Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CaloScore v2: single-shot calorimeter shower simulation with diffusion models

Diffusion generative models are promising alternatives for fast surrogate models, producing high-fidelity physics simulations. However, the generation time often requires an expensive denoising process with hundreds of function evaluations, restricting the current applicability of these models in a realistic setting. In this work, we report updates on the CaloScorearchitecture, detailing the changes in the diffusion process, which produces higher quality samples, and the use of progressive distillation, resulting in a diffusion model capable of generating new samples with a single function evaluation. Here we demonstrate these improvements using the Calorimeter Simulation Challenge 2022 dataset.

47 OTHER INSTRUMENTATION↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/𝑐 2 –TeV/𝑐 2 weakly interacting massive particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/𝑐 2 dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Measurement of neutral current single π 0 production on argon with the MicroBooNE detector

We report the first measurement of π 0 production in neutral current (NC) interactions on argon with average neutrino energy of ≲1 GeV. We use data from the MicroBooNE detector’s 85-tonne active volume liquid argon time projection chamber situated in Fermilab’s Booster Neutrino Beam and exposed to 5.89 &#x00D7; 10 20 protons on target for this measurement. Measurements of NC π 0 events are reported for two exclusive event topologies without charged pions. Those include a topology with two photons from the decay of the π 0 and one proton and a topology with two photons and zero protons. Flux-averaged cross-sections for each exclusive topology and for their semi-inclusive combination are extracted (efficiency-correcting for two-plus proton final states), and the results are compared to predictions from the GENIE, NEUT, and NUWRO neutrino event generators. We measure cross sections of 1.243 ± 0.185 (syst) ±0.076 (stat), 0.444 ± 0.098 ± 0.047, and 0.624 ± 0.131 ± 0.075 [10 -38 cm 2 /Ar] for the semi-inclusive NCπ 0 , exclusive NCπ 0 +1p, and exclusive NCπ 0 +0p processes, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QuGrav: Bringing gravitational waves to light with qumodes

We propose using qumodes, quantum bosonic modes, for detecting high-frequency gravitational waves via the inverse Gertsenshtein effect, where a gravitational wave resonantly converts into a single photon in a magnetized cavity. For an occupation number n of the photon field in a qumode, the conversion probability is enhanced by a factor of n + 1 due to Bose-Einstein statistics. Unlocking this increased sensitivity entails the ability to continuously prepare the qumode and perform nondemolition measurement on the qumode-qubit system within the qumode coherence time. Our results indicate that, at microwave frequencies and with existing technology, the proposed setup can attain sensitivities within 1.7 orders of magnitude of the cosmological bound. With anticipated near-future improvements, it has the potential to surpass this limit and pave the way for the first exploration of high-frequency cosmological gravitational wave backgrounds. At optical frequencies, it can enhance the sensitivity of current detectors by one order of magnitude. That further enhances their potential in reaching the single-graviton level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting for light dark matter with DUNE PRISM

We present the prospects for exploring low-scale dark sectors with the future DUNE experiment and the impact of the movable off-axis near detector concept, DUNE-PRISM, and a higher energy beam configuration. We focus on a simple scenario which extends the Standard Model by a “dark” U(1), comprising scalar or fermion dark matter and a dark photon kinetically mixed with the photon. We consider nucleus and electron scattering signatures of dark matter produced in the beam via neutral pseudoscalar meson decays. Our results show that, by analysing the energy spectra of single electron events in multiple off-axis angle, DUNE-PRISM can substantially increase the experimental sensitivity to these models, reaching theoretical targets for thermal relic dark matter for a wide range of dark photon and dark matter masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PASSAT: particle accelerator helioScopes for Slim Axion-like-particle deTection

We propose a novel method to search for axion-like particles (ALPs) at particle accelerator experiments. ALPs produced at the target via the Primakoff effect subsequently enter a region with a magnetic field, where they are converted to photons that are then detected. Dubbed Particle Accelerator helioScopes for Slim Axion-like-particle deTection (PASSAT), our proposal uses the principle of the axion helioscope but replaces ALPs produced in the Sun with those produced in a target material. Since we rely on ALP-photon conversions , our proposal probes light (slim) ALPs that are otherwise inaccessible to laboratory-based experiments which rely on ALP decay, and complements astrophysical probes that are more model-dependent. As a first application, we reinterpret existing data from the NOMAD experiment in light of PASSAT, and constrain the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 10^{-4}~\mathrm{GeV}^{-1}$$ ~ 10 - 4 GeV - 1 . As benchmarks of feasible low-cost experiments improving over the NOMAD limits, we study the possibility of re-using the magnets of the CAST and the proposed BabyIAXO experiments and placing them at the proposed BDF facility at CERN, together with some new detectors. We find that these realizations of PASSAT allow for a direct probe of the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 4\times 10^{-6}~\mathrm{GeV}^{-1}$$ ~ 4 × 10 - 6 GeV - 1 , which are regions that have not been probed yet by experiments with laboratory-produced ALPs. In contrast to other proposals aiming at detecting single or two-photon only events in hadronic beam dump environments, that rely heavily on Monte Carlo simulations, the background in our proposal can be directly measured in-situ , its suppression optimized, and the irreducible background statistically subtracted. Sensitivity evaluations with other beams will be the subject of a future paper. The measurements suggested in this paper represent an additional physics case for the BDF at CERN beyond those already proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Characterization of skipper CCDs for cosmological applications

We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise &sigma; 0.18 e - rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗