Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL CONVECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Mitigation of Molten Salt Corrosion

The desire to increase the peak operational temperature of Concentrated Solar Power (CSP) plants to lower the levelized cost of CSP-derived electricity, has led to consideration of an earth-abundant, low-cost, thermally-stable, molten MgCl 2 -KCl-NaCl (40-40-20 mole%) salt for high-temperature thermal energy storage and heat transfer. The reliable, long-term containment of such a molten salt is challenging, however, due to the corrosion of cost-effective, high-temperature structural metal alloys in this salt (particularly if this salt is contaminated with oxygen-bearing species). This project has been focused on: i) development of equipment for evaluating corrosion kinetics in molten chlorides under well-controlled thermal, fluid dynamic, and atmospheric conditions at CSP-relevant temperatures, ii) use of such equipment to evaluate the influence of forced convection on corrosion kinetics (to determine the role of liquid phase diffusion on such corrosion), and iii) identifying a corrosion-mitigation strategy that can be industrially applied to achieve a projected annual corrosion ≤30 μm at CSP-relevant temperatures. The overall goals of this project have been: i) to understand the rate-limiting step(s) and associated kinetic laws governing corrosion in molten chlorides at 750°C, ii) to determine key operational parameters affecting the corrosion kinetics in molten salts, and iii) to demonstrate the tailoring of such parameters to appreciably reduce such corrosion.

14 SOLAR ENERGY↗

Thermal conductivity of CaSiO 3 perovskite at lower mantle conditions

Thermal conductivity (κ) of mantle minerals is key to understanding dynamics in the deep Earth. It controls the style of mantle convection and the timescale of cooling both the mantle and the core. Cubic CaSiO 3 perovskite (CaPv) is the third most abundant mineral in the lower mantle (7 vol %). Despite its importance, no theoretical or experimental estimate of CaPv's κ is available. Theoretical investigations of its properties are challenging because of its strong anharmonicity. Experimental measurements at relevant pressures and temperatures are equally challenging. Here we present ab initio results for CaPv's κ obtained using the phonon quasiparticle approach to address its strong anharmonicity. We also offer experimental measurements of κ up to 67 GPa and 1950 K. Predictions and measurements are in good agreement and reveal a surprisingly large κ for cubic CaPv that can be explained on the basis of its high crystal structure symmetry. Despite its relatively low abundance, CaPv's κ increases the lower mantle κ by ~10 %, if accounted for. κ of mantle regions enriched in subducted crustal materials will be more strongly impacted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aerosol Impacts on Mesoscale Convective Systems Forming Under Different Vertical Wind Shear Conditions

Following our previous study of wind shear effect on mesoscale convective system (MCS) organization under a clean atmospheric condition using the Weather Research and Forecasting model coupled with Spectral-Bin Microphysics, we conduct sensitivity simulations by increasing cloud condensation nuclei (CCN) concentration and investigate aerosol impacts on MCSs forming under different wind shear conditions. We find that, aerosols induce stronger updrafts and downdrafts in all MCSs. The stronger updrafts and enlarged convective core area contribute to larger vertical mass fluxes and enhance precipitation, indicating convective invigoration. Increased updraft speed below 8-km altitude mainly results from enhanced condensational heating, and increased water loading effect is not large enough to overcome the increase in thermal buoyancy. Interestingly, above 8-km altitude we see reduced updraft speed by the increased aerosols due to reduced vertical pressure perturbation gradient force, and weakened depositional growth due to competition of water vapor by enhanced condensation. The accumulated rainfall and mean rain rate are increased, with an increased occurrence frequency of heavy rain. The increase of rain rate is seen in both convective and stratiform regions, with a more significant increase in convective rain rate. In general, we see a higher frequency of deep convective cloud in the polluted condition because of invigorated convection, and more stratiform/anvil clouds, but a lower frequency of shallow warm clouds. The unanimously invigorated MCSs by aerosols under various wind shear conditions revealed by this study has an important implication in weather and climate at warm and humid regions that are influenced by pollution.

54 ENVIRONMENTAL SCIENCES↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE neams program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework. This report summarizes recent advances in developing an integrated system- and engineering-scale modeling capability for the msr concept, which has gained significant interest in recent years. A consistent framework was established by coupling Pronghorn and SAM through the Saline interface, with thermophysical properties provided by the Molten Salt Thermal Property Database (MSTDB-TP). Further improvements were made to the coupling schemes and domain-overlapping strategies, enhancing the stability and robustness of multi-code simulations. Verification and validation efforts demonstrate the accuracy of this integration across a range of benchmark problems, including one-dimensional heated pipe flows, three-dimensional natural convection loops with evolving isotopic compositions, and \gls{msre} demonstration cases. Within Pronghorn, new capabilities were introduced to model corrosion and noble-metal plating phenomena, supported by an extended thermal-hydraulics framework and refined turbulence treatments. To capture two-phase flow behavior, a multiphase Euler–Euler model was implemented in Pronghorn, including advanced closure relations, high-resolution advection techniques, and capillary force reconstruction. Preliminary verification cases confirm the fidelity of the approach, while planned validation efforts target canonical multiphase benchmarks and application to msr components such as the msre pump bowl. Finally, updates to SAM’s msr mass transfer modeling were extended to consider noble gas migration into porous structures like graphite. The point kinetics model was updated to include reactivity feedback contributions from any defined species, such as xenon. The gas transport model was expanded for applicability to gas mixtures, bubble efflux phenomena, and species transport between liquid and gas phases. A selection of multi-scale Sherwood number correlations from MOSCATO/NekRS and multi-phase correlations from literature have been added for improved accuracy in calculating mass transfer coefficients. A companion effort on developing system-level redox corrosion has also been incorporated into SAM. Collectively, these enhancements strengthen the predictive capability of SAM and Pronghorn for simulating MSR thermal-hydraulics, corrosion, multiphase behavior, and fission-product transport, providing a more complete toolset for design, safety analysis, and licensing support of next-generation \gls{msr}s.

42 - ENGINEERING↗

A Simplified Approach Based on Cellular Automata for Describing Direct Reduced Iron Production in Different Reducing Conditions

A quick computation approach based on cellular automata is developed and implemented to describe the reduction of iron ore pellets by a mixture of reducing agents featured by different H 2 /CO ratios. The evolution of oxygen concentration inside the pellet is followed from the beginning to the end of contact between reducing agent and pellet. The variation of thermal state of pellets and gas mixture is computed based on their initial temperature, considering the heat involved and the convective heat exchange between pellet and gas mixture. The use of cellular automata and finite‐difference method to solve the diffusion equation point out the absence of any diffusion coefficient value, allowing to make the model fit the experimental trial, because the problem is that it is not ruled just by diffusion but also by the concentration variation of reducing agent inside the pellet due to porosity increasing during reduction. The updating of the reducing agents concentration implies a sharp decrease of oxygen concentration that the cellular automata model considers. The developed model is able to provide the in‐line control of reduction process and could be used to adjust the chemical concentration and temperature of injected reducing agents.

Metallurgy & Metallurgical Engineering↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

Analytical Modeling of Metal Foam Composite Phase Change Materials (PCM) in Thermal Energy Storage Using Asymptotic Analysis

The use of phase change materials (PCMs) for thermal energy storage can release or absorb a significant amount of latent heat during the freezing or melting process, offering a higher energy storage density. One of the main drawbacks of PCMs is their low thermal conductivity, resulting in poor thermal performance. Recent research has attempted to enhance heat transfer and increase the thermal conductivity of PCMs, including the use of metal foams. However, modeling the metal foam composite PCM using conventional methods is computationally expensive. This paper proposes an asymptotic solution for a Stefan-like problem subject to a convective boundary for outward solidification in a hollow cylinder, capable of predicting the freeze-melt cycle of the metal foam composite PCM. Specifically, three temporal regimes and four spatial layers are considered in the asymptotic analysis for each phase change process. The thermal conductivity is calculated by a theoretical three-dimensional tetrakaidecahedron model, while other thermophysical properties are obtained using the method of volume averaging. The results are verified with numerical data and validated against experimental data in the literature. The presented analytical modeling framework could have the potential to be applied to other types of composite PCMs with considerably lower computational costs compared with conventional methods.

analytical model↗

Proper orthogonal decomposition based reduced-order modeling of flux-Limited gray thermal radiation

Here, in this work, a proper orthogonal decomposition (POD) based reduced-order model (ROM) is developed to solve gray, flux-limited thermal radiation diffusion. We focus on the variable opacity radiation penetration benchmark posed by Olson, Auer, and Hall. The T -3 relationship for opacity in conjunction with high-temperature radiation penetrating an initially cold material produces a strong thermal radiation shock. This class of problems is particularly challenging for standard POD-based reduced-order modeling due to the nonlinearities presented by 1) the T 4 source term, and 2) flux-limited diffusion operator. To address these challenges and develop a cost competitive ROM, we employ a “hyper-reduction” technique through discrete empirical interpolation (DEIM) and allow for adaptive reduced-order projections through principal interval decomposition (PID). Performance of the proposed methodology is quantified by comparing the cost savings and accuracy relative to a full-order computation. Reference solutions and snapshot data are obtained through a full-order calculation performed by the University of Chicago maintained astrophysics code, FLASH. For consistency and potential extensibility, the developed ROM is also implemented in FLASH. We find that in the initialization regime, where the thermal radiation wave is initially created by the warming of the material, this class of problems is highly reducible and suitable for POD-based ROMs. However, the strong convective nature of the wave propagation regime is less reducible and more challenging to create an efficient ROM.

42 ENGINEERING↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

A code-to-code benchmark for magneto-convection in a horizontal duct

Liquid metals and magnetic fields are used in many technical applications such as metallurgy, crystal growth and nuclear fusion reactors. When an electrically conducting fluid moves in a magnetic environment, electric currents and electromagnetic forces are generated that affect velocity and pressure losses in the flow. These magnetohydrodynamic (MHD) interactions have to be investigated to optimize the engineering processes. The characteristics of MHD flows depend on the geometrical configuration, the strength of the applied magnetic field, the electrical properties of fluid and structural materials and the thermal conditions. In the so-called blankets for fusion reactors, where liquid metals are used to breed the plasma fuel component tritium and to extract the generated heat, magneto-convective flows play a crucial role in determining heat and mass transfer. Therefore, the availability of numerical codes to simulate this type of flow is mandatory and their validation is a necessary step to guarantee the reliability of the results. For that reason, a benchmark problem has been defined to simulate liquid metal flows in a horizontal rectangular duct heated from below and exposed to a non-uniform magnetic field. Results obtained by five research groups using different codes are compared.

benchmark↗

Volumetrically Absorbing Thermal Insulator (VATI) for High-temperature Receivers

This project seeks to exploit volumetric absorption of concentrated solar irradiation in a thin, high-temperature, thermally conductive medium. High efficiency thermal conversion is achieved by volumetric absorption of both incoming solar irradiation (short wavelength) and emitted irradiation (long wavelength), demonstrating a volumetrically absorbing thermally insulating (VATI) effect. The thermalized energy is conducted to the back wall, enclosing the working fluid (molten salt or supercritical CO 2 ). Reliance on conductive thermal transport requires a thermally conductive medium, in the absence of which large temperature gradients drive losses due to emission. The project’s outcomes are important to realize a cost-effective approach to reduce optical and thermal losses from CSP receivers at high temperatures (720°C). High-temperature stable and commercially available porous SiC structures (open-cell foams) were explored as a volumetrically absorbing and thermally insulating layer. To the best of our knowledge, the current state-of-the-art for industrially deployed coatings is Pyromark. However, Pyromark suffers degradation at 700+°C and diurnal temperature changes. This necessitates periodic recoating, and the downtime increases the overall levelized cost of energy (LCOE) production. On the other hand, contemporary research activities have generated significant advances in the development of selective emitter coatings, which present challenges with costs, scalability, and stability. The pursued approach alleviates these concerns by developing a receiver that utilizes the inherent structure of high-temperature stable porous materials to enable robust and cost-effective receivers which require no periodic maintenance downtimes. The overall goal of the project is to experimentally demonstrate a figure of merit (FOM) of 0.92 at a temperature of 720°C and solar irradiation of 1000x concentration with porous receivers. The relevant crystallographic (phase) optical and thermal properties of porous SiC were first characterized. Second, the 3-D geometry of the porous SiC was analyzed using micro-X-ray tomography and converted to CAD data using image processing analysis. Utilizing this 3-D geometry and relevant optical/thermal properties, Monte Carlo- Ray Tracing (MCRT) analysis was performed to extract important parameters governing solar-thermal energy conversion such as extinction coefficient (β, 1/m), scattering albedo (ω) and the scattering phase function (Φ). These properties were then integrated into an in-house radiative and conduction transport model to solve for temperature and transport fluxes characterizing the solar-thermal energy conversion. This model was utilized to predict the FOM for various SiC porous geometries and to identify the highest possible FOM. Testing of the optimized porous structures will be accomplished with a custom-built high-accuracy (< ±4%) FOM measurement test-stand and a 1000x solar concentrator. When neglecting convective losses and resistance at the open boundary and the back wall, the optimized SiC foam leads to a FOM of 0.84. This FOM does not surpass the performance of Pyromark 2500. Yet, conversely to Pyromark 2500, SiC is stable at high temperatures and does not degrade over time. Also, it is possible to boost the FOM of SiC by engineering its effective thermal conductivity and its scattering albedo. A FOM of 0.92 is predicted for an optimized foam by accounting for convective losses and resistance at the open boundary and the back wall. This largely exceeds the FOM of Pyromark 2500 (~0.86) predicted by neglecting convective losses and resistance. Therefore, further engineering of the foam could lead to unprecedented FOMs.

14 SOLAR ENERGY↗

Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

Conceptual Design of a Pumped Water Capsule for TREAT

This study performed mechanical design, thermal hydraulic, and fuel performance investigations to determine whether an existing large water capsule design could be modified to create forced convection boundary conditions on nuclear fuel specimens in the Transient Reactor Test facility. This concept was found to be viable and offers several advantages compared to a static water environment for a variety of transient power shape categories. The pumped capsule is not foreseen to be superior to a past concept for a larger water loop, but the pumped capsule approach is recommended for further engineering and deployment based on its high cost-to-value ratio primarily as a stop gap capability until a larger water loop can be realized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal performance of phase change materials with anisotropic carbon fiber inserts

In thermal energy storage systems, phase change materials (PCMs) are widely used for thermal energy management. Most PCMs have low thermal conductivities, which limits the heat transfer rate within PCM and thus makes the phase-changing process very slow. However, thermal conductivities of PCMs can be altered by inserting targeted additives. We hypothesize that the size and shape of these additive inserts play a key role in thermal management efficiency. To this end, the impacts of carbon fiber (CF) inserts on the phase change behavior and consequent heat transfer efficiencies of inorganic and organic PCMs were investigated using experiments and simulations. Long, anisotropic CFs with high thermal conductivities formed continuous fast heat flux tunnels inside PCMs to enhance the heat transfer. Such CFs could extend the phase change fronts from the limited container-shaped interface to the larger surface of numerous CF inserts inside the PCM. These special CF inserts work with a new heat transfer mechanism, different from conventional small additives or long isotropic CF inserts. The thermal energy release rate increased by 2.5 times with 1 wt.% anisotropic CF inserts in inorganic PCM. However, CF inserts in liquid organic PCM hindered the natural convection and compromised the improved heat conduction. In conclusion, the lab-scale multiphysics simulations support these experimental observations and indicate that CF inserts have potential to enhance heat transfer in inorganic PCMs, but they are less effective in organic PCMs.

25 ENERGY STORAGE↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗