Hubble Space Telescope observations of planetary nebulae in the magellanic clouds. 2: SMP 85, a young planetary

We have obtained Hubble Space Telescope Planetary Camera images in the (O III) lambda 5007 A emission line, and Faint Object Spectrograph (FOS) UV spectrophotometry of the low-excitation planetary nebula SMP 85 in the Large Magellanic Cloud. By combining these results with existing optical spectrophotometry, absolute flux measurements, and dynamical and density information, we have been able to construct a fully self-consistent nebular model. This proves that SMP 85 is a dense, young, carbon-rich object which started to be ionized about 500-1000 years ago, and which contains a substantial inner reservoir of atomic or molecular gas, probably in the form of many small cloudlets. These cloudlets have been ejected at a velocity not exceeding 6 km/s, a result which, together with the morphology is an important clue to mass loss during late asymptotic giant branch (AGB) evolution. We have directly detected the central star through its UV continuum emission, and from both Zanstra techniques and nebular modeling derive a stellar temperature of 46000 +/- 2000 K, a stellar luminosity of 7300 +/- 700 solar luminosity, and a core mass of 0.63-0.67 solar mass. The nebular analysis also demonstrates that there is severe depletion of the nebular gases onto dust grains, most likely of the calcium magnesium silicate variety; a surprising result in view of the carbon-rich nature of the ionized nebula.

Dopita, Michael A.↗

Study of air pollutant detectors

The application of field ionization mass spectrometry (FIMS) to the detection of air pollutants was investigated. Current methods are reviewed for measuring contaminants of fixed gases, sulfur compounds, nitrogen oxides, hydrocarbons, and particulates. Two enriching devices: the dimethyl silicone rubber membrane separator, and the selective adsorber of polyethylene foam were studied along with FIMS. It is concluded that the membrane enricher system is not a suitable method for removing air pollutants. However, the FIMS shows promise as a useable system for air pollution detection.

Gutshall, P. L.↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon gas, useful for medical purposes, safely fixed in quartz

Radon gas is enclosed in quartz or glass ampules by subjecting the gas sealed at a low pressure in the ampules to an ionization process. This process is useful for preparing fixed radon sources for radiological treatment of malignancies, without the danger of releasing radioactive gases.

Fields, P. R.↗

Photoionization Modeling and the K Lines of Iron

We calculate the efficiency of iron K line emission and iron K absorption in photoionized models using a new set of atomic data. These data are more comprehensive than those previously applied to the modeling of iron K lines from photoionized gases, and allow us to systematically examine the behavior of the properties of line emission and absorption as a function of the ionization parameter, density and column density of model constant density clouds. We show that, for example, the net fluorescence yield for the highly charged ions is sensitive to the level population distribution produced by photoionization, and these yields are generally smaller than those predicted assuming the population is according to statistical weight. We demonstrate that the effects of the many strongly damped resonances below the K ionization thresholds conspire to smear the edge, thereby potentially affecting the astrophysical interpretation of absorption features in the 7-9 keV energy band. We show that the centroid of the ensemble of K(alpha) lines, the K(beta) energy, and the ratio of the K(alpha(sub 1)) to K(alpha(sub 2)) components are all diagnostics of the ionization parameter of our model slabs.

Kallman, T. R.↗

Experimental Study of the Fundamental Properties of Warm Dense Mixtures

The aim of the proposed research was to provide a multi-scale study of the properties of warm dense hydrocarbons, by studying the thermodynamic properties through the equation of state and the microscopic properties by x-ray scattering. Understanding the fundamental properties of warm dense mixtures is an intellectual challenge due to the complexity of the system. Unlike liquids or gases, where constituent particle interactions occur through collisions or bonding between valence electrons, in these strongly coupled systems the atoms will be partially ionized and compressed so tightly together that interactions between the inner core electrons can play a role in the systems chemistry. Advances in computational capabilities and development of new theoretical models have been used to predict the properties of mixtures but there is currently no experimental data of the fundamental interaction between the particles in mixtures to test these predictions against. The proposed research was to experimentally investigate the interaction of the different species in hydrocarbons by measuring the compressibility of substances with different carbon and hydrogen ratios and the complexity of the microscopic interactions through elastic and inelastic x-ray scattering. To study the bulk properties of warm dense hydrocarbons we established the Warm Dense Matter Research Laboratory (WDMRL) in the Institute for Shock Physics at Washington State University. The goal was for experiments in the WDMRL to determine shock loading conditions of interest in the hydrocarbon mixtures. We planned on using Hugoniot EOS measurements and a range of carbon and hydrogen concentrations to determine conditions when the EOS of the mixture varied significantly from that of the classical mixing model. Even though shock transit measurements through aluminum foils suggested pressures upto 400GPa, the experiments in the WDMRL were unsuccessful in getting usable shockwave compression data above 100GPa in polystyrene which was below the pressure of interest for hydrocarbon mixtures (>200GPa). To complete the project, we tested a technique using x-ray phase contrast imaging to map the location of tracer layers in a test sample of polycarbonate to record the material motion in dynamically compressed samples. A technique that will be useful for future warm dense matter experiments. These experiments used <200nm gold layers in polycarbonate samples to measure the material velocity and shock speed using x-ray phase contrast imaging. These results were compared to continuum surface measurements performed at ISP and show that the tracer layer technique can measure hydrodynamic properties accurately in dynamically compressed materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quadrupole ion pump performance characteristics.

A new nonmagnetic ion pump is described that resembles a quadrupole ionization gauge. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Pumping speeds (4-100 liters per sec) for different gases at various peak voltages (1000-3000 V) at corresponding frequencies (57-100 MHz) and at different pressures (10 microtorr to 1 nanotorr) are reported.

Schwarz, H.↗

Ionized absorbers, ionized emitters, and the X-ray spectrum of active galactic nuclei

Broad absorption features are common in the X-ray spectrum of low-luminosity AGNs. The features have been modeled by leaky neutral absorbers or by highly ionized gas that completely occult the continuum source. Such models are incomplete since they do not take into account all the physical processes in the gas. In particular, no previous model included the X-ray emission by the ionized absorbing gas and the reflection of the continuum source radiation. The present work discusses the emission, absorption, and reflection properties of photoionized gases with emphasis on conditions thought to prevail in AGNs. It shows that such gas is likely to produce intense X-ray line and continuum radiation and to reflect a sizable fraction of the nonstellar continuum at all energies. If such gas is indeed responsible for the observed X-ray absorption, then absorption edges are much weaker than commonly assumed, and some residual X-ray continuum is likely to be observed even if the line of sight is completely blocked. Moreover, X-ray emission features may show up in sources not showing X-ray absorption. This has immense consequences for medium-resolution X-ray missions, such as BBXRT and Astro-D, and for the planned high-resolution experiments on board XMM and AXAF.

Netzer, Hagai↗

Ionization effects in single-shot carrier-envelope phase detection with gas-gap devices

The carrier-envelope phase (CEP) is a key parameter for attosecond waveform control of ultrashort laser pulses. For laser systems with high repetition rates, however, single-shot CEP detection is still challenging. Building on recent findings on phase detection with electric current generation in gases, we show that with an optimized detection method, a long-term stable single-shot phase detection is feasible. We investigate the achievable performance depending on various parameters such as pulse duration, gas pressure, or incident intensity. The latter exhibits a regime where the saturation of the ionization process boosts the phase sensitivity of the signal, which is elucidated by numerical calculations.

47 OTHER INSTRUMENTATION↗

Vacuum measurements on the lunar surface.

Results of measurements of neutral gas pressure on the lunar surface made with a cold cathode ionization gauge carried to the moon by Apollo 14. The vacuum quality at the landing site is much influenced by the adsorption of rocket gases and their later release. During surface operations by the astronauts, the pressure was near 10 to the minus 8th torr. No data were obtained between the time of the surface operations and lunar sunset about 12 days later, at which time the temperature fell rapidly to the vicinity of 100 K. The pressure was about 10 to the minus 12th torr shortly after sunset, but intermittent releases of gas, perhaps from within the moon itself, occasionally raised the pressure by less than an order of magnitude for as long as a day or two at a time and on one occasion to about 10 to the minus 10th torr for about an hour. At lunar sunrise, as the surface was warmed rapidly to about 300 K, the pressure rose rapidly to about 10 to the minus 10th torr, most likely due to the release of absorbed gases in the immediate landing area or on the landing module itself. For comparison with interplanetary vacuum conditions, the directed pressure of the solar wind is usually less than 10 to the minus 11th torr and the pressure of random gas motion within the solar wind, less than 10 to the minus 13th torr.

Johnson, F. S.↗

Flux Jacobian Matrices For Equilibrium Real Gases

Improved formulation includes generalized Roe average and extension to three dimensions. Flux Jacobian matrices derived for use in numerical solutions of conservation-law differential equations of inviscid flows of ideal gases extended to real gases. Real-gas formulation of these matrices retains simplifying assumptions of thermodynamic and chemical equilibrium, but adds effects of vibrational excitation, dissociation, and ionization of gas molecules via general equation of state.

Vinokur, Marcel↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment

Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

Martin, James J.↗

u-Spec Spectrometers for the EXCLAIM Instrument

The EXperiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases, and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM’s cryogenic telescope features sixμ-Spec spectrometers.μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from420−540 GHz with a resolving power R=λ/∆λ= 512, and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2×10−18W/√Hz (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9◦half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.

EXCLAIM Instrument↗

A long-term change of the AR/KR/XE fractionation in the solar corpuscular radiation

Solar noble gases in an ilmenite separate from breccia 79035 (antiquity greater than 1 Ga) were analyzed by closed system stepped etching (CSSE). All five gases show the familiar two-component structure: first solar-wind (SW) gases are released, followed by gases from solar energetic particles (SEP). Element patterns in 79035 are similar to those of 71501 ilmenite. SW-He-Ne were partly lost, but SEP-He-Ne-Ar are retained (nearly) unfractionated. Constant Ar/Kr/Xe ratios indicate that ilmenites contain an unfractionated sample of the heavy SW-SEP noble gases. Ar/Kr/Xe ratios in the solar corpuscular radiation are, however, different from 'solar system' values, whereby the Kr/Xe difference in 79035 is about twice as large as in 71501. We propose that Xe is less fractionated than Kr and Ar, though its first ionization potential (FIP) is higher than the 'cutoff' at approximately 11.5 eV, above which all elements in SEP are usually assumed to be depleted by a roughly constant factor. SW-Ne may be isotopically slightly heavier in the ancient SW trapped by 79035, as proposed earlier. In this work we extend our previous CSSE studies of solar noble gases including Kr and Xe to a lunar sample irradiated at least 1 Ga ago (breccia 79035, ilmenite separate, 42-64 microns). This sample was particularly gently etched in the first steps. Surprisingly, the first three steps, each releasing less than or equal to 0.5% of the total 36-Ar, showed an SEP-like trapped component plus relatively large concentrations of cosmogenic gases. Steps 4ff contain much less cosmogenic and more solar gas with a SW-like isotope pattern. Thus, a very minor easily etchable phase that has completely lost its SW-gases must be responsible for steps 1-3. We will not discuss these steps here and refer to the actual step 4 as the 'initial' etching step.

Wieler, R.↗

A pyroloysis technique for determining microamounts of hydrogen in lunar soil using the helium ionization detector

A method has been developed which will determine hydrogen in sub-milligram samples of lunar soil. It consists of heating the sample in a pyroprobe followed by the gas chromatographic determination of hydrogen using the helium ionization detector. Using a 7 foot, 1/8 OD stainless steel column packed with Carbosieve S, 120/140 mesh, hydrogen was well-separated from the other gases released from lunar soil. Standards of hydrogen in helium were used for calibration. The limit to detection under the conditions used was about 2 ng. The method was linear from 2 ng to 270 ng. The method was checked using some actual lunar samples. Results were typical of those obtained for lunar soils using other methods.

Bustin, R.↗

Pre- and main-sequence evolution of solar activity

The magnetic activity on single solarlike stars declines with stellar age. This has important consequences for the influence of the sun on the early solar system. What is meant by stellar activity, and how it is measured, is reviewed. Stellar activity on the premain-sequence phase of evolution is discussed; the classical T Tauri stars do not exhibit solarlike activity, while the naked T Tauri stars do. The emission surface fluxes of the naked T Tauri stars are similar to those of the youngest main-sequence G stars. The best representation for solarlike stars is a decay proportional to exp(A x t exp 0.5), where A is a function of line excitation temperature. From these decay laws, one can determine the interdependences of the activity, age, and rotation periods. The fluxes of ionizing photons at the earth early in its history are discussed; there was sufficient fluence to account for the observed isotopic ratios of the noble gases.

Walter, Frederick M.↗

A Survey of Electron Impact Cross-Sections for Halogens and Halogen Compounds of Interest to Plasma Processing

Published electron impact cross section data on halogens Cl2, F2, and halogen containing compounds such as Cx Fy, HCl, Cx Cly Fz are reviewed and critically evaluated based on the information provided by various researchers. The present work reports data on electron impact excitation, ionization, dissociation, electron attachment, electron detachment, and photo detachment. Elastic scattering cross sections and data on bulk properties such as diffusion coefficients in various background gases are also evaluated. Since some of the cross sectional data is derived from indirect measurements such as drift velocity, care has been taken to reconcile the differences among the reported data with due attention to the measurement technique. In conclusion, the processes with no or very limited amount of data and questionable set of data are identified and recommendation for further research direction is made.

Sharma, S. P.↗

The open-source neutral-mass spectrometer on Atmosphere Explorer-C, -D, and -E.

The open-source mass spectrometer will be used to obtain the number densities of the neutral atmospheric gases in the mass range 1 to 48 amu at the satellite location. The ion source has been designed to allow gas particles to enter the ionizing region with the minimum practicable number of prior collisions with surfaces. This design minimizes the loss of atomic oxygen and other reactive species due to reactions with the walls of the ion source. The principal features of the open-source spectrometer and the laboratory calibration system are discussed.