Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Lagrangian dynamics of particle transport in oral and nasal breathing

Here, we present a large-eddy simulation (LES) of saliva particle transport during normal human breathing through the nose and mouth. The flow of the air–saliva mixture is modeled using an Eulerian LES that is coupled with a Lagrangian particle tracking module to obtain trajectories of saliva particles in a room with stagnant air conditions. The coupled Eulerian–Lagrangian simulation yields novel insights into the intricate dynamics of Lagrangian coherent structures (LCS) and fundamental material lines that emerge from the saliva particles' trajectories during several breathing cycles. Further, we systematically compare the quantitative LCS diagnostics of mouth breathing with those of mouth and nose normal breathing. Analyzing the simulation results of human breathing from the mouth and nose, we show that, soon after the first breathing cycle, saliva particles form a series of roll-up vortex rings that propagate forward. The forward propagation of these vortex rings leads to the formation of an asymmetrical primary forefront vortex. The individual vortex rings continuously propagate forward, merging with the forefront vortex, and ascending along the limb of the leading vortex.

42 ENGINEERING↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Ultrafast Surface Phosphor Thermometry for Pulsed-power and Hostile Environments

Modern concepts for next generation pulsed power (NGPP) are slated to deliver up to ten times the energy of Z today. An increase of this magnitude is concerning insofar that Z currently exhibits sizable amounts of inner magnetically insulated transmission line (MITL) loss current on the order of 5-10%. Loss phenomenon in these systems are complex and electrode heating and subsequent thermal desorption are a leading cause. Rapid heat-driven thermal desorption of contaminants scales as the square of the current. Therefore, even a modest doubling of drive current would yield an ~ 4X in non-linear surface electrode heating, quickening thermal desorption-based current loss. Exacerbating these physics is a current inability to measure ultra fast heating rates (>20°C/ns), which are paramount to benchmarking and code validation critical to NGPP design – as an empirical approach is not viable. Therefore, Ultrafast Photoluminescent Surface Heating Optical Thermometry (UP-SHOT) was developed as a new diagnostic for measurement of GHz-scale electrode heating. The discovery of UP-SHOT leveraged expertise in Engineering Science, Material Science, Pulsed-Power, and the Center for Integrated Nanotechnologies. This report includes information on: 1) The preparation of zinc oxide (ZnO) films, characterization, post-deposition treatments 2) Time-resolved photoluminescence at elevated temperatures and thermographic sensitivity

36 MATERIALS SCIENCE↗

IDAES-PSE 2.5.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.5.0 Release Highlights Upcoming Changes IDAES will be switching to the new Pyomo solver interface in the next release. Whilst this will hopefully be a smooth transition for most users, there are a few important changes to be aware of. The new solver interface uses a different version of the IPOPT writer (“ipopt_v2”) and thus any custom configuration options you might have set for IPOPT will not carry over and will need to be reset. By default, the new Pyomo linear presolver will be activated with ipopt_v2. Whilst are working to identify any bugs in the presolver, it is possible that some edge cases will remain. IDAES will begin deploying a new set of scaling tools and APIs over the next few releases that make use of the new solver writers. The old scaling tools and APIs will remain for backward compatibility but will begin to be deprecated. New Models, Tools and Features New diagnostics check for near-parallel variables and constraints. New diagnostics tools for identifying causes of infeasibility in models. New example for creating a custom model of a liquid-liquid extractor unit operation. Bug Fixes Fixed bug in Gibbs reactor that caused it to appear to have additional spurious degrees of freedom. Fixed bug in the Modular Property Framework that would cause errors when trying to use phase-based material balances with phase equilibria. Fixed bug in Modular Properties Framework that caused errors when initializing models with non-vapor-liquid phase equilibria. Testing and Robustness Deployed the IDAES Diagnostics Toolbox to confirm that there are no structural or numerical issues in the core model libraries. Additional robustness tests for core model, and some associated improvements in the converge tester class. Fixed a number of issues that were causing unexpected warnings to be emitted during testing. Deprecations and Removals Removed examples for RIPE tool which has not been supported for a number of releases.

AS↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗

Revisiting Source Convergence Diagnostics in the KENO Monte Carlo Neutron Transport Codes [Abstract]

Monte Carlo criticality transport codes, which rely on the power iteration procedure, are a fundamental tool for nuclear criticality safety practitioners in assessing the neutron multiplication factor (k eff ) for problems involving fissile material. In these calculations, ensuring the convergence of both the fission source distributions and the k eff estimate for accurate results is crucial. However, a converged k eff estimate does not necessarily mean the fission source distribution is also converged because the fission source and flux distribution may continue to evolve even after k eff convergence. Therefore, most Monte Carlo transport criticality codes now offer various diagnostic tests to assess fission source convergence in addition to the k eff convergence by analyzing the trends of these quantities over multiple generations.

AZURE↗

On the Prospect of Chemically Transferable Coarse-Grained Electronic Models for Soft Materials

Electronic coarse-graining (ECG) methods predict quantum-mechanical electronic properties directly from coarse-grained (CG) molecular configurations, enabling electronic predictions at mesoscale length scales. Here, we present a diagnostic assessment of the feasibility of chemically transferable ECG models across a broad polymer-relevant chemical space using all-atom, united-atom, and Martini-scale representations. While high-resolution ECG models achieve near-quantitative accuracy, we show that chemically transferable ECG at the Martini resolution fails because the CG force field does not sample the same configurational distribution of local molecular structure as that underlying the DFT-parameterized ECG model. We demonstrate that our proposed Element-Count-Label (ECL) representation, which augments Martini beads with explicit stoichiometric data, significantly improves chemical generalization across diverse polymer chemistries. However, we find that even with improved chemical resolution, the model cannot recover electronic property distributions that are absent from the configurational space sampled by the CG force field. These results demonstrate that chemically transferable ECG requires future Martini-like force fields to explicitly preserve quantum chemistry–compatible local molecular structure in addition to thermodynamic and structural fidelity.

Kidder, Katherine M [Department of Chemistry; Univ↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Detailed temperature diagnostic studies for Radishock and COAX experiments

Spectral diagnostics provide a powerful probe of high energy-density physics experiments. By shining an x-ray source on a target, absorption features can be used to determine accurate temperature profiles of that target material. Many studies produce a single temperature/density measurement by fitting these observed spectra. This paper demonstrates how, by leveraging detailed simulations, we can not only measure the average temperature and density, but the full density and temperature profiles. To do so, we must conduct a careful analysis of the uncertainties in the diagnostic measurement. Here we discuss the characteristics and associated uncertainties of the spectral diagnostic used in the COAX, Radishock and OuTi experiments, ultimately demonstrating how these detailed studies increase the potential of this powerful probe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrochemical Residence Time Distribution as a Diagnostic Tool for Redox Flow Batteries

The fluid dynamic and electrochemical performance of redox flow batteries (RFBs) stems from the relationship between the flow field and the porous electrode, whose interplay determines how active species move and react during device operation. While characterization techniques, such as residence time distribution, offer insights into species mobility within a reactive volume for a traditional chemical reactor, electrochemical reactors also enable simultaneous measurement of the redox reactions, unlocking another dimension of analysis. Herein, we demonstrate how potentiodynamic measurements, using injections of electrolyte examined through moment analysis, can provide electrode-specific performance scaling relationships across a matrix of carbon paper and cloth electrodes with flow through and interdigitated flow fields. We further combine experimental campaigns with multiphysics simulations to demonstrate how electrode surface area can be estimated with this technique, which we then validate with activated and unactivated commercial carbon cloth electrodes. These studies reveal the multiscale observations that potentiodynamic measurements afford, augmenting existing electrochemical techniques for holistic electrochemical reactor diagnostics.

Electrochemistry↗

AMPPED LDRD: Advanced Models of the Physics & Phenomena of Electrical Discharge.

This Laboratory Directed Research and Development (LDRD) project aimed at addressing an unmet need for physics-based models that enable prediction of electrical breakdown in the presence of high voltage gradients and real-world environments. This project focused on understanding coupled plasma-surface feedback phenomena critical to electrical discharge processes and design of breakdown voltages, breakdown times, and breakdown paths. New secondary electron emission and coupled plasma-surface measurement methods and models were developed. Highly reproducible discharge experiments were developed to provide current-voltage data as a function of time, and methods were developed to condition electrodes for predictable discharge. To assess plasma-surface feedback mechanisms, new surface physics capabilities, including measurement systems for local and global photoemission yield and ion-induced secondary electron emission yield were developed. Discharge models were developed to incorporate these yields for predicting discharge behavior to understand influence of surface physics on discharge current and time evolution, and methods to accelerate these simulations were demonstrated. A key finding was that the initiation process of a non-vacuum discharge appears highly dependent on photoemission at the cathode. Advanced diagnostics were developed, including spatial electrical field imaging, spectroscopy of plasmas, and high-speed imaging of discharge event s in metal and dielectric environments. These diagnostics and improved electrical models are a step toward enabling quantitative design margins, assurance of safety architectures, and implementation of novel materials and technologies for wide ranging energy and electronics applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manufacture of particulate reference materials

Methods for forming particulates that are highly consistent with regard to shape, size, and content are described. Particulates are suitable for use as reference materials. Methods can incorporate actinides and/or lanthanides, e.g., uranium, and can be used for forming certified reference materials for use in the nuclear industry. Methods include formation of an aerosol from an oxalate salt solution, in-line diagnostics, and collection of particles of the aerosol either in a liquid impinger or on a solid surface.

Wellons, Matthew S.↗

Advancing Battery Manufacturing: Synchrotron Characterization for Industry

Large-scale battery manufacturing requires understanding the fundamental principles of materials and interfaces and relies on advanced techniques for detailed interrogation. Despite advancements in the industrial scale production and their associated quality control tools, challenges such as electrode heterogeneity, internal defects, and largescale material waste (e.g., scrap) can hamper manufacturing. Synchrotron X-ray characterization techniques offer spatial, temporal, and chemical resolution that can provide diagnostic insights for metrology across various manufacturing steps. This review examines the use of synchrotron tools to advance understanding of key steps in the battery manufacturing process. Recent examples demonstrate how synchrotron methods resolve manufacturing challenges and uncover degradation pathways that are otherwise inaccessible. Future directions for advancing battery manufacturing emphasize collaboration between academia and industry through the use of synchrotron X-ray techniques.

Batteries↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗