Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Event Effect (SEE) testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

230 records · Page 13

Under-Constrained SEE Data: Implications for Estimating and Bounding SEE Rates

Increasingly scarce SEE testing resources and rapid growth of the New Space sector have increased the prevalence of under-constrained SEE data. We develop Monte Carlo tools to assess implications for SEE rate estimation. We also show that Bayesian Priors based on large datasets of SEL susceptible parts can augment under-constrained data and improve bounds on SEL rates. The resulting Bayesian Priors are also useful for bounding system SEL risk.

Single-event effect↗

Radiation Tests of Highly Scaled, High-Density, Commercial, Nonvolatile NAND Flash Memories - Update 2012

The space radiation environment poses a certain risk to all electronic components on Earth-orbiting and planetary mission spacecraft. In recent years, there has been increased interest in the use of high-density, commercial, nonvolatile flash memories in space because of ever-increasing data volumes and strict power requirements. They are used in a wide variety of spacecraft subsystems. At one end of the spectrum, flash memories are used to store small amounts of mission-critical data such as boot code or configuration files and, at the other end, they are used to construct multi-gigabyte data recorders that record mission science data. This report examines single-event effect (SEE) and total ionizing dose (TID) response in single-level cell (SLC) 32-Gb, multi-level cell (MLC) 64-Gb, and Triple-level (TLC) 64-Gb NAND flash memories manufactured by Micron Technology with feature size of 25 nm.

Irom, Farokh↗

Radiation tests of highly scaled, high-density, commercial, nonvolatile NAND flash memories— update 2012

The space radiation environment poses a certain risk to all electronic components on Earth-orbiting and planetary mission spacecraft. In recent years, there has been increased interest in the use of high-density, commercial, nonvolatile flash memories in space because of ever-increasing data volumes and strict power requirements. They are used in a wide variety of spacecraft subsystems. At one end of the spectrum, flash memories are used to store small amounts of mission-critical data such as boot code or configuration files and, at the other end, they are used to construct multi-gigabyte data recorders that record mission science data. This report examines single-event effect (SEE) and total ionizing dose (TID) response in single-level cell (SLC) 32-Gb, multi-level cell (MLC) 64-Gb, and Triple-level (TLC) 64-Gb NAND flash memories manufactured by Micron Technology with feature size of 25 nm.

Allen, Gregory R.↗

Silicon Power MOSFETs

Recent work for the NASA Electronic Parts and Packaging Program Power MOSFET task is presented. The Task technology focus, roadmap, and partners are given. Recent single-event effect test results on commercial, automotive, and radiation hardened trench power MOSFETs are summarized with an emphasis on risk of using commercial and automotive trench-gate power MOSFETs in space applications.

trench-gate MOSFET↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

Taking SiC Power Devices to the Final Frontier: Addressing Challenges of the Space Radiation Environment

Silicon carbide power device technology has the potential to enable a new generation of aerospace power systems that demand high efficiency, rapid switching, and reduced mass and volume in order to expand space-based capabilities. For this potential to be realized, SiC devices must be capable of withstanding the harsh space radiation environment. Commercial SiC components exhibit high tolerance to total ionizing dose but to date, have not performed well under exposure to heavy ion radiation representative of the on-orbit galactic cosmic rays. Insertion of SiC power device technology into space applications to achieve breakthrough performance gains will require intentional development of components hardened to the effects of these highly-energetic heavy ions. This work presents heavy-ion test data obtained by the authors over the past several years for discrete SiC power MOSFETs, JFETs, and diodes in order to increase the body of knowledge and understanding that will facilitate hardening of this technology to space radiation effects. Specifically, heavy-ion irradiation data taken under different bias, temperature, and ion beam conditions is presented for devices from different manufacturers, and the emerging patterns discussed.

Power semiconductor devices↗

Evaluation of the Radiation Susceptibility of a 3D NAND Flash Memory

We evaluated the heavy ion and proton-induced single-event effects (SEE) for a 3D NAND flash. The 3D NAND showed similar single-event upset (SEU) sensitivity to a planar NAND of similar density and performance in the multiple-cell level (MLC) storage mode. However, the single-level-cell (SLC) storage mode of the 3D NAND showed significantly reduced SEU susceptibility. Additionally, the 3D NAND showed less MBU susceptibility than the planar NAND, with reduced number of upset bits per byte and reduced cross sections overall. However, the 3D architecture exhibited angular sensitivities for both base and face angles, reflecting the anisotropic nature of the SEU vulnerability in space. Furthermore, the SEU cross section decreased with increasing fluence for both the 3D NAND and the latest generation planar NAND, indicating a variable upset rate for a space mission. These unique characteristics introduce complexity to traditional ground irradiation test procedures.

single-event upset (SEU)↗

Tradeoffs in Flight Design Upset Mitigation in State of the Art FPGAs: Hardened by Design vs. Design Level Hardening

This presentation compares and contrasts the effectiveness and the system/designer impacts of the two main approaches to upset hardening: the Actel approach (RTSX-S and RTAX-S) of low-level (inside each flip-flop) triplication and the Xilinx approach (Virtex and Virtex2) of design-level triplication of both functional blocks and voters. The effectiveness of these approaches is compared using measurements made in conjunction with each of the FPGAs' manufacturer: for Actel, published data [1] and for Xilinx, recent results from the Xilinx SEE Test Consortium (note that the author is an active and founding member). The impacts involve Actel advantages in the areas of transistor-utilization efficiency and minimizing designer involvement in the triplication while the Xilinx advantages relate to the ability to custom tailor upset hardness and the flexibility of re-configurability. Additionally, there are currently clear Xilinx advantages in available features such as the number of I/O's, logic cells, and RAM blocks as well as speed. However, the advantage of the Actel anti-fuses for configuration over the Xilinx SRAM cells is that the latter need additional functionality and external circuitry (PROMs and, at least a watchdog timer) for configuration and configuration scrubbing. Further, although effectively mitigated if done correctly, the proton upset-ability of the Xilinx FPGAs is a concern in severe proton-rich environments. Ultimately, both manufacturers' upset hardening is limited by SEFI (single-event functional interrupt) rates where it appears the Actel results are better although the Xilinx Virtex2-family result of about one SEFI in 65 device-years in solar-min GCR (the more intense part of the galactic cosmic-ray background) should be acceptable to most missions

radiation effects↗

Submicrosecond Power-Switching Test Circuit

A circuit that changes an electrical load in a switching time shorter than 0.3 microsecond has been devised. This circuit can be used in testing the regulation characteristics of power-supply circuits . especially switching power-converter circuits that are supposed to be able to provide acceptably high degrees of regulation in response to rapid load transients. The combination of this power-switching circuit and a known passive constant load could be an attractive alternative to a typical commercially available load-bank circuit that can be made to operate in nominal constant-voltage, constant-current, and constant-resistance modes. The switching provided by a typical commercial load-bank circuit in the constant-resistance mode is not fast enough for testing of regulation in response to load transients. Moreover, some test engineers do not trust the test results obtained when using commercial load-bank circuits because the dynamic responses of those circuits are, variously, partly unknown and/or excessively complex. In contrast, the combination of this circuit and a passive constant load offers both rapid switching and known (or at least better known) load dynamics. The power-switching circuit (see figure) includes a signal-input section, a wide-hysteresis Schmitt trigger that prevents false triggering in the event of switch-contact bounce, a dual-bipolar-transistor power stage that drives the gate of a metal oxide semiconductor field-effect transistor (MOSFET), and the MOSFET, which is the output device that performs the switching of the load. The MOSFET in the specific version of the circuit shown in the figure is rated to stand off a potential of 100 V in the "off" state and to pass a current of 20 A in the "on" state. The switching time of this circuit (the characteristic time of rise or fall of the potential at the drain of the MOSFET) is .300 ns. The circuit can accept any of three control inputs . which one depending on the test that one seeks to perform: a repetitive waveform from a signal generator, momentary closure of a push-button switch, or closure or opening of a manually operated on/off switch. In the case of a signal generator, one can adjust the frequency and duty cycle as needed to obtain the desired AC power-supply response, which one could display on an oscilloscope. Momentary switch closure could be useful for obtaining (and, if desired, displaying on an oscilloscope set to trigger on an event) the response of a power supply to a single load transient. The on/off switch can be used to switch between load states in which static-load regulation measurements are performed.

Folk, Eric N.↗

The INSTEP Monitoring Network: Merging High-and-Low Cost Measurements to Characterize California Wildfires

Despite challenges with data quality and scope, low-cost sensor networks have skyrocketed in popularity over the last 15 years, making air quality data available on refined spatial scales. More recently, studies have leveraged both high and low-quality instruments to create stronger “hybrid” models, with most studies focusing on particulate matter. Low-cost measurements typically represent ground-level emissions only, providing context for human health issues from climate change-driven events such as wildfires. Since low-cost sensors’ capabilities are localized, daily events and microclimates tend to dominate the data rather than larger regional or atmospheric trends. Likewise, their low cost explains their high uncertainty. In contrast, some regulatory-grade instruments produce column measurements as well, providing reliable information on a broader scope. To bridge this gap while expanding into gas-phase measurements, we deployed 12 air quality sensor packages in California, USA during the 2022 wildfire season. These INSTEP (Inexpensive Network Sensor Technology Exploring Pollution) monitors measure carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), and several hydrocarbons including methane (CH4) and formaldehyde (HCHO). Half of the monitors were co-located with remote sensing spectrometers: NASA Pandora and Total Column Carbon Observing Network (TCCON). The overlap in pollutants includes NO2, O3, and HCHO between the INSTEP monitors and the Pandora column measurements. TCCON covers column CO, CO2, and CH4, rounding out our comparison. Most of the monitors were distributed throughout the San Francisco Bay area, and an additional three were located within 100 km of Los Angeles. The sites ranged in geographic and population characteristics, including desert, mountainous, coastal, and urban locations. Since varying environmental conditions such as temperature and pressure are known to challenge sensor performance, we will apply newer sensor “calibration” techniques meant to combat this. We will normalize our sensor signals by z-scoring them prior to applying a single calibration model in the form of multivariate linear regression or an artificial neural network. While this technique has been validated for the hydrocarbon and ozone sensor types (metal oxide), it has not yet been tested on electrochemical and non-dispersive infrared sensors, which are also used in the INSTEP monitors. This will serve as a test to see if this normalization technique – or another – is most effective in accounting for environmental differences among sensors. Related data analysis efforts have found success with a variety of geospatial analysis techniques, including weighted network models in which high-quality instruments are given higher weights than their low-cost counterparts. Our preliminary analysis will focus on kriging, which uses a Gaussian algorithm to assign weights, providing estimated pollution levels at locations between monitors. Smoke trajectory and evolution will also be considered using both measurement types. We also aim to baseline subtract our emission estimates from each region to determine which portion of emissions are regional and local, further characterizing burn differences in northern and southern California fires. Future directions include using INSTEP jointly with TEMPO satellite data, and mobile deployments on aircraft and uncrewed aerial vehicles (UAV).

Low-cost sensors↗

CREME96 and Related Error Rate Prediction Methods

Predicting the rate of occurrence of single event effects (SEEs) in space requires knowledge of the radiation environment and the response of electronic devices to that environment. Several analytical models have been developed over the past 36 years to predict SEE rates. The first error rate calculations were performed by Binder, Smith and Holman. Bradford and Pickel and Blandford, in their CRIER (Cosmic-Ray-Induced-Error-Rate) analysis code introduced the basic Rectangular ParallelePiped (RPP) method for error rate calculations. For the radiation environment at the part, both made use of the Cosmic Ray LET (Linear Energy Transfer) spectra calculated by Heinrich for various absorber Depths. A more detailed model for the space radiation environment within spacecraft was developed by Adams and co-workers. This model, together with a reformulation of the RPP method published by Pickel and Blandford, was used to create the CR ME (Cosmic Ray Effects on Micro-Electronics) code. About the same time Shapiro wrote the CRUP (Cosmic Ray Upset Program) based on the RPP method published by Bradford. It was the first code to specifically take into account charge collection from outside the depletion region due to deformation of the electric field caused by the incident cosmic ray. Other early rate prediction methods and codes include the Single Event Figure of Merit, NOVICE, the Space Radiation code and the effective flux method of Binder which is the basis of the SEFA (Scott Effective Flux Approximation) model. By the early 1990s it was becoming clear that CREME and the other early models needed Revision. This revision, CREME96, was completed and released as a WWW-based tool, one of the first of its kind. The revisions in CREME96 included improved environmental models and improved models for calculating single event effects. The need for a revision of CREME also stimulated the development of the CHIME (CRRES/SPACERAD Heavy Ion Model of the Environment) and MACREE (Modeling and Analysis of Cosmic Ray Effects in Electronics). The Single Event Figure of Merit method was also revised to use the solar minimum galactic cosmic ray spectrum and extended to circular orbits down to 200 km at any inclination. More recently a series of commercial codes was developed by TRAD (Test & Radiations) which includes the OMERE code which calculates single event effects. There are other error rate prediction methods which use Monte Carlo techniques. In this chapter the analytic methods for estimating the environment within spacecraft will be discussed.

Adams, James H., Jr.↗

Forecasting Lightning Threat using Cloud-resolving Model Simulations

As numerical forecasts capable of resolving individual convective clouds become more common, it is of interest to see if quantitative forecasts of lightning flash rate density are possible, based on fields computed by the numerical model. Previous observational research has shown robust relationships between observed lightning flash rates and inferred updraft and large precipitation ice fields in the mixed phase regions of storms, and that these relationships might allow simulated fields to serve as proxies for lightning flash rate density. It is shown in this paper that two simple proxy fields do indeed provide reasonable and cost-effective bases for creating time-evolving maps of predicted lightning flash rate density, judging from a series of diverse simulation case study events in North Alabama for which Lightning Mapping Array data provide ground truth. One method is based on the product of upward velocity and the mixing ratio of precipitating ice hydrometeors, modeled as graupel only, in the mixed phase region of storms at the -15\dgc\ level, while the second method is based on the vertically integrated amounts of ice hydrometeors in each model grid column. Each method can be calibrated by comparing domainwide statistics of the peak values of simulated flash rate proxy fields against domainwide peak total lightning flash rate density data from observations. Tests show that the first method is able to capture much of the temporal variability of the lightning threat, while the second method does a better job of depicting the areal coverage of the threat. A blended solution is designed to retain most of the temporal sensitivity of the first method, while adding the improved spatial coverage of the second. Weather Research and Forecast Model simulations of selected North Alabama cases show that this model can distinguish the general character and intensity of most convective events, and that the proposed methods show promise as a means of generating quantitatively realistic fields of lightning threat. However, because models tend to have more difficulty in correctly predicting the instantaneous placement of storms, forecasts of the detailed location of the lightning threat based on single simulations can be in error. Although these model shortcomings presently limit the precision of lightning threat forecasts from individual runs of current generation models, the techniques proposed herein should continue to be applicable as newer and more accurate physically-based model versions, physical parameterizations, initialization techniques and ensembles of cloud-allowing forecasts become available.

McCaul, E. W., Jr.↗

Safety Case for Small Uncrewed Aircraft Systems (sUAS) Beyond Visual Line of Sight (BVLOS) Operations at NASA Langley Research Center

This Technical Memorandum (TM) is written to provide for dissemination of the methods and safety considerations for operations of small Uncrewed Aerial Systems (sUAS) Beyond Visual Line-of-Sight (BVLOS)at NASA Langley Research Center. It includes the Safety Case used to acquire a BVLOS Certificate of Authorization (COA) from the FAA and is being published to enable others to benefit from this work. The intended operations, subject to approval from the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA), will include a combination of Within Visual Line of Sight (WVLOS) and Beyond Visual Line of Sight (BVLOS) flights, comprising of at most five sUAS operating concurrently, with no more than three operating BVLOS. Flights will occur in a subset of the Langley Air Force Base (LAFB) Class D airspace (KLFI) at a maximum altitude of 400 ft AGL. Most operations within this subset will take place in the City Environment Range Testing for Autonomous Integrated Navigation (CERTAIN) Range. The CERTAIN Range includes airspace inside the borders of NASA Langley Research Center (LaRC). Additional airspace over the northern section of CERTAIN will be requested as part of the Certificate of Authorization (COA). NASA LaRC BVLOS operations on the CERTAIN Range can be broken down into five critical components needed to meet the 14 CFR § 91.113 see and avoid requirement: 1) procedural deconfliction with LAFB for UAS operations at or below 400 ft and manned aircraft at or above 900’ AGL; 2) ground equipment for detection of intruder aircraft and to support communications between crewmembers ; 3) sUAS vehicles with advanced onboard automation capable of autonomously maintaining safe separation; 4) BVLOS standardized operating procedures (SOPs); 5) and personnel to execute the flight operations in accordance with the SOPs and respond to airborne contingencies. The introduction of new ground equipment includes the use of the Remote Operations for Autonomous Missions (ROAM) UAS Operations Center, development and use of an Integrated Airspace Display (IAD), use of the L-STAR and GA-9120 radars, and the incorporation of standardized Vertiports. The ROAM Operations Center will be the central point for all BVLOS sUAS operations. All command and control (C2), voice communications and airspace awareness displays will reside inside ROAM. The IAD will provide raw data from ADS-B, FLARM, radar tracks and telemetered GPS vehicle positions for interpretation by an Airspace Monitor. The radars will search the class D airspace around the CERTAIN Range and serve as a backup to procedural deconfliction procedures coordinated with LAFB. In the event of a procedural deconfliction breakdown, radar detections of non-participating aircraft will be available so that the 91.113 see and avoid requirement can still be safely met. Finally, the incorporation of Vertiports will have video and network connectivity that enables large numbers of sUAS launches and recoveries from a single location. This is a continuation of the remote command and control of unpiloted aircraft component focused on evaluating unpiloted aircraft flight crew roles and responsibilities, control interfaces and the associated data links needed to operate a fleet of aircraft within a UAM Ecosystem. This work supports the development of future aviation operational concepts based on an Urban Air Mobility Maturity Level (UML) 4 environment (Patterson, 2020). It is assumed that future airspace will include hundreds of simultaneous aircraft operations within the airspace, therefore scalable operations are essential for enabling this future airspace to become a reality. Follow on work includes envisioned flights that expand operations beyond the CERTAIN range and lead to an effective Maritime Surveillance capability.

Matthew W Coldsnow↗