sort through the large amounts of analysis data and ensure that only the user specified data is being considered. This poster will display the process of testing a MaPSA, how that test data is relevant to module assembly and grading, and how the POTATO grading tool is being improved with the use of an embedded AI agent.

Gzamouranis, Olivia [Purdue U.]↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Magnets are Weber Bar Gravitational Wave Detectors

When a gravitational wave (GW) passes through a dc magnetic field, it couples to the conducting wires carrying the currents which generate the magnetic field, causing them to oscillate at the GW frequency. The oscillating currents then generate an ac component through which the GW can be detected-thus forming a resonant mass detector or a nagnetic Weber bar. We quantify this claim and demonstrate that magnets can have exceptional sensitivity to GWs over a frequency range demarcated by the mechanical and electromagnetic resonant frequencies of the system; indeed, we outline why a magnetic readout strategy can be considered an optimal Weber bar design. The concept is applicable to a broad class of magnets, but can be particularly well exploited by the powerful magnets being deployed in search of axion dark matter, for example, by DMRadio and ADMX-EFR. Explicitly, we demonstrate that the MRI magnet that is being deployed for ADMX-EFR can achieve a broadband GW strain sensitivity of ∼10^{-20}/sqrt[Hz] from a few kHz to about 10 MHz, with a peak sensitivity down to ∼10^{-22}/sqrt[Hz] at a kHz exploiting a mechanical resonance.

Domcke, Valerie↗

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]↗

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction framework advancements to support streaming for the ePIC detector at the EIC

The ePIC collaboration adopted the JANA2 framework to manage its reconstruction algorithms. This framework has since evolved substantially in response to ePIC’s needs. There have been three main design drivers: integrating cleanly with the Podio-based data models and other layers of the key4hep stack, enabling external configuration of existing components, and supporting timeframe splitting for streaming readout. The result is a unified component model featuring a new declarative interface for specifying inputs, outputs, parameters, services, and resources. This interface enables the user to instantiate, configure, and wire components via an external file. One critical new addition to the component model is a hierarchical decomposition of data boundaries into levels such as Run, Timeframe, PhysicsEvent, and Subevent. Two new component abstractions, Folder and Unfolder, are introduced in order to traverse this hierarchy, e.g. by splitting or merging. The pre-existing components can now operate at different event levels, and JANA2 will automatically construct the corresponding parallel processing topology. This means that a user may write an algorithm once, and configure it at runtime to operate on timeframes or on physics events. Overall, these changes mean that the user requires less knowledge about the framework internals, obtains greater flexibility with configuration, and gains the ability to reuse the existing abstractions in new streaming contexts.

Brei, Nathan [Thomas Jefferson National Accelerato↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Towards combination of charge and light readout at O(10) MeV energies in DUNE

The Deep Underground Neutrino Experiment (DUNE) is an experiment under construction that will employ 10-kt scale liquid-argon-TPC technology to do precision measurements of neutrino oscillations. Apart from the determination of CP violation in neutrino interactions, one of the main scientific goals of DUNE is the detection of neutrinos from a supernova burst. It is imperative to maximise the potential of the detector for extracting information for these rare events. The use of light signals to aid the calorimetry of neutrino interactions provides such potential. We will present current efforts to demonstrate the application of combined calorimetry in one of the DUNE prototype detectors at CERN. The ground-level placement of the detector allows collection of large samples of cosmic-ray muons stopping within its volume. Michel electrons from muon decay can be identified in both the ionization charge and scintillation light, serving as a proxy for supernova neutrino interactions at O(10) MeV energies. The method for demonstrating combined calorimetry and its associated challenges will be introduced. We will also summarise the current analysis status and future prospects.

Pěč, Viktor [Prague, Inst. Phys.] (ORCID:000000034↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗