Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Characteristics of Un doped and Europium-dopedSrI2 Scintillator Detectors

High energy resolution gamma-ray detectors that can be formed into relatively large sizes while operating at room temperature offer many advantages for national security applications. We are working toward that goal through the development of SrI{sub 2}(Eu) scintillator detectors, which routinely provide <;3.0% energy resolution at 662 keV with volumes >;10 cm{sup 3}. In this study, we have tested pure, undoped SrI{sub 2} to gain a better understanding of the scintillation properties and spectroscopic performance achievable without activation. An undoped crystal grown from 99.999% pure SrI{sub 2} pellets was tested for its spectroscopic performance, its light yield, and uniformity of scintillation light collection as a function of gamma-ray interaction position relative to the crystal growth direction. Undoped SrI{sub 2} was found to provide energy resolution of 5.3% at 662 keV, and the light collection nonuniformity varied by only 0.72% over the length of the crystal. Measurements of both a 3% Eu-doped and the undoped SrI{sub 2} crystal were carried out in the SLYNCI facility and indicate differences in their light yield non-proportionality. The surprisingly good scintillation properties of the pure SrI{sub 2} crystal suggests that with high-purity feedstock, further reduction of the Eu concentration can be made to grow larger crystals while not adversely impacting the spectroscopic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic System for Precision Assembly of NIF Ignition Targets

This paper provides an overview of the design and testing of a robotic system developed for assembling the inertial confinement fusion ignition targets (depicted in Figures 1 and 2) that will be fielded on the National Ignition Facility (NIF) laser [1]. The system, referred to as the Final Assembly Machine and shown in Figure 3, consists of six groups of stacked axes that allow manipulating millimeter-sized components with submicron precision, integrated with an optical coordinate measuring machine (OCMM) that provides in-situ metrology. Nineteen motorized axes and ten manual axes are used to control the position and orientation of five objects that are predominantly assembled together in a cubic centimeter work zone. An operator-in-the-loop provides top-level control of the system, making it more similar to a surgical robot than to a programmed computer-controlled machine tool. The operator is provided visual feedback by the vision system of the OCMM, and tactile feedback by force and torque sensors embedded in the tooling that holds the major components being assembled. The vision system is augmented with auxiliary mirrors providing multiple viewing directions, and is used to guide the approach and alignment of the components, and to measure the relative position and orientation of the components. The force and torque sensors are used to guide the final approach, alignment, and mating of the components that are designed to slip-fit together, and to monitor that mating while adhesively bonding those components and attaching the target base.

42 ENGINEERING↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alignment effects on a neutron imaging system using coded apertures

A high resolution neutron imaging system is being developed and tested on the OMEGA laser facility for inertial confinement fusion experiments. This diagnostic uses a coded imaging technique with a penumbral or an annular aperture. The sensitiveness of these techniques to misalignment was pointed out with both experiments and simulations. Results obtained during OMEGA shots are in good agreement with calculations performed with the Monte Carlo code GEANT4. Both techniques are sensitive to the relative position of the source in the field of view. The penumbral imaging technique then demonstrates to be less sensitive to misalignment compared to the ring. These results show the necessity to develop a neutron imaging diagnostic for megajoule class lasers taking into account our alignment capabilities on such facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Belowground plant allocation regulates rice methane emissions from degraded peat soils

Carbon-rich peat soils have been drained and used extensively for agriculture throughout human history, leading to significant losses of their soil carbon. One solution for rewetting degraded peat is wet crop cultivation. Crops such as rice, which can grow in water-saturated conditions, could enable agricultural production to be maintained whilst reducing CO 2 and N 2 O emissions from peat. However, wet rice cultivation can release considerable methane (CH 4 ). Water table and soil management strategies may enhance rice yield and minimize CH 4 emissions, but they also influence plant biomass allocation strategies. It remains unclear how water and soil management influences rice allocation strategies and how changing plant allocation and associated traits, particularly belowground, influence CH 4 -related processes. We examined belowground biomass (BGB), aboveground biomass (AGB), belowground:aboveground ratio (BGB:ABG), and a range of root traits (root length, root diameter, root volume, root area, and specific root length) under different soil and water treatments; and evaluated plant trait linkages to CH 4 . Rice (Oryza sativa L.) was grown for six months in field mesocosms under high (saturated) or low water table treatments, and in either degraded peat soil or degraded peat covered with mineral soil. We found that BGB and BGB:AGB were lowest in water saturated conditions where mineral soil had been added to the peat, and highest in low-water table peat soils. Furthermore, CH 4 and BGB were positively related, with BGB explaining 60% of the variation in CH 4 but only under low water table conditions. Our results suggest that a mix of low water table and mineral soil addition could minimize belowground plant allocation in rice, which could further lower CH 4 likely because root-derived carbon is a key substrate for methanogenesis. Minimizing root allocation, in conjunction with water and soil management, could be explored as a strategy for lowering CH 4 emissions from wet rice cultivation in degraded peatlands.

54 ENVIRONMENTAL SCIENCES↗

Environmental Factors Related to the Distribution, Abundance, and Life History Characteristics of Mountain Whitefish in Idaho

Abstract Mountain whitefish Prosopium williamsoni are a broadly distributed native salmonid in western North America, but comparatively little investigation has been made regarding their population characteristics. We surveyed 2,043 study sites to assess whether physiochemical stream conditions affected mountain whitefish distribution and abundance in southern Idaho, and at 20 of these sites life history characteristics were also estimated. A total of 581 sites were dry or contained too little water to support any fish species. Mountain whitefish were captured at 106 sites; for these sites only, mean abundance was 2.2/100 m2. They were rarely present when mean wetted width was less than 10 m but were almost always present when wetted width was greater than 15 m. We estimated that within the study area there were approximately 4.7 ± 1.8 million mountain whitefish, mostly in fifth- to seventh-order streams, which comprised only 13% of the total stream kilometers but accounted for 93% of the total abundance of whitefish. Growth was positively related to mean annual water temperature and negatively related to site elevation. Mountain whitefish were long lived, most (90%) populations containing fish estimated to be at least 10 years old. This longevity produced total annual survival rates averaging 0.82 (range = 0.63–0.91). In general, the growth, fecundity, and survival of mountain whitefish were higher in the upper Snake River basin than in other areas for which data have been reported. Whitefish matured at about 250 mm and about age 2, with little variation in length and age at maturity between sites; males matured at a smaller size and younger age than females. The disproportionate use of larger (i.e., >15-m-wide) streams by mountain whitefish in southern Idaho differs from the situation in more northerly locations, where they apparently are more common in smaller streams.

Meyer, Kevin A.↗

Liquid Microjunction Surface Sampling Probe Fluid Dynamics: Computational and Experimental Analysis of Coaxial Intercapillary Positioning Effects on Sample Manipulation

A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means for visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formationmode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for ultrafast optical deflection enabling optical recording via serrated or graded light illumination

In one general embodiment, a method for deflecting an optical signal input into a waveguide is provided. In operation, an optical input signal is propagated through a waveguide. Additionally, an optical control signal is applied to a mask positioned relative to the waveguide such that the application of the optical control signal to the mask is used to influence the optical input signal propagating in the waveguide. Furthermore, the deflected optical input signal output from the waveguide is detected in parallel on an array of detectors. In another general embodiment, a beam deflecting structure is provided for deflecting an optical signal input into a waveguide, the structure comprising at least one wave guiding layer for guiding an optical input signal and at least one masking layer including a pattern configured to influence characteristics of a material of the guiding layer when an optical control signal is passed through the masking layer in a direction of the guiding layer. In another general embodiment, a system is provided including a waveguide, an attenuating mask positioned on the waveguide, and an optical control source positioned to propagate pulsed laser light towards the attenuating mask and the waveguide such that a pattern of the attenuating mask is applied to the waveguide and material properties of at least a portion of the waveguide are influenced.

47 OTHER INSTRUMENTATION↗

Functional variability in specific root respiration translates to autotrophic differences in soil respiration in a temperate deciduous forest

CO 2 release from forest soils (R s ) is a prominent flux in the global carbon cycle. Rs is derived from roots (autotrophic respiration, R a ) and microbial (heterotrophic) respiration and is highly dynamic, as it depends on edaphic and environmental conditions as well as root functional traits and microbial community composition. It is unclear how root functional traits affect root and microbial respiration rates; however, their consideration may help parse out the relative contributions of root and microbial respiration to R s . At a temperate forest site, root systems of 3–4 functional root orders and their surrounding surface soil were carefully excavated and placed into custom trays designed to repeatedly measure R s in situ on eight temperate tree species that varied in their root functional strategies and mycorrhizal affinity. R s was measured bi-weekly to monthly for nearly one year using a custom chamber attached to a gas exchange system. R s varied over time, ranging from 0.3 to 12 µmol m -2 s -1 . Comparable root systems of the same species were excised from the soil and specific root respiration rates (R r ) were measured. Rr ranged from 2.5 to 9.0 nmol g -1 s -1 and was negatively correlated with root tissue density and positively related to root tissue nitrogen concentration. Using R r to estimate R a , we estimate that R a accounts for <10%, on average 2–3%, of R s for individual root systems (averaging 1.2 g dry biomass) housed in surrounding soil (average 1.3 kg dry mass) in situ; thus, Ra was roughly 20 times greater than Rh per unit mass. The contribution of R a peaked in the fall and coincided with leaf senescence of the forest canopy. A soil-sterilizing experimental treatment designed to help isolate R a in situ reduced bacterial biomass and shifted fungal community composition, but there was no reduction in Rs of the in-situ root-soil tray systems. The relative R a to R s ratio increased with root functional strategies characterized by greater specific root length and tip abundance, but also to greater root tissue density. The ratio of R a to R s also increased with warmer soil temperatures and decreased slightly with increasing soil moisture. We discuss how incorporating root functional traits as modulators of the autotrophic contribution to R s could be considered when modeling total soil CO 2 efflux from forests.

54 ENVIRONMENTAL SCIENCES↗

Lower functional redundancy in “narrow” than “broad” functions in global soil metagenomics

Understanding the relationship between soil microbial taxonomic compositions and functional profiles is essential for predicting ecosystem functions under various environmental disturbances. However, even though microbial communities are sensitive to disturbance, ecosystem functions remain relatively stable, as soil microbes are likely to be functionally redundant. Microbial functional redundancy may be more associated with “broad” functions carried out by a wide range of microbes than with “narrow” functions in which specific microorganisms specialize. Thus, a comprehensive study to evaluate how microbial taxonomic compositions correlate with broad and narrow functional profiles is necessary. Here, we evaluated soil metagenomes worldwide to assess whether functional and taxonomic diversities differ significantly between the five broad and the five narrow functions that we chose. Our results revealed that, compared with the five broad functions, soil microbes capable of performing the five narrow functions were more taxonomically diverse, and thus their functional diversity was more dependent on taxonomic diversity, implying lower levels of functional redundancy in narrow functions. Co-occurrence networks indicated that microorganisms conducting broad functions were positively related, but microbes specializing in narrow functions were interacting mostly negatively. Our study provides strong evidence to support our hypothesis that functional redundancy is significantly different between broad and narrow functions in soil microbes, as the association of functional diversity with taxonomy was greater in the five narrow than in the five broad functions.

54 ENVIRONMENTAL SCIENCES↗

Centrifugal Casting Features/Metallurgical Characterization of Aluminum Alloys

This paper deals with the study of centrifugal effects on aluminium castings under high G values. Most of the studies in this domain (FGMs obtained by centrifugal casting) deal with functionally graded composites reinforced with a solid phase such as silicon particles or others. However, in this study it will be shown that unreinforced aluminium alloys may be significantly influenced by the centrifugal effect and that functionally graded castings are also obtained. It has been observed that the centrifugal effect may increase in some alloys, depending on the relative position in the castings, the rupture strength by approx. 50%, and rupture strain by about 300%, as compared to the gravity casting technique. The Young's modulus may also increase by about 20%. It has also been reported that in vertical centrifugal castings there are mainly three aspects that affect the components thus obtained, namely: fluid dynamics; vibration (inherent to the system); and centrifugal force. These features have a different effect on the castings depending on the aluminium alloy. In this paper, an analysis of the most important effects of the centrifugal casting process on metallurgical features is conducted. A solidification characterization at several points along the mould will be made in order to have an accurate idea of both the fluid dynamics inside the mould during the casting and the solidification behavior in different parts of the component. These two analyses will be related to the metallurgical properties (phase distribution; SDAS; eutectic silicon content and shape, pores density and shape) along the component and mainly along the direction of the centrifugal pressure. A comparison between castings obtained by both centrifugal casting technique and gravity casting technique is made for reference (gravity casting)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Composition and Configuration Dependence of Glass-Transition Temperature in Binary Copolymers and Blends of Polyhydroxyalkanoate Biopolymers

Polyhydroxyalkanoates (PHAs), a promising class of biomaterials, have gained considerable attention to replace petroleum-based plastics owing to their excellent biocompatibility and biodegradability. Homopolymers of PHA suffer from poor tunability in thermal and mechanical properties. Going from homopolymers to copolymers, the design space can be substantially enhanced by combining two or more monomers in different compositions (i.e., relative ratios of the different monomers) and configurations (i.e., relative positions of the different monomers in the polymer backbone) leading to a substantially large chemical space where application-specific optimization for the targeted functionality can be performed. However, this composition and configuration dependence of properties in the vast PHA copolymer chemical space remains largely unexplored. In this contribution, further building on our past work with PHA homopolymers, we systematically explore these chemical trends for glass-transition temperature (Tg) in PHA copolymers and blends. Overall, our molecular dynamics simulations, utilizing a previously validated force field for PHAs, suggest that these trends are largely governed not only by the homopolymer Tg values but also configuration-dependent interchain interactions in the copolymer system. In particular, our results indicate that the configuration-dependent variation in the target property at a fixed composition can be significant in the presence of hydrogen-bond-forming monomers. These qualitative observations are further rationalized by quantitatively analyzing various closely related atomic level descriptors of copolymers and blends such as monomer mobility, number of hydrogen bonds, and pair correlation functions. The findings presented in this work help to develop a deeper atomistic-level understanding of thermomechanical behavior of PHA-based copolymers and can potentially guide the rational design of biopolymers as environmental-friendly functional materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient location. When tumor SNR is held constant (i.e., x-ray fluence is scaled appropriately), SBDX gives 2–10 times less dose than fluoroscopy for the same conditions within the typical range of patient locations. The relative position of the patient (as a percent of SDD) has a much more significant impact on dose than either SDD or patient position. The patient position providing the minimum dose for a given tumor SNR and SDD is approximately the same as the position of maximum tomographic angle.Conclusions: SBDX offers a significant dose advantage over currently used C-arm fluoroscopy. The patient location with lowest dose coincides with the location of maximum tomographic angle. In order to provide adequate space for the patient and for the pulmonologists’ equipment, a SDD of 100 cm is recommended.

61 RADIATION PROTECTION AND DOSIMETRY↗

Understanding aerosol–cloud interactions using a single-column model for a cold-air outbreak case during the ACTIVATE campaign

Marine boundary layer clouds play a critical role in Earth's energy balance. Their microphysical and radiative properties are highly impacted by ambient aerosols and dynamic forcings. In this study, we evaluate the representation of these clouds and related aerosol–cloud interaction processes in the single-column version of the E3SM climate model (SCM) against field measurements collected during the NASA ACTIVATE campaign over the western North Atlantic, as well as intercompare results with high-resolution process level models. We show that E3SM SCM reproduces the macrophysical properties of post-frontal boundary layer clouds in a cold-air outbreak (CAO) case well. However, it generates fewer but larger cloud droplets compared to aircraft measurements. Further sensitivity tests show that the underestimation of both aerosol number concentration and vertical velocity variance contributes to this bias. Aerosol–cloud interactions are examined by perturbing prescribed aerosol properties in E3SM SCM with fixed dynamics. Higher aerosol number concentration or hygroscopicity leads to more numerous but smaller cloud droplets, resulting in a stronger cooling via shortwave cloud forcing. This apparent Twomey effect is consistent with prior climate model studies. The cloud liquid water path shows a weakly positive relation with cloud droplet number concentration due to precipitation suppression. This weak aerosol effect on cloud macrophysics may be attributed to the dominant impact of strong dynamical forcing associated with the CAO. Our findings indicate that the SCM framework is a key tool to bridge the gap between climate models, process level models, and field observations to facilitate process level understanding.

54 ENVIRONMENTAL SCIENCES↗

A Proper Motions Study of the Globular Cluster NGC 3201

With a high value of heliocentric radial velocity, a retrograde orbit, and suspected to have an extragalactic origin, NGC 3201 is an interesting globular cluster for kinematical studies. Our purpose is to calculate the relative proper motions (PMs) and membership probability for the stars in the wide region of globular cluster NGC 3201. PM based membership probabilities are used to isolate the cluster sample from the field stars. The membership catalog will help address the question of chemical inhomogeneity in the cluster. Archive CCD data taken with a wide-field imager (WFI) mounted on the ESO 2.2 m telescope are reduced using the high-precision astrometric software developed by Anderson et al. for the WFI images. The epoch gap between the two observational runs is ∼14.3 years. To standardize the BVI photometry, Stetson’s secondary standard stars are used. The CCD data with an epoch gap of ∼14.3 years enables us to decontaminate the cluster stars from field stars efficiently. The median precision of PMs is better than ∼0.8 mas yr{sup −1} for stars having V<18 mag that increases up to ∼1.5 mas yr{sup −1} for stars with 18<V<20 mag. Kinematic membership probabilities are calculated using PMs for stars brighter than V∼20 mag. An electronic catalog of positions, relative PMs, BVI magnitudes, and membership probabilities in the ∼19.7 × 17 arcmin{sup 2} region of NGC 3201 is presented. We use our membership catalog to identify probable cluster members among the known variables and X-ray sources in the direction of NGC 3201.

79 ASTRONOMY AND ASTROPHYSICS↗

Using neutral beams as a light ion beam probe (invited)

By arranging the particle first banana orbits to pass near a distant detector, the light ion beam probe (LIBP) utilizes orbital deflection to probe internal fields and field fluctuations. The LIBP technique takes advantage of (1) the in situ, known source of fast ions created by beam-injected neutral particles that naturally ionize near the plasma edge and (2) various commonly available diagnostics as its detector. These born trapped particles can traverse the plasma core on their inner banana leg before returning to the plasma edge. Orbital displacements (the forces on fast ions) caused by internal instabilities or edge perturbing fields appear as modulated signal at an edge detector. Adjustments in the q-profile and plasma shape that determine the first orbit, as well as the relative position of the source and detector, enable studies under a wide variety of plasma conditions. This diagnostic technique can be used to probe the impact on fast ions of various instabilities, e.g., Alfvén eigenmodes (AEs) and neoclassical tearing modes, and of externally imposed 3D fields, e.g., magnetic perturbations. To date, displacements by AEs and by externally applied resonant magnetic perturbation fields have been measured using a fast ion loss detector. Comparisons with simulations are shown. In addition, nonlinear interactions between fast ions and independent AE waves are revealed by this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Compact ultrahigh vacuum sample environments for x-ray nanobeam diffraction and imaging

X-ray nanobeams present the opportunity to obtain structural insight in materials with small volumes or nanoscale heterogeneity. The effective spatial resolution of the information derived from nanobeam techniques depends on the stability and precision with which the relative position of the x-ray optics and sample can be controlled. Nanobeam techniques include diffraction, imaging, and coherent scattering, with applications throughout materials science and condensed matter physics. Sample positioning is a significant mechanical challenge for x-ray instrumentation providing vacuum or controlled gas environments at elevated temperatures. Such environments often have masses that are too large for nanopositioners capable of the required positional accuracy of the order of a small fraction of the x-ray spot size. Similarly, the need to place x-ray optics as close as 1 cm to the sample places a constraint on the overall size of the sample environment. We illustrate a solution to the mechanical challenge in which compact ion-pumped ultrahigh vacuum chambers with masses of 1–2 kg are integrated with nanopositioners. The overall size of the environment is sufficiently small to allow their use with zone-plate focusing optics. We describe the design of sample environments for elevated-temperature nanobeam diffraction experiments demonstrate in situ diffraction, reflectivity, and scanning nanobeam imaging of the ripening of Au crystallites on Si substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗