Search NASA⌕ Search

SEARCH · Search NASA

Results for “LUMINESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On the Hunt for Detectable Biosignatures in Jezero Crater: What to Look for and Where

Introduction: The Perseverance rover, which is currently exploring Jezero crater on Mars, is equipped with seven instruments that allow for observation of textures, minerals, color, structure, and chemistry of rocks and sediments in order to search for signs of ancient life, understand the geologic history of the crater, and identify candidates for sample return (Farley et al. 2020). The first of these aims includes the direct detection of potential biosignatures, including textures, organic molecules, minerals, and elemental chemistries that are of biogenic origin (Mustard et al. 2013). The presence of these biosignatures will be constrained by the habitability of the local region, the preservation potential of the host rocks, and the sensitivity of the instrument suite, and their biogenicity will be investigated after return to Earth as part of the Mars Sample Return campaign. Here, we examine key targets on the three planned campaigns, potential biosignatures that may be present, and the capabilities of key rover instruments. High Potential Biosignature Sites in Jezero: To date, measurements have been made on multiple sites that both contain minerals known in terrestrial settings to preserve biosignatures and likely were habitable settings (Williford et al. 2021). Two examples include the fine-grained rocks at the base of the delta fan and the NW inner margin of the crater. Fine-grained Rocks at Base of Delta Fan. Fine-grained, clay-bearing rocks may have been deposited as muddy lake sediments that could have hosted life and preserved biosignatures settling out of the water column. The report of organic molecules by the Curiosity rover in the Sheepbed mudstone and Murray formation has highlighted this site in particular. Potential biosignatures in mudstones, especially those rich in silica (McMahon et al. 2018), microbialites and complex organics. NW Inner Margin of Crater. This unit, located along the inner margin of the crater, contains strong carbonate signatures and may have been the littoral zone of a lake (Horgan et al. 2020). The potential biosignatures here include microfossils, microbialites, biominerals, and complex organics. Detectability of Biosignatures by the Mars 2020 Instrument Suite: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument comprises a Deep UV spectrometer, context imager, and color camera to generate spatially resolved chemical maps (Bhartia et al. 2020). It is sensitive to trace organics as well as a range of minerals and can detect native fluorescence from aromatic organics; the WATSON and ACI cameras can be used to observe morphologies such as stromatolitic laminations or filaments ranging from the tens of micron to millimeter scale. SHERLOC can detect organics that may be present in either of the high potential biosignature targets, as well as detect carbonates in the latter. However, the presence of high amounts of iron, such as in iron-rich clays, would cause attenuation of spectral response through UV absorption. The Planetary Instrument for X-ray Lithochemistry (PIXL) comprises an X-ray fluorescence spectrometer and camera that can scan rock surfaces to generate elemental maps (Allwood et al. 2020). PIXL can detect chemical biosignatures such as spatial variations of elemental abundances that may have resulted from biological activity. PIXL would be particularly useful in detecting fine textures and elemental chemistries in either high potential biosignature target, but cannot directly detect minerals such as carbonate. The SuperCam instrument performs three types of spectroscopy, color imaging, and acoustic recording to remotely examine elemental composition, minerals, organics, and textures (Maurice et al. 2021). Using laser induced breakdown spectroscopy and time resolved luminescence spectroscopy, SuperCam can detect major elemental building blocks of organics (i.e., C, H, N, O, P, S) and conjugated organic structures, respectively, which may be found in either site. While in other contexts, luminescence is a useful tool for biosignature identification, luminescence generated by the 532 nm laser may obscure the Raman signal. Conclusion: The three instruments discussed can be used collaboratively to establish the presence of potential biosignatures in samples. These high-priority samples may then be returned to Earth for detailed laboratory analysis.

S. Sharma↗

Testing the Fraunhofer line discriminator by sensing fluorescent dye

The experimental Fraunhofer Line Discriminator (FLD) has detected increments of Rhodamine WT dye as small as 1 ppb in 1/2 meter depths. It can be inferred that increments considerably smaller than 1 ppb will be detectable in depths considerably greater than 1/2 meter. Turbidity of the water drastically reduces luminescence or even completely blocks the transmission of detectable luminescence to the FLD. Attenuation of light within the water by turbidity and by the dye itself are the major factors to be considered in interpreting FLD records and in relating luminescence coefficient to dye concentration. An airborne test in an H-19 helicopter established feasibility of operating the FLD from the aircraft power supply, and established that the rotor blades do not visibly affect the monitoring of incident solar radiation.

Stoertz, G. E.↗

Hibonite, Ca2/Al, Ti/24O38, from the Leoville and Allende chondritic meteorites.

Hibonite was discovered in light-colored, Ca-Al-Ti-rich and Si-Fe-poor, achondritic inclusions of the Leoville and Allende HL-group chondrites. Two varieties of hibonite occur: one emits a bright red-orange luminescence under electron bombardment and has high amounts of Al2O3 (87.7; 87.9) and low amounts of MgO (0.65; 0.8) and TiO2 (0.68; 0.8). The other emits a bright blue luminescence and is low in Al2O3 (78.7; 79.2) and high in MgO (3.3; 3.7) and TiO2 (6.5; 7.9) (in wt. %). The oxide CaO is about the same in both varieties. It is suggested that the change in the color of the visible luminescence results from changes in composition. The origin of hibonite which occurs in complex mineral assemblages together with anorthite, gelhenite, wollastonite, aluminous diopside, andradite, Ca-pyroxene, perovskite, spinel, taenite, chromite, and pentlandite, and in close proximity to nodules containing calcite, whewellite, forsterite and many of the aforementioned phases, is discussed. The proposition that hibonite and associated phases originated by contact metamorphism and metasomatism of calcite-dolomite bearing assemblages cannot, at this time, be completely ruled out.

Keil, K.↗

Ion microprobe, electron microprobe and cathodoluminescence data for Allende inclusions with emphasis on plagioclase chemistry

Three Type B inclusions from the Allende meteorite have been analyzed. A grain-to-grain characterization of mineral chemistry and isotopic content was made possible by the use of a range of techniques, including luminescence and scanning electron microscopy and electron and ion microprobe analysis. Cathodoluminescence was used in fine-grained, optically opaque regions to distinguish between sub-micrometer phases, such as garnet and Si-rich material, subsequently identified by electron probe and scanning electron microscope analyses. Four types of luminescence patterns, due to twinning, primary sector zoning, alteration of boundaries and fractures, and shock effects, were identified in Allende plagioclase. Luminescence color exhibited a strong correlation with Mg content and provided a guide for an electron probe quantitative map of Mg and Na distributions. Ion microprobe studies of individual grains revealed large excesses of Mg-26.

Hutcheon, I. D.↗

Pressure-sensitive paint measurements on a supersonic high-sweep oblique wing model

The pressure-sensitive paint method was used in the test of a high-sweep oblique wing model, conducted in the NASA Ames 9- by 7-ft Supersonic Wind Tunnel. Surface pressure data was acquired from both the luminescent paint and conventional pressure taps at Mach numbers between M = 1.6 and 2.0. In addition, schlieren photographs of the outer flow were used to determine the location of shock waves impinging on the model. The results show that the luminescent pressure-sensitive paint can capture both global and fine features of the static surface pressure field. Comparison with conventional pressure tap data shows good agreement between the two techniques, and that the luminescent paint data can be used to make quantitative measurements of the pressure changes over the model surface. The experiment also demonstrates the practical considerations and limitations that arise in the application of this technique under supersonic flow conditions in large-scale facilities, as well as the directions in which future research is necessary in order to make this technique a more practical wind-tunnel testing tool.

McLachlan, B. G.↗

Fluorescence of Pentavalent Chromium in SiO2 Sol-Gel Glasses

Chromium ions are very attractive to optical spectroscopy and laser physics. It is well known that the first laser in the history is a ruby laser activated with Cr(3+). It was found in early nineties that Cr(4+) was also an interesting lasing ion in the near infrared, and various Cr(4+) lasers have been developed. Very recently, it was reported that Cr(2+) doped in CdSe crystals showed lasing action in the infrared. The above achievement have stimulated an interest in searching for Cr(5+) and investigating its optical properties. Cr(5+) is isoelectronic with Ti(3+) and V(4+), having electron configuration 3d1. Ti(3+) is the active center of commercial cw and femtosecond sapphire lasers, tunable in the range 680-1100 nm. V(4+) doped in YAlO3 and Al2O3 showed broad band emission near 635 nm. Although EPR results of Cr(5+) were reported, the optical properties were less studied. Herren et al. reported an observation of luminescence from Cr doped in SiO2 sol-gel glass. The luminescence spectrum was assigned to pentavalent ions in their first paper, and later it was identified to be the emission from the charge transfer transition of Cr(6+). The first observation of photoluminescence from octahedrally coordinated Cr(5+) in BaCaMg aluminate glasses was reported very recently. In this work, we report luminescence results of Cr doped SiO2 sol-gel glasses. The fluorescence spectra are very different from Herrens' results, and we believe it originates from pentavalent Cr.

Jia, Weiyi↗

Using Temperature Sensitive Paint Technology

New facilities and test techniques afford research aerodynamicists many opportunities to investigate complex aerodynamic phenomena. For example, NASA Langley Research Center's National Transonic Facility (NTF) can hold Mach number, Reynolds number, dynamic pressure, stagnation temperature and stagnation pressure constant during testing. This is important because the wing twist associated with model construction may mask important Reynolds number effects associated with the flight vehicle. Beyond this, the NTF's ability to vary Reynolds number allows for important research into the study of boundary layer transition. The capabilities of facilities such as the NTF coupled with test techniques such as temperature sensitive paint yield data that can be applied not only to vehicle design but also to validation of computational methods. Development of Luminescent Paint Technology for acquiring pressure and temperature measurements began in the mid-1980s. While pressure sensitive luminescent paints (PSP) were being developed to acquire data for aerodynamic performance and loads, temperature sensitive luminescent paints (TSP) have been used for a much broader range of applications. For example, TSP has been used to acquire surface temperature data to determine the heating due to rotating parts in various types of mechanical systems. It has been used to determine the heating pattern(s) on circuit boards. And, it has been used in boundary layer analysis and applied to the validation of full-scale flight performance predictions. That is, data acquired on the same model can be used to develop trends from off design to full scale flight Reynolds number, e.g. to show the progression of boundary layer transition. A discussion of issues related to successfully setting-up TSP tests and using TSP systems for boundary layer studies is included in this paper, as well as results from a variety of TSP tests. TSP images included in this paper are all grey-scale so that similar to pictures from sublimating chemical tests areas of laminar flow appear "lighter," or white, and areas of turbulent flow appear "darker."

Hamner, M. P.↗

Diffusion Time-Scale of Porous Pressure-Sensitive Paint

Pressure-sensitive paint (PSP) is an optical pressure sensor that utilizes the oxygen quenching of luminescence. PSP measurements in unsteady aerodynamic flows require fast time response of the paint. There are two characteristic time-scales that are related to the time response of PSP. One is the luminescent lifetime representing an intrinsic physical limit for the achievable temporal resolution of PSP. Another is the time-scale of oxygen diffusion across the PSP layer. When the time-scale of oxygen diffusion is much larger than the luminescent lifetime, the time response of PSP is controlled by oxygen diffusion. In a thin homogenous polymer layer where diffusion is Fickian, the oxygen concentration 1021 can be described by the diffusion equation in one-dimension.

Liu, Tianshu↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of micro-fabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. This paper will focus on description of the development of the instrument.

Wilcox, J. Z.↗

Nanorod-Based Fast-Response Pressure-Sensitive Paints

A proposed program of research and development would be devoted to exploitation of nanomaterials in pressuresensitive paints (PSPs), which are used on wind-tunnel models for mapping surface pressures associated with flow fields. Heretofore, some success has been achieved in measuring steady-state pressures by use of PSPs, but success in measuring temporally varying pressures has been elusive because of the inherent slowness of the optical responses of these materials. A PSP contains a dye that luminesces in a suitable wavelength range in response to photoexcitation in a shorter wavelength range. The luminescence is quenched by oxygen at a rate proportional to the partial pressure of oxygen and thus proportional to the pressure of air. As a result, the intensity of luminescence varies inversely with the pressure of air. The major problem in developing a PSP that could be easily applied to a wind-tunnel model and could be useful for measuring rapidly varying pressure is to provide very high gas diffusivity for rapid, easy transport of oxygen to and from active dye molecules. Most PSPs include polymer-base binders, which limit the penetration of oxygen to dye molecules, thereby reducing responses to pressure fluctuations. The proposed incorporation of nanomaterials (somewhat more specifically, nanorods) would result in paints having nanostructured surfaces that, relative to conventional PSP surfaces, would afford easier and more nearly complete access of oxygen molecules to dye molecules. One measure of greater access is effective surface area: For a typical PSP as proposed applied to a given solid surface, the nanometer-scale structural features would result in an exposed surface area more than 100 times that of a conventional PSP, and the mass of proposed PSP needed to cover the surface would be less than tenth of the mass of the conventional PSP. One aspect of the proposed development would be to synthesize nanorods of Si/SiO2, in both tangle-mat and regular- array forms, by use of chemical vapor deposition (CVD) and wet chemical processes, respectively. The rods would be coated with a PSP dye, and the resulting PSP signals would be compared with those obtained from PSP dye coats on conventional support materials. Another aspect of the proposed development would be to seek to exploit the quantum properties of nanorods of a suitable semiconductor (possibly GaN), which would be synthesized by CVD. These quantum properties of semiconductor nanorods include narrow-wavelength-band optical absorption and emission characteristics that vary with temperature. The temperature sensitivity might enable simultaneous measurement of fluctuating temperature and pressure and to provide a temperature correction for the PSP response.

Bencic, Timothy↗

Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space

Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.

Delgado, Jesus↗

Continued Development of Compact Multi-gas Monitor for Life Support Systems Control in Space

Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to Near-Infrared-based gas sensor systems for the advanced space suit portable life support system (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. This paper presents the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.

Delgado-Alonso, Jesús↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗

Identifying Shocked Feldspar on Mars Using Perseverance Spectroscopic Instruments: Implications for Geochronology Studies on Returned Samples

The Perseverance rover (Mars 2020) mission, the first step in NASA’s Mars Sample Return (MSR) program, will select samples for caching based on their potential to improve understanding Mars’ astrobiological, geological, geochemical, and climatic evolution. Geochronologic analyses will be among the key measurements planned for returned samples. Assessing a sample’s shock history will be critical because shock metamorphism could influence apparent sample age. Shock effects in one Mars-relevant mineral class, plagioclase feldspar, have been well- documented using various spectroscopy techniques (thermal infrared reflectance, emission, and transmission spectroscopy, Raman, and luminescence). A subset of these data will be obtained with the SuperCam and SHERLOC (Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals) instruments onboard Perseverance to inform caching decisions for MSR. Here, we review shock indicators in plagioclase feldspar as revealed in Raman, luminescence, and IR spectroscopy lab data, with an emphasis on Raman spectroscopy. We consider how this information may inform caching decisions for selecting optimal samples for geochronology measurements. We then identify challenges and make recommendations for both in situ measurements performed with SuperCam and SHERLOC and for supporting lab studies to enhance the success of geochronologic analyses after return to Earth.

mars↗

Implementation of an Ultra-Bright Thermographic Phosphor for Gas Turbine Engine Temperature Measurements

The overall goal of the Aeronautics Research Mission Directorate (ARMD) Seedling Phase II effort was to build on the promising temperature-sensing characteristics of the ultrabright thermographic phosphor Cr-doped gadolinium aluminum perovskite (Cr:GAP) demonstrated in Phase I by transitioning towards an engine environment implementation. The strategy adopted was to take advantage of the unprecedented retention of ultra-bright luminescence from Cr:GAP at temperatures over 1000 C to enable fast 2D temperature mapping of actual component surfaces as well as to utilize inexpensive low-power laser-diode excitation suitable for on-wing diagnostics. A special emphasis was placed on establishing Cr:GAP luminescence-based surface temperature mapping as a new tool for evaluating engine component surface cooling effectiveness.

temperature↗

Temperature Mapping Above and Below Thermal Barrier Coatings Using Phosphor Thermometry

Luminescence lifetime imaging was obtained from thin Er-doped yttria-stabilized zirconia (YSZ:Er) layers integrated into either the top or bottom of thermal barrier coatings (TBCs) to produce temperature maps from either the TBC surface or from the TBC/substrate interface. Temperature mapping was combined with luminescence intensity-based delamination monitoring to quantitatively assess the degradation of thermal protection associated with localized TBC delamination. Temperature mapping of either the TBC surface or TBC/substrate interface during air film cooling was also performed to evaluate the effectiveness of air film cooling both at the TBC surface as well as the cooling effectiveness at the TBC/substrate interface.

phosphor thermometry↗

Temperature Sensing to Above 1500 °C Using Y 2 SiO 5 :Er Phosphor Thermometry

A transition from metallic to ceramic turbine components that can operate at higher turbine engine temperatures will push component surface temperatures from below 1200 °C into a 1300 to 1500 °C temperature range that is much more challenging for phosphor thermometry measurements. To address this challenge, Y 2 SiO 5 :Er was selected for its high temperature sensing performance by both luminescence lifetime and luminescence intensity ratio (LIR) methods as well as its thermochemical compatibility with the current generation of rare earth silicate environmental barrier coatings (EBCs) that are required to protect SiC/SiC ceramic composite components. Lifetime measurements that monitor the Er3+ 4S3/2→4I15/2 emission decay at 542 nm exhibited a slow decrease in decay time with temperature up to 1300° C, above which the decay decreased steeply to provide good temperature sensitivity in the 1300 to 1500 °C range (Fig. 1). LIR images were obtained where each pixel represented the ratio I488/I561 (I488 and I561 are the detected 488 nm 4F7/2→4I15/2 and the 561 nm 4S3/2→4I15/2 emission band intensities, respectively). Good temperature sensitivity (Fig. 2) and signal-to-background ratios were observed to above 1500 °C. Contrary to conventional guidance on selecting phosphors for high temperature sensing, the detected emission band intensities and decay times exhibited remarkably slow decreases with temperature up into the 1300 to 1500 °C range despite high phonon energies (>900 cm-1) that allow the energy gap between the 4S3/2 emitting reservoir level and the 4F9/2 level below it to be bridged by as few as three phonons. The benefits of utilizing a thermographic phosphor at very high temperatures that exhibits strong nonradiative multiphonon relaxation even at room temperature is explained by a competition between spontaneous and stimulated multiphonon emission, and the more temperature-sensitive decay time above 1300 °C is explained by a transition from high to low effective phonon energies.

temperature measurement↗

Environmental Barrier Coating Surface Temperature Mapping Using a Compatible Er-Doped Sc 2 SiO 5 Temperature-Sensing Layer

Accurate surface temperature-mapping capabilities in the 1300 to 1500 °C range are needed for SiC/SiC ceramic matrix composites protected by environmental barrier coatings (EBCs) under testing in turbine engine environment facilities. The strong background thermal radiation at these higher temperatures is a challenging issue. Er-doped Y 2 SiO 5 was previously shown to be capable of achieving luminescence lifetime-based temperature mapping up to 1560 °C as a standalone material. However, compatibility issues between an Er-doped Y 2 SiO 5 surface temperature sensing layer and an underlying Sc 2 Si 2 O 7 -based EBC topcoat limited temperature mapping of the EBC surface to a maximum of 1380 °C. Therefore, an Er-doped Sc 2 SiO 5 temperature sensing layer has been subsequently developed with better compatibility with the Sc2Si2O7-based EBC topcoat. Localized spot temperature measurements as well as luminescence lifetime imaging-based temperature mapping were demonstrated up to 1535 °C from a 15 µm thick Er-doped Sc 2 SiO 5 layer at the surface of a Sc2Si2O7-based EBC topcoat, a significant improvement over the Er-doped Y2SiO5 layer 1380 °C temperature sensing limit. No degradation of the Er-doped Sc 2 SiO 5 temperature sensing surface layer was observed.

temperature measurement↗