At least 235 records · Page 13

Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

Kilbane, J.↗

Probing the Magnetic Causes of CMEs: Free Magnetic Energy More Important Than Either Size Or Twist

To probe the magnetic causes of CMEs, we have examined three types of magnetic measures: size, twist and total nonpotentiality (or total free magnetic energy) of an active region. Total nonpotentiality is roughly the product of size times twist. For predominately bipolar active regions, we have found that total nonpotentiality measures have the strongest correlation with future CME productivity (approx. 75% prediction success rate), while size and twist measures each have a weaker correlation with future CME productivity (approx. 65% prediction success rate) (Falconer, Moore, & Gary, ApJ, 644, 2006). For multipolar active regions, we find that the CME-prediction success rates for total nonpotentiality and size are about the same as for bipolar active regions. We also find that the size measure correlation with CME productivity is nearly all due to the contribution of size to total nonpotentiality. We have a total nonpotentiality measure that can be obtained from a line-of-sight magnetogram of the active region and that is as strongly correlated with CME productivity as are any of our total-nonpotentiality measures from deprojected vector magnetograms. We plan to further expand our sample by using MDI magnetograms of each active region in our sample to determine its total nonpotentiality and size on each day that the active region was within 30 deg. of disk center. The resulting increase in sample size will improve our statistics and allow us to investigate whether the nonpotentiality threshold for CME production is nearly the same or significantly different for multipolar regions than for bipolar regions. In addition, we will investigate the time rates of change of size and total nonpotentiality as additional causes of CME productivity.

Falconer, D. A.↗

Composition changes and empirical models

Empirical model descriptions of the response of the neutral thermosphere to magnetic activity have become increasingly sophisticated over the last two decades. The latest CIRA model (MSIS-86) includes a dependence of the thermospheric response to magnetic activity on altitude, latitude, local time, season, longitude, UT, and time history of magnetic activity. A primary assumption is that density changes are directly related to the measured magnetic activity and the goal is for the model to be representative of the typical or average response for any given level of magnetic activity under specified ancillary conditions. Unfortunately, available measurements for the larger storms are too sparse to give good averages and storm response may not be uniquely represented by current magnetic indices. Point by point comparisons with the MSIS-86 model have standard deviations of 20 percent for 0 and 30 percent for N2 and He at high latitudes during storm conditions.

Hedin, A. E.↗

Cluster electric current density measurements within a magnetic flux rope in the plasma sheet

On August 22, 2001 all 4 Cluster spacecraft nearly simultaneously penetrated a magnetic flux rope in the tail. The flux rope encounter took place in the central plasma sheet, Beta(sub i) approx. 1-2, near the leading edge of a bursty bulk flow. The "time-of-flight" of the flux rope across the 4 spacecraft yielded V(sub x) approx. 700 km/s and a diameter of approx.1 R(sub e). The speed at which the flux rope moved over the spacecraft is in close agreement with the Cluster plasma measurements. The magnetic field profiles measured at each spacecraft were first modeled separately using the Lepping-Burlaga force-free flux rope model. The results indicated that the center of the flux rope passed northward (above) s/c 3, but southward (below) of s/c 1, 2 and 4. The peak electric currents along the central axis of the flux rope predicted by these single-s/c models were approx.15-19 nA/sq m. The 4-spacecraft Cluster magnetic field measurements provide a second means to determine the electric current density without any assumption regarding flux rope structure. The current profile determined using the curlometer technique was qualitatively similar to those determined by modeling the individual spacecraft magnetic field observations and yielded a peak current density of 17 nA/m2 near the central axis of the rope. However, the curlometer results also showed that the flux rope was not force-free with the component of the current density perpendicular to the magnetic field exceeding the parallel component over the forward half of the rope, perhaps due to the pressure gradients generated by the collision of the BBF with the inner magnetosphere. Hence, while the single-spacecraft models are very successful in fitting flux rope magnetic field and current variations, they do not provide a stringent test of the force-free condition.

Slavin, J. A.↗

Comprehensive evaluation of attitude and orbit estimation using real earth magnetic field data

A single, augmented extended Kalman filter (EKF) which simultaneously and autonomously estimates spacecraft attitude and orbit was developed and tested with simulated and real magnetometer and rate data. Since the earth's magnetic field is a function of time and position, and since time is accurately known, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft's orbit, are a function of orbit and attitude errors. These differences can be used to estimate the orbit and attitude. The test results of the EKF with magnetometer and gyro data from three NASA satellites are presented and evaluated.

Deutschmann, Julie↗

Intrinsic Magnetic Properties of the Lunar Body

Preliminary analysis of magnetic measurements by Explorer 35 in lunar orbit suggested an upper limit of 4 x 10(exp 20) gauss-cm3 for the magnetic moment of the moon. A more detailed analysis of a larger body of Explorer 35 data from measurements in the earth's magnetic tail has subsequently been performed. Reversal of the ambient tail field by 180deg when the moon and spacecraft traverse the neutral sheet permits a separation of permanent and induced field contributions to the total field observed near the moon. When compared to calculated permanent and induced field effects, the results of this analysis lead to new upper limits of 102' gauss-cm3 on the lunar magnetic moment and 4y on the lunar surface field. Limiting the moment induced in the moon by the magnetotail field permits an upper limit of 1.8 to be set on the bulk relative magnetic permeability of the moon.

Behannon, Kenneth W.↗

Attitude and Trajectory Estimation Using Earth Magnetic Field Data

The magnetometer has long been a reliable, inexpensive sensor used in spacecraft momentum management and attitude estimation. Recent studies show an increased accuracy potential for magnetometer-only attitude estimation systems. Since the Earth's magnetic field is a function of time and position, and since time is known quite precisely, the differences between the computer and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft orbit, are a function of both the spacecraft trajectory and attitude errors. Therefore, these errors can be used to estimate both trajectory and attitude. Traditionally, satellite attitude and trajectory have been estimated with completely separate system, using different measurement data. Recently, trajectory estimation for low earth orbit satellites was successfully demonstrated in ground software using only magnetometer data. This work proposes a single augmented extended Kalman Filter to simultaneously and autonomously estimate both spacecraft trajectory and attitude with data from a magnetometer and either dynamically determined rates or gyro-measured body rates.

Deutschmann, Julie↗

Comprehensive Evaluation of Attitude and Orbit Estimation Using Actual Earth Magnetic Field Data

A single, augmented Extended Kalman Filter (EKF), which simultaneously and autonomously estimates spacecraft attitude and orbit has been developed and successfully tested with real magnetometer and gyro data only. Because the earth magnetic field is a function of time and position, and because time is known quite precisely, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft orbit, are a function of both orbit and attitude errors. Thus, conceivably these differences could be used to estimate both orbit and attitude; an observability study validated this assumption. The results of testing the EKF with actual magnetometer and gyro data, from four satellites supported by the NASA Goddard Space Flight Center (GSFC) Guidance, Navigation, and Control Center, are presented and evaluated. They confirm the assumption that a single EKF can estimate both attitude and orbit when using gyros and magnetometers only.

Deutschmann, Julie K.↗

Polarimetry of the HI Lyman-alpha for coronal magnetic field diagnostics

We discuss and analyze the possible sources of observational and instrumental uncertainty that can be encountered in measuring magnetic fields of the solar corona through polarimetric observations of the Hanle effect of the coronal Ly-alpha line. The Hanle effect is the modification of the linear polarization of a resonantly scattered line, due to the presence of a magnetic field. Simulated observations are used to examine how polarimetric measurements of this effect are affected by the line-of-sight integration, the electron collisions, and the Ly-alpha geocorona. We plan to implement the coronal magnetic field diagnostics via the Ly-alpha Hanle effect using an all-reflecting Ly-alpha coronagraph/polarimeter (Ly-alphaCoPo) which employs reflecting multilayer mirrors, polarizers, and filters. We discuss here the requirements for such an instrument, and analyze the sources of instrumental uncertainty for polarimetric observations of the coronal Ly-alpha Hanle effect. We conclude that the anticipated polarization signal from the corona and the expected performance of the Ly-alphaCoPo instrument are such that the Ly-alpha Hanle effect method for coronal field diagnostics is feasible.

Fineschi, Silvano↗

Development of New Research-Quality Low-Resource Magnetometers for Small Satellites

Researchers from the University of Michigan (UM) and NASA Goddard Spaceflight Center (GSFC) are partnering to develop new types of magnetometers for use on future small satellites. These new instruments not only fulfill stringent requirements for low-amplitude and high-precision measurements, they are also enabling the team to develop a new approach to achieve high-quality magnetic measurements from space, without the need for a boom. Typically, space-based magnetometers are deployed on a boom that extends from the space vehicle to reduce exposure of magnetic noise emanating from the spacecraft, which could potentially contaminate measurements. The UMNASA team has developed algorithms to identify and eliminate spacecraft magnetic noise, which will allow placement of these economical, science-grade instrument magnetometers on and inside the satellite bus, instead of on a boom.

Small Spacecraft↗

A low energy electron magnetometer

The concept of a highly sensitive magnetometer based on the deflection of low energy electron beams in magnetic fields is analyzed. Because of its extremely low mass and consequently high e/m ratio, a low energy electron is easily deflected in a magnetic field, thus providing a basis for very low field measurement. Calculations for a specific instrument design indicate that a low energy electron magnetometer (LEEM) can measure magnetic fields as low as 1000 nT. The anticipated performance of LEEM is compared with that of the existing high resolution magnetometers in selected applications. The fast response time of LEEM makes it especially attractive as a potential instrument for magnetic signature analysis in large engineering systems.

Singh, J. J.↗

Evolution of vector magnetic fields and the August 27 1990 X-3 flare

Vector magnetic fields in an active region of the sun are studied by means of continuous observations of magnetic-field evolution emphasizing magnetic shear build-up. The vector magnetograms are shown to measure magnetic fields correctly based on concurrent observations and a comparison of the transverse field with the H alpha fibril structure. The morphology and velocity pattern are examined, and these data and the shear build-up suggest that the active region's two major footprints are separated by a region with flows, new flux emergence, and several neutral lines. The magnetic shear appears to be caused by the collision and shear motion of two poles of opposite polarities. The transverse field is shown to turn from potential to sheared during the process of flux cancellation, and this effect can be incorporated into existing models of magnetic flux cancellation.

Wang, Haimin↗

Zeeman observations of W Sgr

A new precise method for measuring magnetic fields on Zeeman plates of the southern Cepheid 'W Sgr' is reviewed. Ten plates over the 7.6(d) period of pulsation show two extrema in the measured values of the effective magnetic field. The method has a precision of + or - 0.4 microns in the Zeeman shift corresponding to + or - 50 Gauss (g). A negative spike of -220 g occurred at the time of arrival of the compressional wave of pulsation at the stellar surface. A positive field of +270 g occurred at the phase of most rapid contraction near the temperature minimum of the pulsation cycle.

Wood, H. J.↗

Magsat data availability

It is pointed out that a new era in near-earth magnetic field measurements began with NASA's launch of Magsat in October 1979 into a twilight, sun-synchronous orbit with 96.76 deg inclination, 561-km apogee, and 352-km perigee. A cesium vapor and a fluxgate magnetometer were employed to measure the magnetic field. A measurement of the spacecraft attitude to 20 arcseconds was required to achieve 6 nT (nanotesla) accuracy in the component measurements. This was accomplished with the aid of two star cameras on board the spacecraft and a sun sensor attached to the vector magnetometer. Magsat remained in orbit until June 11, 1980. Magsat has conducted the first truly global geomagnetic survey since the studies performed by the Polar Orbiting Geophysical Observatory (POGO) satellites. A global vector survey was provided of the main geopotential field and lower altitude measurements of crustal anomalies were conducted. Details concerning the availability of these data are discussed.

Langel, R. A.↗

Magsat: A satellite for measuring near earth magnetic fields

Magsat, designed for making measurements of the geomagnetic vector field, is evaluated. For accurate vector measurements the attitude of the fluxgate magnetometer will be determined to about 15 arc-seconds. Expected measurement accuracy will be 6 (gamma) in each component and 3 in magnitude. The Magsat data will be applied to solid earth studies including modeling of the Earth's main magnetic field, delineation of regional magnetic anomalies of crustal origin, and interpretation of those anomalies in terms of geologic and geophysical models. An opportunity will be presented to the scientific community to participate in data use investigations.

Langel, R. A.↗

Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets

A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.

Niedra, Janis M.↗