At least 235 records · Page 13

Anaerobic Dynamic Membrane Bioreactor Development to Facilitate Organic Waste Conversion to Medium-Chain Carboxylic Acids and Their Downstream Recovery

Platform chemicals such as medium-chain carboxylic acids (MCCAs) can be produced from organic waste streams via chain elongation in anaerobic mixed-culture bioreactors. A product recovery system is needed to collect MCCAs from the bioreactor effluent. Membrane-based liquid–liquid extraction, the most commonly used product recovery approach, requires suspended solids removal from the bioreactor effluent to avoid membrane fouling. An anaerobic dynamic membrane bioreactor (AnDMBR) was developed to evaluate MCCA production from brewery and prefermented food waste and to produce a permeate with low suspended solids to facilitate downstream product recovery. The AnDMBR employed an inexpensive stainless-steel mesh as the support material for the development of a biofilm or dynamic membrane, which was responsible for solids–liquid separation. The AnDMBR produced a permeate quality with an average total suspended solids (TSS) concentration of 0.12 g L –1 , while the average bioreactor TSS concentration was two orders of magnitude higher (21.6 g L –1 ). A maximum solids removal efficiency of ≥99% was achieved and good permeate quality was sustained for over 200 days without fouling control or cleaning the support material. In addition to solids–liquid separation, the dynamic membrane was responsible for a substantial fraction of the biological activity of the AnDMBR. The relative activity of Clostridiales, as determined by 16S rRNA sequencing, correlated with MCCA production and was higher in the dynamic membrane (20.0 ± 4.9%) than in the suspended biomass (5.2 ± 2.7%) in the bioreactor. This observation was consistent with MCCA production data as the permeate MCCA concentrations were significantly (p = 8.2 × 10 –5 ) higher than that in the bioreactor, suggesting that the dynamic membrane biofilm contributed to chain elongation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crude-Oil-Repellent Membranes by Atomic Layer Deposition: Oxide Interface Engineering

Crude oil fouling on membrane surfaces is a persistent, crippling challenge in oil spill remediation and oilfield wastewater treatment. In this research, we present how a nanosized oxide coating can profoundly affect the anti crude-oil property of membrane materials. Select oxide coatings with a thickness of similar to 10 nm are deposited conformally on common polymer membrane surfaces by atomic layer deposition to significantly mitigate fouling during filtration processes. TiO 2 - and SnO 2 -coated membranes exhibited far greater anti-crude-oil performance than ZnO- and Al 2 O 3 -coated ones. Tightly bound hydration layers play a crucial role in protecting the surface from crude oil adhesion, as revealed by molecular dynamics simulations. Furthermore, this work provides a facile strategy to fabricate crude oil-resistant membranes with negligible impact on membrane structure, and also demonstrates that, contrary to common belief, excellent crude oil resistance can be achieved easily without implementation of sophisticated, hierarchical structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the Kinetics of Deactivation of Catalysts during the Upgrading of Bio-Oil

The fouling of catalysts for the upgrading of bio-oils appears to be very different from the fouling of catalysts for the hydroprocessing of petroleum-derived streams. There are two reasons for the differences: a) bio-oil contains polarizable components and phases that can stabilize reaction intermediates exhibiting charge separation and b) bio-oil components contain functional groups that contain O, notably carbonyls (>C=O). Aldol condensation of carbonyls affords very different pathways for the production of oligomeric, refractory deposits than does dehydrogenation/polymerization of petroleum-derived hydrocarbons. Colloquially, we refer to the bio-oil derived deposits as “gunk” to discriminate them from coke, the carbonaceous deposits encountered in petroleum refining. Classical gelation, appears to be a suitable model for the “gunking” reaction. Our work has helped explain the temperature range at which bio-oil should be pre-processed (“stabilized”) to confer longer lifetimes on the catalysts used for more severe processing. Stochastic modeling (kinetic Monte Carlo simulations) appears suitable to capture the rates of oligomerization of bio-oil. This work was supported by the US Department of Energy, Office of Energy Efficiency and Renewable Energy, Bioenergy Technologies Office. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle.

bio-oil upgrading↗

Contactless steam generation and superheating under one sun illumination

Steam generation using solar energy provides the basis for many sustainable desalination, sanitization, and process heating technologies. Recently, interest has arisen for low-cost floating structures that absorb solar radiation and transfer energy to water via thermal conduction, driving evaporation. However, contact between water and the structure leads to fouling and pins the vapour temperature near the boiling point. Here we demonstrate solar-driven evaporation using a structure not in contact with water. The structure absorbs solar radiation and re-radiates infrared photons, which are directly absorbed by the water within a sub-100 μm penetration depth. Due to the physical separation from the water, fouling is entirely avoided. Due to the thermal separation, the structure is no longer pinned at the boiling point, and is used to superheat the generated steam. We generate steam with temperatures up to 133 °C, demonstrating superheated steam in a non-pressurized system under one sun illumination.

14 SOLAR ENERGY↗

Mesolytic cleavage of homobenzylic ethers for programmable end-of-life function in redoxmers

Irreparable chemical damage to redox-active monomers, oligomers, and polymers (i.e. redoxmers) limits the lifetime of energy storage devices (e.g. redox flow batteries) by causing electrode and membrane fouling, as well as irreversible capacity loss. To predictably restore device and materials performance, it is desirable to add programmed destruction capabilities into these damage-prone materials. Here, we report the use of triggerable retrograde reactions to achieve programmable end-of-life function in redoxmers. Retrograde reactions are intended to break up damaged redoxmer materials into more soluble small-molecule constituents to prevent irreparably fouling battery interfaces. We investigated the redox-triggered mesolytic cleavage of homobenzylic ethers (HBEs) for this purpose. Combining experimental methods with simulations, we probed the influence of ring substituents on the programmable bond-scission behavior of HBEs. Variation of para-substituents on the HBEs allowed us to modify the oxidation potential, degradation pathway, and electrochemical mechanisms of the generated products. Given its ideal oxidation potential, we selected the para-methoxy-based HBE as the cleavage scaffold and integrated it with dialkoxybenzene, TEMPO, viologen, and para-nitrobenzene redox centers for compatibility, bulk deconstruction, and electrode defouling tests. Upon applying a high oxidation potential, the redox-active pendant is cleaved from the backbone via HBE bonds; of the four redox centers tested, three of them remained fully redox active. Viologen-appended redox active polymers with HBE linkers were cleaved to fully separate the redox centers from the backbone. Polymer-filmed electrodes were partially restored following HBE oxidation defouling. Here these studies highlight the co-design of new materials functions for developing sustainable energy storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid–liquid separation of lignocellulosic sugars from biomass by rotating ceramic disc filtration

In many biomass conversion processes, the separation of cellulosic sugars from residual, lignin-rich solids is a critical step, and achieving high recovery yields of sugars by conventional tangential crossflow and vacuum filtration is challenged by the presence of biomass solids, which rapidly foul filters, resulting in decreased throughput. Considering the performance limitations of traditional filtration methods, dynamic filtration, which generates high shear at the membrane surface to decrease fouling, is emerging as a viable alternative for demanding solid–liquid separations. For high solids separations, there is little available information regarding the performance, limitations, and energy consumption of dynamic filtration. To that end, here we characterized the performance of a dynamic filtration module, specifically a rotating ceramic disc (RCD) filter, for the aseptic recovery of cellulosic sugars from biomass solids following pretreatment and enzymatic hydrolysis. We show how RCD rotational velocity and percent biomass solids impact the filter throughput. Additionally, we used computational fluid dynamics (CFD) simulations to estimate the shear rate at the membrane surface and to visualize hydrodynamic profiles within the module. With the combined CFD simulations and experimental results, we estimated the energy demand and operating expenses for a viable dynamic filtration system operating with a lignocellulosic feed slurry. Our results indicate that an RCD filter can achieve ≥95% recovery of sugars and produce a retentate slurry containing 12 wt% insoluble solids with low energy consumption (a 2.2-fold improvement over cross-flow filtration) and low operating costs ($\$$0.06 per kg sugars). These results show a viable path towards operationally reliable, energy efficient, and cost-effective separations of sterilized cellulosic sugars from biomass solids and highlight the potential of dynamic filtration systems for challenging solid–liquid separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Antifouling strategies for protecting bioelectronic devices

Bioelectronic devices are playing an increasingly important role in many areas of our lives. They power a significant portion of medical diagnostics and are becoming more and more important for delivery of therapeutics and monitoring of chronic symptoms. However, surface fouling phenomena, and especially biofouling in complex biological fluids, restricts the performance of these devices and severely reduces their useful lifespan. In this Research Update, we discuss the main principles and strategies that researchers use to prevent fouling and minimize or remove the foulants from bioelectronic device surfaces. We also survey a variety of antifouling approaches that can enhance device performance.

36 MATERIALS SCIENCE↗

A Practical Comparison of Data-Driven Prognostics Methods for Energy Systems

This study explores data-driven prognostics for nuclear power plant (NPP) condensers, focusing on tube fouling. We utilized the Asherah nuclear power plant simulator (ANS) to compare four methods: Random Forest (RF), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory Neural Network (LSTM). By simulating various fouling scenarios in the ANS, we generated data with different degradation rates under transient operations. The models were trained and tested on these data, with performance evaluated visually and numerically including uncertainty assessment. The LSTM model excelled, exhibiting minimal prediction noise and the most accurate remaining useful life estimates across all degradation levels. Its ability to capture long-term dependencies and produce cleaner outputs makes it a strong candidate, although accurate training data across the entire component lifespan are crucial. The RF model emerged as a robust alternative, providing reliable predictions with high confidence. The FCNN and SVR models, while less effective overall, showed potential under specific conditions. FCNN offers a less complex alternative to LSTM and might benefit from larger datasets. SVR excels in precision when the quality of the training data is high. Furthermore, this study highlights the operational benefits of advanced prognostics in the energy sector and emphasizes the need for further research in NPP condenser health management through real-life experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a medium-duty stoichiometric diesel micro-pilot natural gas engine

Fueling a compression-ignition engine with premixed natural gas offers the potential to combine a clean-burning, low-carbon fuel with a high compression ratio, high-efficiency engine. This work describes the development of a multi-cylinder 6.7 L diesel engine converted to run stoichiometric diesel micro-pilot/ natural gas premix combustion with a maximum diesel contribution target of 5% of the total fuel energy and a three-way catalyst aftertreatment system. Results are given by comparing the stoichiometric combustion to the diesel baseline operation, showing combustion characteristics differences, including the rapid two stage heat release. A high load output of 23 bar brake mean effective pressure was obtained with diesel-like brake thermal efficiency of 41%. This operating condition enabled a brake specific CO 2 emissions reduction of up to 25% when compared to diesel. It was observed that the low load output is limited by combustion stability when operated at stoichiometric condition. The three-way catalyst is observed to run at peak efficiency with an equivalence ratio of 1.01. Injector fouling was observed through the inspection of the nozzle and its internal parts, indicating carbon build-up similar to that seen in injector coking mechanisms. A comparison of the developed engine to other engine technologies is given, showing that the diesel micro-pilot natural gas engine performance is in good standing among other diesel and gas engines in the market.

Engineering↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Cross-Flow Filtration of Multiple Algal Strains and Mixed Populations Using Embedded Membranes

The objective of this research is to analytically assess cross-flow membrane filtration (CFF) technology as an algal harvesting approach that will debottleneck the water recovery/nutrient recovery/recycling processes. Specifically, the focus of this investigation will be INL-developed, ceramic-embedded, erosion-resistant membrane technology, comprising stainless steel micro- and ultra-filters with controlled pore sizes to reduce membrane fouling and enhance filtration permeation properties. Parameters such as shear/face velocity and transmembrane pressure will be varied to assess impact on filtration efficiency. Detrimental effects such as cell lysis must also be considered. The project is an opportunity to analytically investigate the level of shear (cross-flow face velocity level) needed to accomplish dewatering by filtration in an economic manner while gaining insight into membrane fouling mechanisms. Furthermore, testing of the membranes with different starting concentrations of algae, as well as with a variety of membranes and filtration conditions, will allow us to establish the boundary conditions where membrane technologies are appropriate for application in an overall algal harvesting strategy.

09 BIOMASS FUELS↗

Development of Fault Models for Hybrid Fault Detection and Diagnostics Algorithm: October 1, 2014 -- May 5, 2015

This report describes models of building faults created for OpenStudio to support the ongoing development of fault detection and diagnostic (FDD) algorithms at the National Renewable Energy Laboratory. Building faults are operating abnormalities that degrade building performance, such as using more energy than normal operation, failing to maintain building temperatures according to the thermostat set points, etc. Models of building faults in OpenStudio can be used to estimate fault impacts on building performance and to develop and evaluate FDD algorithms. The aim of the project is to develop fault models of typical heating, ventilating and air conditioning (HVAC) equipment in the United States, and the fault models in this report are grouped as control faults, sensor faults, packaged and split air conditioner faults, water-cooled chiller faults, and other uncategorized faults. The control fault models simulate impacts of inappropriate thermostat control schemes such as an incorrect thermostat set point in unoccupied hours and manual changes of thermostat set point due to extreme outside temperature. Sensor fault models focus on the modeling of sensor biases including economizer relative humidity sensor bias, supply air temperature sensor bias, and water circuit temperature sensor bias. Packaged and split air conditioner fault models simulate refrigerant undercharging, condenser fouling, condenser fan motor efficiency degradation, non-condensable entrainment in refrigerant, and liquid line restriction. Other fault models that are uncategorized include duct fouling, excessive infiltration into the building, and blower and pump motor degradation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sacrificial Protective Coating Materials that can be Regenerated In-Situ to Enable High Performance Membranes

In the pulp and paper industry, weak black liquor concentration is carried out using energy intensive evaporators. Briefly, after wood digestion, water is evaporated to concentrate weak black liquor to the point where the black liquor can be burned in a recovery boiler, which ultimately leads to the recovery of digestion chemicals. Because it is less energy intensive than heat-driven separation, pressure-driven separation of water from black liquor using membranes could reduce the energy usage by 55 trillion Btu yr -1 and carbon dioxide emissions by more than 11 million metric tons CO 2 per year if the first two evaporators are replaced. However, weak black liquor is a hot, corrosive, and highly fouling feed with organic molecules, colloids, and ions that clog membranes within hours of operation. We have shown that membrane-based concentration of weak black liquor is feasible, but only with our antifouling and anti-clogging technology that is based on a sacrificial Bio-inspired Living Skin concept. This concept is based on a conformal coating that is formed at the membrane surface and within the pores. Weak foulant adhesion dramatically decreases membrane fouling while the superhydrophilicity of the coating increases the water permeability. Moreover, the coating can be completely removed during backflushing, which removes foulants that may irreversibly adhere to the coating over long periods of time. The skin shedding completely regenerates the membrane surface and pores, restoring the original flux. This is followed by in-situ recoating, using the existing membrane plumbing and pumps, which essentially creates a brand new membrane surface.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquefaction of Forest Biomass to "Drop-in" Hydrocarbon Biofuels

The overall goal of the project was to demonstrate solvent liquefaction as a viable path to stable intermediates for subsequent upgrading to fuel blendstocks. Iowa State University (ISU) utilized technology developed by Chevron to produce “green crude” via continuous biomass liquefaction to bio-oil without catalyst or reducing gas, then upgraded the crude to drop-in hydrocarbon liquid transportation fuels. Original benchmarks for the project included conversion of biomass to bio-oil at a yield of 50% or more, produce bio-oil with oxygen content below 20 wt%, and recycle a portion of the bio-oil product for use as solvent, displacing initial hydrocarbon solvent. Initial testing and technology development was completed by Chevron using a custom Small Continuous Liquefaction Unit (SCLU) operated in “once-through” mode. In this system, liquid product and solid residual/char was collected together and required both off-line solids removal and product separation. This unit was disassembled and major components incorporated into a redesigned solvent liquefaction system at ISU capable of processing biomass at rates up to 1 kg/h. Online, continuous solids separation and bio-oil recovery/separation systems were successfully implemented. Online solids removal using an acetone injection to aid in separation achieved over 99% solids removal efficiency, and acetone recovery of greater than 97% was achieved. The gas stripping system developed for the separation of medium wood oil (MWO) for the recycle stream from the heavy wood oil (HWO) product stream was also successful in recovering approximately 93 wt% of the initial solvent from the biomass-derived products. Due to the generation of fine particulate and the high molecular weight of the HWO which both negatively affect the ability to separate the product oil, solvent recycle was not fully implemented in the system. The biomass used in this project is loblolly pine forest residue. The solvent was a blend of two hydrocarbon liquids. The majority of the solvent was comprised of commercially available naphthalene-depleted heavy aromatic solvent. The hydrogen donor solvent was a proprietary cut of light cycle oil (LCO) that was hydrotreated. As much as 25 wt% of the solvent mixture was comprised of the hydrotreated LCO. Higher blend ratios were limited by the economics of providing hydrogen to the process in this manner. Two cases were evaluated for technical feasibility on the SCLU. These are 1. Simulated phenolic solvent recycle and 2. Hydrocarbon-rich solvent processing. The simulated phenolic solvent recycle case was based on an idealistic solvent mixture where only 5% makeup or hydrogen donor solvent entered the system. The resulting solvent mixture at steady state was estimated to be 75 wt% depleted hydrogen donor, 20 wt% biomass derived phenolic monomers, and 5 wt% HLCO. This case resulted in the highest bio-oil organic yield observed in the project of 66.7 wt% on a solvent-less, dry biomass basis and relatively low oxygen content of 12%. Additionally, these conditions deconstructed the biomass so well, that extremely fine particulate was generated such that 5 micron barrier filters were unable to remove the material. Offline addition of acetone, centrifugation and acetone removal were required in order to remove the particulate prior to fractionation with the stripping column. The resulting HWO had a high molecular weight and was therefore very viscous in nature, remaining solid at room temperature. Additionally, the column was unable to sustainably strip enough MWO to close the recycle loop balance while maintaining flowability of product oil exiting the column. It was determined that additional HLCO would be required at the front of the process to decrease product viscosity both by dilution and additional hydrogen transfer into the HWO product oil. The hydrocarbon rich mixture was the preferred mixture for a majority of the project and featured a 25% donor or HLCO content and 75% depleted hydrogen donor mix. A series of three tests were conducted using this mixture and serve as the basis for a paper detailing the system. While the online acetone injection system for high pressure solids removal was demonstrated early on using this mixture, difficulty controlling process flows led to the use of an atmospheric stirred tank filtration system. At these high donor solvent levels, the product stream easily partitioned with sufficient MWO to close the recycle loop balance. Additionally, this mixture produced HWO product oil at just over 55% yield, <5% oxygen content, and a reasonable viscosity at room temperature. A 56 hour campaign was conducted with the ISU pilot to produce a large enough batch of HWO product oil to conduct upgrading experiments at Chevron’s Richmond, CA facility. Benchtop hydrotreating units were used to conduct long-duration hydrogenation/hydrogenolysis reactions in order to provide yield data and help validate assumptions made in the TEA model. Resulting products featured an oxygen content of <1%, near the detectability limit. Hydrocracking simulations were also performed, and a distribution of heavy wood oil to refinery products was determined. These distributions are based on a database of commercial and pilot plant operation used by Chevron to estimate product yield from novel inputs based on the input physical and chemical characteristics. While multi-week benchtop hydrotreating tests were successfully conducted without fouling, analysis and testing of the heavy wood oil suggest it may be better suited for hydrocracking. Metals content in the heavy wood oil would likely create catalyst fouling over time and reduce lifetime of hydrotreating catalysts. Yields and product partitioning were also more favorable from hydrocracking compared to those from hydrotreating.

09 BIOMASS FUELS↗

Fiscal Year 2020 Filtration of Hanford Tank Waste 241-AP-105

Bench-scale filtration testing of 15 liters of 241-AP-105 supernatant was conducted using a Mott inline filter Model 6610 (media grade 5) backpulsed dead-end filter (BDEF) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. The as-received samples were diluted with raw water from the Hanford Site to assess the propensity for solids to form upon dilution and to assess the impact those solids have on filtration performance. The feed was split into two batches. The first batch was settled and decanted as planned in Tank Side Cesium Removal operations. The BDEF was used to filter this AP-105 feed at a targeted flux of 0.065 gpm/ft 2 and exhibited no measurable pressure increase during filtration. The second batch was fed to the BDEF with solids resuspended. This was also operated at the targeted flux of 0.065 gpm/ft 2 . In this case, the target pressure differential of 2 psid (resistance of 6.24 × 10 10 m -1 ) was reached in slightly more than 12 h. A backpulse restored the filter flux; however, the time to the next backpulse was slightly shorter. These tests indicate that after the addition of raw water, settle and decant effectively removed solids from the feed. It is not possible to assess the time required for these solids to settle based on the result from these tests. However, if sufficient time is allowed for the solids to settle, no measurable filter fouling was observed in current testing. In contrast, if insufficient time is allowed for solids to settle, filter fouling will occur relatively quickly and will likely require backpulses more frequently than every 12 hours (1.91 m 3 /m 2 volume filtered). Solids concentrated from backpulse solutions displayed large variability in composition with Al-silicates and mixed chromium-aluminum oxide phases. Amounts of Mg, Fe, and Ca were also found in the presence of Na and O. These solids could be grouped in three categories: (1) soluble Na-salts that formed large block-like particles but were made up of fibrous materials, (2) amorphous Al-phases, and (3) colloidal iron oxides with an average particle diameter of 4.2 µm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Algae Technology for CO2 Utilization

The United States, the world’s largest energy user and second largest CO2 emitter, is heavily dependent on fossil energy. In 2014, U.S. coal burning utilities emitted ~1562 million (MM) tons/year (TPY) of CO2 into the atmosphere, accounting for 76% of the total US power sector emissions1. Hence, reducing the CO2 emission footprint from coal plants is widely viewed as a key element in mitigating global warming. Despite significant interest, implementation of CO2 capture technologies has been constrained by the high capture cost which significantly increases the total cost of electricity. Not only is capturing CO2 with traditional technologies expensive, but generally the CO2 has little value and additional expense must be incurred for sequestration. This project funded by a SBIR grant from the U.S. D.O.E. to Helios-NRG in collaboration with the State University of New York at Buffalo (UB) and Membrane Technology and Research Inc. (MTR) aimed to develop a novel, algae based technology to capture CO2 from the effluent of coal-based power plants and convert it to renewable bio-fuels and higher value co-products such as animal feed and nutraceuticals with the potential to enable a substantial reduction in the net cost of carbon capture. The Phase 2 project was aimed at further demonstrating the technical feasibility of the proposed multi-stage continuous (MSC) flow CO2 capture system and the generation of high-value co-products to offset the CO2 capture cost. The project was completed and the project objectives were met and exceeded. A first-of-a-kind integrated, laboratory scale MSC process unit was fabricated and tested in a greenhouse. The tests were conducted with the preferred algae species identified in Phase I and simulated flue gas containing contaminants at levels typically present in the post flue gas desulfurization (FGD) stream, including ~12% CO2, acid gas (SOX, NOX), and a large number of heavy metals. The tests were successful and demonstrated a 25g/m2/day seasonal average algae productivity and an 80% CO2 capture efficiency. Two new algae species were identified for high-value nutraceutical production. Studies to improve growth rate and nutraceutical content of these algae species were performed and a pathway for further improvements was identified. A new dewatering technology called DeAqua was further advanced. Significant improvement in the performance index was achieved. The anti-fouling membrane was developed and fabricated into a module. The fabricated membrane module was tested with algae slurry and demonstrated improved fouling resistant properties, that can potentially reduce the cost and energy of the critical dewatering step. Test data were used to simulate operation of the overall process. The preliminary economic analysis was updated and modelled based on a 5000-acre algae farm. To the extent possible, the financial and operating assumptions used were the same as those used in the DOE’s 2022 projections for algae technology for CO2 capture and utilization. The results showed the proposed technology’s potential to significantly reduce the cost of CO2 capture compared to current options and that the high value products generated from the CO2 captured can make a step change in the cost of carbon capture. Plans to advance the technology to Phase 2B were developed and potential end-user partners were identified.

Maloney, James↗

Novel Patterned Surfaces for Improved Condenser Performance in Power Plants

In this project, we seek to improve the thermoelectric power plant performance through engi-neered nonwetting condenser tube surface designs that can enhance heat transfer performance by: (1) promoting dropwise condensation of the steam on the shell side and eliminating flooding of the surface structure by maintaining low droplet adhesion, thus increasing condensation heat transfer coefficient; (2) deterring fouling and corrosion, thereby reducing fouling resistance and improving heat transfer; (3) possibly reducing drag and increasing convective heat transfer inside coolant tubes; and (4) reducing the number of tubes, coolant water usage, and levelized cost of condenser.

20 FOSSIL-FUELED POWER PLANTS↗

Enhancing Lifetime and Reducing Costs for Fish Diversion Netting Structures (Abstract)

This effort will focus on technology transfer and commercialization of antifouling coatings with an enthusiastic and engaged industrial team. Environmental requirements and operational demands call for a nontoxic coating/paint to prevent fouling on fish passage guidance netting at hydropower facilities. For example, one netting customer estimated the capital cost for compliance at $\$12$ million to $\$15$ million. This project will build partnerships between PNNL and private companies to optimize, demonstrate, mature, and commercialize a novel PNNL-developed technology that addresses this critical coating need of the hydropower industry. This effort will support modification of existing coatings for application to flexible netting structures. Industrial partners include commercial coating development specialist (Lorama), hydrophobic material manufacturer and paint developer (Dry Surface Technologies), aquatic applications specialists (Prometheus Innovations and River Connectivity Systems), and hydropower netting producer (Pacific Netting Products). Engagement with the U.S. Army Corps of Engineers (USACE) and Bureau of Reclamation (BOR), two hydropower operators, throughout the project will provide expertise and field test sites that will provide crucial proof of real-world performance data (additional details provided in Teaming section). Taylor Shellfish Farms will provide organisms and fouling expertise as well as a perspective of potential broader impacts for the blue economy. Sample netting will demonstrate performance in a range of environments for key hydropower applications. PNNL will work with industrial partners to overcome commercialization barriers as well as resolving any manufacturing or regulatory issues. This Phase 1 effort is focused on technology optimization for application to fish passage guidance netting and technology validation as verified by independent testing (through USACE, BOR, Taylor Shellfish and Prometheus Innovations). Through this effort, SLIC will be demonstrated for netting applications at technology readiness level (TRL) 5. The field test data will allow optimization of SLIC formulation and performance which is key to enabling technology transfer of a mature proven technology to industry and production of a viable commercial product specifically focused for hydropower needs.