Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multimodal Pilot Behavior in Multi-Axis Tracking Tasks with Time-Varying Motion Cueing Gains

In a large number of motion-base simulators, adaptive motion filters are utilized to maximize the use of the available motion envelope of the motion system. However, not much is known about how the time-varying characteristics of such adaptive filters affect pilots when performing manual aircraft control. This paper presents the results of a study investigating the effects of time-varying motion filter gains on pilot control behavior and performance. An experiment was performed in a motion-base simulator where participants performed a simultaneous roll and pitch tracking task, while the roll and/or pitch motion filter gains changed over time. Results indicate that performance increases over time with increasing motion gains. This increase is a result of a time-varying adaptation of pilots' equalization dynamics, characterized by increased visual and motion response gains and decreased visual lead time constants. Opposite trends are found for decreasing motion filter gains. Even though the trends in both controlled axes are found to be largely the same, effects are less significant in roll. In addition, results indicate minor cross-coupling effects between pitch and roll, where a cueing variation in one axis affects the behavior adopted in the other axis.

motion simulators↗

Application of an automatic cloud tracking technique to Meteosat water vapor and infrared observations

The automatic cloud tracking system was applied to METEOSAT 6.7 micrometers water vapor measurements to learn whether the system can track the motions of water vapor patterns. Data for the midlatitudes, subtropics, and tropics were selected from a sequence of METEOSAT pictures for 25 April 1978. Trackable features in the water vapor patterns were identified using a clustering technique and the features were tracked by two different methods. In flat (low contrast) water vapor fields, the automatic motion computations were not reliable, but in areas where the water vapor fields contained small scale structure (such as in the vicinity of active weather phenomena) the computations were successful. Cloud motions were computed using METEOSAT infrared observations (including tropical convective systems and midlatitude jet stream cirrus).

Endlich, R. M.↗

A study of the comparative effects of various means of motion cueing during a simulated compensatory tracking task

NASA's Langley Research Center conducted a simulation experiment to ascertain the comparative effects of motion cues (combinations of platform motion and g-seat normal acceleration cues) on compensatory tracking performance. In the experiment, a full six-degree-of-freedom YF-16 model was used as the simulated pursuit aircraft. The Langley Visual Motion Simulator (with in-house developed wash-out), and a Langley developed g-seat were principal components of the simulation. The results of the experiment were examined utilizing univariate and multivariate techniques. The statistical analyses demonstrate that the platform motion and g-seat cues provide additional information to the pilot that allows substantial reduction of lateral tracking error. Also, the analyses show that the g-seat cue helps reduce vertical error.

Mckissick, B. T.↗

Pursuit Eye Movements

When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

Krauzlis, Rich↗

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood↗

Phase Field Dislocation Dynamics (PFDD)

Phase Field Dislocation Dynamics (PFDD) is a phase field approach for tracking the motion and interactions of individual dislocations in materials, mostly face-centered cubic (fcc) metals. The phase field approach relies on scalar order parameters or phase field variables to track a quantity of interest. In PFDD, these phase field variables represent the passage of perfect dislocations across each active slip system, with one order parameter defined in each slip system. Partial dislocations are represented with linear combinations of the order parameters. The system is evolved through minimization of the total system energy, which is directly dependent on the phase field variables. All of the physics is described by the total energy functional that is derived from a thermodynamic basis, and the system kinetics are evolved using a Ginzburg-Landau (GL) equation.

Hunter, Abigail↗

TU-E-213-03: Tools for Ensuring Quality and Safety

Purpose: To develop the first 4D robust optimization (RO) method accounting for respiratory motion and evaluate its potential to improve plan robustness and optimality compared to 3D RO and PTV-based optimization. Methods: A set of 4D CT images are used to track respiratory motion and deformation of tumors and organs. For each of 10 respiration phases, dose distributions for nine different uncertainty scenarios including the nominal one, those incorporating ±5mm setup uncertainties long x, y and z directions and ±3.5% range uncertainties are calculated. All 90 dose distributions are simultaneously optimized to achieve full dose coverage of 10 CTVs and sparing of normal structures. ITV-based 3D RO and PTV-based optimization based on the average CT are also carried for the same patient using same dose volume constrains. After optimization, 4D robustness evaluation was performed for all resulting plans. The CTV coverage and the sparing of normal tissue in 10 phases are evaluated and compared among the three methods. The widths of DVH bands represent the robustness of dose distributions in the structures. Results: For one patient studied so far, the worst case CTV coverage by the prescription dose among all 90 scenarios is: 99% for 4D RO; 88.9% for 3D RO, and 85.2% for PTV based optimization. 4D RO also results in best robustness with the narrowest DVH’ bandwidths for the CTV. 4D and 3D RO have similar organ sparing while PTV based optimization results in worst organ sparing. Conclusion: 4D robust optimization which accounts for anatomy motion and deformation in the optimization process, significantly improves plan robustness and achieves higher quality treatment plans for lung cancer patients. The method is being evaluated for multiple patients with different tumor and motion characteristics.

60 APPLIED LIFE SCIENCES↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron collection by a highly positive satellite in the ionosphere: Test aprticle simulation

Collection of electrons by a satellite at a relatively high potential in low Earth orbit, including the effects of the satellite's orbital motion, remains a poorly understood phenomenon. Using a test particle simulation in which charged particle motion is tracked in prescribed electric fields, we calculate here the current collection and the nature of the energy distribution function of the electrons collected by the satellite, including the effects of the satellite orbital motion. Calculations of the collected current without the orbital motion show an excellent agreement with the current from the Parker-Murphy model, but with the orbital motion of the satellite the current collection is enhanced, the degree of enhancement depending on the size of the satellite sheath extending along the magnetic field line. In the latter case, the flow of electrons around the satellite shows some interesting behaviors including azimuthal E x B drift around the satellite, axial trapping along the magnetic field, and formation of field-aligned flow of electrons in the wake region. The total energy of the collected electrons is approximately equal e phi(sub 0), where phi(sub 0) is the satellite potential, but the partition of the energy into components parallel (W(sub parallel)) and perpendicular (W(sub perpendicular)) to the magnetic field shows interesting features. For the magnetic field along the polar axis Z, the energy distributions near the poles are perfectly field aligned, that is, the parallel energy (W(sub parallel) = e phi(sub 0). The perpendicular component (W(sub perpendicular)) progressively increases toward the 'equator' of the spherical satellite. For a sufficiently large bias potential phi(sub 0), the equatorial energy distributions f(W(sub parallel)) and f(W(sub perpendicular)) show fine structures having multiple peaks. These features of the distribution functions result from the chaotic motion of electrons and the associated coupling between the electron motions parallel and perpendicular to the magnetic field in strongly nonuniform electric fields near the satellite.

Singh, Nagendra↗

General Equations of Motion for a Damaged Asymmetric Aircraft

There is a renewed interest in dynamic characteristics of damaged aircraft both in order to assess survivability and to develop control laws to enhance survivability. This paper presents a set of flight dynamics equations of motion for a rigid body not necessarily referenced to the body's center of mass. Such equations can be used when the body loses a portion of its mass and it is desired to track the motion of the body s previous center of mass/reference frame now that the mass center has moved to a new position. Furthermore, results for equations presented in this paper and equations in standard aircraft simulations are compared for a scenario involving a generic transport aircraft configuration subject to wing damage.

Bacon, Barton J.↗

Digital Image Correlation for Performance Monitoring

Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of non-destructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

Palaviccini, Miguel↗

Digital Image Correlation for Performance Monitoring.

Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of nondestructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video (HSV) and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

47 OTHER INSTRUMENTATION↗

TREAT Fuel Motion Summary Report. SETH A-E Experiments

In support of the Accident Tolerant Fuels program, experiment devices are being developed to enable transient testing of pressurized water reactor (PWR) type fuel specimens. In fiscal year 2019 several fueled tests were conducted in the Transient Reactor Test Facility (TREAT) using the Separate Effects Test Holder (SETH). Five different SETH capsules (SETH A-E) were assembled, each holding a 10-pellet rodlet with 4.9% enriched, commercially-produced fresh UO2 pellets in zirconium alloy cladding with pellet dimensions having typical PWR radial dimensions and a total pellet stack length measuring 10.16 cm. The rodlet’s length allows the specimen to be axially positioned in the center of the core with minimal flux variation over the height of the rodlet. The fuel motion monitoring system (FMMS) is located on the north side of the TREAT reactor. Having direct line-of-sight of the core enables the FMMS to collect spatially-resolved data for fast neutrons generated due to fission occurring in experiment specimens. The FMMS contains 360 channels that make up a 10 (horizontal) by 36 (vertical) array of viewing slots; for the SETH A-E test series 96 proton-recoil scintillator (PRS) detectors were installed in the system. The fast neutrons are detected in the PRS detectors from light produced by the recoil of protons interacting with ZnS(Ag) grains in each detector's scintillator button. This report focuses on the FMMS data captured in the SETH A-E experiments, with multiple transients varying in reactivity addition and length. The first three experiments had a total reactor energy of 101 MJ each and were critical in understanding the FMMS field of view, lead shielding, and other TREAT data acquisition systems. SETH-B2 and C had a reactivity addition of almost double the previous transients and served as a demonstration of the detector array behavior under increased reactor energy. The final two SETH experiments (D and E) were aimed at reaching cladding melting temperatures with a reactor energy over 500 MJ for each test. In preparation for the higher energy transients, the FMMS lead shielding was reduced to 0.5 inches from the 6 inches used in SETH A-C. This was expected to saturate the detectors at the peak of the transient in exchange for higher sensitivity at lower energies after the peak, when the motion was expected. SETH-D was clipped at approximately 3 seconds, which was too early for the FMMS to capture any rodlet motion. SETH-E had the same reactivity addition as SETH-D but the transient time was extended to 18 seconds. The FMMS captured the downward motion of the rodlet in SETH-E as the count rate significantly changed for the detectors viewing the specimen. Snapshots taken throughout the transient helped identify the approximate time at which the motion initiated. Further analysis of the individual detector data captured on a per-millisecond time basis resulted in a determination that the approximate time for the onset of the downward motion was 2.84 ± 0.02 seconds. Neutron radiographs confirmed that downward motion occurred for SETH-D and SETH-E. Motion in SETH-D could also have been captured by the FMMS if the transient time had been longer for SETH-D. Ultimately, these final two tests served to demonstrate the FMMS's ability to track fuel motion during transient experiments at TREAT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Version 2 - Tidal Energy Resource Characterization, Velocity and Turbulence Measurements, Cook Inlet, AK, 2021

Version 2 of MHKDR submission #475, which also contains the metadata for these measurements. Files here are stored in netCDF4 format, which can be read in Python using the "netcdf4" or "xarray" packages or in MATLAB using the "ncread()" function. Changes are as follows: MWM1 (mid-water mooring 1) ADV - Time length of data now ends when bottom track data is lost - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved velocity, turbulent kinetic energy (TKE), Reynolds stress, time interval (TI), and dissipation rate estimations MWM1 Down-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified MWM1 Up-Looking ADCP - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified - Velocity unchanged MWM2 ADV - Removes data after instrument was hit by debris - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved velocity, TKE, Reynolds stress, TI, and dissipation rate estimations MWM2 Down-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified MWM2 Up-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified THEOM (bottom lander) ADV - Improved Doppler noise subtraction - improved TKE, Reynolds stress, TI, and dissipation rate estimations - Velocity unchanged THEOM ADCP (up-looking) - Improved Doppler noise subtraction - improved TKE, TI, and dissipation rate estimations - Removed vertical TKE component (w'w' bar) - Velocity unchanged

16 TIDAL AND WAVE POWER↗

Verification of the Solar Dynamics Observatory High Gain Antenna Pointing Algorithm Using Flight Data

The Solar Dynamics Observatory (SDO) is a NASA spacecraft designed to study the Sun. It was launched on February 11, 2010 into a geosynchronous orbit, and uses a suite of attitude sensors and actuators to finely point the spacecraft at the Sun. SDO has three science instruments: the Atmospheric Imaging Assembly (AIA), the Helioseismic and Magnetic Imager (HMI), and the Extreme Ultraviolet Variability Experiment (EVE). SDO uses two High Gain Antennas (HGAs) to send science data to a dedicated ground station in White Sands, New Mexico. In order to meet the science data capture budget, the HGAs must be able to transmit data to the ground for a very large percentage of the time. Each HGA is a dual-axis antenna driven by stepper motors. Both antennas transmit data at all times, but only a single antenna is required in order to meet the transmission rate requirement. For portions of the year, one antenna or the other has an unobstructed view of the White Sands ground station. During other periods, however, the view from both antennas to the Earth is blocked for different portions of the day. During these times of blockage, the two HGAs take turns pointing to White Sands, with the other antenna pointing out to space. The HGAs handover White Sands transmission responsibilities to the unblocked antenna. There are two handover seasons per year, each lasting about 72 days, where the antennas hand off control every twelve hours. The non-tracking antenna slews back to the ground station by following a ground commanded trajectory and arrives approximately 5 minutes before the formerly tracking antenna slews away to point out into space. The SDO Attitude Control System (ACS) runs at 5 Hz, and the HGA Gimbal Control Electronics (GCE) run at 200 Hz. There are 40 opportunities for the gimbals to step each ACS cycle, with a hardware limitation of no more than one step every three GCE cycles. The ACS calculates the desired gimbal motion for tracking the ground station or for slewing, and sends the command to the GCE at 5 Hz. This command contains the number of gimbals steps for that ACS cycle, the direction of motion, the spacing of the steps, and the delay before taking the first step. The AIA and HMI instruments are sensitive to spacecraft jitter. Pre-flight analysis showed that jitter from the motion of the HGAs was a cause of concern. Three jitter mitigation techniques were developed to overcome the effects of jitter from different sources. The first method is the random step delay, which avoids gimbal steps hitting a cadence on a jitter-critical mode by pseudo-randomly delaying the first gimbal step in an ACS cycle. The second method of jitter mitigation is stagger stepping, which forbids the two antennas from taking steps during the same ACS cycle in order to avoid constructively adding jitter from two antennas. The third method is the inclusion of an instrument No Step Request (NSR), which allows the instruments to request a stoppage in gimbal stepping during the times when they are taking images. During the commissioning phase of the mission, a jitter test was performed onboard the spacecraft. Various sources of jitter, such as the reaction wheels, the High Gain Antenna motors, and the motion of the instrument filter wheels, were examined to determine the level of their effect on the instruments. During the HGA portion of the test, the jitter amplitudes from the single step of a gimbal were examined, as well as the amplitudes due to the execution of various gimbal rates. These jitter levels are compared with the gimbal jitter allocations for each instrument. Additionally, the jitter test provided insight into a readback delay that exists with the GCE. Pre-flight analysis suggested that gimbal steps scheduled to occur during the later portion of an ACS cycle would not be read during that cycle, resulting in a delay in the telemetered current gimbal position. Flight data from the jitter test confirmed this expectation. Analysis is presentehat shows the readback delay does not have a negative impact on gimbal control. The decision was made to consider implementing two of the jitter mitigation techniques on board the spacecraft: stagger stepping and the NSR. Flight data from two sets of handovers, one set without jitter mitigation and the other with mitigation enabled, were examined. The trajectory of the predicted handover was compared with the measured trajectory for the two cases, showing that tracking was not negatively impacted with the addition of the jitter mitigation techniques. Additionally, the individual gimbal steps were examined, and it was confirmed that the stagger stepping and NSRs worked as designed. An Image Quality Test was performed to determine the amount of cumulative jitter from the reaction wheels, HGAs, and instruments during various combinations of typical operations. In this paper, the flight results are examined from a test where the HGAs are following the path of a nominal handover with stagger stepping on and HMI NSRs enabled. In this case, the reaction wheels are moving at low speed and the instruments are taking pictures in their standard sequence. The flight data shows the level of jitter that the instruments see when their shutters are open. The HGA-induced jitter is well within the jitter requirement when the stagger step and NSR mitigation options are enabled. The SDO HGA pointing algorithm was designed to achieve nominal antenna pointing at the ground station, perform slews during handover season, and provide three HGA-induced jitter mitigation options without compromising pointing objectives. During the commissioning phase, flight data sets were collected to verify the HGA pointing algorithm and demonstrate its jitter mitigation capabilities.

Bourkland, Kristin L.↗

Congruent and spurious motion in the learning and performance of a compensatory tracking task.

Examination of the importance of congruent and spurious yaw motion in compensatory tracking by eight airline pilots. The pilots, seated erect in the Ames man-carrying rotation device(MCRD), tracked with k/s+1 and k/s(s+1) vehicle dynamics in fixed- and moving-base simulation. Following the learning phase of the experiment, five levels of spurious angular acceleration were superimposed on the motion of the MCRD. Learning of the tracking task was found to be a function of both vehicle dynamics and mode of simulation. The presence of congruent motion information reduced learningtime in k/s(s+1) vehicle dynamics and resulted in lower tracking error in both vehicle dynamics. The spurious angular accelerations resulted in an increase in pilot tracking error; however, the relationship between the magnitude of the acceleration and its effect was highly complex. The data suggest that the minimal disturbance level for spurious angular accelerations during tracking is below 0.4 degec.

Guercio, J. G.↗