Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage Duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Achieving American Leadership in the Grid Storage Supply Chain Factsheet

To meet growing demand for long duration energy storage, domestic manufacturing will have to increase significantly. The use of renewables is rapidly increasing, and the adaption of electric vehicles is on the rise, which will require the national grid to not only produce and deliver electricity, but also store it reliably and cost-effectively. The International Energy Agency (IEA) recently released a report showing that to reach a goal of net-zero emissions by 2050, grid storage will need to grow to almost 2,500 gigawatt hours (GWh) in less than a decade. Currently, across the globe, battery technologies provide over 30 GWh of grid storage(BloombergNEF, 2020) while pumped storage hydropower (PSH)provides 160 gigawatts (GW) of long-duration energy storage (LDES) (PSH) (U.S. Department of Energy, 2020). This fact sheet summarizes strategies to address key vulnerabilities in the grid storage supply chain, the United States. These strategies include: • Developing domestic, sustainable manufacturing and recycling capabilities along the energy storage supply chain. • Maximizing the use of domestic resources by focusing on second-life and recycling technologies. • Enabling the diversification and deployment of grid storage technologies through targeted research activities. Addressing these opportunities will have significant impacts with respect to increasing well-paying skilled domestic jobs, improving the gross domestic product (GDP), and ensuring minimal environmental and climate impacts.

Source record↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Binder-free thin graphite fiber mat sandwich electrode architectures for energy-efficient vanadium redox flow batteries

Vanadium redox flow batteries (VRFB) are emerging as the preferred energy storage solution for long-duration energy storage (LDES) and grid-scale load levelling. In this study, we report a novel binder-free sandwich electrode architecture consisting of a thin layer (6–12 mg cm –2 ) of thermally activated graphite felt mat (TGFM) sandwiched between thin carbon papers (TCP-TGFM-TCP). This electrode architecture substantially reduced the polarization (I-V) resistance of the VRFB by 23 %, resulting in a current density increase from 340 mA cm –2 at 1 V for the thermally activated graphite felt (TGF) electrode to 470 mA cm –2 at 1 V, and an energy efficiency of 80 % at 100 mA cm –2 is realized.

25 ENERGY STORAGE↗

Oilwell Conversion (Well API 121913310501) to Geothermal Heat Storage Well for Flexible Electricity Storage

Geothermal growth is limited by a lack of geographically dispersed high-temperature thermal resources and high initial upfront investment in characterization and well construction. This project intended to address the challenges of energy supply intermittency and enhance grid resilience, reliability, and energy security by storing energy provided from currently available renewable resources in the subsurface to harvest it a later time during at-peak energy demand. This project intended to improve geothermal adoption, reduce initial project risk, and improve price competitiveness through utilizing existing oil and gas infrastructure such as non-productive wells, non-economic fields, dry holes, and orphaned wells. The project also intended to address the lack of geographically dispersed thermal resources and enhance grid resilience, reliability, and energy security by introducing an economical method for storing energy from currently available renewable resources in the subsurface for usage during at-peak energy demand. During this research, the project furthered the understanding of the feasibility of utilizing abandoned oil and gas wells as geothermal heat storage wells. The project team investigated the heat storage and hydrogeological characteristics of subsurface reservoirs in the Illinois Basin to evaluate their response to heat injection for determining the evolution of temperature profiles and heat losses over time using existing and available data sets. The project team then performed modeling and simulation to evaluate the heat losses of returning fluids during heat extraction. The outputs were used to select an optimal candidate reservoir and location in Southern Illinois. The team designed and performed a small-scale field test in an existing oil well to refine the model and to demonstrate the permitting and regulatory pathways necessary for the conversion of oil and gas assets to geothermal use. The field test also serves as a proof of concept and can guide the procedures for future research and implementation. Additionally, the project team, conducted initial market research and customer discovery to develop a go to market strategy for an Advanced Geothermal Energy Storage (AGES) system. The project team in this research also identified the parameters to be refined in future research, to improve the current go to market strategy economic model. To this end several subject matter experts were also identified to assist in future research with geothermal infrastructure setup, energy storage policy and law, energy storage market demand, potential siting based on demand etc. Future research will involve further sophistication of the site commercial modeling, implementing a larger-scale test, and further refinement of the thermodynamic modeling/simulation process. The output will be lifecycle costs and economics suitable for comparison to alternative approaches from a validated full-scale demonstration for venture capital investment into this technology. The project successfully demonstrated the ability to leverage existing oilfield infrastructure, permits, and land access and leasing agreements, to enable geothermal storage projects to come online faster and cheaper than a greenfield development could. This technology could allow for greater energy independence and security through long-term energy storage solutions. The longer duration allows for greater storage for renewables currently limited by hours-long storage durations of lithium-ion. The AGES system would support the growth of renewable energy farms, and provide greater opportunities for a cleaner energy infrastructure.

15 GEOTHERMAL ENERGY↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing Hydrogen Storage Potential in U.S. Underground Gas Storage Facilities

Abstract Underground hydrogen storage is a long‐duration energy storage option for a low‐carbon economy. Although research into the technical feasibility of underground hydrogen storage is ongoing, existing underground gas storage (UGS) facilities are appealing candidates for the technology because of their ability to store and deliver natural gas. We estimate that UGS facilities in the United States (U.S.) can store 327 TWh (9.8 MMT) of pure hydrogen. A complete transition to hydrogen storage would reduce the collective working‐gas energy of UGS facilities by ∼75%; however, most (73.2%) UGS facilities could maintain current energy demand using a 20% hydrogen‐natural gas blend. U.S. UGS facilities can buffer 23.9%–44.6% of the high and low hydrogen demand projected for 2050, respectively, which exceeds the current percentage of natural gas demand buffered by storage. Thus, transitioning UGS infrastructure to hydrogen could substantially reduce the number of new hydrogen storage facilities needed to support a hydrogen economy.

08 HYDROGEN↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Compressed Gas Energy Storage Integrated with Combined Heat and Power Plant

A new energy storage technology, Comrpessed Gas Energy Storage (CGES), seeks to achieve low-cost, long-duration eenrgy storage by combining mature commercially-available technology (compressors, high-pressure gas storage, expander generators) and utilizing existing infrastructure for transportation and distribution of industrial gases. CGES utilizes existing compressors to transform electricity into potential energy (pressure), existing pipelines or underground storage to store said potential energy, and adds new expander generators at pressure reduction points in the networkm to recover part of the energy used in compression and transform it into electricity. By adapting itself to widely available existing infrastructure, CGES recovers energy that is otherwise wasted in the gas value chain, reduces the cost of new facilities, and avoids many of the development huddles typically associated with other long-duration energy storage technologies (e.g., Compressed Air Energy Storage, CAES). This paper discusses the performance and economics associated with CGES as a standalone project and in combination with a thermal power plant, based on a concept for integration of the technology over an existing lateral pipeline transporting natural gas to an 85 MW combined heat and power plant that feeds power to a grid with increasing share of renewable power generation.

03 NATURAL GAS↗

Technoeconomic Analysis of Discrete and Unitized Reversible Fuel Cells for Energy Storage Applications

Reversible Fuel Cell (RFC) systems offer promising characteristics for stationary long duration energy storage applications. Two main configurations of RFC systems exist: discrete RFC systems and unitized RFC systems. While discrete RFC systems combine independent fuel cell and electrolyzer systems for energy storage, unitized RFC systems utilize a single electrochemical stack and might share balance of plant (BOP) components for both charging and discharging processes. While this configuration reduces upfront capital costs, challenges of unitized RFC designs include potential performance trade-offs due to dual-mode stack design and operational complexities across varying loads and operating conditions. Furthermore, these tradeoffs might be different for low-temperature PEM RFCs than for high-temperature reversible solid oxide cell systems. The goal of this project is to assess unitized RFC system potential in the context of long duration grid energy storage and HFTO's technical targets for different discrete fuel cell and electrolyzer technologies. This presentation presents preliminary review of state-of-the-art unitized RFC cells and assesses how they perform relative to HFTO's technical targets. It also presents literature-derived system configurations worth investigating. This review indicates that lab-scale unitized RFCs are making good progress towards meeting HFTO's technical targets.

HYDROGEN↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

Demonstration of 10+ hour energy storage with Φ1" laboratory size solid oxide iron–air batteries

Long duration electricity storage (LDES) with 10+ hour cycle duration is an economically competitive strategy to accelerate the penetration of renewable energy into the utility market. Unfortunately, none of the available energy storage technologies can meet the LDES requirements in terms of duration and cost. The newly emerged solid-oxide iron–air batteries (SOIABs) with energy-dense solid iron as an energy storage material have inherent advantages for LDES applications. Herein, we report for the first time the LDES capability of SOIABs even at a laboratory scale. We show that SOIABs with an Ir-catalyzed Fe-bed can achieve excellent energy density (625 W h kg –1 ), long cycle duration (12.5 h) and high round-trip efficiency (~90%) under LDES-related working conditions. Finally, given the excellent low-rate performance and the use of earth-abundant, low-cost Fe as an energy storage material, we conclude that the SOIAB is a well-suited battery technology for LDES applications.

25 ENERGY STORAGE↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

High Performance Flow Battery with Inexpensive Inorganic Reactants: DAYS Program (Final Technical Report)

RTRC’s DAYS projects focused on new flow battery (FB) chemistries for long duration energy storage: one that pairs aqueous polysulfide and manganese active materials in strongly alkaline electrolytes (S/Mn); another explores ligand-modified metal (LMM) chemistries in moderate pH electrolyte conditions. The S/Mn chemistry met durability targets by running for over 500 cycles and 1000 hours. Combined with this durability, power densities of up to 60 mW/cm2 at 80% round-trip efficiency, and exceptionally low-cost S and Mn active materials, the S/Mn FB offers a pathway to meeting the <5¢/kW-hr levelized cost of storage (LCOS) target first proposed by the DAYS Program and accepted by the DOE Energy Storage Grand Challenge. The LMM chemistry made impressive progress as well, including durability tests that retained performance over 600 hours of cycling. Cell optimization allowed this chemistry to operate as high as 500 mW/cm2 at 80% round-trip efficiency, nearly 10x the power density of S/Mn and comparable to the power density achieved in RTRC’s flow battery stacks using acidic vanadium battery solutions. This enabled the LMM chemistry to also offer a pathway to the <5¢/kW-hr LCOS DAYS and DOE targets. The promising results from the LMM chemistry have led to a recent DOE AMO award to advance the technology to a 5 kW, 20 kW-hr prototype.

25 ENERGY STORAGE↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Impact of electrolyte solutions on carbon dioxide fixation in single chamber Al–CO 2 battery

Governments and research & development (R&D) organizations are actively initiating various programs and research strategies for CO 2 capture, its utilization, and integration with long duration energy storage from renewable sources worldwide. In line with the carbon capture goals, here we report a novel electrochemical Al-CO 2 battery cell, that can simultaneously capture CO 2 and convert it into value-added products, in addition to long-duration energy generation and storage. Here, this innovative approach employs cost-effective Al metal as an anode and an in-house synthesized Ni–Fe based bimetallic double hydroxide catalyst as the cathode, with meticulously optimized compositions and morphologies. We explore the impact of different aqueous electrolyte solutions compositions on the cell performance, demonstrating up to 10 h of stable long duration energy storage with a stable voltage profile. The cell exhibits low polarization even at high current densities of up to 12 mA cm -2 and maintains stable cycling over 500 h. Through Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray Diffraction and X-ray photoelectron spectroscopy (XPS) analysis, we determined that the discharge product is either NaAlCO 3 (OH) 2 or KAlCO 3 (OH) 2 , distinct from the Al 2 (CO 3 ) 3 typically reported in conventional Al–CO 2 batteries.

25 ENERGY STORAGE↗